PubMed Health⌕ Search

Biomedical subjects

C Serago

Publications and source records attributed to C Serago.

6 recordsLinked to original sources

A pencil beam algorithm for proton dose calculations.

The sharp lateral penumbra and the rapid fall-off of dose at the end of range of a proton beam are among the major advantages of proton radiation therapy. These beam characteristics depend on the position and characteristics of upstream beam-modifying devices such as apertures and compensating boluses. The extent of separation, if any, between these beam-modifying devices and the patient is particularly critical in this respect. We have developed a pencil beam algorithm for proton dose calculations which takes accurate account of the effects of materials upstream of the patient and of the air gap between them and the patient. The model includes a new approach to picking the locations of the pencil beams so as to more accurately model the penumbra and to more effectively account for the multiple-scattering effects of the media around the point of interest. We also present a faster broad-beam version of the algorithm which gives a reasonably accurate penumbra. Predictions of the algorithm and results from experiments performed in a large-field proton beam are presented. In general the algorithm agrees well with the measurements.

Algorithms↗

Hyperfractionated radiation therapy and concurrent 5-fluorouracil, cisplatin and mitomycin-C in head and neck carcinoma. A pilot study.

Seventeen patients were entered into a Phase I/II trial of concurrent hyperfractionated radiation therapy (7,440 cGy total dose; 120 cGy b.i.d.) combined with constant infusion of 5-fluorouracil (5-FU) (1,000 mg/m2/24 hours for 72 hours) and cisplatin (DDP) (50 mg/m2) for a total of three cycles. Thirteen patients had Stage IV disease; three, Stage III disease; and one, Stage II hypopharyngeal disease. Thirteen of 17 patients had positive cervical lymph nodes, and the mean size of the largest lymph node was 5.5 x 5.1 cm. The patients were not treated with planned adjunctive surgery except for one patient who had a radical neck dissection for massive, rapidly growing cervical adenopathy, which recurred promptly within 1 month before the initiation of protocol therapy. After the initial six patients were entered, mitomycin-C (Mito 8 mg/m2) was added during the second cycle. All the patients completed the planned course of radiotherapy with a median dose of 7,440 cGy and a mean dose of 7,248 cGy except for two patients who died--one from toxicity and the other, suicide. The predominant toxicity was mucositis, which was grade 3/4 in 11 of 15 patients, resulting in an average interruption of radiation therapy of 12 days. Weight loss was significant and was on the average 12% of baseline weight. Hematological toxicity was mild in the 5-FU/DDP group (only one grade 3 toxicity of six) and severe in the 5-FU/DDP/Mito-treated patients (five of eight patients having grade 3/4 toxicity including one leukopenic pneumonitis death). Additional toxicity included one parapharyngeal cellulitis, which responded to antibiotics. Noncompliance with the complex regimen was only seen in three patients. One patient refused b.i.d. radiation therapy, and one patient refused further chemotherapy after the first cycle. Additionally, one patient who had a severe ethanol withdrawal reaction during the first cycle of 5-FU/DDP did not receive further chemotherapy. The complete response rate of both primary site and neck by the protocol regimen alone was 71%. However, two patients, one from each group, did undergo salvage neck dissection, and the locoregional control is currently 73%, with a mean follow-up time of 18.4 months. The feasibility of combining hyperfractionated radiation therapy with aggressive concurrent chemotherapy was demonstrated. The response and local control rate justifies the added toxicity of concurrent chemotherapy and radiation therapy.

Adult↗

Conservative surgery and radiation therapy for early stage breast cancer. Can large trial experiences be reproduced in a community hospital setting?

Conservative surgery and radiation therapy were used to treat 212 patients with AJC clinical Stage I or II breast carcinoma at the Baptist Hospital of Miami. All had lumpectomy and most axillary lymph node dissection, followed by breast irradiation to a dose of 45 Gy and a boost dose of 14 to 16 Gy to the surgical bed. Median follow-up was 55 months. The five-year actuarial local control and survival rates were 94% and 86% respectively. Eighty-six percent of the patients had excellent or good cosmetic results with minimal differences between the treated and untreated breasts. Treatment-related complications were minor and infrequent. These results appear comparable to retrospective reviews at major university centers and ongoing prospective randomized trials.

Breast Neoplasms↗

Regional pulmonary ventilation measurements by xenon enhanced dynamic computed tomography: an update.

New developments in computed tomographic technology permit rapid, serial images that may yield information concerning tracer kinetics through a large tissue volume. One possible application of these developments is the derivation of local lung ventilation by observing the temporal changes of stable xenon concentrations. Preliminary results from six multilevel ventilation studies in dogs demonstrate that the lung may be repeatedly imaged during reproducible phases of respiration even when interscan table incrementation is employed to survey a number of tissue segments and breathing is permitted between scans. In addition, subanesthetic xenon concentrations provide adequate enhancement for possible quantification.

Animals↗

Alanine EPR dosimeter response in proton therapy beams.

We report a series of measurements directed to assess the suitability of alanine as a mailable dosimeter for dosimetry quality assurance of proton radiation therapy beams. These measurements include dose-response of alanine at 140 MeV, and comparison of response vs energy with a parallel plate ionization chamber. All irradiations were made at the Harvard Cyclotron Laboratory, and the dosimeters were read at NIST. The results encourage us that alanine could be expected to serve as a mailable dosimeter with systematic error due to differential energy response no greater than 3% when doses of 25 Gy are used.

Alanine↗

Photon contamination in 8-20-MeV electron beams from a linear accelerator.

The amount of x-ray contamination near the surface of a phantom irradiated with electron beams was measured directly. Measurements were done to ascertain if photon contamination in the beam contributes a higher dose to the more superficial layers of an irradiated medium than indicated by conventional methods. A 1.4-kG magnetic field was used to deflect the electron beams generated by a Philips SL/75-20 linear accelerator. The electron energies studied were 8, 10, 12, 14, 17, and 20 Mev. After sweeping the electron beam, a significant amount of photon contamination was measured in all cases. The characteristic qualities of the photon contamination were measured directly in a water tank. They were found to agree with those of bremsstrahlung spectra generated in a thin target with a virtual source at the location of the scattering foil.

Electrons↗