PubMed HealthSearch

Biomedical subjects

C Senn

Publications and source records attributed to C Senn.

5 recordsLinked to original sources

Novel recombinant fusion protein analogues of insulin-like growth factor (IGF)-I indicate the relative importance of IGF-binding protein and receptor binding for enhanced biological potency.

An efficient expression system in Escherichia coli for several biologically active insulin-like growth factor-I (IGF-I) fusion peptide analogues is described. These novel IGF-I fusion protein analogues have properties that make them very useful reagents in the investigation of IGF-I action. The analogues comprise an IGF-I sequence and the first 11 amino acids of methionyl porcine growth hormone (pGH) and include [Met1]-pGH(1-11)-Val-Asn-IGF-I, which contains the authentic IGF-I sequence, and two analogues, [Met1]-pGH(1-11)-Val-Asn-[Gly3]-IGF-I and [Met1]-pGH(1-11)-Val-Asn-[Arg3]-IGF-I, where Glu-3 in the human IGF-I sequence has been replaced by Gly or Arg respectively. The three peptides are referred to as Long IGF-I, Long [Gly3]-IGF-I or Long [Arg3]-IGF-I depending on the IGF-I sequence present. Production of the purified fusion peptides was aided by folding the reduced and denatured fusion peptide sequence under conditions that gave very high yields of biologically active product. Introduction of a hydrophobic N-terminal extension peptide appears to facilitate the correct folding of the IGF-I analogues compared with that obtained previously when folding normal-length IGFs. The biological activities of the IGF-I fusion peptides were compared with authentic IGF-I and the truncated analogue, des(1-3)IGF-I. In L6 rat myoblasts, all the analogues were more potent than authentic IGF-I in their abilities to stimulate protein and DNA synthesis and inhibit protein breakdown. In H35 hepatoma cells, where the IGFs act through the insulin receptor, the Long IGF-I analogues maintained a similar potency relative to IGF-I as was observed in the L6 myoblasts. The order of biological potency in cell lines secreting IGF-binding proteins (IGFBPs) into the medium was Long [Arg3]-IGF-I-des(1-3)IGF-I greater than Long [Gly3]-IGF-I greater than Long IGF-I greater than IGF-I. In chicken embryo fibroblasts, a cell line that does not secrete detectable IGFBPs into the medium, Long [Arg3]-IGF-I, was less potent than IGF-I. Investigation of receptor and IGFBP association by these analogues reinforced our previous findings that N-terminal analogues of IGF-I show increased biological potency due to changes in the degree of their IGFBP interactions.

Amino Acid Sequence

Bleeding on probing as it relates to probing pressure and gingival health.

The present study was designed to determine the threshold pressure value to be applied in provoking bleeding on probing (BOP) in clinically healthy gingival units. 12 female dental hygiene students volunteered for the study. They were selected on the basis of excellent oral hygiene standards, absence of probing depths greater than 3 mm and absence of caries or dental restorations on smooth and proximal tooth surfaces. Applying a probing force of 0.25, 0.5, 0.75 and 1.0 N in one of the 4 jaw quadrants, respectively, on 2 different occasions with an interval of 10 days, bleeding on probing was assessed. Oral hygiene and gingival conditions were determined using the criteria of the plaque control record and the gingival index. On the basis of the BOP values, obtained using the lowest probing force (0.25 N), the subjects were divided into 2 groups: group 1 ("minimal BOP" value) consisted of 6 subjects yielding practically no bleeding (mean BOP = 0.9%) at both examinations, while the subjects of group 2 ("low BOP" value) had slightly higher BOP% (mean BOP = 13.4%). Both groups showed significant increase in mean BOP% with increasing probing force (0.9%-36.1% in group 1 and 13.4%-47.0% in group 2). Regression analysis revealed an almost linear correlation and a high correlation coefficient between BOP% and probing force. The comparison of the regression lines of the 2 groups showed almost identical slope inclination. However, slight differences in slope inclination were found for different sites: approximal sites clearly yielded steeper regression lines than buccal/oral sites.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

[Sebastian Fey, Zuben and Erlen (Thurgau), 1791-1825].

Sebastian Fey (1791-1825) was a young veterinarian of the Swiss canton of Thurgau (founded 1803). He had first made an apprenticeship as a country veterinarian, and his educational background was very modest. But his zealousness to come out of the darknesses of empirical veterinary medicine was very strong. With a cantonal scholarship, he managed to spend a year (1813/14) at the Vienna Veterinary School. He was one of the first members of the Swiss Veterinary Association founded 1813, and published a series of papers in the early volumes of its Schweizer Archiv für Tierheilkunde, on from 1816. He also had two monographs printed in Constance publishing houses. In the second of them, he confirmed and defended the statements of Skellett, a British pioneer of foetotomy in cattle.

History, 19th Century

Wearable digital speech processor for cochlear implants using a TMS320C25.

Based on a single-chip DSP (TMS320C25, Texas Instruments) a programmable battery-operated sound processor with a digital encoder interface for the Nucleus-22 cochlear implant (CI) was built. The number of quasi-simultaneously addressed electrodes is only limited by the selected pulse width and the maximum rate of stimulation and can be as high as 10 electrodes at 300 Hz repetition rate. Implementation of various processing strategies (formant or channel vocoder, filterbank, zero crossings, etc.) is possible as well as sophisticated adaptive noise reduction. Programs and stimulation parameters are stored in electrically erasable memory and may be updated via a host computer. The built-in analog output may be used for single-channel stimulation or acoustic verifications of the sound processing algorithms. The power consumption with current 16K word data memory and at maximum stimulation rate is about 1 Watt, which necessitates recharging of batteries after 11 h.

Cochlear Implants