The dosimetric effects of tissue heterogeneities in intensity-modulated radiation therapy (IMRT) of the head and neck.

The dosimetric effects of bone and air heterogeneities in head and neck IMRT treatments were quantified. An anthropomorphic RANDO phantom was CT-scanned with 16 thermoluminescent dosimeter (TLD) chips placed in and around the target volume. A standard IMRT plan generated with CORVUS was used to irradiate the phantom five times. On average, measured dose was 5.1% higher than calculated dose. Measurements were higher by 7.1% near the heterogeneities and by 2.6% in tissue. The dose difference between measurement and calculation was outside the 95% measurement confidence interval for six TLDs. Using CORVUS' heterogeneity correction algorithm, the average difference between measured and calculated doses decreased by 1.8% near the heterogeneities and by 0.7% in tissue. Furthermore, dose differences lying outside the 95% confidence interval were eliminated for five of the six TLDs. TLD doses recalculated by Pinnacle3's convolution/superposition algorithm were consistently higher than CORVUS doses, a trend that matched our measured results. These results indicate that the dosimetric effects of air cavities are larger than those of bone heterogeneities, thereby leading to a higher delivered dose compared to CORVUS calculations. More sophisticated algorithms such as convolution/superposition or Monte Carlo should be used for accurate tailoring of IMRT dose in head and neck tumours.

Air↗

Experimental determination of the overall perturbation factor for the NACP chamber in electron beams for dmax < d < or = d80.

In electron beam dosimetry with an ionization chamber, a factor that corrects for the cavity perturbation of the medium, Prepl, and one to account for the disturbance due to the chamber wall material differing from the medium, Pwall, are required. The overall perturbation correction factor, p(q) = PreplPwall, has been introduced because of the difficulty in separately measuring these two components. An advantage of parallel-plate ionization chambers is that p(q) has been shown to be close to unity at dmax. However, many dosimetry applications require knowledge of the overall perturbation factor at depths greater than dmax. We determined p(q) for the NACP chamber at depths beyond dmax by intercomparing percentage depth dose measurements made with it with those obtained with a PTW/diamond detector for which p(q) was taken as unity at all the measurement depths. Data were obtained at depths corresponding to approximately the 90 and 80 per cent of the dose maxima for 20, 16, 12 and 6 MeV incident electrons. The beam energy at depth, Ed, and the percentage depth-dose gradient varied from 1.4 to 14.3 MeV and 0 to 5.8% mm(-1) respectively. Our results show that within the estimated uncertainty of 1.3%, p(q),NACP is unity over the range of energies and dose gradients studied.

Biophysical Phenomena↗

Evaluation of the contribution of capture gamma rays, x-ray leakage, and scatter to the photon dose at the maze door for a high energy medical electron accelerator using a Monte Carlo particle transport code.

A Monte Carlo simulation of the photon dose due to scattered x rays, head leakage photons, and capture gamma rays in the maze of an 18 MeV accelerator facility was carried out. The results of the Monte Carlo simulation were compared with dose measurements made in the maze and also with values calculated using an empirical equation. Agreement within +/-26% was found among the three techniques used to evaluate the capture gamma ray dose. It was found that the empirical equation overestimated the scattered x ray plus head leakage photon dose by a factor as large as 2.9 as compared to the other methods. It was concluded that the photon dose, for mazes greater than 3 m in length, is produced predominately by capture gamma rays.

Biophysical Phenomena↗

Measured overall perturbation factors at depths greater than dmax for ionization chambers in electron beams.

In electron beam dosimetry the perturbation effect in the medium by the ionization chamber cavity is accounted for by introducing a replacement correction factor, P(repl). Another perturbation correction factor, denoted as P(wall), is due to the materials of the walls of the parallel-plate chamber differing from the phantom material. Because of the difficulties in separating these two components, we measure the overall perturbation factor, p(q) = P(repl)P(wall). A distinct advantage of parallel-plate ionization chambers over cylindrical chambers is that p(q) has been shown to be close to unity at the standard calibration depth, d(max). However, for many dosimetry applications it is necessary to know the overall perturbation factor at depths greater than d(max). We measured the overall perturbation factor at depths greater than d(max) (approximating the 95%, 90% and 50% depth dose) for a Farmer-type cylindrical ionization chamber and three parallel-plate ionization chambers. We assumed that p(q) for the NACP chamber is unity at these measurement depths. The depth dependence for the other chambers was then measured relative to the NACP chamber. The mean energy at depth, E(d), and percentage depth dose gradient ranges studied were 1.9-18.5 MeV and 0 to 4.5%/mm, respectively. For the other two parallel-plate chambers, we find p(q) to be unity at depths where the percent depth dose is greater than 90%, but it deviates from unity at deeper depths, where the dose gradients exceed about 2.5%/mm. For the cylindrical chamber, p(q) values at depths greater than d(max) were found to be in good agreement with those in TG 21, where the energy at depth, E(d), is used to evaluate p(q).

Calibration↗

A comparison of methods for calibrating parallel-plate chambers/.

All dosimetry protocols for calibrating the output of electron beams recommend the use of parallel-plate ionization chambers, but the method of determining their value of Ngas is a matter of concern. The AAPM Protocol (TG 21) recommends a direct comparison with a calibrated cylindrical chamber in phantom at dmax with the highest available electron energy beam. This must be done by the user. Since all calibration laboratories traditionally use 60Co for megavoltage chamber calibrations, two alternate procedures based on exposures in-air, or in-phantom, have been proposed. All methods use correction factors in the data reduction. To verify the consistency of the three methods, we have measured Ngas using each of these techniques for six of the most commonly used and commercially-available parallel-plate ionization chambers. The paired cylindrical and parallel-plate ionization chambers, and phantom materials/buildup caps were matched to the wall composition of the plane chambers, as recommended in TG 39. A 22 MeV electron beam was used for the electron irradiations. The ionization chambers were then taken to an Accredited Dosimetry Calibration Laboratory (ADCL), where 60Co calibrations were performed. The results demonstrate that, by using the appropriate correction factors for the chambers described in this work, all three methods yield values for Ngas that are within 1% of each other.

Biophysical Phenomena↗

3-D treatment planning and dose delivery verification integrating a variety of state-of-the-art techniques: a case report.

A patient previously treated with radiation for base-of-tongue cancer presented with recurrent disease seven years later. The spinal cord had received tolerance dose. Using state-of-the-art treatment planning techniques, including beam's-eye-view and volumetrics, dose-volume histograms, split field technique, mixed energies, and beam intensity modulation (with a compensator), we achieved uniform dose coverage of the target in 3-D. This was verified in vivo with thermoluminescence dosimeters positioned in the esophagus by means of a nasogastric tube that ran centrally through the target volume. The various techniques applied will be presented with a discussion of the rationale used in each step of plan optimization and verification.

Image Processing, Computer-Assisted↗

Determination of the source position for the electron beams from a high-energy linear accelerator.

We have investigated the energy and field-size dependence of the source position of the electron beams from a Varian Clinac-2,500 accelerator. Three independent experimental methods were used: (1) multipinhole camera (MPC), (2) back projection of the full width at half maximum (FWHM), and (3) the inverse square law (ISL). The positions of the virtual and effective sources were calculated using the multiple Coulomb scattering (MCS) formalism. The results obtained from the MPC agree, within the experimental uncertainties, with the calculated values for the virtual source position. Similarly, the results from the FWHM method agree with the calculations with the exception of those for small field sizes at the lower energies. This is consistent with the fact that both kinds of measurements are not very sensitive to scattering in the photon and electron collimators. In contrast, the source position determined by the ISL method shows strong dependence on field size and energy, and does not agree with the values predicted by the MCS formalism. This is due to contamination from electrons scattered in the x ray and electron collimation system. The techniques and results reported here should be generally applicable to other scatter foil linear accelerators.

Electrons↗

Characteristic parameters of 6-22 MeV electron beams from a 25-MeV linear accelerator.

Depth-ionization measurements were performed using a thin wall parallel plate chamber in water at nominal electron energies of 6, 9, 12, 15, 18, and 22 MeV for the standard available square field sizes. The characteristic parameters of the central axis depth-dose distributions were derived and compared to corresponding values for other accelerators. Vacuum packed therapy-verification films were used in water to obtain isodose distributions in a plane containing the central axis of the beam. The uniformity index and penumbra of the beams were measured from isodose distributions obtained in planes perpendicular to the beam central axis, at depths of 1/2R85 in water.

Electrons↗

Output calibration in solid water for high energy photon beams.

The AAPM Protocol recommends the use of water, polystyrene or acrylic media for measuring the output of high energy photon beams. It provides the appropriate restricted mass stopping powers and mass energy absorption coefficients for converting the dose to these media to dose to water. A water-equivalent solid has been developed for dosimetric applications [C. Constantinou, F. Attix, and B. Paliwal, Med. Phys. 9, 436 (1982)]. Calculated values for the restricted mass stopping powers and mass energy absorption coefficients have been published for this material [A. Ho and B. Paliwal, Med. Phys. 13, 403 (1986)]. The accuracy of these calculations was investigated by making output measurements, following the Protocol, with a Farmer type chamber in four materials for Co-60, 4, 6, 10, 18, and 24 MV photon beams. The results show that the scaled dose to water for the different media agree to better than 1%, and the analysis supports the methodology of the Protocol for obtaining the dose to water from the different media.

Calibration↗

Dosimetry of Sr-90 ophthalmic applicators.

Sr-90 ophthalmic applicators are commonly used for the treatment of superficial eye disorders. Although a variety of dosimetric devices such as film, thermoluminescent dosimeters (TLD's), ion chambers, and radiochromic foils have been used to measure the peak dose at the applicator surface, there is no internationally agreed upon calibration procedure. Recently, large discrepancies among calibrations of the same applicator at three institutions have been reported. Here we describe a technique to obtain the peak dose rate at the applicator surface using LiF TLD's. The technique can be used for the calibration of flat as well as curved surface applicators. Results for two flat and three concave applicators are presented. Our measurement of the surface dose rate for one of the flat applicators is compared with those obtained by four other institutions, each using different dosimetric devices.

Calibration↗

Measurement of the replacement correction factor for parallel-plate chambers in electron fields.

When parallel-plate chambers are used for dosimetry in electron fields, the AAPM dosimetry protocol recommends a value of 1.0 for the replacement correction factor, P(repl),pp,E, until further data become available. Here, P(repl),pp,E for five commercially available parallel-plate chambers was measured as a function of electron energy from a nominal value of 5.5 to 22 MeV by comparison with a cylindrical chamber whose P(repl),cyl,E was obtained from data in the protocol. Since this method is based on the concept of a constant value for Ngas,pp, the energy and modality dependence of Ngap,pp is also investigated for these chambers for Co-60, 4-, 6-, 24-MV photons and for 22-MeV electrons. It is found that for three of the chambers P(repl),pp,E is independent of energy, consistent with unity within one or two standard deviations (s.d.). For the fourth chamber P(repl),pp,E is similarly consistent with one above 10 MeV, but decreases at lower energies, while for the fifth one it shows a systematic drop with decreasing energy.

Calibration↗

Experimental determination of fluence perturbation factors for five parallel-plate ionization chambers.

The calibration of parallel-plate chambers for absolute dosimetry is an unsettled matter. The medical physics community has not yet agreed on a practical method of obtaining Ngas, although several researchers are working on this problem. If the photon and electron fluence perturbation factors, KwallKcomp, were known for chambers of standard construction with full buildup provision, then an in-air Co-60 calibration could be applied to these, as is done with cylindrical chambers. We have obtained such correction factors for five commercially available chambers based on measurements in air and in homogeneous phantoms relative to matched cylindrical chambers of known dosimetric parameters. For three of the chambers (Markus, Holt and Exradin) we find that KwallKcomp = 1.000 +/- 0.008, in excellent agreement with available results from Monte Carlo calculations. The values for the other two chambers (NACP and Capintec) are different than 1. Our results are compared to recently published values, both calculated and measured.

Calibration↗