PubMed Health⌕ Search

Biomedical subjects

C Seemann

Publications and source records attributed to C Seemann.

8 recordsLinked to original sources

Association of concentration of asbestos and asbestos-like fibers with the patient's survival and the binding capacity of lung parenchyma to galectin-1 and natural alpha-galactoside- and alpha-mannoside-binding immunoglobulin G subfractions from human serum.

Our aim in this study was to search for lung parenchyma alterations associated with asbestos and/or asbestos-like fiber concentration. This was done by means of immuno- or glycohistochemistry. The hot-ashing technique determined the asbestos and asbestos-like fiber concentrations in the lung tissues of 100 patients of whom 52 were treated for primary lung and 25 for secondary lung tumors; fiber concentration was also measured for 23 patients whose disease was benign. The results were correlated to smoking habits, survival of the patients, and expression of binding capacities for endogenous lectins, natural carbohydrate-binding and lectin-specific antibodies. The cohort with proven asbestos exposure revealed a mean fiber concentration 114 f/g compared to 95 f/g in the non-exposed group. An increased asbestos fiber concentration was correlated to galectin-1-binding and the presence of epitopes for natural immunoglobulin G subfractions with selectivity to alpha-galactosides and alpha-mannosides. The survival of patients with primary and secondary lung tumors was negatively associated with the fiber concentration. The data indicate that increased presence of asbestos is correlated with an alteration of defined glycohistochemical features of alveolar lining cells.

Adult↗

Fine-needle aspiration biopsy of the thyroid gland: results of a five-year experience and discussion of its clinical limitations.

The results of a five-year experience with fine-needle thyroid aspiration cytology are reported to assess the value, accuracy and limitations of this biopsy procedure. The cytologic diagnoses on 1,465 thyroid aspirates are listed, and correlation of cytology with histology on 207 cases undergoing surgery is reported. The incidence of malignancy among the atypical and malignant cytology aspirates with histologic confirmed diagnosis was 65% (28/43) while a false negative rate of 11.5% (15/131) was found. Fine-needle aspiration biopsy is a safe and useful procedure with an acceptable accuracy rate that complements other investigations in the screening of patients for thyroid surgery.

Adenocarcinoma↗

[Sideeffects of colloids (author's transl)].

A prospective controlled trial during 1975 and 1976 has revealed that none of the colloids in clinical use (plasma protein solution, gelatine, hydroxyethylstarch and dextran) is free from the risk of anaphylactoid reactions. Even though the incidence of anaphylactoid reactions is low (0.03%), lethal outcome might be encountered. Between the colloids differences exist as far as manifestation (skin, circulatory and respiratory system) and degree of severity (I--IV) of anaphylactoid reactions are concerned. Since the underlying pathomechanisms have not been elucidated yet, true prophylactic measures are unknown. Therefore, it is mandatory to control the patient very carefully at the beginning of infusion; early symptoms of anaphylactoid reactions should trigger immediate therapeutic measures. Recent findings showed that the anaphylactoid reactions to dextran might be elicited by immune complexes. A new model was developed to investigate the chances of specific prophylactic procedures.

Anaphylaxis↗