PubMed Health⌕ Search

Biomedical subjects

C Sachs

Publications and source records attributed to C Sachs.

At least 19 recordsLinked to original sources

Experimental investigation of the elastic-plastic deformation of mineralized lobster cuticle by digital image correlation.

This study presents a novel experimental approach to the characterization of the deformation of a mineralized biological composite using arthropod cuticle as a model material. By performing tensile tests combined with a detailed strain analysis via digital image correlation, the elastic-plastic deformation behavior of the endocuticle of the American lobster Homarus americanus is examined. The test specimens originate from the pincher and crusher claws. For evaluating the effect of moisture on the deformation behavior, the samples are tested both in dry and in wet state. Sample characterization using the digital image correlation method requires a stochastic spot pattern on the sample surface. Digital images are then taken at subsequent deformation stages during the mechanical test. These images are used to calculate the displacement, the displacement gradient, and the strain fields via pattern correlation. The method is applied both, at a global scale to measure with high precision the stress-strain behavior of the bulk cuticle and at a microscopic scale to reveal strain heterogeneity, strain patterning, and strain localization phenomena.

Animals↗

Sex-specific fetal weight prediction by ultrasound.

OBJECTIVE: To improve sonographic birth-weight prediction by developing fetal gender-specific formulae. METHODS: This was a retrospective cross-sectional study. Two gender-specific formulae were produced from the data of 527 patients and the data of a further 349 patients were used to evaluate the formulae. Inclusion criteria were a singleton live fetus, gestational age above 25 weeks, birth weight between 1000 g and 4500 g and fetal biometry within 8 days of delivery. Data retrieval was specifically for the purpose of this study. RESULTS: To yield the best-fit weight formula for each fetal gender we employed step-wise regression analysis based on fractional polynomials with the biometric parameters biparietal diameter (BPD), head circumference (HC), transverse abdominal diameter (TAD), abdominal circumference (AC) and femur length (FL): estimated fetal weight for girls (g) = - 4035.275 + 1.143 x BPD3 + 1159.878 x AC1/2 + 10.079 x FL3 - 81.277 x FL2 [in cm]; estimated fetal weight for boys (g) = 43576.579 + 1913.853 x log10BPD + 0.01323 x HC3 + 55.532 x AC2 - 13602.664 x AC1/2 - 0.721 x AC3 + 2.31 x FL3 [in cm]. These formulae showed superior results compared with those of conventional weight formulae. CONCLUSION: Gender-related fetal weight calculation allows optimized prediction of fetal weight at birth.

Adolescent↗

Spatiotemporal self-organization in a surface reaction: from the atomic to the mesoscopic scale.

Scanning tunneling microscopy data revealed the atomic processes in propagating reaction fronts that occur in the catalytic oxidation of hydrogen on Pt(111). The fronts were also characterized on mesoscopic length scales with respect to their velocity and width. Simulations on the basis of a reaction-diffusion model reproduce the experimental findings qualitatively well. The quantitative comparison reveals the limitations of this traditional approach to modeling spatiotemporal pattern formation in nonlinear dynamics.

Journal Article↗

Health care providers' missed opportunities for preventing femicide.

BACKGROUND: Homicide of women (femicide) by intimate partners is the most serious form of violence against women. The purpose of this analysis of a larger multisite study was to describe health care use in the year prior to murder of women by their intimate partner in order to identify opportunities for intervention to prevent femicide. METHODS: A sample of femicide cases was identified from police or medical examiner records. Participants (n = 311) were proxy informants (most often female family members) of victims of intimate partner femicide from 11 U.S. cities. Information about prior domestic abuse and use of health care and other helping agencies for victims and perpetrators was obtained during structured telephone interviews. RESULTS: Most victims had been abused by their partners (66%) and had used health care agencies for either injury or physical or mental health problems (41%). Among women who had been pregnant during the relationship, 23% were beaten by partners during pregnancy. Among perpetrators with fair or poor physical health, 53% had contact with physicians and 15% with fair or poor mental health had seen a doctor about their mental health problem. Among perpetrators with substance problems, 5.4% had used alcohol treatment programs and 5.7% had used drug treatment programs. CONCLUSIONS: Frequent contacts with helping agencies by victims and perpetrators represent opportunities for the prevention of femicide by health care providers.

Adolescent↗

Recommendations for measurement of and conventions for reporting sodium and potassium by ion-selective electrodes in undiluted serum, plasma or whole blood. International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). IFCC Scientific Division Working Group on Selective Electrodes.

Ion-selective electrodes (ISEs) respond to ion-activity and therefore do not sense substance concentration directly. However, it is recognized that sodium and potassium in plasma will continue to be expressed for clinical purposes in terms of substance concentration (mmol/l). A convention is proposed whereby for routine clinical purposes results of ISE measurements of sodium and potassium in undiluted plasma should be reported in terms of substance concentration (mmol/l). In specimens with normal concentrations of plasma water, total CO2, lipids, protein and pH, the values will concur with the total substance concentration as determined for example by flame atomic emission spectrometry (FAES) or ISE measurements on diluted samples. In specimens with abnormal concentrations of plasma water, the results will differ. However, under these circumstances, measurements of sodium and potassium by ISE in the undiluted sample will more appropriately reflect the activity of sodium and potassium and are therefore clinically more relevant than the determination in diluted samples. Detailed recommendations are made about practical procedures to achieve this. The recommended name for this quantity is the substance concentration of ionized sodium or ionized potassium in plasma, as opposed to total sodium or total potassium determined by, e.g. FAES, or ISE measurements on diluted samples.

Calibration↗

IFCC recommended reference method for the determination of the substance concentration of ionized calcium in undiluted serum, plasma or whole blood.

A reference method is described for the determination of the substance concentration of ionized calcium in plasma by which ionized calcium (free or unbound) may be reliably determined on the basis of calibration with aqueous solutions with known concentration of ionized calcium. The composition of the calibration solutions is chosen such that the activity coefficient of the calcium ion is assumed to be identical both in the calibration solutions and in "normal" plasma, i.e. by convention, the ionic strength (Im) is 0.160 mol/kg. The convention is adopted of reporting ionized calcium measurements as concentration expressed as mmol/l. The proposed reference method for ionized calcium measurement in plasma is based on the use of a cell consisting of an external reference electrode with a saturated potassium chloride liquid/liquid junction in combination with a calcium ion-selective membrane electrode of defined construction and performance. Procedures for using the reference cell and a protocol for sample measurement are described. The preparation of the calibration solutions to be used are described in detail in Appendix A, secondary calibration solutions and check standards in Appendix B, and reference cell vessel design in Appendix C.

Blood↗

Pulse oximetry as a fifth vital sign in emergency geriatric assessment.

OBJECTIVE: To determine the utility of pulse oximetry as a routine fifth vital sign in emergency geriatric assessment. METHODS: Prospective study using pulse oximetry to measure O2 saturation in geriatric patients presenting to ED triage. Saturation values were disclosed to clinicians only after they had completed medical evaluations and were ready to release or admit each patient. The authors measured changes in medical management and diagnoses initiated after the disclosure of pulse oximetry values. The study included 1,963 consecutive adults aged > or = 65 years presenting to triage at a university ED. Measurements included changes in select diagnostic tests: chest radiography, complete blood count (CBC), spirometry, arterial blood gases (ABGs), pulse oximetry, and ventilation-perfusion scans; treatments: antibiotics, beta-agonists, and supplemental O2; and hospital admission and final diagnoses that occurred after complete ED evaluation when physicians were informed of triage pulse oximetry values. RESULTS: 397 (20.2%) geriatric patients had triage pulse oximetry values <95%. Physicians ordered repeat oximetry for 51 patients, additional chest radiography for 23, CBC for 16, ABGs for 15, spirometry for 5, and ventilation-perfusion scans for none. Physicians ordered 49 new therapies for 44 patients, including antibiotics for 14, supplemental O2 for 29, and beta-agonists for 6. Nine patients initially scheduled for ED release were subsequently admitted to the hospital. Physicians changed or added diagnoses for 27 patients. CONCLUSIONS: Using pulse oximetry as a routine fifth vital sign resulted in important changes in the diagnoses and treatments of a small proportion of emergency geriatric patients.

Aged↗

Nitric oxide and the renin angiotensin system: contributions to blood pressure in the young rat.

The present study was designed to investigate the effects of chronic administration of the arginine analogue L-Name (50 mg/kg body weight), the angiotensin converting enzyme inhibitor, perindopril (2 mg/kg body weight), and perindopril (2 mg/kg) plus L-Name (50 mg/kg) on blood pressure, plasma renin activity, plasma angiotensinogen, and hepatic angiotensinogen mRNA levels in young and adult rats. The drugs were given daily from birth to day 21 to puppies and for 15 days to adults. Analytical procedures were performed on day 21 for the puppies and at 10 weeks for the adults. In puppies, blood pressure did not change with L-Name, it decreased to 45% of control values (P < 0.001) with perindopril, and decreased to 77% of control values (P < 0.05) with perindopril plus L-Name. In adults, blood pressure increased to 129% of control values (P < 0.02) with L-Name, decreased to 80% of control values (P < 0.05) with perindopril, and did not change with perindopril plus L-Name. Compared with controls, plasma renin activity was unchanged in puppies and adults with L-Name, undetectable in puppies and slightly increased in adults with perindopril, undetectable in puppies and slightly decreased in adults with perindopril plus L-Name. With L-Name, angiotensinogen mRNA levels were unchanged in puppies and slightly increased in adults, while plasma angiotensinogen levels were decreased (P < 0.05) in puppies and increased (P < 0.01) in adults; with perindopril, angiotensinogen mRNA levels were unchanged in puppies and slightly decreased in adults, while plasma angiotensinogen levels were undetectable in puppies and decreased (P < 0.05) in adults; with perindopril plus L-Name, angiotensinogen mRNA levels were unchanged in puppies while plasma angiotensinogen levels were undetectable in puppies and decreased (P < 0.01) in adults. This study suggests that during the early postnatal period (1) nitric oxide does not exert a basal vasodilator tone but contributes to the hypotensive state induced by perindopril, (2) angiotensin II is essential to maintain blood pressure, (3) and angiotensinogen mRNA levels are not influenced by nitric oxide or angiotensin II.

Angiotensin-Converting Enzyme Inhibitors↗

Pulse oximetry as a fifth pediatric vital sign.

PURPOSE: To determine the utility of pulse oximetry as a routine fifth vital sign in acute pediatric assessment. DESIGN: Prospective study using pulse oximetry to measure oxygen saturation in children presenting to emergency department triage. Saturation values were disclosed to clinicians only after they had completed medical evaluations and were ready to discharge or admit each child. We measured changes in medical treatment and diagnoses initiated after the disclosure of pulse oximetry values. SETTING AND PARTICIPANTS: The study included 2127 consecutive children presenting to triage at a university emergency department. MEASUREMENTS: Changes in select diagnostic tests: chest radiography, complete blood count, spirometry, arterial blood gases, pulse oximetry, and ventilation-perfusion scans; treatments: antibiotics, beta-agonists, supplemental oxygen; and hospital admission and final diagnoses that occurred after disclosure of triage pulse oximetry values. RESULTS: Of 305 children having triage pulse oximetry values less than 95%, physicians ordered second oximetry for 49, additional chest radiography for 16, complete blood counts for 7, arterial blood gas measurements for 4, spirometry for 2, and ventilation-perfusion scans for 2. Physicians ordered 39 new therapies for 33 patients, including antibiotics for 15, supplemental oxygen for 11, and beta-agonists for 8. Five patients initially scheduled for hospital discharge were subsequently admitted. Physicians changed or added diagnoses in 25 patients. CONCLUSIONS: Using pulse oximetry as a routine fifth vital sign resulted in important changes in the treatment of a small proportion of pediatric patients.

Adolescent↗

The European Register for Clinical Chemists. (European Communities Confederation of Clinical Chemistry, Working Group on Registration).

To ensure freedom of movement in the European Union, a limited number of professions is regulated by a so-called Sectorial Directive; all other disciplines, including clinical chemistry, fall under a General Directive. However, clinical chemists in the EU wish their specialty to be more specifically regulated; this means that common standards of education, training, experience and compliance with continuing professional developments must be guaranteed. Therefore, the European Communities Confederation of Clinical Chemistry (EC4) is about to implement the European Register for clinical chemists, and has composed a guide to this Register. The document describes the conditions for entry to specialty training, the minimum standards for registration (university education and postgraduate vocational training with a minimum total of eight years), the competencies of those qualifying for registration, and the operation of the register. Registration guarantees professional and managerial competencies; the title conferred is "European Clinical Chemist". EC4 recognises the existing national registers as far as they are based on the minimal requirements as indicated. An EC4 Register Commission (EC4RC) will maintain and control the European Register, supported by National Clinical Chemistry Registration Committees (NCCRC). An NCCRC controls the quality of the education in each country and assesses candidates. An individual (EU citizen or non-EU citizen trained in an EU country) applies privately for the European Register to EC4RC and, where applicable, the application is accompanied by a document from the NCCRC of the country of registration, stating that the applicant has the necessary qualifications. For EU citizens trained outside the EU the final decision is with EC4RC; non-EU citizens not trained in an EU country are not eligible for registration. Registration is renewed once every five years.

Chemistry, Clinical↗

A comparison of pulse oximetry and respiratory rate in patient screening.

OBJECTIVE: To examine how well respiratory rate correlates with arterial oxygen saturation status as measured by pulse oximetry, and determine whether respiratory rate measurements detect oxygen desaturation reliably. METHODS: Respiratory rate (RR) and oxygen saturation (SaO2) were measured prospectively on 12,096 consecutive adult emergency department triage patients at a university medical center. Respiratory rate was measured by counting ausculated breath sounds for 1 min. Pulse oximetry was used to measure SaO2. Measurements were analysed by age (with one group for 18-19 year olds, groups for every 10 yr from age 20 to age 60, and groups for every 5 yr for subsequent ages). Pearson correlation coefficients were calculated for each age group as well as the weighted average coefficient. Cases having oxygen saturation below 90% were examined to determine how frequently they exhibited increased RR (increased RRs were defined as any rate in the upper five percentile by age. RESULTS: Correlation coefficients ranged from 0.379 to -0.465 with a weighted mean of -0.160. Coefficients for ages 18 through 70 years (representing 10,740 patients) all had magnitude < 0.252. Overall, only 33% of subjects with oxygen saturation below 90% exhibited increased RR. CONCLUSIONS: Respiratory rate measurements correlate poorly with oxygen saturation measurements and do not screen reliably for desaturation. Patients with low SaO2 do not usually exhibit increased RR. Similarly, increased RR is unlikely to reflect desaturation.

Adolescent↗

Evaluation of syringes for ionized calcium measurements.

UNLABELLED: Commercially available ready to use syringes (Radiometer, Sarstedt, Ciba-Corning and Portex), containing heparinate as an anticoagulant have been tested to evaluate the magnitude of induced preanalytical errors. Tonometered serum pools adjusted to four Ca2+ concentrations were sampled anaerobically. MEASUREMENTS: Ca2+ and pH (ICA2 with 3 digits, Radiometer Medical A/S, Denmark; Heparin: anti-Xa factor activity on a chromogenic substrate. Results were expressed as means of 10 measurements and as percentages of the reference values. Sarstedt syringes, (Li-heparinate), yielded a negative bias (-3%). However for 0.5 or 1 mL samples the bias reached -4% to -6%. Radiometer syringes (QS50 and QS90; calcium titrated heparinate) demonstrated biases below -2%. The bias in the Ciba-Corning (Gas-Lyte) syringe was below 2%. Portex (Pulsator) syringes showed biases above +4% even for nominal sampling volumes. All syringes (except Pulsator) released anticoagulant amounts corresponding to the expected values. Radiometer and Ciba-Corning were the only recommendable devices.

Anticoagulants↗

Fetal urinary insulin-like growth factor I and binding protein 3 in bilateral obstructive uropathies.

Fetal urinary concentrations of insulin-like growth factor I (UIGF-I) and binding protein 3 (UIGFBP-3) were determined in patients with prenatal diagnosis of bilateral obstructive uropathy. Patients were retrospectively assigned to three groups, on the basis of outcome: group 1, termination of pregnancies (n = 11) with sonographic evidence of severe oligohydramnios or renal dysplasia, confirmed at histological examination; group 2, patients (n = 10) with postnatal plasma creatinine > 50 mumol/l at the age of 1 year (1 yr-pCreat); and group 3, patients (n = 16) with 1 yr-pCreat < or = mumol/l. The results show a significant increase in UIGF-I and UIGFBP-3 in groups 1 (18,159 +/- 9083 pg/ml; 2657 +/- 669 ng/ml) and 2 (1574 +/- 847 pg/ml; 176 +/- 50 ng/ml) in comparison with group 3 (35 +/- 6 pg/ml; 21 +/- 2 ng/ml). UIGF-I and UIGFBP-3 were significantly correlated with postnatal plasma creatinine, and were both sensitive (90 per cent; 80 per cent) and specific (88 per cent; 88 per cent) for prediction of elevated 1 yr-pCreat (> 50 mumol/l). Fetal urinary IGF-I and IGFBP-3 are increased in severe fetal bilateral obstructive uropathy, possibly reflecting tubular dysfunction or/and increased synthesis consequent upon fetal kidney injury. Their predictive value for postnatal renal function needs further assessment.

Electrolytes↗

Mechanisms of dopamine effects on Na-K-ATPase activity in Madin-Darby canine kidney (MDCK) epithelial cells.

Dopamine decreases tubular sodium reabsorption, attributed in part to Na-K-ATPase inhibition in the proximal convoluted tubule (PCT). Because the final regulation of sodium excretion occurs in the collecting duct, where specific dopamine DA1 binding sites have been demonstrated, we examined the effects of dopamine, as well as of DA1 and DA2 receptor agonists on Na-K-ATPase activity and on the number of units in Madin-Darby canine kidney (MDCK) cells, which retain differentiated properties of the renal cortical collecting tubule epithelium. Dopamine (10(-5) M) inhibited pump activity (by 50%) and reduced the number of units. This effect was reproduced by the DA1 agonist SKF 38393, which inhibited pump activity in a dose- and time-dependent manner (maximum, 10(-5) M). The DA2 agonist quinpirole hydrochloride was without effect, either alone or in combination with SKF 38393. Inhibition of pump activity by dopamine was totally abolished by H7 (100 microM), an inhibitor of protein kinase (PK), but partially by 2',5'-dideoxy-adenosine (DDA) and H4, respective inhibitors of cAMP production and PKA, which suggests that the dopamine effect on Na-K-ATPase activity may be linked to activation of both PKC and PKA. In these cells, amiloride addition during preincubation did not alter the effect of dopamine on Na-K-ATPase activity; in contrast, furosemide increased further the inhibitory effect of dopamine on the enzyme activity. Monensin addition (10(-3) M) reversed the inhibitory effect of dopamine after a 30-min preincubation.(ABSTRACT TRUNCATED AT 250 WORDS)

1-(5-Isoquinolinesulfonyl)-2-Methylpiperazine↗

Deleterious effects of inhibition of the renin-angiotensin system in neonatal rats.

The angiotensin I converting enzyme inhibitor (ACEI) perindopril (2 mg/kg body weight), the peripheral vasodilator dihydralazine (DHL) (25 mg/kg body weight) or distilled water was given daily from birth to day 14 to neonatal rats. Blood pressure, plasma creatinine, plasma renin activity (PRA), substrate (PRS) and concentration (PRC) and renin content of kidney tissue sections were evaluated on days 14 and 28. By day 14, a high mortality in the ACEI group was observed. ACEI, but not DHL, led to a significant fall (P < 0.01) in blood pressure, 57 +/- 11 versus 89 +/- 25 in the DHL group and 103 +/- 24 mmHg in controls, and to a dramatic increase in plasma creatinine. PRA and PRS were undetectable in ACEI-treated rats; in contrast, PRC and renal staining with anti-renin antibody were significantly increased in ACEI rats. On day 28, the blood pressure was normal in all groups and plasma creatinine returned to the normal range in ACEI rats. PRA, PRS and PRC were not significantly different in the ACEI group and controls. These results suggest that the renin-angiotensin system (RAS) plays a major postnatal role in the neonatal rat. Inhibition of the RAS during the first 2 weeks of life leads to high mortality, severe hypotension, reversible renal failure and a defect in circulating angiotensinogen.

Aging↗