Computer-assisted design of butterfly bileaflet valves for the mitral position.

This paper describes the application of computer testing to a design study of butterfly bileaflet mitral prostheses having flat or curved leaflets. The curvature is in the plane normal to the pivot axes and is such that the convex sides of the leaflets face each other when the valve is open. The design parameters considered are the curvature of the leaflets and the location of the pivot points. In this study, stagnation is assessed by computing the smallest value (over the three openings of the valve) of the peak velocity, and hemodynamic performance is judged by a benefit/cost ratio: the net stroke volume divided by the mean transvalvular pressure difference. Unlike the case of a pivoting single-disc valve, the inclusion of a constraint on the maximum angle of opening of the leaflets is found to be essential for adequate, competent performance. Results are presented with both 85 degrees and 90 degrees constraints, since best performance is achieved with the opening-angle constraint in this range. Asymmetry of leaflet motion which is observed with flat leaflets in the mitral position is reduced with modest leaflet curvature. Leaflet curvature also ameliorates central orifice stagnation, which is observed with flat leaflets. Curvature of the valve produces the following improvements in comparison with the best flat valve when the opening-angle constraint is 85 degrees: a 38% increase in the minimum peak velocity and a 16% increase in the hemodynamic benefit/cost ratio. With a 90 degrees constraint the corresponding improvements are 34% and 20%, respectively.

Computers↗

Some unexpected consequences of a simple physical mechanism for voltage-dependent gating in biological membranes.

We consider a model for voltage-dependent gating of channels in which the gating charges are on the channel wall and move only a small distance. When this movement occurs across the closed gate, the charges move through the entire transmembrane potential, which is energetically equivalent to their moving across the entire membrane. The channel exists in two open states, O1 and O2, and two closed states, C1 and C2; each open and closed configuration is divided into two states because of the two possible positions of the gating charges. An unusual property of this model is that the electrical work in going from an open to a closed configuration (for example, in going from O1 to C2) is path dependent, and net work can result from going reversibly around a complete cycle. The model channel, like many biological channels, shows bursting activity. This flickering on and off of the channel enables the gate to sense the electric field and decide if it should be in the open or closed configuration. We prove here some general theorms concerning the electrical work associated with the movements of the walls of channels and the movements of charges on these walls.

Electric Conductivity↗

How to see in the dark: photon noise in vision and nuclear medicine.

This paper is concerned with the construction of optimal filters for smoothing the photon noise that arises under low-light conditions in vision and under low-dose or short-exposure conditions in nuclear medicine. In the case of vision, the paper explores the hypothesis that the retina functions as an optimal filter. The consequences of this hypothesis for light adaptation are studied. In the case of nuclear medicine, a method for constructing optimal filters is introduced, and the method is tested by computer simulation.

Adaptation, Physiological↗

Computer-assisted design of pivoting disc prosthetic mitral valves.

This paper describes the use of the new technique of computer testing to study the simulated performance of flat and curved pivoting disc prosthetic mitral valves. The design parameters considered are the radius of curvature of the occluder and the position of the pivot point. The performance criteria are the net stroke volume, the mean forward pressure difference, and the peak anterior velocity. The last of these criteria may be important in the prevention of small-orifice valve thrombosis. The best overall valve in the study has a radius of curvature equal to 1.5 times the diameter of the occluder and a pivot point located 0.39 mitral-ring diameters from the anterior border of the mitral anulus. The maximum angle of opening of this optimal valve is limited to about 70 degrees by fluid-mechanical forces. Nevertheless, the inclusion of a redundant stop in the mechanical design of the valve is indicated, since the computer experiments also reveal excessive opening and failure to close in valves with nearby parameter values. These studies illustrate the usefulness of computer testing in prosthetic valve design.

Animals↗

Fluid dynamics of the mitral valve: physiological aspects of a mathematical model.

This paper presents a computational method that can be used to study the fluid computational method that can be used to study the fluid dynamics of the natural or prosthetic mitral valve in a computer test chamber with contractile muscular walls that model the left side of the heart. Having solved the equations of motion and predicted the performance of the valve, the computer presents the results in terms of flow patterns (streamlines), pressure-contour plots, and graphs of velocity, pressure, flow, tension, and distance as functions of time. Predicted echocardiograms and phonocardiograms are also generated by the computer. These predictions are compared with the results of animal experiments, and the method is used to study the diastolic role of the chordae tendineae, the pathophysiology of mitral valve prolapse syndrome, and the fluid dynamics of pivoting disc valves. Our results support the hypothesis that the chordae have a functional role during diastole. The results also establish a computer model of mitral prolapse, which should be useful in functional studies of that condition, and show that the position of the pivot point and the curvature of the occluder can have a profound effect on the angle of opening of pivoting disc valves. These studies illustrate the applications of the method in physiology, pathophysiology, and prosthetic valve design.

Animals↗

The kinetics of monazomycin-induced voltage-dependent conductance. I. Proof of the validity of an empirical rate equation.

Monazomycin (a positively-charged, polyene-like antibiotic) induces a strongly voltage-dependent conductance in thin lipid membranes when added to one of the bathing solutions. We show here that the kinetics of conductance changes after a step of membrane potential are only superficially similar to the kinetics of the potassium gating system of squid giant axons, in that the beginning of conductance increases are growth functions of the time, as opposed to power functions of the time. We find that the rate constant (reciprocal of the time constant) of the growth varies with the approximately 2.6 power of the monazomycin concentration. The rate constant also varies exponentially with membrane potential such that an e-fold change is associated with a 10-11 mV change of membrane potential. We show that solutions of a simple differential equation are able to reproduce the actual conductance changes almost exactly. In the accompanying paper (Muller and Peskin. 1981. J. Gen. Physiol. 78:201-229), we derive the differential equation from a molecular model and use the theoretical equation so obtained to investigate the gating current of this system and to predict an interesting form of memory.

Anti-Bacterial Agents↗

The kinetics of monazomycin-induced voltage-dependent conductance. II. Theory and a demonstration of a form of memory.

The empirical differential equation that describes the kinetics of monazomycin-induced voltage-dependent conductance is derived using a standard chemical kinetic formulation and the assumption that monazomycin entry into and exit from the membrane is autocatalytic. The predicted form of gating currents is shown and numerical calculations for this process are made using a range of values for two unmeasured variables. A form of "memory" is then demonstrated, along with the ability of the theoretical equation to explain the nature of the memory.

Anti-Bacterial Agents↗

The aortic sinus vortex.

This paper describes an analytic and a numerical method for the aortic sinus problem. Both methods are based on the dynamics of point vortices, and both exploit a particular conformal mapping from a model aortic sinus to the upper half plane. The analytic description is based on an isolated point vortex in equilibrium with a free stream. This inviscid model is used to study the stability of the aortic sinus vortex and to elucidate the mechanism of aortic valve closure, but it cannot be used to study the formation of the sinus vortex and it gives a somewhat incorrect picture of the flow pattern. These difficulties are overcome by the introduction of a numerical method for the aortic sinus problem with fluid viscosity. We use Chorin's vortex method combined with conformal mapping. The conformal mapping approach gives an explicit formula for the vortex velocities and it resolves the singularities associated with the corners of the domain. This method is then used to study the formation of the sinus vortex and to confirm the predictions of the point vortex model with respect to the role of the vortex in valve closure.

Animals↗

Numerical simulation and experimental validation of blood flow in arteries with structured-tree outflow conditions.

Blood flow in the large systemic arteries is modeled using one-dimensional equations derived from the axisymmetric Navier-Stokes equations for flow in compliant and tapering vessels. The arterial tree is truncated after the first few generations of large arteries with the remaining small arteries and arterioles providing outflow boundary conditions for the large arteries. By modeling the small arteries and arterioles as a structured tree, a semi-analytical approach based on a linearized version of the governing equations can be used to derive an expression for the root impedance of the structured tree in the frequency domain. In the time domain, this provides the proper outflow boundary condition. The structured tree is a binary asymmetric tree in which the radii of the daughter vessels are scaled linearly with the radius of the parent vessel. Blood flow and pressure in the large vessels are computed as functions of time and axial distance within each of the arteries. Comparison between the simulations and magnetic resonance measurements in the ascending aorta and nine peripheral locations in one individual shows excellent agreement between the two.

Adult↗