[Ultrasound education by simulator training high acceptance by ultrasound trainees of all qualification levels].

Ultrasound education improves by simulator training, however, the acceptance of ultrasound simulator training has not been investigated. Therefore we evaluated the participants response to simulator education during an ultrasound course of abdominal emergencies at an international ultrasound congress, at a regular ultrasound course and during courses at a regional hospital and an university hospital. Altogether, 62.3% of the participants judged the simulator image quality to be good. 84.3% considered the case selection to be good and 92.7% of the participants viewed the educational benefit to be good. 98.5% whished to have further ultrasound simulator courses to be developed and 95.3% of the participants opted for the integration of simulator training into the conventional ultrasound education.

Attitude of Health Personnel↗

[Improvement of ultrasound education by simulator training].

Ultrasound education is complicated by varying quantities and qualities of specific pathologies resulting from distinct patient collectives. Furthermore, under current clinical conditions ultrasound educators as well as trainees frequently lack the time necessary for a sufficient ultrasound education. Finally, current ultrasound education materials including "gold standard" images are not ideally suited for teaching scanning three-dimensional pathologies. An improvement of ultrasound education is feasible by training ultrasound trainees on an ultrasound simulator we developed. By using this simulator as well in the classical beginner and advanced level courses as in focused courses of abdominal emergencies or general practice for instance, ultrasound trainees are able to practice scanning of numerous well defined pathologies under realistic conditions.

Abdomen↗

[Splenosis--important differential diagnosis in splenectomized patients presenting with abdominal masses of unknown origin].

A 40-year-old female patient was admitted for work-up of multiple abdominal masses. The lymphoma-mimicking tumors were detected accidentally during an ultrasound course. The past medical history was unremarkable besides a status post-traumatic splenic rupture and splenectomy. The patient was asymptomatic, especially there were no complaints of fever, night sweats or weight loss. Laboratory tests did not show pathological results. Ultrasound of the abdomen revealed multiple hypoechoic mesenterial and peritoneal enlarged tumors as well as a subhepatic mass (30 x 20 mm). Transmission computed tomography (CT) showed a normal chest, excluded abnormal thoracal masses and confirmed the multiple abdominal nodules. Microparticles were trapped only by tissue with phagocytosis function as cells of the reticulohistiocytary system in liver and spleen. Uptake of (99 m)Tc-labeled microparticles is specific for splenic tissue. All abdominal masses were detectable by single photon emission computed tomography (SPECT) after intravenous administration of this radiotracer. Ultrasound-guided biopsy proved the presence of spleen tissue with follicular hyperplasia. In conclusion, we report a case of post-traumatic splenosis. In 16 - 67 % of patients who experienced traumatic splenic rupture autotransplanted spleen tissue can be detected. Splenosis therefore is an important differential diagnosis of abdominal masses in splenectomized patients.

Abdomen↗

[New concepts in ultrasound education in gastroenterology by simulator training].

Ultrasound is one of the most important imaging methods in medicine. However, ultrasound education is complicated by varying quantities and qualities of specific pathologies resulting from distinct patient collectives. Furthermore, under current clinical conditions ultrasound educators as well as trainees frequently lack the time necessary for a sufficient ultrasound education. Finally, current ultrasound education materials including "gold standard" images are not ideally suited for teaching scanning three-dimensional pathologies. In a direct cross over study we recently proved, that the ultrasound simulator we developed simulated the real patient examination reliably and reproducibly. By using this simulator as well in the classical beginner and advanced level courses as in focused courses of abdominal emergencies for instance, ultrasound trainees are able to practice scanning of well defined pathologies under realistic conditions, which has not been possible before. Furthermore, the ultrasound simulator is well suited for a structured ultrasound training in single hospitals as well as in continuous medical education. Finally, objective, standardized ultrasound quality control has become possible with the simulator.

Computer Simulation↗

[Ultrasound of acute abdomen].

Ultrasound is an important tool in the diagnosis of acute abdominal pain, which is mainly caused by gastrointestinal diseases. This article gives an overview on the important differential diagnosis related to pain localization. Sonomorphological signs and their sensitivity and specificity are discussed. In contrast to other imaging methods ultrasound is hand guided. The present article differentiates the diagnostic capability of ultrasonic diagnosis depending on technical equipment and sonographer's educational level. These facts are important to stabilize the position of ultrasound in the ensemble of other imaging methods. The use of mobile ultrasound machines and an improved training (e.g. by computer assisted sonosimulator systems) will lead to an increasing importance of ultrasound.

Abdomen↗

Simulation of abdomen sonography. Evaluation of a new ultrasound simulator.

AIM: We developed and evaluated a simulator for the sonography of the abdomen in order to improve the teaching quality in sonography training. METHOD: Eleven medicine residents who had received 4 to 12 months full time sonography training performed ultrasound examinations of the right upper quadrant in 5 consecutive patients and in 5 simulator cases. The correctness of their findings and the time required for the examinations were measured. The subjective confidence in their findings and the handling of the ultrasound machines were rated on a visual analogue scale. RESULTS: During patient ultrasound examination 75 % (SEM 9%) of all pathologic findings were recognized by the residents, whereas 71 % (SEM 8%) of the pathologies of the simulator cases were found. This minimal difference was not significant in the paired, two sided t-test (p = 0.15). Severe pathologies did not escape detection. The time required for patient examination(10.57 min, SEM 3.25 min) was not significantly different (p = 0.53) to the time required for the simulator cases (9.59 min, SEM 2.98 min). The subjective confidence in the sonographic findings did not differ significantly (p = 0.39) between the real patient situation (68%, SEM 6%) and the simulation (64%, SEM 12 %). Only the handling of the ultrasound machines was judged to be significantly better (p=0.008) than the simulator (74%,SEM 7% vs. 61 %, SEM 12%). CONCLUSION: In this first direct crossover comparison between real patient sonography and simulator based scanning we proved that the simulator we developed simulates the real patient examination reliably and reproducibly.

Abdomen↗

[Combining stenting with the double wire technique effectively prevents side branch occlusion].

Coronary angioplasty involves a high occlusive risk for side branches originating just before, within or behind the dilated stenosis. We retrospectively investigated a new technique combining stenting of the main vessel with protection of the side branch with an inserted second wire, placed between the stent and the wall of the main vessel. From 86 patients undergoing this procedure in our hospital, the side branch remained open in 78 patients (91%). Eight patients initially had a relevant partial or complete occlusion of the protected side branch after stenting. In 5 of these patients, the occlusion could be re-opened at once by angioplasty. In the other 3, TIMI flow was 1 or 2 in the side branch. One of these patients developed an additional thrombotic occlusion of the main vessel (RCA) causing Q-wave infarction. In one other patient, the side branch occlusion caused a mild elevation of creatin kinase. In summary, combining the double wire technique with stenting is safe and effective to protect side branches during coronary angioplasty.

Angioplasty, Balloon, Coronary↗

Impact of nocturnal hypoglycemia on hypoglycemic cognitive dysfunction in type 1 diabetes.

To test the hypothesis that glycemic thresholds for cognitive dysfunction during hypoglycemia, like those for autonomic and symptomatic responses, shift to lower plasma glucose concentrations after recent antecedent hypoglycemia in patients with type 1 diabetes mellitus (T1DM), 15 patients were studied on two occasions. Cognitive functions were assessed during morning hyperinsulinemic stepped hypoglycemic clamps (85, 75, 65, 55, and 45 mg/dl steps) after, in random sequence, nocturnal (2330-0300) hypoglycemia (48 +/- 2 mg/dl) on one occasion and nocturnal euglycemia (109 +/- 1 mg/dl) on the other. Compared with nondiabetic control subjects (n = 12), patients with T1DM had absent glucagon (P = 0.0009) and reduced epinephrine (P = 0.0010), norepinephrine (P = 0.0001), and neurogenic symptom (P = 0.0480) responses to hypoglycemia; the epinephrine (P = 0.0460) and neurogenic symptom (P = 0.0480) responses were reduced further after nocturnal hypoglycemia. After nocturnal hypoglycemia, in contrast to nocturnal euglycemia, there was less deterioration of cognitive function overall (P = 0.0065) during hypoglycemia based on analysis of the sum of standardized scores (z-scores). There was relative preservation of measures of pattern recognition and memory (the delayed non-match to sample task, P = 0.0371) and of attention (the Stroop arrow-word task, P = 0.0395), but not of measures of information processing (the paced serial addition task) or declarative memory (the delayed paragraph recall task), after nocturnal hypoglycemia. Thus, glycemic thresholds for hypoglycemic cognitive dysfunction, like those for autonomic and symptomatic responses to hypoglycemia, shift to lower plasma glucose concentrations after recent antecedent hypoglycemia in patients with T1DM.

Adult↗

Impact of recent antecedent hypoglycemia on hypoglycemic cognitive dysfunction in nondiabetic humans.

To test the hypothesis that glycemic thresholds for hypoglycemic cognitive dysfunction, like those for neuroendocrine responses to and symptoms of hypoglycemia, shift to lower plasma glucose concentrations after recent antecedent hypoglycemia, 16 healthy young adult subjects (7 women and 9 men) were studied on two separate occasions in random sequence, once with hyperinsulinemic hypoglycemia (2.6 +/- 0.1 mmol/l, 47 +/- 1 mg/dl) and once with otherwise identical hyperinsulinemic euglycemia (4.8 +/- 0.1 mmol/l, 86 +/- 5 mg/dl) between 1430 and 1630. Neuroendocrine, symptomatic, and cognitive responses to hyperinsulinemic stepped hypoglycemic (4.7, 4.2, 3.6, 3.0, 2.8, 2.5, and 2.2 mmol/l; 85, 75, 65, 55, 50, 45, and 40 mg/dl) clamps were quantitated the following morning on both occasions. Cognitive function tests included measures of information processing (Serial Addition), attention (Stroop Arrow Word), pattern recognition and memory (Delayed Non-Match to Sample), and declarative memory (Paragraph Recall). As expected, plasma glucagon (P = 0.0094), epinephrine (P = 0.0063), and pancreatic polypeptide (P = 0.0046) responses to stepped hypoglycemia were reduced significantly, and symptomatic responses tended to be reduced after afternoon hypoglycemia. Performance on the cognitive function tests deteriorated (P < 0.0001) during stepped hypoglycemic clamps, but there were no significant overall effects of antecedent hypoglycemia on hypoglycemic cognitive dysfunction. Although deterioration was reduced (P < 0.05) from the 2.8 mmol/l (50 mg/dl) to the 2.5 mmol/l (45 mg/dl) steps on the Serial Addition and Delayed Non-Match to Sample tasks after afternoon hypoglycemia, comparable differences were not found on the Stroop Arrow Word or Paragraph Recall tasks. Thus, glycemic thresholds for hypoglycemic cognitive dysfunction, unlike those for neuroendocrine responses to and symptoms of hypoglycemia, do not seem to shift to substantially lower plasma glucose concentrations after recent antecedent hypoglycemia in nondiabetic humans.

Adolescent↗

Cognitive functioning in experimental hypoglycaemia assessed with event-related potentials.

Cognitive effects of experimentally induced hypoglycaemia were investigated by event-related brain potentials (ERPs) in auditory and visual classification tasks. In a cross-over design eight healthy male subjects (age 22-27 years) were studied under control conditions or following administration of 0.15 IU insulin kg-1. The ERPs showed preserved early cortical components, while the N2 component was greatly reduced in both modalities. P3 components did not show an influence of hypoglycemia. These results suggest that the cognitive deficits are due to an impairment of automatic feature extraction from the stimuli.