A novel method for producing x-ray test objects and phantoms.

A novel method for producing customized x-ray test objects and clinically realistic phantoms has been developed. Test objects can be created with a drawing software package and the digital images can be printed on a standard inkjet printer but using potassium iodide solution in place of the cartridge's ink. The reproducibility and the consistency, the limiting spatial resolution, the uniformity as well as the potassium iodide thickness per print have been evaluated. The relationship between the number of prints, grey levels and the radiation contrast was investigated and quantified. A copy of the Leeds TO10 contrast detail test object was printed and the x-ray images of the Leeds TO10 and of the printed Leeds TO10 were compared. In addition, the potential use of this method was demonstrated by reproducing a percutaneous transluminal coronary angioplasty clinical digital image. The reproducibility and consistency of this method was found to be better than 0.1%. The limiting spatial resolution of the printer using ink was found to be 3.55 1p mm(-1) but it deteriorated when the ink was replaced with potassium iodide and as the print density increases. The uniformity across the printed area was found to be satisfactory although an artefact due to the printer was present in the x-ray images. The comparison between the Leeds TO10 and the printed Leeds TO10 gave differences less than 10%. A good agreement between the clinical image and the printed clinical image was found. In conclusion, the method is a reliable, cost-effective, flexible and alternative way for producing x-ray test objects and clinically related phantoms.

Air↗

A study on radiation doses and irradiated areas in cerebral embolisation.

Patient radiation doses during interventional radiology procedures may reach the thresholds for radiation-induced skin and eye lens injuries. This study investigates the irradiated areas and doses received by patients undergoing cerebral embolisation, which is regarded as a high dose interventional radiology procedure. For each procedure the fluoroscopic and digital dose-area product (DAP), the fluoroscopic time, the total number of acquired images and entrance-skin dose (ESD) calculated by the angiographic unit were recorded. The ESD was measured by means of thermoluminescent dosimeters. In this study, the skin, eye and thyroid gland doses and the irradiated area for 30 patients were recorded. The average ESD was found to be 0.77 Gy for the posteroanterior plane and 0.78 Gy for the lateral plane. The average DAP was 48 Gy cm(2) for the posteroanterior plane and 58 Gy cm(2) for the lateral plane. The patient's average right eye dose was 60 mGy and the dose to the thyroid gland was 24 mGy. Seven patients received a dose above 1 Gy, one patient exceeded the threshold for transient erythema and one exceeded the threshold for temporary epilation. A good correlation between the DAP and the ESD for both planes has been found. The doctor's eye dose has also been measured for 17 procedures and the average dose per procedure was 0.13 mGy.

Embolization, Therapeutic↗