PubMed Health⌕ Search

Biomedical subjects

C Simona

Publications and source records attributed to C Simona.

12 recordsLinked to original sources

Reliability of single and double probing attachment level measurements.

Clarification of the reliability associated with probing attachment level measurements and with diagnostic rules derived from them is necessary to examine the potential of these measurements as reliable markers of the disease process and as an outcome measure in clinical treatment studies. The purpose of the present study was to describe and compare the longitudinal reliability of single and double probing attachment level measurable by estimating false positive and false negative rates. In 20 systemically healthy adults with untreated advanced adult periodontitis, probing attachment levels and probing depth were measured at 6 sites in all teeth at the start of the study, and every 30 days thereafter for 11 months. Attachment levels were double measured, using acrylic onlays providing reference points and an electronic pressure sensitive probe. Attachment loss from baseline of 2.5 mm or more was used to accept dynamic attachment loss. The statistical methods for the cross-sectional analysis included mean absolute differences between double measurements and cross-correlations. Longitudinal analyses, expressing estimates of diagnostic error rates were made using maximum likelihood methods. 5 measurement protocols were compared. The results showed that the mean absolute difference between replicate measurements was 0.095 mm in bicuspids and 0.107 mm in molars. The mean absolute differences decreased over time from 0. 128 mm in visit 3 to 0.08 mm in visit 7. Correlation coefficients for replicate measurements were higher than 0.98. In general, false positive rates were markedly lower (< or = 0.02) than false negative rates (< or = 0.31). The relative sample size required to obtain comparable statistical power, was minimized in premolars when using the first of 2 measurements or the mean of 2 measurements, and in molars when using the first of 2 measurements. The methodology used in the present study provides guidelines for designing clinical studies which maintain statistical power by balancing off examiner reliability and sample size.

Acrylic Resins↗

Clinical furcation diagnoses and interradicular bone defects.

The purpose of the present study was to assess associations between clinical depth of involved furcations and their bony defect depth. Twelve patients with moderate to advanced periodontitis in molars were recruited for clinical evaluation of furcation involvement by 6 dentists. Two groups of 3 dentists were assigned to the right or left half of the dentition. All dentists assessed the clinical depth of involvement of the furcations using the Ramfjord index (2 mm) in patients 1 through 6, and using the Hamp index (3 mm) in patients 7 through 12. Diagnoses were made with calibrated and uncalibrated Nabers 2 probes. After the clinical assessments the patients received full mouth scaling and root planing. After reevaluation the molars were surgically exposed. During surgery the depth of the bony furcation defects was assessed using horizontal probing and impressions. Clinically assessed depth of furcation involvement was then compared with the surgical measurements. A total of 1,180 clinical furcation diagnoses were available, of which 426 could be surgically evaluated using both the straight probe and the impressions. These evaluations were done in a total of 72 furcations using probe and impressions. For the Ramfjord index, 5% of the clinical degree 1, 40% of the degree 2, and 43% of the degree 3 readings were overestimations. For the Hamp index, 7% of degree 1, 24% of degree 2, and 0% of degree 3 readings were overestimations. These clinical diagnoses were overestimations. Forty-three percent of surgical degree 3 involvements were not recognized when using the Ramfjord index, and 27% when using the Hamp Index. These results suggest that furcation diagnosis is of limited validity.

Adult↗

Time-related changes of in vivo projection errors in standardized radiographs.

Subtraction radiography requires radiographs made with identical projection geometry. Recently a new radiographic aiming device and an x-ray beam manipulator made it possible to repeat radiographic exposures in vivo with small angular errors and to measure the angular errors occurring. The purpose of the present investigation was to study in vivo the measuring error and the angular errors produced by this new method at different time points (0, 6, and 12 months) and to assess the effect of different time intervals between exposures (0, 6, and 12 months). Ten sites were investigated. At each time point 2 exposures were made, resulting in 6 radiographs per site. For each pair of radiographs the measuring errors occurring during analysis and the projection errors were determined for each time point and for each time interval. Friedman's test and t-test were used to evaluate the errors. A difference in the measuring error of the system and in the angular errors at the time points 0, 6, and 12 months could not be detected. A time interval between exposures also did not have an effect on the measuring error. Time did not affect the vertical and horizontal angular errors measured between the radiographs producing the smallest oblique error. A combination of radiographs producing the largest oblique angular error showed an increase of the horizontal and vertical angular errors when the time interval increases. These effects, however, were not statistically significant.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

In vivo scaling and root planing forces in molars.

The purpose of the present study was to assess in vivo scaling and root planing forces in molars of periodontitis patients. Ten dentists and 10 dental hygienists scaled and root planed the mesial and distal aspect of one first molar, using Gracey curets 11/12 and 13/14. Scaling and root planing forces were recorded using a piezo-electric receiver, an electronic transducer, and an analogous writer. The forces were recorded in mV and converted into Newtons (N). Three different types of forces were recorded: positive forces during working strokes and positive and negative forces during preparation of working strokes. Multivariate repeated measures analysis of variance was used to assess differences in force between curet types. The mean positive scaling forces exerted with curet 11/12 were statistically significantly (P = 0.0005) greater than the corresponding forces exerted with curet 13/14 in all therapists. The mean positive root planing forces applied with the curet 11/12 were significantly (P = 0.0008) greater than the forces exerted with curet 13/14. The mean positive interstroke forces did not differ between curet 11/12 and 13/14. The mean negative interstroke forces impacting on the soft tissues exerted with curet 11/12 did not significantly differ from curet 13/14 during scaling and during root planing. Therapists differed significantly among themselves for each type of positive and negative force (P < 0.001 in all cases). These results suggest that the extent of instrumentation given to root surfaces in molars depends more on the therapist and on the molar aspect being treated than on the needs of a specific site.

Adult↗

Cross-sectional and longitudinal reliability for clinical measurement of attachment loss.

Progression of marginal periodontitis in humans is characterized by acute exacerbations during short periods of time followed by periods of remission. The analytical procedures used to distinguish actively progressing sites from non-progressing sites within an individual's dentition are controversial. The purpose of the present investigation was to use measurements of probing depth and attachment level from a prospective longitudinal study of episodic periodontal disease progression to examine measurement and diagnostic reliability. In 10 systemically healthy adult human subjects with untreated advanced periodontitis, probing depth and attachment levels were measured at baseline and every 30 days for 10 to 12 months. Measurements were made at 6 sites of each tooth using an acrylic onlay as a reference point and a pressure sensitive probe. Replicate measurements were made on sites showing apparent changes in attachment loss of 2 mm or more in a month, and their contralateral counterparts. Cross-sectional reliability was described by means and standard deviations for the absolute differences between replicate measurements: 0.63 +/- 0.87 mm for anterior teeth, 0.58 +/- 0.80 mm for premolars and 0.69 +/- 0.91 mm for molars. The mean differences tended to decrease with increasing time on study and tended to be greater in deeper pockets. Longitudinal reliability was described by analyzing site-specific serial attachment level measurements across the study time period. Maximum likelihood methods were used to estimate false positive and false negative diagnostic rates associated with the diagnosis of attachment loss based on minimum threshold levels of 1 and 2 mm. The use of a 1 mm threshold resulted in estimated false positive rates of 0.08 to 0.11 and false negative rates of 0.11 to 0.15.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

In vivo determination of radiographic projection errors produced by a novel filmholder and an x-ray beam manipulator.

Subtraction radiography requires radiographs made with identical projection geometry. The purpose of the present investigation was to develop and evaluate a new in vivo method to measure angular radiographic projection error. This included the development of a system for accurate control of the x-ray beam angulation relative to the intraoral film and the evaluation of the in vivo projection errors (equivalent to the "angular difference" between repeated exposures) produced by the new system. A filmholder, an x-ray beam manipulator, and an aiming device were newly constructed. Reference wires were attached for measuring the projection error on the filmholder and on the 22 bicuspids at the sites of investigation in 16 patients. Two exposures using standardized projection conditions were made of each site. The relative position of the reference wires on the duplicate radiographs was used to calculate the angular difference in the direction of the x-ray beam which occurred between the 2 exposures. Triplicate measurements allowed the determination of measurement error. The angular projection errors were measured in a horizontal and vertical direction. The reference wires allowed determination of the angular projection errors relative to the filmholder, relative to the dentition and the angular error due to the repositioning of the filmholder in the patient's mouth. The average projection errors deviated only slightly from zero. The largest deviation registered was -0.11 degrees. This applies to the horizontal and vertical direction and all relationships. The standard deviations varied between 0.403 degrees and 0.697 degrees. This applies to the standard deviation for all relationships in the horizontal, the vertical, and the oblique directions. The measuring error found from the triplicate measurements had a standard deviation of 0.08 degrees to 0.19 degrees depending on the distance between the reference wires. This new system for controlling in vivo projection errors seems to provide highly standardized radiographs in vivo. The new measuring system proved to be accurate enough to measure the in vivo projection errors between repeated radiographs produced with the new filmholder and x-ray beam manipulator. The in vivo errors produced by the new system are markedly smaller than all in vivo and in vitro errors previously reported in the literature.

Adult↗

Root substance removal by scaling and root planing.

The amount of root substance removed by scaling and root planing is largely unknown. The present study evaluated in vitro the root substance loss caused by a defined number of working strokes at known forces. Forty extracted teeth with loss of connective tissue attachment into the middle third of the roots were washed and embedded in plaster, leaving one entire corono-apical tooth aspect exposed. The teeth were reproducibly repositioned in a bench-vise, where a profilometer repeatedly measured root surface levels at the same location. In a standard area of the roots a total of 40 working strokes were applied. Low forces were used in 30 teeth and high forces in 10 teeth. The forces were recorded using a piezo-electric receiver built into the upper shank of the curet. Root substance loss was measured after 5, 10, 20, and 40 working strokes. The results showed that the mean low force used per working stroke across all 40 strokes was 3.04 Newtons for the low forces, and 8.48 Newtons for the high forces. Mean cumulative loss of root substance across 40 strokes was 148.7 microns at low forces, and 343.3 microns at high forces. The mean force per stroke increased slightly across the 40 strokes, while substance removal per stroke decreased. Substance removal per stroke during strokes 1 to 5 was 6.8 microns using low forces and 20.6 microns using high forces. During strokes 21 to 40 mean removal per stroke was 2.3 microns at low forces, and 5.6 microns at high forces. These results suggest that high forces remove more root substance, and loss per stroke becomes less with increasing numbers of strokes.

Dental Scaling↗

In vivo scaling and root planing forces.

The purpose of the present study was to assess the scaling and root planing forces exerted in vivo. Ten dentists and 10 dental hygienists scaled and root planed one aspect of an incisor in an adult patient with untreated advanced periodontitis. During scaling and root planing forces were recorded using a piezo-electric receiver, an electronic transducer, and an analogous writer. The forces were recorded in mA and converted into Newtons (N). The results showed that the mean scaling force applied by dentists was 5.70 N and ranged between 1.01 to 10.35 N. The corresponding values for dental hygienists were a mean of 5.38 N, and a range of 1.52 to 15.73 N. The root planing forces in dentists reached a mean of 4.62 N, and ranged between 0.86 to 8.88 N. For hygienists, these values were 4.58 N with a range of 1.56 to 10.59 N. Negative forces impacting on the periodontal soft tissues were also recorded. They were not present in all therapists, but consistently at work within specific therapists. During scaling these forces reached a mean of -0.40 N in dentists and -0.47 N in dental hygienists. During root planing, these forces were mean -0.59 N in dentists, and -0.81 N in hygienists. There were no statistically significant differences between scaling forces and root planing forces, nor between forces used by dentists and hygienists (P greater than 0.05). However, there were significant differences between the force levels of the individual therapists for all positive forces (P = 0.0001), and for negative forces during root planing (P = 0.0001). The technology and information provided by this investigation may enable studies evaluating clinical effectiveness of scaling and root planing doses.

Adult↗

[Effect of electrically powered dental devices on cardiac parameter function in humans].

Electrically powered devices represent a hazard for patients with cardiac pacemakers. The aim of the present investigation was an in vivo evaluation of possible interactions between electrically powered dental instruments and the function of artificial pacemakers in humans. In 26 patients with artificial pacemakers, different dental instruments were applied, including air scaler, ultrasonic curets, electric pulp tester and electrotome. These devices were applied at highest intensity. Immediately prior to, during, and immediately after applications of these instruments, the pulse rate and the electrocardiogram (EKG) were recorded. The EKG recordings were assessed for irregularities in the distances between the pacemaker peaks. The dental devices were assessed for magnetic fields or induction tension. The results showed that none of the dental devices caused an irregularity in the pacemaker function. The air scaler, Piezon ultrasonic curet and the electric pulp tester caused no measurable magnetic fields. The Sonus 2 ultrasonic curet and the electrotome magnetic fields were measured up to 60 and 50 cm, respectively. All dental devices caused induction tension. The highest value was produced by the electrotome. It seems that cardiac pacemaker function is not affected by electrically powered dental devices. However, there remains a risk in relation to older pacemakers or defective dental devices.

Adult↗

[Episodic progression of periodontitis--histologic associations].

Periodontal lesions are primarily diagnosed using the periodontal probe. Using site-specific probing attachment level measurements in defined time intervals, dentists can identify patients and dentition segments that suffer temporarily from a high periodontitis progression rate. The present article describes whether sites where clinical measurements suggested a high progression rate had tissue characteristics different from nonprogressing sites. Ten patients with untreated advanced adult periodontitis were monitored for 10 months by measuring clinical parameters every 30 days. These parameters were gingival index, plaque index, bleeding index, bleeding on probing, probing depth and probing attachment levels. Every month pairs of contralateral sites were sought where one site had lost 2 mm (P-2) or more (P greater than 2) probing attachment (P-sites) and the other site had not (C-site). From these sites supracrestal soft tissue biopsies were taken. After histological processing, a first analysis determined the number of inflammatory cells in 9 standard areas in P- and C-biopsies. A second analysis evaluated cell populations at the apical end of the junctional epithelium. The results showed that bleeding on probing, probing depth and probing attachment loss were statistically significantly greater at P-sites. At C-sites there were only few inflammatory cells. At P-2-sites there were numerous inflammatory cells, and in P greater than 2-sites the number of these cells was statistically significantly greater than in corresponding control sites. The cell populations at the apical end of the junctional epithelium were different between P- and C-sites. At P-sites, the percentage of mast cells, monocytes/macrophages and plasma cells was statistically significantly greater than at C-sites. At C-sites, the percentage of fibroblasts was statistically significantly greater than at P-sites. These results demonstrate that clinical probing identifies episodes of periodontitis progression, which are associated with pronounced changes in tissue characteristics, namely greater numbers of inflammatory cells.

Dental Plaque Index↗

Episodic probing attachment loss versus pocket depth: bacterial morphotype associations.

Marginal periodontitis in humans is characterized by phases of clinical disease progression, which are interspersed between periods of quiescence. The purpose of the present study was to compare subgingival bacterial populations from periodontal sites undergoing episodic probing attachment loss with bacterial populations from non-progressing lesions. Probing depth and attachment levels were measured in 10 adult patients at baseline, and every 30 days thereafter for 10 months. Pairs of corresponding contralateral sites were identified where one site had lost probing attachment within the previous month (P) and the other site had not (C). Subgingival bacterial samples were obtained from these sites and analyzed using darkfield microscopy. Motile forms, spirochetes, curved and straight rods, filaments, coccoid cells, fusiforms, and the total number of bacteria were assessed. The results showed that median pocket depth and attachment change were statistically significantly greater in P-sites as compared to C-sites. There was no significant difference in bacterial populations between P- and C-sites (p greater than 0.15). Motile forms, spirochetes, and total number of bacteria were positively correlated with pocket depth in P-sites, while in C-sites the same was true only for curved rods. These results suggest that darkfield microscopy of subgingival bacteria in humans represents primarily pocket depth.

Adult↗

Episodic probing attachment loss in humans: histologic associations.

Marginal periodontitis in humans is characterized by episodes of probing attachment loss followed by periods of quiescence. The purpose of the present study was to assess characteristics of the inflammatory infiltrate in periodontal lesions where episodic probing attachment loss had occurred within the previous month. In 10 systemically healthy adult human subjects with untreated advanced periodontitis, probing attachment levels were measured at baseline and every 30 days thereafter for 10 months. Measurements were made at six sites of every tooth using an acrylic onlay as a reference point and a pressure sensitive probe. Sites where double measurements confirmed that probing attachment loss of 2 mm or more had occurred within the previous month were identified (P-sites), as were corresponding contralateral non-progressing sites (C-sites). Biopsies of the supracrestal tissues were taken from these sites, processed, and cut in 1 mu sections for histologic evaluation. Counts of inflammatory cells in standard areas of the sections were compared between P and C sites. The results indicated that 5.04% of 1566 sites under investigation lost probing attachment during the 10-month observation period. Inflammatory cell counts were higher in P-sites as compared to C-sites. P-sites with more than 2 mm attachment loss (P greater than 2 sites) had significantly more inflammatory cells within standard areas at the apical end of the junctional epithelium than non-progressing C-sites (P less than 0.02). There was no significant difference in counts between P-sites progressing 2 mm (P-2 sites) and corresponding C-sites.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗