PubMed Health⌕ Search

Biomedical subjects

C S Henriquez

Publications and source records attributed to C S Henriquez.

27 records · Page 2Linked to original sources

Simulation of propagation along a cylindrical bundle of cardiac tissue--I: Mathematical formulation.

This paper presents a mathematical description based on a three-dimensional model for studying propagation in cardiac muscle. The model makes use of the bidomain concept to construct a representation of a cylindrical, multicellular bundle lying in an extensive volume conductor. The equations for the cylindrical bidomain are derived here for different combinations of boundary conditions and simplifying assumptions. The analysis shows that an analytic model for propagation can be set up if one assumes that the ratio of the intracellular and interstitial bidomain conductivities in the radial and axial direction are the same (i.e., equal anisotropy) and the intracellular radial current density vanishes at the surface. The simulation of this model will be discussed in a subsequent paper. As a point of reference, the classical one-dimensional cable model is also examined and the expressions governing propagation are reformulated to account for the extracellular medium, a factor ignored in most simulation studies.

Action Potentials↗

Simulation of propagation along a cylindrical bundle of cardiac tissue--II: Results of simulation.

Previous evaluations of the cylindrical bidomain model of a bundle of cardiac tissue, have been obtained by using an analytic function for the transmembrane potential and assuming the activating wavefront through the bundle cross section is planar. In this paper, nonlinear membrane kinetics are introduced into the bidomain membrane and equal anisotropy ratios are assumed, permitting the transmembrane potential to be computed and its behavior examined at different depths in the bundle and for different values of conductivity and bundle diameters. In contrast with single fiber models, the bundle model reveals that the shape of the action potential is influenced by tissue resistivities. In addition, the steady-state activation wavefront through the cross-section perpendicular to the long axis of the bundle is not planar and propagates with a velocity that lies between that of a single fiber in an unbounded volume and a single fiber in a restricted extracellular space. In general, the bundle model is shown to be significantly better than the classical single fiber model in describing the behavior of real cardiac tissue.

Action Potentials↗

Finite element analysis of bioelectric phenomena.

This article reviews the application of finite element methods to models of bioelectric phenomena. The models represent the electrical fields created in the body as a result of membrane current sources or external current applied for diagnostic or therapeutic purposes. We formulate the governing equations for these models and then derive the finite element equations for the generalized bioelectric problem. The 32 papers reviewed here, all those appearing in the literature to date, cover the areas of electrocardiology, therapeutic and functional electrical stimulation in the cerebellum, cochlea, spinal cord, and peripheral nerves, cardiac defibrillation, electrical impedance tomography, bidomain cardiac models, electroporation, and therapeutic electrical stimulation of bone. For each, we summarize the purpose of the study, the model details and assumptions, the major results, and the applicability of the study. The models are then considered as a group to critique the appropriateness of the finite element method, the means of implementation, and the factors affecting accuracy, thus providing an overview of the state of finite element modeling of bioelectric phenomena.

Central Nervous System Diseases↗

Potential and current distributions in a cylindrical bundle of cardiac tissue.

The intracellular and interstitial potentials associated with each cell or fiber in multicellular preparations carrying a uniformly propagating wave are important for characterizing the electrophysiological behavior of the preparation and in particular, for evaluating the source contributed by each fiber. The aforementioned potentials depend on a number of factors including the conductivities characterizing the intracellular, interstitial, and extracellular domains, the thickness of the tissue, and the distance (depth) of the field point from the surface of the tissue. A model study is presented describing the extracellular and interstitial potential distribution and current flow in a cylindrical bundle of cardiac muscle arising from a planar wavefront. For simplicity, the bundle is considered as a bidomain. Using typical values of conductivity, the results show that the intracellular and interstitial potential of fibers near the center of a very large bundle (greater than 10 mm) may be approximated by the potentials of a single fiber surrounded by a limited extracellular space (a fiber in oil), hence justifying a core-conductor model. For smaller bundles, the peak interstitial potential is less than that predicted by the core-conductor model but still large enough to affect the overall source strength. The magnitude of the source strength is greatest for fibers lying near the center of the bundle and diminishes sharply for fibers within 50 microns of the surface.

Animals↗

A finite volume model of cardiac propagation.

This paper describes a two-dimensional cardiac propagation model based on the finite volume method (FVM). This technique, originally derived and applied within the filed of computational fluid dynamics, is well suited to the investigation of conduction in cardiac electrophysiology. Specifically, the FVM permits the consideration of propagation in a realistic structure, subject to arbitrary fiber orientations and regionally defined properties. In this application of the FVM, an arbitrarily shaped domain is decomposed into a set of constitutive quadrilaterals. Calculations are performed in a computational space, in which the quadrilaterals are all represented simply as squares. Results are related to their physical-space equivalents by means of a transformation matrix. The method is applied to a number of cases. First, large-scale propagation is considered, in which a magnetic resonance-imaged cardiac cross-section serves as the governing geometry. Next, conduction is examined in the presence of an isthmus formed by the microvasculature in a slice of papillary muscle tissue. Under ischemic conditions, the safety factor for propagation is seen to be related to orientation of the fibers within the isthmus. Finally, conduction is studied in the presence of an inexcitable obstacle and a curved fiber field. This example illustrates the dramatic influence of the complex orientation of the fibers on the resulting activation pattern. The FVM provides a means of accurately modeling the cardiac structure and can help bridge the gap between computation and experiment in cardiac electrophysiology.

Algorithms↗

Spatial potential and current distributions along transvenous defibrillation electrodes: variation of electrode characteristics.

The therapeutic efficacy of an endocardial defibrillation lead system can be improved by controlling the profile of current delivery through a suitable choice of electrode characteristics, which include the length, radius, number of conductor elements, electrode resistance, and point of connection to the voltage source. Such control will minimize tissue and lead damage during long-term use. In this study, a semianalytical model was developed to study cylindrical electrodes of different constructions in an idealized electrolytic medium. Simulations were performed to investigate the effects of varying the electrode characteristics on the spatial voltage and current distributions and interelectrode resistance for cylindrical electrodes of different constructions. The results show that, for transvenous electrodes of realistic dimensions, the current distributions are determined largely by the edge effects. The edge effects increase as the aspect ratio of the electrode (length/radius) decrease. The multiple edges resulting from wrapping conductor elements over a nonconducting base are found to increase the nonuniformity and the current density over the conductor-covered surface. The model is used to demonstrate two techniques of controlling the current distribution. The first method involve modifying the electrode resistivity profile and point of connection. In the second approach, the electrode surface is covered with a thin film having a model-computed resistance profile. By using either methods to produce isocurrent electrodes, the interelectrode resistance is found to increase.

Electric Countershock↗