PubMed Health⌕ Search

Biomedical subjects

C S Kleinman

Publications and source records attributed to C S Kleinman.

At least 55 records · Page 3Linked to original sources

Balloon angioplasty for recurrent coarctation of aorta. Immediate and long-term results.

BACKGROUND: As angioplasty techniques have been refined and larger low-profile balloons developed, a nonsurgical approach to recoarctation has become available. Several reports have documented both the efficacy and safety of this procedure. However, there are little data available on the long-term follow-up of these patients. This report details the initial results and long-term evaluation of both the relief of obstruction and the presence of hypertension after balloon angioplasty for recurrent coarctation. METHODS AND RESULTS: Balloon angioplasty for recurrent coarctation of the aorta was performed 29 times in 26 patients at a median age of 4 years and 9 months (range, 4 months to 29 years), with eight patients less than 1 year old. Initial surgical techniques were end-to-end anastomosis in 11 patients, subclavian flap aortoplasty in 11 patients, and patch aortoplasty in four patients. Angioplasty was performed at a median interval of 2 years and 7 months (range, 4 months to 23 years) after surgery. Mean peak systolic pressure difference across the coarctation decreased from 40.0 +/- 16.8 to 10.3 +/- 9.5 mm Hg (p less than 0.05) after the initial angioplasty, and mean diameter of the aortic lumen at the coarctation site increased from 5.8 +/- 3.5 to 9.0 +/- 4.3 mm (p less than 0.05). There was no mortality, and only one patient developed an aneurysm (4%). Three patients underwent repeat angioplasty for a pressure difference of more than 20 mm Hg. Long-term follow-up is available on 24 of 26 patients with a mean follow-up of 42 +/- 24 months (range, 12-88 months). Mean peak systolic pressure difference across the area of coarctation decreased from 40.3 +/- 17.4 before angioplasty to 8.5 +/- 8.3 mm Hg after final angioplasty (p less than 0.05) and 7.5 +/- 7.5 mm Hg at follow-up. Mean peak systolic blood pressure in the upper extremities decreased from 133.1 +/- 14.9 before angioplasty to 111.1 +/- 14.1 mm Hg at long-term follow-up (p less than 0.05). CONCLUSIONS: Balloon angioplasty should be considered the treatment of choice for relief of recurrent aortic coarctation.

Angioplasty, Balloon↗

Can umbilical artery pulsatility index predict the outcome of fetuses with structural heart disease?

Umbilical artery Doppler waveforms have been suggested to demonstrate diminished end-diastolic velocities in anomalous fetuses. We evaluated 11 fetuses with antenatally diagnosed congenital heart disease (CHD) and compared them to a normal population. Fetuses with CHD were studied once each and ranged in age from 19 to 32 weeks gestation. Eight had normal chromosomes, and three were aneuploid. The pulsatility index (PI) was elevated (above the 90th percentile for gestational age) in 3/11 CHD fetuses (P = NS). Elevated PI did not discriminate well between those with fatal and nonfatal lesions. Although all three fetuses with elevated PI had fatal disease, five of eight fetuses with fatal anomalies had normal PI values. We conclude that, while umbilical artery PI values were elevated in a subgroup of affected fetuses, this was not clinically helpful.

Female↗

Doppler echocardiography and color flow mapping.

Doppler color flow mapping permits real-time integration of structural and functional information. Flow through fetal and maternal vessels can be examined. Evaluation of fetal cardiac function can be enhanced, and structural abnormalities can be thoroughly studied. Other important applications include improved diagnoses of ectopic pregnancy and ovarian cancer.

Echocardiography, Doppler↗

The antenatal diagnosis of congenital heart disease using fetal echocardiography: is color flow mapping necessary?

Doppler color flow mapping is widely used in fetal echocardiography. We studied the impact of color flow mapping on fetal cardiac diagnosess. Between January 1, 1989 and June 30, 1990, we performed 854 fetal echocardiograms on 776 fetuses. Color flow mapping was used in 45 of 48 fetuses diagnosed as having cardiac abnormalities. Scans were reviewed to assess how color flow mapping influenced the ultimate diagnoses. Color flow mapping was essential to the correct anatomical diagnoses in 13 fetuses (29%), helpful but not essential in 21 (47%), and added little to two-dimensional examination alone in 11 (24%). It was essential in determining the course and flow direction in the great vessels when outflow obstruction was present or with transposition, and it was helpful but not essential in locating small jets of atrioventricular valve regurgitation. It was not helpful when the anatomical abnormalities were clearly identified from two-dimensional examination alone. We conclude that color flow mapping is helpful in the delineation of anatomical diagnoses in three-quarters of cases of fetal heart disease, particularly when the great vessels are abnormal. It may speed examinations by directing pulsed Doppler sampling. We did not find it essential to the proper recognition of anatomically abnormal hearts.

Echocardiography, Doppler↗

Transesophageal echocardiographic guidance of transcatheter closure of atrial septal defect.

Transcatheter closure of atrial septal defect (ASD) was accomplished in 10 of 11 patients aged 13 months to 46 years (weight range 11 to 77 kg). Transesophageal echocardiography (TEE) was used simultaneously with fluoroscopic imaging in 4 of these patients aged 4.5 to 46 years (weight range 19 to 77 kg). TEE was used to ascertain defect size, position and number of defects and to ascertain appropriate seating of the defect occluder within the atrial defect. In 2 patients TEE-assisted transcatheter ASD closure was accomplished after previous attempts at transcatheter ASD closure, unaided by TEE, had been unsuccessful. The only unsuccessful ASD closure procedure occurred in the smallest patient in the series (an 11-kg 13-month-old), a child who was too small to undergo TEE using our 11-mm diameter endoscopic probe. The concomitant use of TEE with fluoroscopic imaging provides information that is unique and complementary and may improve the efficacy and safety of the transcatheter technique for ASD closure. The recent availability of a 7-mm diameter TEE probe will extend the use of TEE into the infant age group and may decrease the discomfort and potential morbidity of TEE in older patients.

Cardiac Catheterization↗

Thirty-year follow-up of superior vena cava-pulmonary artery (Glenn) shunts.

The first superior vena cava-pulmonary artery shunt (Glenn shunt) in our series was performed in February 1958. From then through September 1988, 91 patients have undergone this procedure for a wide variety of congenital defects. We here report follow-up data available on all patients. Ages ranged from 2 days to 46 years (mean 6.8). Diagnoses were as follows: tricuspid atresia, 27; single ventricle, 22; tetralogy of Fallot, 14; D-transposition of the great arteries, ventricular septal defect, and pulmonary stenosis, 9; D-transposition, 5; Ebstein's anomaly, 4; pulmonary atresia + intact septum, 4; and others, 6. The hospital mortality rate was 7.7% (one death in the last 53 patients, 1.9%). Five deaths occurred in patients less than 6 months old. There were 20 late deaths (22%) with actuarial survival rates of 84% and 66% at 10 and 20 years, respectively. Pulmonary arteriovenous fistula formation was seen in 18 patients (19.7%), six of whom have undergone therapeutic embolization with improvement in saturation. The prevalence of pulmonary arteriovenous fistula increases with time after shunt. No long-term shunt thrombosis or stricture formation was seen. Fifty percent of shunts were still functioning at 20 years. Palliation was limited because of decrease in blood flow to the contralateral pulmonary artery, collaterals between the inferior and superior venae cavae, and pulmonary arteriovenous fistula formation. Improvement in saturation was obtained in eight otherwise inoperable patients by creation of a right axillary arteriovenous fistula up to 19 years after the Glenn shunt. Three patients had conversion of a Blalock-Taussig shunt to a Glenn shunt with improvement in congestive heart failure. Twenty-six patients have undergone a Fontan procedure with two deaths. Compared with the group having a Fontan procedure without a prior Glenn operation, there was no difference in early or late mortality. Thirty years after a Glenn shunt, the first patient in this series is working full time after having undergone a modified Fontan procedure in 1981. We conclude that the Glenn connection, usually with supplemental procedures to enhance oxygenation, has provided excellent physiologic palliation with low mortality up to 30 years with no late thrombosis or stricture formation. The incidence of pulmonary arteriovenous fistula increases with time and can be effectively treated with embolization. Physiologic repair after the Glenn shunt carries a low mortality. Although currently used infrequently, superior vena cava-pulmonary artery shunting remains a useful method of palliation in selected patients.(ABSTRACT TRUNCATED AT 400 WORDS)

Adolescent↗

Predictors of rhythm disturbances and subsequent morbidity after the Fontan operation.

The electrocardiographic, hemodynamic and surgical data of 30 patients who underwent a Fontan operation between 1977 and 1986 were retrospectively reviewed to identify the incidence and predictors of immediate and late postoperative arrhythmias and associated morbidity in long-term survivors. Of 4 patients who died less than 1 year after operation (mortality 13%), 1 death was related to an arrhythmia. Three patients were not in sinus rhythm before operation and were excluded from the statistical analysis that examined predictors of arrhythmias. The remaining 23 long-term survivors have been followed 6.3 +/- 2.6 years (mean +/- standard deviation) since surgery and all remain in New York Heart Association functional class I or II. Ten patients (43%) developed immediate postoperative arrhythmias (less than or equal to 30 days) whereas 11 (48%) had late arrhythmias. With up to 10.7 years of follow-up, the proportion of patients free from late arrhythmias continues to decline. Arrhythmias included bradyarrhythmias, atrial tachyarrhythmias, the tachy-brady syndrome and supraventricular ectopic activity. Immediate postoperative arrhythmias predicted late arrhythmias (p = 0.022). The preoperative electrocardiogram was the only variable useful in predicting both immediate and late postoperative arrhythmias. A more negative P-wave deflection in lead V1 (-2.4 +/- 0.7 vs -1.4 +/- 1.2 mV, p = 0.02) predicted patients with immediate postoperative arrhythmias, whereas both greater P-wave duration and a more negative deflection in this lead predicted late arrhythmias (103 +/- 14 vs 83 +/- 20 ms, p = 0.01, and -2.5 +/- 0.8 vs -1.3 +/- 1.0 mV, p = 0.005, respectively).(ABSTRACT TRUNCATED AT 250 WORDS)

Arrhythmias, Cardiac↗

Pulmonary venous collaterals secondary to superior vena cava stenosis: a rare cause of right-to-left shunting following repair of a sinus venosus atrial septal defect.

We describe a case of unusual pulmonary vein-to-vein collateral formation leading to systemic desaturation years following surgical repair of a sinus venosus atrial septal defect and partial anomalous pulmonary venous return from the right lung. At surgery, a single right upper lobe pulmonary vein branch was left draining high into the superior vena cava (SVC), resulting in a small left-to-right shunt. SVC obstruction developed at the site of the ASD repair and elevated venous pressure above the obstruction caused retrograde flow into the unincorporated pulmonary vein. Pulmonary vein-to-vein collaterals formed between this unincorporated vein and an adjacent pulmonary vein that had been surgically diverted to drain into the left atrium, resulting in a right-to-left shunt within the right lung. Normal pulmonary veins drain multiple bronchopulmonary segments, thus providing potential collateral pathways. Balloon angioplasty of the SVC stenosis successfully relieved the obstruction and abolished the right-to-left intrapulmonary shunt.

Angioplasty, Balloon↗

Fetal cardiac output in the isoimmunized pregnancy: a pulsed Doppler-echocardiographic study of patients undergoing intravascular intrauterine transfusion.

The mechanism of development of hydrops fetalis in severe isoimmunization has been subject to speculation. We performed pulsed Doppler assessment of cardiac output in 13 severely isoimmunized fetuses before and after intravascular transfusion and compared the results with 37 control fetuses between 20 and 34 weeks' gestation. The cardiac index of the anemic fetuses was significantly greater than that of the control group. A significant (right ventricle, p less than 0.01; left ventricle, p less than 0.02) increase in indexed output was noted from both ventricles and in the combined ventricular output (mean +/- SEM 644 +/- 35.3 ml/kg/min in control fetuses versus 879 +/- 86.0 ml/kg/min in anemic fetuses, p less than 0.006). An increase in cardiac output was also noted when anemic fetuses were compared with gestational age-specific norms. We conclude that severely anemic fetuses of isoimmunized pregnancies tend to have significantly higher cardiac output than do unaffected fetuses and that this high output state may play a part in the development of hydrops fetalis.

Blood Transfusion, Intrauterine↗

Thrombus associated with central venous catheters in infants and children.

From 1978 to 1987, 350 infants and children had silicone central catheters placed for long-term venous access. Real time echocardiography showed a catheter tip thrombus in 16 patients, including 12 premature infants and four children. Catheters had been in place for eight to 560 days. Thirteen patients were receiving total parenteral nutrition (TPN) at the time thrombus was identified, and one patient had received TPN 2 weeks previously. Indications for echocardiography included sepsis (7), respiratory insufficiency (6), evaluation of heart disease (3), and catheter malfunction (1); several patients had multiple indications. Treatment was individualized and included atriotomy (2), systemic heparin and thrombolytic agents with or without catheter removal (8), catheter removal only (3), and observation (3). Four of eight patients treated with thrombolysis had complete clot lysis and four had partial dissolution. Two patients managed expectantly had resolution of the thrombus. None of the patients suffered further complications or died as a result of the thrombus, but ten of the 16 died 1 to 12 weeks later from their underlying disease. Forty-seven asymptomatic patients were studied by echocardiography to assess the incidence of unsuspected right atrial thrombus. Their catheters had been in place for a mean of 200 days and only 11 had been used for TPN. None of these patients had identifiable thrombus at the catheter tip. The incidence of catheter tip thrombus, which is higher than previously suspected, is related to prematurity, TPN, and continuous catheter use, but not duration of catheterization. The incidence is low in asymptomatic patients. Treatment regimen must be individualized and this series reflects a trend toward more conservative management.

Catheterization, Central Venous↗

Development of a benign intrapericardial tumor between 20 and 40 weeks of gestation.

A case of a massive benign intrapericardial teratoma that presented at two weeks of age with significant respiratory distress is described. In retrospect, it was discovered that this infant had been evaluated by fetal echocardiography while in utero at 20 weeks of gestation due to a maternal history of surgically corrected tetralogy of Fallot. The fetal echocardiogram demonstrated normal intracardiac anatomy and no evidence of either a pericardial mass or effusion. It is concluded that this tumor spontaneously enlarged some time between 20 and 40 weeks of gestation.

Echocardiography↗

The frequency of aneuploidy in prenatally diagnosed congenital heart disease: an indication for fetal karyotyping.

The frequency of chromosomal abnormalities in infants with congenital heart disease has been estimated from postnatal clinic data to be 5% to 10%. Over an 18-month period we performed fetal echocardiograms on 502 fetuses and found cardiac anomalies in 34. Eleven of these fetuses (32%) had abnormal chromosomes. This marked discrepancy from the data found in the pediatric literature may relate to nonviable fetuses identified in utero, who escape pediatric case identification. We conclude that in cases of fetal heart disease the workup should include either amniocentesis or fetal blood sampling for chromosome analysis. The information can be used for complete parental counseling and for managing delivery and neonatal care.

Aneuploidy↗

Randomized low-dose indomethacin trial for prevention of intraventricular hemorrhage in very low birth weight neonates.

We admitted 36 preterm neonates (600 to 1250 gm birth weight) with normal 6-hour echoencephalograms to a randomized, placebo-controlled prospective trial to determine whether a low dose of indomethacin would prevent germinal matrix or intraventricular hemorrhage and permit adequate urinary output. Between the sixth and tenth postnatal hours, indomethacin (0.1 mg/kg) or placebo was administered intravenously every 24 hours for a total of three doses. Cardiac ultrasound studies to assess the status of the ductus arteriosus were performed at 6 postnatal hours and on day 5. Urinary output, serum electrolytes, serum indomethacin levels, and renal and clotting functions were monitored. No differences in birth weight, gestational age, or Apgar scores were noted between the two groups of infants. Two indomethacin-treated infants and three infants given placebo had significant urinary output difficulties, requiring that the study medication be withheld. Of 19 infants given indomethacin, two had germinal matrix or intraventricular hemorrhage, in comparison with 8 of 17 infants given saline solution (p = 0.02). Of the infants who had a left-to-right patent ductus arteriosus shunt before treatment, 64% of the indomethacin-treated and 33% of the saline solution-treated infants no longer had a patent ductus arteriosus on day 5. Ductal status appeared unrelated to the development of germinal matrix or intraventricular hemorrhage.

Cerebral Hemorrhage↗

Aneurysms of the right ventricular outflow tract after tetralogy of Fallot repair: role of radiology.

Eight patients with aneurysms of the right ventricular outflow tract patch following tetralogy of Fallot repair were found to have residual distal obstructions. The site of such an obstruction must be carefully documented preoperatively because failure to relieve significant distal obstruction may result in recurrent aneurysm formation. Chest radiography; echocardiography, including Doppler analysis; and cardiac catheterization, including angiocardiography, each have a role in the detection and evaluation of this complication.

Angiocardiography↗

Fetal echocardiographic screening for congenital heart disease: the importance of the four-chamber view.

The four-chamber view of the heart has been proposed as a screening method for obstetrical sonographers to assess the fetus for the presence of congenital heart disease. We examined the fetuses in 1022 pregnancies and found 74 structurally abnormal hearts. Seventy-one of these (96%) were found to have an abnormality as seen in the four-chamber view. The four-chamber view of the heart had 92% sensitivity and 99.7% specificity in the detection of congenital heart disease. The positive predictive value was 95.8%, and the negative predictive value was 99.4%. We conclude that the four-chamber view may be a useful screen for the presence of congenital heart disease and should be included as a part of all routine obstetric ultrasound examinations.

Echocardiography↗