PubMed Health⌕ Search

Biomedical subjects

C Strahm

Publications and source records attributed to C Strahm.

10 recordsLinked to original sources

Reliability of perioperative SSEP recordings in spine surgery.

OBJECTIVE: The reproducibility and clinical reliability of perioperative somatosensory-evoked potentials (SSEP) were prospectively evaluated in uneventful scoliosis surgery. The influence of anesthesia owing to induction of total intravenous anesthesia (TIVA) upon preoperative SSEP and the variability of intraoperative SSEP were calculated. The potential effect of spine surgery was assessed by comparing pre- to postoperative SSEP. METHODS: A total of 2,143 pre-, intra- and postoperative tibial and median SSEP recorded in 25 patients undergoing spine surgery owing to idiopathic scoliosis were analyzed. The anesthesia protocol consisted of a computerized target controlled infusion (TCI) device for propofol and intravenous application of an opioid. RESULTS: Anesthesia induced a significant and comparable prolongation of the tibial SSEP onset, P40 and P60 latencies, while the N50 latency was less changed. Throughout anesthesia, latencies of median (onset, N20, P25 and N35) and tibial (onset, P40, N50 and P60) SSEP showed mean variations of less than 6%. The intraoperative SSEP amplitudes were less stable with a relative standard deviation of 30-40%. In uneventful spine surgery, the postoperative tibial SSEP were not significantly changed in comparison to preoperative recordings. CONCLUSIONS: By using a standardized anesthesia protocol, the impact of anesthesia on preoperative SSEP can be predicted. Furthermore, the controlled application of sedatives and analgesics allows recording of stable SSEP parameters for intraoperative monitoring purposes. As in uneventful spine surgery pre- to postoperative SSEP are unchanged the latter comparison can be applied as an additional perioperative neuromonitoring procedure to assess the influence of spine surgery or other invasive interventions on spinal cord function.

Adolescent↗

Light maxillary expansion forces with the magnetic expansion device. A preliminary investigation.

An active maxillary magnetic expansion device (MED) was developed to be used clinically. The aim was to show the effects of light and continuous forces producing less traumatic stimulation of maxillary sutural growth than a conventional rapid maxillary expansion device. In this study, two different types of appliances were used on six patients between 7 years 4 months and 16 years 2 months: the first type was bonded, the other one used bands. For better appreciation, four implants were placed on each patient: two apically between central and lateral incisors, and two between second premolars and molars. A standardized radiographic technique was used to take occlusal radiographs, and postero-anterior and lateral headplates. The results varied according to the age and the appliance used. The skeletal effect with the banded MED was between 16 and 77 per cent, and for the bonded MED 0 and 25 per cent in comparison to the overall expansion. It seems that 250-500 g of continuous magnetic forces can produce dental and skeletal movements in a light force expansion concept, but further studies with larger samples are needed to make firm conclusions.

Activator Appliances↗