PubMed Health⌕ Search

Biomedical subjects

C Schulze-Briese

Publications and source records attributed to C Schulze-Briese.

5 recordsLinked to original sources

The PILATUS 1M detector.

The PILATUS 1M detector is a hybrid pixel array detector with over one million pixels that operate in single photon counting mode. The detector, designed for macromolecular crystallography, is the largest pixel array detector currently in use at a synchrotron. It is a modular system consisting of 18 multichip modules covering an area of 21 cm x 24 cm. The design of the components as well as the manufacturing of the detector including the bump-bonding was performed at the Paul Scherrer Institute (PSI). The use of a single photon counting detector for protein crystallography requires detailed studies of the charge collection properties of the silicon sensor. The 18 modules are read out in parallel, leading to a full frame readout-time of 6.7 ms. This allows crystallographic data to be acquired in fine-varphi-slicing mode with continuous rotation of the sample. The detector was tested in several experiments at the protein crystallography beamline X06SA at the Swiss Light Source at PSI. Data were collected both in conventional oscillation mode using the shutter, as well as in a fine-varphi-slicing mode. After applying all the necessary corrections to data from a thaumatin crystal, the processing of the conventional data led to satisfactory merging R-factors of the order of 8.5%. This allows, for the first time, determination of a refined electron density map of a macromolecular biological crystal using a silicon pixel detector.

Crystallography, X-Ray↗

Shearing interferometer for quantifying the coherence of hard x-ray beams.

We report a quantitative measurement of the full transverse coherence function of the 14.4 keV x-ray radiation produced by an undulator at the Swiss Light Source. An x-ray grating interferometer consisting of a beam splitter phase grating and an analyzer amplitude grating has been used to measure the degree of coherence as a function of the beam separation out to 30 microm. Importantly, the technique provides a model-free and spatially resolved measurement of the complex coherence function and is not restricted to high resolution detectors and small fields of view. The spatial characterization of the wave front has important applications in discovering localized defects in beam line optics.

Journal Article↗

Beam-size effects in radiation damage in insulin and thaumatin crystals.

Cryocooled insulin and thaumatin crystals were irradiated in a series of alternating data collections and high-dose-rate exposures using either a vertically focused or vertically defocused beam. The main result is that the radiation damage is limited to the exposed region, which can be explained by the short range of the photoelectrons and the Auger electron cascade produced by light elements. Consequently, the unexposed angular range provides significantly improved data quality and electron density compared with previously exposed angular wedges of the crystal when a vertically focused beam is used, while no differences are observed between a fresh wedge and an exposed region for the vertically defocused beam. On the other hand, the focused beam provides higher I/sigma(I) ratios at high resolution than homogeneous sample illumination but also causes more rapid sample deterioration.

Crystallization↗

Fixed-exit monochromator for computed tomography with synchrotron radiation at energies 18-90 keV.

A fixed-exit monochromator has been constructed for computed tomography (CT) studies at the Medical Beamline of the European Synchrotron Radiation Facility. A non-dispersive pair of bent Laue-type crystals is used, and the first crystal is water-cooled. The monochromator operates at energies from 18 to 90 keV, and the maximum width of the beam is 150 mm. The performance of the monochromator is studied with respect to the beam intensity and energy distributions, and a close agreement is found between the calculated and experimental results. The intensity is between 10(9) and 10(10) photons s(-1) mm(-2) under typical operating conditions. The harmonic content of a 25 keV beam is about 30% at the minimum wiggler gap of 25 mm (field 1.57 T) and decreases by an order of magnitude when the gap is increased to 60 mm (field 0.62 T). The experimental set-up for CT studies includes dose monitors, goniometers and translation stages for positioning and scanning the object, and a 432-element linear-array Ge detector. Examples from phantom studies and in vivo animal experiments are shown to illustrate the spatial resolution and contrast of the reconstructed images.

Journal Article↗

Synchrotron beam test with a photon-counting pixel detector.

Synchrotron beam measurements were performed with a single-photon-counting pixel detector to investigate the influence of threshold settings on charge sharing. Improvement of image homogeneity by adjusting the threshold of each pixel individually was demonstrated. With a flat-field correction, the homogeneity could be improved. A measurement of the point spread function is reported.

Journal Article↗