PubMed Health⌕ Search

Biomedical subjects

C S Kwok

Publications and source records attributed to C S Kwok.

At least 19 recordsLinked to original sources

Application of high-resolution radiochromic film dosimetry in verifying a small-field stereotactic radiosurgery plan.

A high-resolution radiochromic film dosimetry (Hr-RCFD) method has been applied to verify a small-field stereotactic radiosurgery (SRS) plan. This was done by exposing a RCF in a Perspex head phantom undergoing the same treatment plan as the patient. The dose distribution obtained by the Hr-RCFD was verified against that calculated by the stereotactic treatment planning system and the result was satisfactory. The Hr-RCFD method has been found to be an accurate and practical tool in verifying small-field SRS plans.

Dose-Response Relationship, Radiation↗

Dual-peak dose measurement for radiochromic films by a newly developed spectral microdensitometer.

Radiochromic film (RCF) dosimetry is usually based on densitometric methods which use an analyzing light source of a fixed or a broad spectrum of wavelengths. These methods have not exploited the sensitivity of the dose response of the RCF otherwise attainable by using a light source with wavelengths peaked at the two absorption peaks in the absorption spectrum of the RCF. A new algorithm of dual-peak dose measurement for the RCF has been proposed in this paper to make use of these dual absorption peaks to achieve the maximum attainable sensitivity. This technique relies on the measurement of the transmittance of the RCF at the wavelength of the major and minor absorption peaks, respectively. The dual-peak dose measurement is accomplished with the aid of a novel spectral microdensitometer developed in our Institute. The microdensitometer utilizes a monochromator to provide a light source of which the wavelength can be matched precisely to the wavelength of the absorption peaks of the RCF. The doses obtained at these wavelengths are fed into a weighted objective function and an optimum dose is searched by minimizing the objective function to give the best estimate of the dose deposited on the film. An initial test shows that there is a good agreement between the estimated and actual dose deposited; and the maximum discrepancy was found to be less than 1%.

Algorithms↗

Development and initial evaluation of a spectral microdensitometer for analysing radiochromic films.

Radiation dose deposited on a radiochromic film is considered as a dose image. A precise image extraction system with commensurate capabilities is required to measure the transmittance of the image and translate it to radiation dose. This paper describes the development of a spectral microdensitometer which has been designed to achieve this goal under the conditions of (a) the linearity and sensitivity of the dose response curve of the radiochromic film being highly dependent on the wavelength of the analysing light, and (b) the inherent high spatial resolution of the film. The microdensitometer consists of a monochromator which provides an analysing light of variable wavelength, a film tray on a high-precision scanning stage, a transmission microscope coupled to a thermoelectrically cooled CCD camera, a microcomputer and corresponding interfaces. The measurement of the transmittance of the radiochromic film is made at the two absorption peaks with maximum sensitivities. The high spatial resolution of the instrument, of the order of micrometres, is achieved through the use of the microscope combined with a measure-and-step technique to cover the whole film. The performance of the instrument in regard to the positional accuracy, system reproducibility and dual-peak film calibration was evaluated. The results show that the instrument fulfils the design objective of providing a precise image extraction system for radiochromic films with micrometre spatial resolution and sensitive dose response.

Calibration↗

Self-assembled molecular structures as ultrasonically-responsive barrier membranes for pulsatile drug delivery.

Noninvasive ultrasound has been shown to increase the release rate on demand from drug delivery systems; however, such systems generally suffer from background drug leaching. To address this issue, a drug-containing polymeric monolith coated with a novel ultrasound-responsive coating was developed. A self-assembled molecular structure coating based on relatively impermeable, ordered methylene chains forms an ultrasound-activated on-off switch in controlling drug release on demand, while keeping the drug inside the polymer carrier in the absence of ultrasound. The orderly structure and molecular orientation of these C12 n-alkyl methylene chains on polymeric surfaces resemble self-assembled monolayers on gold. Their preparation and characterization have been published recently (Kwok et al. [Biomacromolecules 2000;1(1):139-148]). Ultrasound release studies showed that a copolymer of 2-hydroxyethyl methacrylate and ethylene glycol dimethacrylate (MW 400) coated with such an ultrasound-responsive membrane maintained sufficient insulin for multiple insulin delivery, compared with a substantial burst release during the first 2 h from uncoated samples. With appropriate surface coating coverage, the background leach rate can be precisely controlled. The biological activity of the insulin releasate was tested by assessing its ability to regulate [C14]-deoxyglucose uptake in 3T3-L1 adipocyte cells in a controlled cell culture environment. Uptake triggered by released insulin was comparable to that of the positive insulin control. The data demonstrate that the released insulin remains active even after the insulin had been exposed to matrix synthesis and the methylene chain coating process.

Adipocytes↗

Gadolinium prevents stretch-mediated contractile dysfunction in isolated papillary muscles.

We tested the hypothesis that overstretching the myocardium could induce and/or exacerbate contractile dysfunction via stretch-activated (SA) ion channels. Maximum developed tension (T(max)), normalized to a control value, was compared in guinea pig papillary muscles held at one of three resting lengths (physiological stretch, overstretch, and unloaded) for 85 min. Overstretched muscles exhibited decreased contractile force (T(max) = 0.77 +/- 0.03) compared with physiological and unloaded muscles (T(max) = 0.93 +/- 0.05 and 1.03 +/- 0.07, respectively). Gd(3+), an SA channel antagonist, eliminated the adverse effect of overstretching (T(max) = 0.98 +/- 0.06), but nifedipine, a dihydropyridine (DHP) antagonist of L-type calcium channels, did not (T(max) = 0.82 +/- 0.04). Exposure to modified hypoxia-reoxygenation (MHR) during physiological stretch resulted in decreased contractility (T(max) = 0.63 +/- 0.07), an effect that was exacerbated by overstretching (T(max) = 0.44 +/- 0.04). Gd(3+) mitigated the effects of overstretch during MHR (T(max) = 0.64 +/- 0.05), but DHP did not (T(max) = 0.48 +/- 0.04). These data suggest that overstretching of the myocardium contributes to contractile abnormalities via SA channels that are distinct from L-type calcium channels.

Animals↗

ROC curve analysis of lesion detectability on phantoms: comparison of digital spot mammography with conventional spot mammography.

Although conventional screen--film mammography has excellent spatial resolution and is commonly used as a screening tool, certain inherent limitations prevent its further improvement. New digital mammography techniques, despite lower spatial resolution than screen--film mammography, may overcome these limitations. This study compared lesion detectability between charge coupled device-based digital spot mammography and conventional spot mammography. A total of 100 sets of images of specially designed breast phantoms was acquired, with variable background achieved by overlapping several layers of grapefruit fibre on a 4 cm thick lucite slab, using both modalities. 75 sets were "normal" images and 25 sets were images with simulated lesions. Four radiologists assessed the images according to a five-point confidence scale. The results were used to construct receiver operating characteristic curves. No statistical difference was observed between the two sets of curves for individual radiologists as well as pooled data. The lower spatial resolution of digital mammography was compensated for by its higher contrast sensitivity relative to conventional spot mammography.

Equipment Design↗

Baby contracts.

Explore the source record for details and available documents.

Contracts↗

Surface modification of polymers with self-assembled molecular structures: multitechnique surface characterization.

A simple, one-step procedure for generating ordered, crystalline methylene chains on polymeric surfaces via urethane linkages was developed. The reaction of dodecyl isocyanate with surface hydroxyl functional groups, catalyzed by dibutyltin dilaurate, formed a predominantly all-trans, crystalline structure on a cross-linked poly(2-hydroxyethyl methacrylate) (pHEMA) substrate. Allophanate side-branching reactions were not observed. Both X-ray photoelectron spectrocopy and time-of-flight secondary ion mass spectrometry show that the surface reaction reached saturation after 30 min at 60 degrees C. Unpolarized Fourier transform infrared-attenuated total reflection showed that, after 30 min, the stretching frequencies, vCH2,asym and vCH2,sym, decreased and approached 2920 and 2850 cm-1, indicative of a crystalline phase. The distance between two hydroxyl groups is roughly 4 A. A tilt angle of 33.5 degrees +/- 2.4 degrees was estimated by dichoric ratios measured in polarized ATR according to the two-phase and Harrick thin film approximations. The findings reported here are significant in that the possibilities for using structures similar to self-assembled monolayers (SAMs) are expanded beyond the rigid gold and silicon surfaces used through most of the literature. Thus, SAMs, biomimetics for ordered lipid cell wall structures, can be applied to real-world biomedical polymers to modify biological interactions. The terminal groups of the SAM-like structure can be further functionalized with biomolecules or antibodies to develop surface-based diagnostics, biosensors, or biomaterials.

Algorithms↗

Monte Carlo simulation of x-ray spectra in mammography.

A model for generating x-ray spectra in mammography is presented. This model used the ITS version 3 Monte Carlo code for simulating the radiation transport. Various target/filter combinations such as tungsten/aluminium, molybdenum/molybdenum, molybdenum/rhodium and rhodium/rhodium were used in the simulation. Both bremsstrahlung and characteristic x-ray production were included in the model. The simulated x-ray emission spectra were compared with two sets of spectra, those of Boone et al (1997 Med. Phys. 24 1863-74) and IPEM report 78. The chi2 test was used for the overall goodness of fit of the spectral data. There is good agreement between the simulated x-ray spectra and the comparison spectra as the test yielded a probability value of nearly 1. When the transmitted x-ray spectra for specific target/filter combinations were generated and compared with a measured molybdenum/rhodium spectrum and spectra generated in IPEM report 78, close agreement is also observed. This was demonstrated by the probability value for the chi2 test being almost 1 for all the cases. However, minor differences between the simulated spectra and the 'standard' ones are observed.

Biophysical Phenomena↗

Chemical conjugation of a novel antibody-interleukin 2 immunoconjugate against c-erbB-2 product.

OBJECTIVE: To develop a new chemical method to produce a monoclonal antibody (MoAb) 520C9/recombinant human interleukin 2 (rhIL-2) conjugate. METHODS: MoAb 520C9 reactive with the protooncogene c-erbB-2 product P185 was chemically conjugated with rhIL-2 by using a simple two-step method. First, the rhIL-2 was activated by Sulfosuccinimidyl 4-[N-maleimidomethyl] cyclohexane-1-carboxylate, a heterobifunctional linker, and N-succinimidyl s-acetylthioacetate was introduced onto 520C9. Then SATA on the 520C9 was reacted with the maleimide group on the activated rhIL-2 to generate 520C9-rhIL-2 immunoconjugate. RESULTS: The immunoconjugate retained the antigen binding activity compared to the respective native antibody as determined by an indirect live cell binding assay. The immunoconjugate also possessed IL-2 activity as measured by the standard CTLL-2 cells proliferation assay and the stimulation of human peripheral blood mononuclear cells (PBMCs) into lymphokine-activated killer cells. CONCLUSION: Our method of conjugation of rhIL-2 to 520C9 preserves the binding activity of the antibody and the cytokine function of IL-2. This simple and efficient method of conjugation should be applicable to other types of MoAbs and recombinant cytokines.

Animals↗

Design of infection-resistant antibiotic-releasing polymers. II. Controlled release of antibiotics through a plasma-deposited thin film barrier.

In the first paper in this series, we described the methods to synthesize an antibacterial polyurethane (PU) incorporating ciprofloxacin as the releasable antibiotic and poly(ethylene glycol) as the pore-forming agent. Here, we report that a thin, RF-plasma-deposited, n-butyl methacrylate (BMA) overlayer on this drug-loaded PU can act as a rate-limiting barrier to achieve a constant, sustained release of ciprofloxacin. Deposition power and deposition time during the coating process were optimized to give an appropriate crosslinked coating barrier that yielded desirable release rates, above the minimum required killing rate, N(kill). Electron spectroscopy for chemical analysis (ESCA), also known as X-ray photoelectron spectroscopy (XPS), was used to characterize the coating, and its crosslinking degree was indirectly related to the C/O ratio. Increasing either deposition power (10-60 W) or duration (5-25 min) resulted in increased C/O ratios and decreased ciprofloxacin release rates. The correlation between increased C/O ratios and reduced release rates is believed to be due to the increased crosslinking, increased hydrophobicity and increased thickness of the coating. The optimal plasma conditions to attain an appropriate crosslinked plasma-deposited film (PDF) required argon etching, pre-treatment of the matrices with an 80W-BMA plasma for 1 min, followed by immediate BMA plasma deposition at 40 W and 150 mT for 20 min. By using these plasma deposition protocols, we eliminated the initial burst effect, significantly reduced the release rates, and closely approached the zero order release kinetics for at least five days. In this study, we also showed that ESCA could be used as a powerful tool to explain the release behavior of molecules through the plasma-deposited films (PDFs).

Anti-Infective Agents↗

Design of infection-resistant antibiotic-releasing polymers: I. Fabrication and formulation.

Biomaterials-related infections are often observed with prosthetic implants and in many cases result in the failure of the devices. To design a biomedically useful polymer that is intrinsically infection-resistant, we have developed a ciprofloxacin-loaded polyurethane (PU) matrix that releases antibiotic locally at the implant surface, thereby minimizing bacterial accumulation. We report here the methods of fabrication and formulation for making such antibiotic-loaded devices, as well as evidence of their bactericidal properties. Specifically, various pore-forming agents and drug loadings were examined. An optimum formulation consisting of BIOSPAN PU, poly(ethylene glycol) and ciprofloxacin offered the longest effective period of sustained release (5 days). The bactericidal efficacy of the released ciprofloxacin against Pseudomonas aeruginosa (PA) was four times that of the control PU without antibiotics. This bactericidal efficiency was due to an increase in the PA detachment from the surface. These observations suggested that the released ciprofloxacin was biologically active in preventing the bacteria from permanently adhering to the substratum, and thus decreasing the possibility of biofilm-related infection.

Anti-Infective Agents↗

Radiolabeling of monoclonal antibody B43.13 with rhenium-188 for immunoradiotherapy.

In this study we report a novel method for direct radiolabeling of monoclonal antibody B43.13 (MAb-B43.13) with 188Re and have evaluated the product's radiochemical, biochemical, immunochemical and selected biological properties. 188Re-MAb-B43.13 was readily prepared by the addition of generator produced perrhenate to a preformulated antibody vial after an optimal amount of supplemental stannous ion, in the form of stannous tartrate, was added. The final radiolabeled product retained its biochemical purity (as determined by size-exclusion HPLC and R/NR-SDS-PAGE), its immunoreactivity (as determined by immunoassay) and presented with a typical stability (in the presence of serum and cysteine) and biodistribution (in tumored mice) profile. The evaluation of the product for immunoradiotherapy of ovarian cancer in a clinical setting requires further studies.

Animals↗

Study of hygroscopic properties of aqueous mixtures of disodium fluorescein and sodium chloride using an electrodynamic balance.

PURPOSE: The purposes of this study are: a) to demonstrate the use of an Electrodynamic Balance (EDB) to investigate the hygroscopic properties of pharmaceutical aerosols; and b) to evaluate the applicability of the Zdanovskii-Stokes-Robinson model (ZSR) in the associated data analysis with multicomponent pharmaceutical aerosols. METHODS: The compositional dependence of the water activity of two model materials commonly employed in the study of pharmaceutical aerosols, namely, NaCl and Disodium Fluorescein (DF), was investigated using an EDB. The water contents of single levitated droplets of NaCl and DF and their mixtures at mass ratios of 1:3, 1:1, 3:1, and 6:1 from dilute concentration to high supersaturation were determined as a function of relative humidity (RH). RESULTS: At decreasing ambient RH, supersaturated aqueous NaCl droplets lose water and crystallize to form dry solid particles at an RH of approximately 50%. Aqueous DF droplet continues to lose water until it reaches a final state containing about 20% by mass of residual water. Mixed solutions of DF and NaCl crystallize at an RH of approximately 50% and then continue to lose water at lower RHs. The resulting "dried" particle still contains water whose amount depends on the mass ratios of DF and NaCl in the mixture. Good prediction of water activity of the DF-NaCl mixture can be achieved with the ZSR model. Collection of a full set of water activity-composition data at each mass ratio of DF-NaCl requires only a few hours. CONCLUSIONS: The EDB, together with the application of the ZSR model in data treatment, appears to be a valuable tool for studying the hygroscopic properties of pharmaceutical aerosols.

Aerosols↗

Effect of recombinant human interleukin 2 on neutrophil adherence to endothelial cells in vitro.

Human neutrophils were demonstrated to possess interleukin-2 receptor (IL-2R) beta and gamma chains, not alpha chain and the binding of IL-2 to the IL-2R beta chain on neutrophils plays an important regulatory role in neutrophil functions. We have investigated in this study the hypothesis that recombinant human IL-2 (rhIL-2) can directly activate human neutrophils and increase their adherence to human umbilical vein endothelial cells (HUVEC). In an in vitro microtiter adherence assay, rhIL-2 significantly stimulated neutrophil adherence to HUVEC in a dose- and time-dependent manner, rhILI-2 concentration at 2000 u/ml and 2 hour incubation gave the best neutrophil stimulation. Treatment of neutrophils with rhIL-2 increased the expression of adhesion molecule CD18. Pretreatment of the stimulated neutrophils with a blocking monoclonal antibody to CD18 decreased but not completely blocked the adherence of neutrophils to HUVEC. These data suggest than rhIL-2 can directly stimulate and increase neutrophil adherence to HUVEC by enhancing the expression of CD18 and possibly other adhesion molecules on neutrophil surface. This may be a critical step in the early stage of the vascular leak syndrome (VLS) associated with high dose IL-2 therapy.

Adult↗

Spatial dose-rate distribution for an 194Ir point source in water.

The spatial dose-rate distribution arising from a unit activity point source of 194Ir embedded in an infinite water medium has been calculated. These results may prove to be both useful and timely; 194Ir is a beta-particle-emitting radionuclide that is a suitable candidate for radioimmunotherapy, and a means for producing it fairly easily has recently been made available. Calculation of the beta-ray dose-rate distribution is based on a new set of monoenergetic electron dose point kernels which are results from an improved Monte Carlo (ETRAN) calculation. The spatial dose-rate distribution for 32P was also calculated and compared with results from the EGS4-PRESTA and ACCEPT Monte Carlo codes. The ETRAN-based distribution agrees with that from EGS4-PRESTA to within 2% out to 3.6 mm from the source, a distance over which 90% of the source energy is deposited. The ETRAN-based distribution also agrees well with that from ACCEPT between 0.6 and 4 mm from the source; at distances < 0.6 mm, values from ACCEPT are about 6% larger than ones calculated here.

Beta Particles↗

Autoradiography-based, three-dimensional calculation of dose rate for murine, human-tumor xenografts.

A Fast Fourier Transform method for calculating the three-dimensional dose rate distribution for murine, human-tumor xenografts is outlined. The required input includes evenly-spaced activity slices which span the tumor. Numerical values in these slices are determined by quantitative 125I autoradiography. For the absorbed dose-rate calculation, we assume the activity from both 131I- and 90Y-labeled radiopharmaceuticals would be distributed as is measured with the 125I label. Two example cases are presented: an ovarian-carcinoma xenograft with an IgG 2ak monoclonal antibody and a neuroblastoma xenograft with meta-iodobenzylguanidine (MIBG). Considering all the volume elements in a tumor, we show, by comparison of histograms and also relative standard deviations, that the measured 125I activity and the calculated 131I dose-rate distributions, are similarly non-uniform and that they are more non-uniform than the calculated 90Y dose-rate distribution. However, the maximum-to-minimum ratio, another measure of non-uniformity, decreases by roughly an order of magnitude from one distribution to the next in the order given above.

Animals↗