Regional differences in left ventricular response to atrial pacing in the dog: mapping of segmental function by two-dimensional echocardiography.

Two-dimensional echocardiography was applied in 10 closed-chest dogs to evaluate, in several left ventricular (LV) short-axis cross sections and subsegments, the regional contractile response to right atrial pacing. Compared with sinus rhythm (81 +/- 10 beats/min), which exhibited a moderate 7.2 +/- 12.0% (mean +/- standard deviation) base-to-apex increment in function, this gradient was significantly augmented to 34 +/- 12% by pacing at a heart rate of 180 beats/min. Measurements of wall thickening and perimeter shortening exhibited similar trends. Differences also were observed in subsegments of individual cross sections: in sinus rhythm the base-to-apex difference in function was relatively minor in the anterior and lateral aspects of the left ventricle (-9.1 +/- 18% and -1.9 +/- 19%), whereas a significant increase was noted in posterior and midseptal zones (18 +/- 17% and 22 +/- 30%). In response to pacing, the anterior and lateral wall base-to-apex gradients were significantly augmented (25 +/- 8% and 35 +/- 34%), but there was no further change in the posterior or septal regions. In conclusion, apical regions of the canine left ventricle responded to right atrial pacing with significant augmentation of contractile function, whereas more basal levels showed little response. Circumferentially, response to atrial pacing was most pronounced in the anterior and lateral segments.

Animals↗

Assessment of right ventricular function using two-dimensional echocardiography.

With the use of two-dimensional echocardiography (2DE), we analyzed apical and subcostal four-chamber views for evaluation of right ventricular (RV) function in 30 individuals as compared to RV ejection fraction (RVEF) obtained by radionuclide angiography. In addition to previously reported parameters of changes in areas and chords, a new simple measurement of tricuspid annular excursion was correlated with RVEF. A close correlation was noted between tricuspid annular plane systolic excursion (TAPSE) and RVEF (r = 0.92). The RV end-diastolic area (RVEDA) and percentage of systolic change in area in the apical four-chamber view also showed close correlation with RVEF (r = -0.76 and 0.81); however, the entire RV endocardium could only be traced in about half of our patients. The end-diastolic transverse chord length and the percentage of systolic change in chord length in the apical view showed a poor correlation with RVEF. The correlation between RVEF and both areas and chords measured in the subcostal view was poor. It is concluded that the measurement of TAPSE offers a simple echocardiographic parameter which reflects RVEF. This measurement is not dependent on either geometric assumptions or traceable endocardial edges. When the endocardial outlines could be traced, the apical four-chamber view was superior to the subcostal view in assessment of RV function.

Adult↗

Hyperemic response of intracoronary contrast agents during two-dimensional echographic delineation of regional myocardium.

Several intracoronary echo contrast agents that provided satisfactory regional myocardial delineation with two-dimensional echocardiography were compared in 15 dogs and their effects on coronary blood flow were examined. Reproducible delineation of myocardium subserved from the intracoronary echo contrast injection site was achieved with hand-agitated agents containing greater than or equal to 30% Renografin, greater than or equal to 30% glucose, greater than or equal to 30% sucrose or 6% dextran. After a 2 cc injection of the echo contrast agent, peak hyperemic augmentation of coronary flow was 56.7 +/- 54.4% for 6% dextran, 116.0 +/- 71.1% for 30% Renografin, 119.3 +/- 47.8% for 30% sucrose, 173.8 +/- 38.3% for 30% glucose. Although, 6% dextran resulted in the lowest and shortest hyperemic response of the four agents, computer-derived echo contrast appearance-disappearance analysis indicated a prolonged myocardial contrast decay half-life (21.0 seconds). On the other hand, 30% Renografin had a more rapid myocardial echo contrast washout (T 1/2 = 15.5 seconds), but a significantly greater hyperemic effect was observed. It is concluded that development of echo contrast agents for myocardial contrast two-dimensional echocardiographic assessment of myocardial perfusion will require consideration of alterations in coronary flow due to contrast-induced hyperemia.

Animals↗

Two-dimensional contrast echocardiography. I. In vitro development and quantitative analysis of echo contrast agents.

To facilitate the passage of echo contrast agents through the microcirculation and the echocardiographic study of myocardial perfusion, ultrasonic energy (sonication) was employed to produce contrast agents consisting of relatively uniform, stable and small (less than 10 mu diameter) gaseous microbubbles suspended in liquid solutions. The size and persistence of the microbubbles was verified by light microscopy and an in vitro system were employed for comparative assessment of peak echo amplitude and echo persistence characteristics of various contrast agents. The study indicated that although a variety of hand-agitated and sonicated contrast agents provided satisfactory echo intensities, sonication was clearly superior to the hand-agitation method, because sonication produced smaller, more uniform and more stable microbubbles that may be suitable for myocardial contrast echocardiography. It is concluded that of the contrast agents examined, sonicated solutions of sorbitol (70%) and dextrose (70%) appeared to have particular potential because of the small sizes of the microbubbles (6 +/- 2 and 8 +/- 3 mu, respectively) and their prolonged in vitro persistence. The use of sonication to produce standardized, small and stable microbubbles should facilitate physiologic passage of the contrast agent through the capillary beds and allow two-dimensional imaging of the left heart myocardium during right-sided, aortic root, coronary sinus or intracoronary contrast injections.

Contrast Media↗

Verification of myocardial contrast two-dimensional echocardiographic assessment of perfusion defects in ischemic myocardium.

Myocardial contrast two-dimensional echocardiography was used in 21 closed chest dogs to assess its ability to delineate the extent of underperfused acutely ischemic myocardium. An agitated saline-Renografin echocardiographic contrast agent was injected into the left main coronary artery after left anterior descending coronary artery occlusion, and the size of the contrast echo-free area characterizing the perfusion defect was outlined in short-axis cross sections of the left ventricle. In 13 dogs, monastral blue dye was injected after 45 minutes of coronary artery occlusion and before sacrifice to provide anatomic delineation of underperfused zones in equivalent sections. Perfusion defects assessed by contrast two-dimensional echocardiography correlated well with those delineated by monastral blue dye (r = 0.91). Contrast echocardiographic study was also performed in eight other dogs at 5 hours of occlusion, after which infarct size was measured with triphenyl-tetrazolium-chloride. Contrast echocardiographic outline of the perfusion deficiency correlated but slightly overestimated the extent of necrosis (r = 0.88). It is concluded that contrast two-dimensional echocardiography can detect and outline the underperfused "risk area" during acute coronary artery occlusion, and may also permit assessment of the extent of myocardial infarction.

Animals↗

Correlation of myocardial echo contrast disappearance rate ("washout") and severity of experimental coronary stenosis.

The relation between experimental coronary stenosis and myocardial contrast echo disappearance rate ("washout") was investigated in anesthetized closed chest dogs. Of 13 dogs, 8 had serial contrast echographic studies with two successive degrees of coronary stenosis (50 and 70%) produced by threading stenotic plugs into the proximal left circumflex coronary artery. Studies were repeated with complete coronary occlusion achieved by inflation of an intracoronary balloon immediately proximal to the plugs. Myocardial contrast echograms were recorded in short-axis cross sections of the left ventricle after intracoronary injection of 2 ml hand-agitated saline-Renografin solution through a catheter placed in the coronary artery. An echo contrast washout index (t 1/2) was measured by digital processing computer analysis of successive end-diastolic images obtained by two-dimensional echocardiography during myocardial contrast agent injection. The injection to injection correlation coefficient of these t 1/2 measurements was satisfactory (r = 0.87, standard error of estimate 4.8 seconds). Involved segment t 1/2 measurements were found to be significantly altered by intracoronary stenosis and occlusion, ranging from 23 +/- 6 seconds (mean +/- standard deviation) in the control state, 29 +/- 9 and 44 +/- 10 seconds for 50 and 70% stenosis, respectively, and 104 +/- 35 seconds for total occlusion. It was concluded that myocardial contrast two-dimensional echocardiographic measurement of t 1/2 appears to be a useful index of the degree of coronary stenosis.

Animals↗

Myocardial contrast two-dimensional echocardiography: comparison of contrast disappearance rates in normal and underperfused myocardium.

A computer algorithm was developed and applied to measure brightness decay rates of myocardial contrast opacification observed with two-dimensional echocardiography (2DE). An agitated mixture of diatrizoate meglumine and saline (Renografin-saline) was injected into the left main coronary artery of 17 closed-chest dogs during the control state as well as after placement of an intracoronary plug to induce 85% stenosis in the left anterior descending coronary artery (LAD) in five dogs. In 12 dogs, injections were also performed distally to complete intracoronary balloon occlusion of the LAD. For each injection, up to 35 electrocardiographic-gated, end-diastolic 2DE frames were digitized into an image-processing computer that determined mean pixel brightness of each of 12 myocardial segments per 2DE short-axis cross-section. Time-activity curves for each segment were generated, and contrast decay half-life (t 1/2) was calculated. Mean t 1/2 for control-state injections was found to be 24.1 +/- 7.7 sec, as opposed to 293.8 +/- 164.5 sec after complete coronary occlusion (p less than .001). In the five dogs in which 85% LAD stenosis was induced, prolongation of contrast t 1/2 from 18.3 +/- 8.9 sec during control to 44.3 +/- 21.0 sec (p less than .001) after plug insertion occurred in myocardial segments subserved by the stenosed vessel. No significant change occurred in segments that were not supplied by the stenosed vessel (21.9 +/- 9.1 sec during control vs 24.9 +/- 11.6 after plug insertion into the LAD). A reproducibility study of injection-to-injection t 1/2 in the control state indicated a correlation coefficient of r = .84 and a standard error of the estimate (SEE) equal to 5.86 sec, while interobserver t 1/2 reproducibility was r = .91 and SEE = 5.21 sec. The t 1/2 measurement derived by computer analysis of myocardial contrast 2DE may serve as an index for characterization of regional myocardial blood flow and may be applicable to evaluate interventions that alter perfusion.

Animals↗

[Detection of a shunt flow through a defect in secundum atrial septal defect by right parasternal approach using pulsed Doppler echocardiography].

Pulsed Doppler echocardiography combined with two-dimensional echocardiographic (2-DE) system was performed to detect a shunt flow through a defect in the interatrial septum (IAS) in patients with secundum atrial septal defect (ASD) utilizing right parasternal approach (RPA). RPA is a method which provides an accurate evaluation of a defect in the IAS on a 2-DE image by placing a transducer on the right of the sternum because the ultrasonic beam passes in a plane almost perpendicular to the IAS. The subjects consisted of 20 patients with ASD (25 +/- 22 yrs) diagnosed by cardiac catheterization or 2-DE with peripheral contrast material injection, and 10 cases of healthy subjects (34 +/- 18 yrs). Defects in the IAS were clearly visible in 19 patients with ASD on 2-DE images by RPA. By placing the sample volume in the center of the defect, Doppler flows could be obtained in 17 of them. In 13 with sinus rhythm, except a case of Eisenmenger syndrome, Doppler signals showed mainly a laminar flow toward the transducer (positive flow), but a transient flow of low velocity away from the transducer (negative flow) was also observed. The positive flow had its peaks in late systole and atrial systole and occasionally in mid-systole, early diastole and mid-diastole. The negative flow occurred in early systole, mid-diastole and late diastole. In a patient with Eisenmenger syndrome and tricuspid regurgitation (TR), a negative turbulent flow was observed from early systole to mid-diastole. In three patients with atrial fibrillation, Doppler signals were variable. The Doppler echogram of a patient with atrial fibrillation but no complication showed a laminar positive flow with its peaks in late systole and mid-diastole, and a negative flow in early systole. One patient with atrial fibrillation and TR had a systolic negative turbulent flow and a mid-diastolic laminar positive flow. In a patient with TR and mitral regurgitation, the Doppler echocardiogram showed a laminar positive flow throughout the entire cardiac cycle with its peaks in early diastole and mid-diastole. Doppler signals from the left atrium (LA) to the right atrium (RA) through a defect coincided in timing with the appearance of negative contrast echo from the defect to the RA on 2-DE image and signals from the RA to the LA coincided with the appearance of the contrast echo into the LA from the RA through the defect. Doppler signals disappeared after the closure of the defect in all six patients examined.(ABSTRACT TRUNCATED AT 400 WORDS)

Adolescent↗

Echocardiographic evaluation of normal and prolapsed tricuspid valve leaflets.

The tricuspid valve was examined by 2-dimensional (2-D) echocardiography in 14 patients with tricuspid valve prolapse (TVP) and in 16 normal subjects. Individual leaflets were identified anatomically and for frequency of prolapse. Maximal and minimal anular sizes were measured. Multiple tomograms of the tricuspid anulus were recorded at 30 degrees intervals around the tricuspid anulus with the transducer placed at the right ventricular apex. Anuli were reconstructed from the 6 planes and corrected for body surface area. Three leaflets of the tricuspid valve could be anatomically identified in all patients. Prolapse of all 3 leaflets was observed in 6 patients, 2 leaflets in 5 and 1 in 3. Frequency of individual leaflet prolapse was 93% for the septal cusp, 86% for the anterior and 43% for the posterior. Maximal anular circumference and area in TVP were 7.9 +/- 0.6 and 8.9 +/- 1.3 cm2/m2, respectively--significantly larger than values in normal subjects (6.4 +/- 0.5 cm/m2 and 6.1 +/- 0.9 cm2/m2, respectively) (p less than 0.001). Percent reductions in circumference and area in TVP were 14 +/- 3 and 25 +/- 5%, respectively--significantly smaller values than in normal subjects (19 +/- 4 and 33 +/- 4%, respectively). Tricuspid regurgitation (TR) was detected by contrast echocardiography in 7 of 14 patients with TVP. The severity of TR appeared to be minimal in 6 of the 7 patients, and was not associated with an increase in anular size. Thus, TVP is associated with anular dilatation irrespective of associated TR, probably as a primary pathologic characteristic.

Adult↗

Relation between functional response to nitroglycerin and extent of myocardial necrosis in dogs: mapping of the left ventricle by 2-dimensional echocardiography.

The relation between functional response to brief nitroglycerin infusions and extent of myocardial damage was studied sequentially in closed-chest dogs with acute occlusion of the left anterior descending coronary artery. Two-dimensional echocardiography was used to derive segmental left ventricular (LV) function (systolic fractional area change and systolic wall thickening), and this function was compared with the extent of necrosis measured 5 hours after occlusion in equivalent segments of corresponding pathologic slabs. Two-dimensional echocardiographic study before the dogs were killed indicated that remote nonnecrotic segments always responded to nitroglycerin by significant augmentation of segmental LV function. Segments in which necrosis was less than 40% showed a significant nitroglycerin-induced potentiation in segmental LV function. In contrast, segments in which necrosis was greater than 60% had no potentiation with nitroglycerin. In those segments in which eventual necrosis was 60 to 80%, significant nitroglycerin-induced augmentation in segmental LV function was observed only before and 30 minutes after the coronary occlusion. When the degree of necrosis was greater than 80%, no significant potentiation of segmental LV function was observed even as early as 30 minutes after occlusion. Thus, the degree of nitroglycerin-induced potentiation of segmental cardiac function is closely associated with the extent of myocardial necrosis in the particular ventricular segment. Two-dimensional echocardiography coupled with a nitroglycerin potentiation test might be useful for assessment of the viability of ischemic myocardium.

Animals↗

Interventricular septal and free wall dynamics in hypertrophic cardiomyopathy.

Two-dimensional echocardiography was used to analyze interventricular septal and free wall dynamics in eight normal subjects and eight patients with hypertrophic cardiomyopathy. Upper, middle and lower septal and corresponding free wall motion and thickening were analyzed using both fixed and floating reference systems. The lower and midseptal dynamics did not seem to differ significantly between the two groups and the lower septum seemed to move more than the corresponding free wall (probability [p] less than 0.05). The upper septum moved and thickened less than the rest of the septum in both groups (p less than 0.05), but was less dynamic in patients with hypertrophic cardiomyopathy than in normal subjects when the fixed reference system was used (p less than 0.05). It is concluded that the interventricular septum in hypertrophic cardiomyopathy is not akinetic. Previously reported hypokinesia of the septum in hypertrophic cardiomyopathy may be due to sampling of the upper septum by M-mode echocardiography and to the fixed system of reference used by M-mode echocardiography.

Adult↗

Angled interventricular septum on echocardiography: anatomic anomaly or technical artifact?

An acutely angled interventricular septum has been reported to constitute a distinct two-dimensional echocardiographic geometric pattern that may permit a false M-mode echocardiographic recording of asymmetric septal hypertrophy. In light of experience suggesting that the angle between the aortic root and interventricular septum varied with the intercostal space of the transducer, 45 subjects were prospectively studied by two-dimensional and M-mode echocardiography. Parasternal long- and short-axis views were obtained from two to four intercostal spaces in each subject. Two-dimensional echographic cursor-generated M-mode echocardiograms were obtained from the long-axis views; interventricular septal and left ventricular posterior wall thickness was measured from both the two-dimensional and M-mode echocardiograms. On two-dimensional echocardiography, the angle between the aortic root and septum became more acute as a progressively lower intercostal space was used (p less than 0.001). Although no change in septal thickness was apparent, the septal thickness significantly increased as a progressively lower intercostal space was used. On M-mode echocardiography, 21 subjects (47%) demonstrated asymmetric septal hypertrophy (septal/posterior wall thickness ratio greater than 1.3) from at least one intercostal space, but this was confirmed by the two-dimensional technique in only 4 subjects (9%). Thus, a two-dimensional echocardiographic recording of an angled interventricular septum can be produced by positioning the transducer in a low intercostal space, and caution must be used in the interpretation of asymmetric septal hypertrophy on M-mode echocardiograms. Two-dimensional echocardiography is a useful means of identifying subjects with apparent asymmetric septal hypertrophy that often may be the result of a technical artifact.

Adolescent↗

Atrial systolic notch on the interventricular septal echogram: an echocardiographic sign of constrictive pericarditis.

Interventricular septal motion during ventricular diastole was analyzed using M-mode echocardiography in 13 patients with constrictive pericarditis and 12 patients with restrictive cardiomyopathy. In seven of eight patients with constrictive pericarditis in sinus rhythm, an abnormal "atrial systolic" notch was observed consisting of abrupt initial posterior motion toward the left ventricle approximately at the middle of the P wave and subsequent anterior motion at the end of the P wave and termination before the R wave. This notch was absent during atrial premature beats that were recorded in two patients. The atrial systolic notch was not observed in any patient with restrictive cardiomyopathy. The septal notch in early ventricular diastole previously described in constrictive pericarditis was seen in 62% of patients with constrictive pericarditis and 25% of patients with restrictive cardiomyopathy. Thus, an abnormal atrial systolic notch may be an additional useful sign to differentiate constrictive pericarditis from restrictive cardiomyopathy. The mechanism may be related to transient late diastolic pressure gradients between both ventricles resulting from asynchrony of left and right atrial contractions.

Diastole↗

Diagnosis of coronary stenosis by two-dimensional echographic study of dysfunction of ventricular segments during and immediately after pacing.

The adequacy of two-dimensional echocardiography during right atrial pacing for the detection and characterization of coronary artery stenosis was examined in 10 closed chest dogs. Pacing at successively higher rates up to 210 beats/min was carried out in the control state and again during a 70% left anterior descending coronary artery stenosis-induced with intracoronary plugs. Left ventricular short-axis echographic cross sections were obtained at several levels of the left ventricle. After computer-aided standardized subdivision, contractile function of the global section and its subsegments was characterized by computed systolic fractional area change percent and wall thickening percent. Ventricular segments supplied from the site of the 70% coronary stenosis were delineated in a low papillary level cross section by a myocardial contrast echographic technique, and these segments demonstrated significant dysfunction during pacing at 150 to 210 beats/min. Echographic observation of the involved segments immediately after pacing revealed a maximal depression of function 5 seconds after pacing, equivalent to dysfunction at peak pacing, with function returning to control levels within about 2 minutes. Both maximal pacing and early postpacing studies facilitated satisfactory discrimination of ischemic from normally perfused myocardial segments. These experiments show that right atrial pacing study with quantitative two-dimensional echocardiography may serve to detect and assess a coronary stenosis associated with minor or no cardiac dysfunction in the rest state.

Animals↗

Atypical echocardiographic and angiographic presentation of a postoperative pseudoaneurysm of the left ventricle after repair of a true aneurysm.

Subsequent to the repair of a true aneurysm from the posteromedial-basal aspect of the left ventricle, a 58 year old man developed a draining wound at the site of the sternotomy. Two-dimensional echocardiography revealed recurrence of the aneurysm at the site of the previous aneurysm repair. This aneurysm had a wide neck and looked similar in appearance to the previous true aneurysm. However, at surgery the patient was found to have a ventricular pseudoaneurysm with a cardiocutaneous fistula.

Cineangiography↗