PubMed Health⌕ Search

Biomedical subjects

C Schunn

Publications and source records attributed to C Schunn.

7 recordsLinked to original sources

STEP--a System for Teaching Experimental Psychology using E-Prime.

Students in psychology need to learn to design and analyze their own experiments. However, software that allows students to build experiments on their own has been limited in a variety of ways. The shipping of the first full release of the E-Prime system later this year will open up a new opportunity for addressing this problem. Because E-Prime promises to become the standard for building experiments in psychology, it is now possible to construct a Web-based resource that uses E-Prime as the delivery engine for a wide variety of instructional materials. This new system, funded by the National Science Foundation, is called STEP (System for the Teaching of Experimental Psychology). The goal of the STEP Project is to provide instructional materials that will facilitate the use of E-Prime in various learning contexts. We are now compiling a large set of classic experiments implemented in E-Prime and available over the Internet from http://step.psy.cmu.edu. The Web site also distributes instructional materials for building courses in experimental psychology based on E-Prime.

Humans↗

[Conventional aortic surgery after endovascular aortic reconstruction].

INTRODUCTION: Endovascular therapy of aortic aneurysms is an attractive alternative to conventional aortic surgery. A number of patients, however, will fail endovascular therapy and require open surgical repair. METHODS: We report our experience with conversion to open aortic repair. Of 306 patients given endovascular therapy for an infrarenal aortic aneurysm, 30 (9.8%) required conversion to conventional repair. RESULTS: Thirteen patients (43.3%) suffered complications, 3 (10%) of which were fatal. Conversion to open aortic repair after endovascular therapy is technically more demanding than primary open repair, particularly because of clamp techniques and stent-extraction. CONCLUSIONS: Emergent conversion operations, especially when preceded by significant retroperitoneal bleeding from vascular tears due to endovascular manipulations are complicated by significant morbidity and mortality.

Adult↗

[Eversion endarterectomy--out?].

Carotid eversion endarterectomy has become a well established alternative to conventional carotid endarterectomy. Similar perioperative morbidity and mortality results have been documented in several large clinical series. Our experience with carotid reconstructive surgery consists of 12,596 operations between 8/84 and 12/97, some 60% of which were performed using the eversion technique. Transient or permanent neurologic deficit was observed in 2.0%; 0.8% died after the procedure. Eversion endarterectomy should only be performed under suitable anatomic conditions. It is a challenging technique which requires advanced surgical skills and sound clinical judgement. The long-term rate of restenosis seems to be influenced favourably after eversion endarterectomy.

Blood Vessel Prosthesis Implantation↗

[Treatment of restenosis].

Carotid restenosis after endarterectomy is observed in up to 24.1% of patients with long-term follow up. Indication for reintervention in asymptomatic patients however should be reserved for greater than 80% stenosis. Treatment options include repeat surgical reconstruction as well as intraoperative or percutaneous balloon angioplasty +/- stenting. We compared our past experience with 66 operative reconstructions in 64 patients with a recent series of 60 patients who underwent intraoperative balloon-dilatation and stenting. After conventional surgery 2 patients (3.1%) suffered a permanent neurological deficit, one patient developed a TIA (1.5%). After intraoperative dilation and stenting 8 patients (13.3%) suffered a stroke; 2 patients died after surgery (one stroke, one myocardial infarction) (mortality 3.3%). When compared to conventional operative repair intraoperative carotid balloon angioplasty and stenting of restenosis is complicated by a substantial increase in morbidity and mortality and cannot be recommended as routine therapy.

Angiography, Digital Subtraction↗

[Imaging of aortic endoprostheses and their complications].

PURPOSE: To determine the optimal postoperative imaging modality for the follow-up of patients with endoluminal aortic stent grafts. MATERIAL AND METHODS: From August 1994 to November 1997, 214 patients (194 male and 20 female) with abdominal and thoracic aortic aneurysms were treated with endovascular stent grafts. 137 patients (129 male, 8 female) with 89 tube grafts and 48 bifurcated grafts (45 EVT, 88 Stentor/Vanguard, 3 Chuter, 1 Talent) were evaluated with contrast-enhanced spiral-CT, duplex ultrasound, and DSA at a mean follow-up of 11.1 months. RESULTS: We found 12 persistent primary endoleaks (8.8%), 17 secondary endoleaks (12.4%), 8 limb occlusions (5.8%), 28 endoluminal thrombi lining the stent graft (20.4%), and 26 suture breakages of the stent frame (19%). In 9 patients (6.6%) the proximal end of the stent partially covered the renal arteries. In 3 patients (2.2%) a partial renal infarction was seen. Spiral-CT was able to demonstrate all the above changes except for 3 sidebranch endoleaks that were documented by duplex ultrasound only and 8 suture breaks seen on abdominal plain films only. The median aneurysm diameter decreased from 48 mm pre-operatively to 46 mm at 24 months post-operatively in patients with endoleaks and from 44 mm to 36 mm in patients without endoleak. For several patients the decreasing aneurysm diameter did not reliably correlate with complete exclusion of the aneurysm. CONCLUSION: For follow-up of endoluminal aortic stent grafts contrast-enhanced spiral-CT is superior to duplex ultrasound. DSA is necessary only for patients with complications requiring a secondary intervention.

Adult↗

Postoperative color flow duplex scanning in aortic endografting.

PURPOSE: To report the feasibility and sensitivity of duplex sonography compared to computed tomography (CT) for aortic endograft follow-up surveillance. METHODS: In a 26-month period, 113 aortic aneurysm patients received 79 tube and 34 bifurcated stent-grafts. Follow-up used contrast-enhanced CT scanning and duplex sonography with an intravenous ultrasound contrast agent (Levovist). RESULTS: Eleven patients (9.7%) were converted to open repair; 1 died from hemorrhagic shock secondary to retroperitoneal hematoma. The mean follow-up time was 7.2 months (range 1 to 24), during which 5 patients died of unrelated causes. Sixteen primary (within 30 days) and 5 secondary endoleaks were detected by duplex after tube graft implantation. Among 5 endoleaks due to retrograde side-branch perfusion, 3 were detected only with contrast-enhanced duplex scanning. Iliac artery occlusion was also documented using duplex; however, 2 stent fractures could not be seen with ultrasound. Ten primary endoleaks were detected in bifurcated stent-graft patients. One endoleak originating from the distal iliac limb anchoring site was missed by duplex owing to bowel gas. Graft limb thrombosis was clearly identified by lack of a flow signal on duplex. CONCLUSIONS: Duplex sonography could be a valuable, reliable, and economical surveillance tool for endovascular aortic reconstructions. The adjunctive use of an intravenous ultrasound contrast agent increased the sensitivity for detecting endoleak to a level comparable to contrast-enhanced CT scanning. However, stent fractures may not be seen on ultrasound, and bowel gas can interfere with obtaining an adequate image.

Adult↗

[Results and complications after endovascular reconstruction of aortic aneurysms].

Between August 1994 and December 1996 137 patients (10 female and 127 male, mean age 66 yrs., range 27-85) with aortoiliac aneurysmal disease were treated with endovascular stent grafts. Pathology included 5 thoracic, 131 abdominal and 1 isolated iliac artery aneurysm. 88 straight tube grafts (75 Mintec, 12 EVT, 1 Chuter) and 43 bifurcated grafts (21 Mintec, 20 EVT, 2 Chuter) were implanted in the infrarenal aorta. 5 (Mintec) tube grafts were used for the thoracic aneurysms. One tapered tube graft was used to exclude the isolated iliac aneurysm. 11 patients (8%) required conversion to open surgical repair. This was due to defective devices in 5, device related occlusion of a renal artery in 2, aortic dissection in 1, occlusion of iliac outflow in 1, a large unmanageable proximal endoleak in 1 and a retroperitoneal bleeding resulting in hemorrhagic shock in 1 patient. There was one procedure related death for a mortality of 0.7%. Patients were followed every 3-6 months using CT with i.v. contrast and ultrasound duplex examinations with adjunctive usage of an intravenous ultrasound contrast agent (Levovist, Schering AG). Intraarterial DSA was used only when called for by thrombotic or stenotic complications. At a mean follow-up of 9.2 months (range 2-24 months) 16 (17%) primary and 8 (8.5%) secondary leaks (at the distal anchoring zone) were detected after implantation of tube grafts. 11 (25.6%) leaks were detected after implantation of bifurcated grafts. Iliac artery occlusion was observed in 2 patients after placement of a straight endograft, 6 times after reconstruction with a Mintec bifurcated device and 3 times after implantation of an EVT bifurcated endograft. Successful treatment of iliac artery occlusion without the need for subsequent amputation or major disability included extraanatomic bypass in 7 patients, PTA (3 patients) and implantation of wallstents (2 patients) or conservative management (1 patient).

Adult↗