PubMed Health⌕ Search

Biomedical subjects

C Schlosser

Publications and source records attributed to C Schlosser.

9 recordsLinked to original sources

A new compilation of the atmospheric 85krypton inventories from 1945 to 2000 and its evaluation in a global transport model.

This paper gives the yearly (85)Kr emissions of all known reprocessing facilities, which are the main sources of (85)Kr in the atmosphere since 1945, for the years 1945 until 2000. According to this inventory 10,600 PBq (Peta=10(15)) of (85)Kr have been globally emitted from the year 1945 until the end of 2000. The global atmospheric inventory at the end of the year 2000 amounts to 4800 PBq. These emissions have been incorporated into the ECHAM4 atmospheric general circulation model as point sources. Monthly mean model results are compared with measurements made at different locations and times. The influence of each source on the measured concentrations at various locations is studied. The calculated concentrations are found to give reasonably good agreement with the observations, indicating that the emission inventory is realistic. Although, at all northern hemispheric observation sites the model tends to slightly overestimate the concentrations. A possible reason for this overestimation can be found in model features (coarse resolution in time and space). The most prominent discrepancy that is consistently repeated at all northern hemispheric stations occurs in the early 1990s. This could most likely be related to an overestimate of sources. Possibly, the Russian emissions declined earlier than assumed in the current database. Another discrepancy between observations and simulations indicating an incompleteness of the release data is found at some southern hemispheric sites. The variability of their observations could only be explained by regional sources. However, several spikes occur after 1992 when no reprocessing facility is known to be in operation in the southern hemisphere. Production of isotopes for radiopharmaceuticals like technetium-99m from highly enriched uranium is the most likely explanation.

Air Movements↗

Monitoring ground-level air for trace analysis: methods and results.

Trace analysis enables the sensitive detection of radionuclide concentrations in ground-level air in the range of microbecquerel per cubic meter (microBq m(-3)). Typical sampling intervals of less than one day up to a few days can be used in routine operation. Trace analysis measurements are performed in the framework of the German Integrated Measuring and Information system (IMIS) and the International Monitoring System (IMS) used for verification of the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Within the environmental monitoring programmes of the German IMIS the Federal Office for Radiation Protection (BfS) performs measurements of aerosol-bound radionuclides and of radioactive noble gases in the atmosphere. Aerosols are collected on filters with high-volume air samplers and analysed by gamma-spectrometry, alpha-spectrometry, and integral measurements of beta-activity, with preceding radiochemical separation. Noble gas samples from 15 sites world-wide are analysed to observe the (85)Kr-release from nuclear fuel reprocessing plants and from seven sites in Germany to monitor the (133)Xe emitted from nuclear power plants. As part of the International Monitoring System (IMS) of the CTBT an automatic aerosol sampling and measuring system and an automatic noble gas sampling and measuring system will be operated by the BfS at Mount Schauinsland near Freiburg. Because of its expertise in noble gas measurements the BfS had been chosen to perform an intercomparison experiment in the BfS laboratory in Freiburg with several automatic noble gas sampling and measurement systems before their installation at IMS sites. To establish quality-assurance programmes for trace analysis performed for the German IMIS close collaboration between the involved German institutions has been established. First steps have been taken to expand cooperation to other European laboratories. Informal data exchange already occurs between trace-analysis laboratories in Europe (Ring of Five) and helps in cases of enhanced activity concentrations to get a rapid overview of the radiological situation and to identify possible sources.

Journal Article↗

Intercomparison experiments of systems for the measurement of xenon radionuclides in the atmosphere.

Radioactive xenon monitoring is one of the main technologies used for the detection of underground nuclear explosions. Precise and reliable measurements of (131m)Xe, (133g)Xe, (133m)Xe, and (135g)Xe are required as part of the International Monitoring System for compliance with the Comprehensive Nuclear-Test-Ban Treaty (CTBT). For the first time, simultaneous testing of four highly sensitive and automated fieldable radioxenon measurement systems has been performed and compared to established laboratory techniques. In addition to an intercomparison of radioxenon monitoring equipment of different design, this paper also presents a set of more than 2000 measurements of activity concentrations of radioactive xenon made in the city of Freiburg, Germany in 2000. The intercomparison experiment showed, that the results from the newly developed systems agree with each other and the equipment fulfills the fundamental requirements for their use in the verification regime of the CTBT. For 24-h measurements, concentrations as low as 0.1 mBqm(-3) were measured for atmospheric samples ranging in size from 10 to 80 m(3). The (133)Xe activity concentrations detected in the ambient air ranged from below 1 mBqm(-3) to above 100 mBqm(-3).

Air Pollutants, Radioactive↗

Detection and analysis of xenon isotopes for the comprehensive nuclear-test-ban treaty international monitoring system.

The use of the xenon isotopes for detection of nuclear explosions is of great interest for monitoring compliance with the comprehensive nuclear-test-ban treaty (CTBT). Recently, the automated radioxenon sampler-analyzer (ARSA) was tested at the Institute for Atmospheric Radioactivity (IAR) in Freiburg, Germany to ascertain its use for the CTBT by comparing its results to laboratory-based analyses, determining its detection sensitivity and analyzing its results in light of historical xenon isotope levels and known reactor operations in the area. Xe-133 was detected nearly every day throughout the test at activity concentrations ranging between approximately 0.1 mBq/m3 to as high as 120 mBq/m3. Xe-133m and 135Xe were also detected occasionally during the test at concentrations of less than 1 to a few mBq/m3.

Environmental Monitoring↗

Content of non-mercury-associated selenium in human tissues.

Recent studies have shown that at a higher mercury (Hg) burden, the molar ratio of selenium (Se) and Hg in tissues tends to approximate 1:1 by the formation of biologically largely inert adducts. From the toxicological standpoint, this trapping of free Hg is welcome. However, this binding of Se to Hg reduces the portion of Se in tissues, which is available for the formation of essential selenoenzymes like glutathione peroxidase, type I deiodase, and so forth and could result in a relative deficiency of Se. Therefore, we tried to determine the concentration of non-Hg-associated Se in several human tissues. As there is no proved trace method for the speciation of non-Hg-bound and Hg-bound Se in tissues, the total concentrations of Hg and Se were determined and the portion of non-Hg-associated Se was calculated by the difference of the molar concentrations of Se and Hg. For this investigation, the following tissues were obtained by autopsy from 133 adults: kidney cortex, thyroid gland, liver, spleen, cerebrum cortex, and pituitary gland. In no case was an occupational Hg burden known. The results confirm the assumption of a 1:1 association of Hg and Se in human tissues. The mean concentration of non-Hg-bound Se was calculated to 576 microg/kg in the kidney cortex, 363 microg/kg in the thyroid gland, 308 microg/kg in the liver, 205 microg/kg in the spleen, 111 microg/kg in the cerebrum cortex, and 545 microg/kg in the pituitary gland. In none of the cases under investigation in any tissue was the molar Se/Hg ratio below 1. This means that a total deficiency of non-Hg-bound Se could not be seen in this normal population, even at a higher Hg burden. Nevertheless, at a suboptimal Se supply like in Germany, any reduction of the part of Se, which is available for the formation of essential seleno-enzymes, should be avoided. Therefore, any additional Hg burden such as from dental amalgam should to be considered critically. The different distribution of Hg and Se in the body confirms that there is a controlled hierarchy in the Se supply of different organs, which tries to prevent a Se deficiency in organs with essential seleno-enzymes like the thyroid gland even under an suboptimal Se supply.

Adolescent↗

Evidence for effects of insulin on sensory processing in humans.

Systemic insulin passes the blood-brain barrier and insulin receptors have been detected in various brain regions. Yet, the biological significance of insulin acting on the brain remains rather unclear. Reports of different awareness of hypoglycemic symptoms during hypoglycemia induced by human insulin (HI) and porcine insulin (PI) suggest a modulatory influence of insulin on sensory processing. In a double-blind, within-subject, crossover comparison, we recorded visual-evoked potentials (VEP) in 30 healthy men during euglycemia and after 20 or 50 min of constant hypoglycemia of 2.66 mM (47.9 mg/dl) induced by HI and PI. Blood glucose and serum insulin levels were identical in both sessions. Hypoglycemia reduced amplitudes of the VEP components P1 and N2 and increased latencies of N1, P1, and N2. However, hypoglycemia-induced changes in VEP amplitudes and latencies were significantly stronger during PI and HI infusion: P1-N2 difference amplitude decreased from (mean +/- SE) 11.9 +/- 0.9 to 10.7 +/- 0.8 muV during HI and from 12.4 +/- 0.9 to 8.7 +/- 0.7 muV during PI infusion (P < 0.002). P1 latency increased from 112.0 +/- 3.2 to 118.8 +/- 3.2 ms during HI and from 114.0 +/- 3.3 to 126.3 +/- 4.6 ms during PI infusion (P < 0.05). Differences between the effects of the insulins were consistently apparent after 20 min of hypoglycemia, which indicates a short-term action of the hormone. The results add to those of a foregoing study demonstrating differential effects of HI- and PI-induced hypoglycemia on auditory evoked potentials.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

The oxygen dependence of mitochondrial oxidative phosphorylation and its role in regulation of coronary blood flow.

The oxygen dependence of mitochondrial oxidative phosphorylation measured in isolated cells of cardiac and non-cardiac origin are affected by the metabolic state of the cells. The contribution of oxygen diffusion to the measured P50 value in resting cells is small. In cardiac myocytes, and possibly in the other cells as well, this contribution may become significant near maximal levels of respiration. The influence of cellular energy metabolism on the oxygen dependence of respiration in cardiac myocytes suggests strongly that mitochondrial oxidative phosphorylation in these cells is an oxygen sensor for adjusting coronary vascular tone during normal cardiac function.

Adenosine Triphosphate↗

Cellular energetics and the oxygen dependence of respiration in cardiac myocytes isolated from adult rat.

The oxygen dependence of mitochondrial respiration was investigated using suspensions of mitochondria and quiescent ventricular myocytes isolated from adult rat hearts. A new optical method was used to determine oxygen concentration in the suspending media. The P50 for respiration for coupled mitochondria at a high [ATP]/[ADP].[Pi] ratio and oxidizing glutamate/malate was 0.45 +/- 0.03 microM but was increased to 0.57 +/- 0.02 microM by the addition of succinate to the substrate mixture. This value was decreased to less than 0.06 +/- 0.01 microM when the ATP/ADP.Pi ratio was decreased with the uncoupler, carbonyl cyanide p-trifluoromethoxyphenylhydrazone. The P50 value in resting myocytes was 2.23 +/- 0.13 microM at a Vmax of 13.22 +/- 1.38 nmol of O2/g, dry weight/min. During resting conditions, the creatine phosphate/creatine and ATPfree/ADPfree ratios were high in these cells, 6.81 +/- 1.11 and 1131 +/- 185, respectively. Addition of 1 mM Ca2+ to the suspending media increased the P50 by 50% whereas respiration rose by only 10%. Respiratory rate was increased up to about 10-fold by uncoupling the cells, but the P50 increased by less than 3-fold. When these uncoupled cells were inhibited with Amytal to lower the rate of oxygen consumption to that of resting cells, the P50 fell to 1.25 +/- 0.14 microM. Diffusion models indicate that in resting myocytes, the oxygen concentration difference from sarcolemma to cell core was approximately 1.84 microM with an additional difference of about 0.27 microM attributed to the unstirred layer of media surrounding each cell. The intracellular oxygen diffusivity coefficient in myocytes was calculated to be 0.30 x 10(-5) cm2/s. The results show that the oxygen dependence of respiration is modulated by the cellular metabolic state. At near maximal levels of respiration or on recovery from hypoxic episodes, oxygen diffusion may become an important determinant of the oxygen dependence of myocardial respiration.

Animals↗

Increased cortisol production in women runners.

Because we previously found increased basal serum cortisol levels in women runners, we examined adrenocortical function in amenorrheic running women (AR), eumenorrheic running women (R), and normal nonexercising women (NC) in further detail. Mean 24-h urinary cortisol levels were significantly elevated (P less than 0.001) in six AR [45.1 +/- 7.2 (+/- SEM) micrograms/24 h] and eight R (38.5 +/- 6.9 micrograms/24 h) compared to four NC (13.9 +/- 2.8 micrograms/24 h). After adrenal suppression with 2 mg dexamethasone, integrated responses and absolute maximal elevations in serum cortisol levels in response to 10 micrograms/m2 exogenous ACTH (1-24) administered as an iv bolus dose, were not significantly different among six AR, six R, and six NC. This dose of ACTH results in maximal steroid release. The disappearance rates of cortisol (5 mg, iv) after dexamethasone suppression were similar in four AR, five R, and four NC and corresponded to a two-compartment model with mean half-lives of 4.9 and 93.8 min, respectively. Cortisol-binding globulin levels were also similar among the groups. These data document higher cortisol secretion and suggest increased ACTH secretion in running women.

Adolescent↗