User introduced uncertainties in the measurement of field misalignment by a computer aided technique.

While images acquired using an electronic portal imager may be visually compared to other portal or simulator images to assess patient alignment, a more quantitative comparison is desirable. Computer aided alignment tools are available which are based on user placed landmarks. The purpose of this study was to estimate uncertainties introduced by the user to the final measurement of field misalignment using such a tool. Both intra- and inter-user reproducibility were assessed. To complete this task, a number of image pairs including both phantom and patient images were compared by multiple observers. Results of the comparisons (x- and y- translation and rotation) were tabulated for each image pair and their reproducibility assessed by calculating a mean and standard deviation. User introduced uncertainty was found to be independent of the magnitude of rotation or x- or y- translation. In all cases, there was no difference between intra-observer and inter-observer uncertainty. For clinical cases, there is a significant difference between uncertainty in x- and y-translation due to both image quality and patient anatomy. In addition, the magnitude of uncertainty tracks qualitatively with image quality and number of available anatomical landmarks. The decision to make a correction in field alignment must be made considering these uncertainty estimates. Image comparison must be fully automated to eliminate uncertainties introduced by the user.

Humans↗

Brachytherapy for recurrent single brain metastasis.

Of 112 stereotactic high-activity iodine-125 implants for malignant brain tumors done as of July 1, 1994, ten have been done for recurrent single brain metastasis and constitute the study group described herein. All patients had initially undergone craniotomy for tumor resection followed by fractionated external beam whole brain radiation and recurred at the same site in the brain. The interval between initial cancer therapy and occurrence of the brain metastasis was 13-156 weeks (median: 63 weeks). The interval between initial treatment of the brain metastasis and its recurrence treated with brachytherapy was 13-69 weeks (median: 35 weeks). Minimum brachytherapy dose administered was 70 Gy at a median dose rate of 67 cGy/hour. Eight patients have died. Two died suddenly at 2 and 13 weeks post-implant of presumed pulmonary embolus. Five died of recurrence of the brain metastasis at 20, 39, 52, 103, and 143 weeks post-implant, and one died of systemic metastases at 40 weeks post-implant. Two patients remain alive 183 and 324 weeks post-implant. High-activity iodine-125 brachytherapy appears to be of benefit for selected patients with recurrent single brain metastasis but larger, and preferably randomized studies are needed.

Adult↗

Brachytherapy for recurrent malignant astrocytoma.

PURPOSE: To assess the efficacy of interstitial brachytherapy in the treatment of patients with recurrent malignant astrocytoma. METHODS AND MATERIALS: Forty-six patients with recurrent malignant astrocytoma were treated with stereotactic high-activity temporary iodine-125 implants between September, 1986 and October, 1992. All patients had been initially treated for malignant astrocytoma (44) or low-grade astrocytoma (2) with surgery and external fractionated radiation. The median time between initial diagnosis and recurrence treated with brachytherapy was 12.5 months. Twenty-five patients received chemotherapy prior to brachytherapy. RESULTS: All but four patients have died; median survival time following brachytherapy is 46 weeks. Twelve patients underwent reoperation for radiation necrosis at a median interval of 6.5 months after treatment (26%). Five patients incurred complications directly due to brachytherapy (11%). Forty-four patients are evaluable regarding pattern of failure following brachytherapy. Six of these 44 patients (13.6%) recurred at a distance from the treatment volume (4 in brain and 2 in spinal subarachnoid space). CONCLUSION: Brachytherapy confers modest but meaningful prolongation of survival in selected patients with recurrent malignant astrocytoma, but complications are significant, reoperation frequently required, and recurrence outside the treatment volume common.

Adolescent↗

Description and evaluation of a new 3-D computerized treatment planning dose compensator system.

Evaluation has been performed of compensators generated by means of a computerized three-dimensional treatment planning system that can utilize either digitized slice profiles or CT scans. Two methods of calculating compensator thickness are used: the modified Batho power law (dSAR) method for digitized profiles and the equivalent TAR (eqTAR) method for CT scans. This system not only compensates for patient surface contours but also compensates for internal inhomogeneities. In addition, any required wedging will be incorporated in the compensator generation. This system has been tested for a number of extreme cases with inhomogeneities and sloping contours. Good agreement was obtained between the measured and computer calculated dose profiles especially along the central axis of the beam. A "Profile Uniformity Index" was defined to quantify the goodness of dose compensation in three dimensions. Compensation using this system can achieve good dose uniformity within the target volume in all clinical cases and is definitely an improvement over systems based solely on tissue deficit.

Algorithms↗

The dose distribution surrounding 192Ir and 137Cs seed sources.

Dose distributions in water have been measured using LiF thermoluminescent dosimeters for 192Ir seed sources with stainless steel and with platinum encapsulation to determine the effect of differing encapsulation. The dose distribution has also been measured for a 137Cs seed source. In addition, dose distributions surrounding these sources have been calculated using the EGS4 Monte Carlo code and have been compared to the measured data. The two methods are in good agreement for all three sources. Tables are given which describe the dose distribution surrounding each source as a function of distance and angle. In addition, specific dose constants have been determined from results of Monte Carlo simulation. This work has confirmed the utility of the EGS4 Monte Carlo code in modelling 192Ir and 137Cs seed sources to obtain brachytherapy dose distributions.

Brachytherapy↗

Effect of source encapsulation on the energy spectra of 192Ir and 137Cs seed sources.

The effect of source encapsulation on the energy spectra of 192Ir and 137Cs seed sources, both with stainless steel and with platinum encapsulation, was determined from results of Monte Carlo simulation. The fractional scatter dose around these sources has also been determined from Monte Carlo simulation. The platinum-encapsulated 192Ir source exhibited greater attenuation of the primary spectrum, as expected, and, consistent with this greater attenuation, exhibited more scattered radiation. Significantly less scatter was seen with the 137Cs source than with either 192Ir source, as is consistent with the higher-energy photons from 137Cs.

Brachytherapy↗

The use of Teflon-embedded calcium sulphate: dysprosium thermoluminescent dosimeters for chest radiography.

As part of a U.S. multi-regional pilot study conducted by the six Centers for Radiological Physics, 12-mm-diameter by 0.4-mm-thick CaSO4:Dy Teflon-embedded discs were evaluated and used to measure patient entrance exposure on 60 "average" patients at 12 clinical centers. The discs were found to have adequate sensitivity, reproducibility and linearity up to 69.7 microC kg-1 (270 mR). The minimum measurable exposure was estimated as 0.4 microC kg-1 (1.5 mR). All responses were corrected for energy dependence, which varied +/- 20% from 1.7 to 6.5 mm Al half-value layer. Patient entrance exposure values ranged from 1.3 to 28 microC kg-1 (5 to 110 mR), with a median value of 5.2 microC kg-1 (20 mR). This value agreed with exposure measurements made on the chest radiography equipment using an ionization chamber and a phantom which simulated an "average" patient, and with published Nationwide Evaluation of X-Ray Trends (NEXT) data for the same period.

Calcium Sulfate↗

The utilization of a multi-layer prosthesis to treat recurrent antral carcinoma: a case report and review of the literature.

This paper reviews the use of an intracavitary mold in the radiotherapeutic management of recurrent sub-orbital carcinoma of the maxillary sinus. An overview of the clinical features of antral carcinomas and the concept of brachytherapy in the management of these lesions is presented. Brachytherapy is usually reserved for relatively accessible lesions. Post-surgical and radiation-induced trismus can be a complicating factor, as in the case presented, where the inter-incisal distance was less than three millimeters. To circumvent the problem, a multi-layer antral plug was utilized as a carrier for the radioactive sources, and its construction is described.

Adult↗

Mailed thermoluminescent dosimetry reviews in radiation therapy.

The six Centers for Radiological Physics performed periodic thermoluminescent dosimetry (TLD) reviews for photon beams at 276 facilities across the country. The purpose of the reviews and the techniques in use are briefly described. Results from 2413 mailed reviews of megavoltage units indicate that, in 92% of the reviews, a specified dose was delivered within +/- 5% of the TLD-measured dose. A comparison is made to other mailed TLD review systems.

Postal Service↗

A comparison of the AAPM "Protocol for the determination of absorbed dose from high-energy photon and electron beams" with currently used protocols.

A comparison of the AAPM "Protocol for the determination of absorbed dose from high-energy photon and electron beams" (TG21) with currently used protocols for electron and photon dosimetry is presented. These protocols are the International Commission on Radiation Units and Measurements Report 21, "Radiation Dosimetry: Electrons with Initial Energies Between 1 and 50 MeV" (ICRU21), and the AAPM "Protocol for the Dosimetry of X- and Gamma Ray Beams with Maximum Energies Between 0.6 and 50 MeV" (SCRAD). Assuming a given radiation exposure and chamber parameters, doses to water at dmax for electron beams and at 5 g/cm2 for photon beams are calculated using the three protocols and then compared. The doses for photon beams calculated using the TG21 and SCRAD protocols are found to differ by 3% or less at energies below 10 MeV. The largest differences occur in photon doses at high energies where the dose calculated with the TG21 protocol is as much as 5.5% greater than that calculated with the SCRAD protocol for a typical thimble ionization chamber. For low electron beam energies, the doses calculated with the ICRU21 protocol are as much as 5% less than TG21 doses when using thimble chambers constructed of tissue-equivalent materials in a water phantom. If dosimetry measurements are performed in polystyrene, the dose calculated using TG21 may be greater than the ICRU21 dose, depending on chamber size and composition. An explanation for some of the differences between the protocols is presented emphasizing the dependence on chamber geometry, chamber composition, and phantom composition.

Electrons↗

Radial dose distribution of 192Ir and 137Cs seed sources.

The radial dose distributions in water around 192Ir seed sources with both platinum and stainless steel encapsulation have been measured using LiF thermoluminescent dosimeters (TLD) for distances of 1 to 12 cm along the perpendicular bisector of the source to determine the effect of source encapsulation. Similar measurements also have been made around a 137Cs seed source of comparable dimensions. The data were fit to a third order polynomial to obtain an empirical equation for the radial dose factor which then can be used in dosimetry. The coefficients of this equation for each of the three sources are given. The radial dose factor of the stainless steel encapsulated 192Ir and that of the platinum encapsulated 192Ir agree to within 2%. The radial dose distributions measured here for 192Ir with either type of encapsulation and for 137Cs are indistinguishable from those of other authors when considering uncertainties involved. For clinical dosimetry based on isotropic point or line source models, any of these equations may be used without significantly affecting accuracy.

Brachytherapy↗

Radial dose distribution from 192Ir seeds at distances far from the source.

Most current tissue attenuation and scattering factors for 192Ir are valid only to distances of 15 cm or less. Monte Carlo calculations using the EGS4 computer code were used to calculate tissue attenuation and scattering factors for 192Ir seed sources with both stainless steel encapsulation and with Pt encapsulation out to a distance of 32 cm from the sources. The data clearly show that polynomial tissue attenuation and scattering factors cannot be extrapolated beyond their range. Encapsulation specific factors are presented here that are valid at large distances from the source.

Brachytherapy↗

Characteristics of a spoiled 6-MV beam from a dual-energy linear accelerator.

A beam spoiler for a 6-MV x-ray beam was designed and spoiled beam dosimetry performed. The spoiled beam quality was similar to that of the unspoiled beam. The percentage depth doses at 5 mm were at least 90% for all field sizes except 4 x 4 cm, while the surface dose at 0 mm varied from 22.5% for a 4 x 4-cm field to 85.8% for a 22 x 22-cm field. The spoiled beam showed degraded beam flatness for small field size at superficial depths; the beam flatness at 6 mm for a 4 x 4-cm field was +/- 9.0%. The beam flatness improved as the field size increased, e.g., at same depth, the beam flatness was +/- 2.5% for a 22 x 22-cm field. The penumbra width (90%-10%) of the spoiled beam was greater than that of the unspoiled beam for all field sizes and at all depths; e.g., at 0-mm depth, for a 22 x 22-cm field, the penumbra width was 3.8 cm for the unspoiled beam and 7.2 cm for the spoiled beam. Beyond dmax the difference in the penumbra widths between the spoiled and unspoiled beam was about 3-4 mm for all field sizes and at all depths. The peripheral dose was larger for the spoiled beam.

Humans↗