PubMed Health⌕ Search

Biomedical subjects

C Scarfone

Publications and source records attributed to C Scarfone.

7 recordsLinked to original sources

Targeting drug delivery to radiation-induced neoantigens in tumor microvasculature.

Radiation can be used to guide drugs to specific sites such as neoplasms or aberrant blood vessels. When blood vessels are treated with ionizing radiation, they respond by expressing a number of cell adhesion molecules and receptors that participate in homeostasis. Examples of radiation-induced molecules in blood vessels include ICAM-1, E-selectin, P-selectin and the beta(3) integrin. We have observed that the endothelium and blood components respond to oxidative stress in a similar, if not identical manner in all tumor models. Although we have identified several other radiation-induced molecules within tumor blood vessels, the beta(3) target for drug delivery achieves the greatest site-specific peptide binding within irradiated tumor blood vessels. We have focused on peptides and antibodies that bind to integrin beta(3). beta(3)-binding proteins have been conjugated to fluorochromes and radionuclides to study the site specificity and microscopic distribution. We have found immunofluorescent and immunohistochemical staining of beta(3) within the lumen of blood vessels immediately following irradiation. To determine whether it is feasible to guide drug delivery to irradiated tumors, we studied ligands to alpha(2b)beta(3) (fibrinogen). Peptides within fibrinogen that bind to alpha(2b)beta(3) includes the dodecapeptide, HHLGGAKQAGDV and the RGD peptide. We utilized 131I conjugation to these ligands to study the biodistribution in tumor bearing mice. Our clinical trial consists of the RGD peptidomimetic, biapcitide, labeled with 99mTc. This study shows that it is feasible to guide drugs to human neoplasms by use of radiation-guided peptides. These studies have shown that peptides that bind to these integrins bind to tumors following exposure to ionizing radiation.

Amino Acid Sequence↗

Radiation-mediated control of drug delivery.

Clinical trials of radiotherapy to control drug delivery were initiated in 1999 at Vanderbilt University. The initial studies exploited the findings that platelets are activated in tumor blood vessels after high-dose irradiation as used in radiosurgery and high-dose-rate brachytherapy. Platelets labeled with 111In showed binding in tumor blood vessels. However, the platelet labeling process caused platelets to also accumulate in the spleen. That clinical trial was closed, and subsequent clinical trials targeted protein activation in irradiated tumor blood vessels. Preclinical studies showed that peptide libraries that bind within irradiated tumor blood vessels contained the peptide sequence Arg-Gln-Asp (RGD). RGD binds to integrin receptors (e.g., receptors for fibrinogen, fibronectin, and vitronectin). We found that the fibrinogen receptor (GPIIb/IIIa, alpha2bbeta3) is activated within irradiated tumor blood vessels. RGD peptidemimetics currently in clinical trials include GPIIb/IIIa antagonists and the platelet-imaging agent biapcitide. Biapcitide is an RGD mimetic that is labeled with 99Tc to allow gamma camera imaging of the biodistribution of the GPIIb/IIIa receptor in neoplasms of patients treated with radiosurgery. This study has shown that the schedule of administration of the RGD mimetic is crucial. The peptide mimetic must be administered immediately before irradiation, whereas the natural ligands to the receptor compete for biapcitide binding if biapcitide is administered after irradiation. The authors currently are conducting a dose deescalation study to determine the threshold dosage required for RGD mimetic binding to radiation activated receptor. Radiation-guided clinical trials have been initiated by use of high-dose-rate brachytherapy. In a separate trial, the pharmacokinetics of radiation-inducible gene therapy are being investigated. In this trial, the radiation-activated promoter Egr-1 regulates expression of the tumor necrosis factor alpha gene, which is administered by use of the attenuated adenovirus vector. The Ad.Egr-TNF (ADGV) gene is administered by intratumoral injection of vector followed by irradiation in patients with soft-tissue sarcomas. This review highlights recent findings in these phase I pharmacokinetic studies of radiation-controlled drug delivery systems.

Animals↗

Multimodality nuclear medicine imaging in three-dimensional radiation treatment planning for lung cancer: challenges and prospects.

The purpose of this study was to determine the utility of quantitative single photon emission computed tomography (SPECT) lung perfusion scans and F-18 fluorodeoxyglucose positron emission computed tomography (PET) during X-ray computed tomography (CT)-based treatment planning for patients with lung cancer. Pre-radiotherapy SPECT (n = 104) and PET (n = 35) images were available to the clinician to assist in radiation field design for patients with bronchogenic cancer. The SPECT and PET scans were registered with anatomic information derived from CT. The information from SPECT and PET provides the treatment planner with functional data not seen with CT. SPECT yields three-dimensional (3D) lung perfusion maps. PET provides 3D metabolic images that assist in tumor localization. The impact of the nuclear medicine images on the treatment planning process was assessed by determining the frequency, type, and extent of changes to plans. Pre-radiotherapy SPECT scans were used to modify 11 (11%) treatment plans; primarily altering beam angles to avoid highly functioning tissue. Fifty (48%) SPECT datasets were judged to be 'potentially useful' due to the detection of hypoperfused regions of the lungs, but were not used during treatment planning. PET data influenced 34% (12 of 35) of the treatment plans examined, and resulted in enlarging portions of the beam aperture (margins) up to 15 mm. Challenges associated with image quality and registration arise when utilizing nuclear medicine data in the treatment planning process. Initial implementation of advanced SPECT image reconstruction techniques that are not typically used in the clinic suggests that the reconstruction method may influence dose response data derived from the SPECT images and improve image registration with CT. The use of nuclear medicine transmission computed tomography (TCT) for both SPECT and PET is presented as a possible tool to reconstruct more accurate emission images and to aid in the registration of emission data with the planning CT. Nuclear medicine imaging techniques appear to be a potentially valuable tool during radiotherapy treatment planning for patients with lung cancer. The utilization of accurate nuclear medicine image reconstruction techniques and TCT may improve the treatment planning process.

Humans↗

Quantitative pulmonary single photon emission computed tomography for radiotherapy applications.

Pulmonary imaging using single photon emission computed tomography (SPECT) is the focus of current radiotherapy research, including dose-response analysis and three-dimensional (3D) radiation treatment planning. Improvement in the quantitative capability of SPECT may help establish its potential role in this application as well as others requiring accurate knowledge of pulmonary blood flow. The purposes of this study were to quantitatively evaluate SPECT filtered backprojection (FBP) and ordered subset-expectation maximization (OS-EM) reconstruction implementations for measuring absolute activity concentration in lung phantom experiments, and to incorporate quantitative SPECT techniques in 3D-RTP for lung cancer. Quantitative FBP (nonuniform iterative Chang attenuation compensation, scatter correction, and 3D postreconstruction Metz filtering) and OS-EM implementations were compared with a "clinical" implementation of FBP (uniform multiplicative Chang attenuation compensation and post-reconstruction von Hann filtering), for their ability to improve quantification of inactive and active spherical defects in the lungs of an anthropomorphic torso phantom. Activity concentration estimates were found to depend on many factors, such as region of interest size, scatter subtraction constant (k), postreconstruction deconvolution filtering and, in the case of OS-EM, total number of iterations. In general, reconstruction implementations incorporating compensation for nonuniform attenuation and scatter provided reduced bias relative to the clinical implementation. Potential applications to lung radiotherapy, including dose-functional histograms and treatment planning are also discussed. SPECT has the potential to provide accurate estimates of lung activity distributions that, together with improved image quality, may be useful for the study and prediction of therapeutic response.

Algorithms↗

Physical and biological predictors of changes in whole-lung function following thoracic irradiation.

PURPOSE: To develop methods of predicting the pulmonary consequences of thoracic irradiation (RT) by prospectively studying changes in pulmonary function following RT. METHODS AND MATERIALS: 100 patients receiving incidental partial-lung irradiation during treatment of tumors in or adjacent to the thorax had whole-lung function assessed via symptoms and pulmonary function tests (PFTs: FEV1-forced expiratory volume 1 s; DLCO-diffusion capacity) before and repeatedly 6-48 months following RT. All had computed tomography-based three-dimensional (3D) dose calculations with lung density heterogeneity corrections for dose-volume histogram (DVH) and normal tissue complication probability (NTCP) calculations. Functional DVHs (DVfH) based on SPECT (single photon emission computed tomography) lung perfusion scans, and serial transforming growth factor-beta (TGF-beta1) levels were available in 50 and 48 patients, respectively. The incidence and severity of changes in whole-lung function were correlated with clinical, physical, and biological factors. Exploratory statistical analyses were performed using chi-square, Pearson correlations, logistic regression, and multiple linear regression. RESULTS: RT-induced symptoms developed in 21 patients. In the overall group, the single best predictor for the development of symptoms was the NTCP (p < 0.05). Pre-RT PFTs alone were less predictive (p = 0.1 for FEV1, p = 0.08 for DLCO). A multivariate model based on pre-RT DLCO and CT-based NTCP was strongly predictive for the development of symptoms (p < 0.001). NTCPs based on SPECT-derived DVf Hs and TGF-beta1 levels did not appear to provide additional predictive value. The presence or absence of pulmonary symptoms was correlated with the decline in PFT 6 months following RT (p < 0.05). In the overall group, the degree of decline in PFTs was not well correlated with any of the dose-volume variables considered. In patients with "good" pre-RT PFTs, there was a relationship between the percent reduction in PFT and dose-volume parameters such as the percent of lung volume receiving > 30 Gy (p < 0.05). CONCLUSION: The extent of alteration in whole-lung function (symptoms or PFT changes) appears to be related to both dose-volume and pre-RT PFT parameters. The data suggest that no one variable is likely to be an adequate predictor and that multivariate predictive models will be needed. Additional studies are underway to develop better predictive models that consider physical factors such as the DVH and regional perfusion, as well as biological/clinical factors such as pre-RT PFTs and TGF-beta1.

Adult↗

Breast tumour imaging using incomplete circular orbit pinhole SPET: a phantom study.

Improvements in 99Tcm-sestamibi breast lesion visualization using single photon emission tomography (SPET) may help define the clinical role of this technique alongside X-ray mammography in the diagnosis and management of breast cancer. Pinhole SPET offers the advantages of high resolution and sensitivity when compared to conventional parallel-beam collimation for sources located near the pinhole aperture. In this work, the potential of incomplete (180 degrees) circular orbit (ICO) SPET with pinhole collimation is investigated as a means to visualize small (6.4 and 9.6 mm diameter) spherical simulated tumours, at clinical count densities and tumour-to-background ratios, in a breast phantom. ICO pinhole SPET is compared to complete circular orbit (CCO) pinhole SPET for reference, and planar breast imaging (scintimammography) using parallel-beam and pinhole collimators. A prototype box-shaped pinhole collimator with a 4 mm diameter circular aperture was used to acquire projections of an 890 ml breast phantom both in isolation and mounted on a cylinder filled with a mixture of 99Tcm-pertechnetate and water. A heart phantom containing 99Tcm activity in the myocardium was placed in the cylinder. Simulated tumours containing 99Tcm were placed in the breast phantom and scanned at clinically relevant count densities and scan times with tumour-to-normal tissue concentration ratios of 5.0:1 (9.6 mm sphere) and 7.7:1 (6.4 mm sphere). Phantom data were reconstructed using pinhole filtered backprojection (FBP) and maximum likelihood-expectation maximization (ML-EM). The tumours were not visualized with scintimammography, in which lesion contrast and signal-to-noise were estimated from region of interest analysis to be < 2% and 0.01, respectively. Average (over lesion size and scan time) contrast and signal-to-noise in the ICO (CCO) SPET images were 33% and 1.72 (34% and 1.3), respectively. These values indicate that ICO pinhole SPET has the potential to improve visualization of small (< 10 mm) breast tumours when compared with scintimammography, which may be beneficial for the early classification of cancers of the breast.

Breast Neoplasms↗

Half-cone beam collimation for triple-camera SPECT systems.

UNLABELLED: Cone-beam collimators provide increased sensitivity at similar resolution compared to other collimators. The use of cone-beam collimators for brain imaging with triple-camera SPECT systems, however, results in truncation of the base of the brain because of clearance of the shoulders. A half-cone beam collimator does not have the problem of truncation. The objective of this study was to compare the performance characteristics of half-cone beam with parallel-beam and fan-beam collimators with similar resolution characteristics for SPECT imaging of the brain. METHODS: A half-cone beam collimator with the focal point located towards the base of the brain was built for a triple-camera SPECT system. Spatial resolutions and sensitivities of three collimators were measured. RESULTS: When 10-cm from the collimator surface, the planar spatial resolutions FWHM in mm (point source sensitivities in cps-MBq) for half-cone beam, fan-beam and parallel-beam collimators were 5.2 (85.6), 5.1 (55.6) and 5.9 (39.7), respectively. Image quality was evaluated using a three-dimensional Hoffman brain phantom and patient data. The deeper gray matter were more clearly visualized in the half-cone beam scans. CONCLUSION: Half-cone beam collimation provides higher sensitivity and offers the potential for improved brain imaging compared with parallel-beam and fan-beam collimation when used with a triple-camera SPECT system.

Brain↗