Pulsed field sequencing gel electrophoresis.

The effect of pulsed fields on sequencing gel electrophoresis is investigated, using DNA fragment markers ranging in size from 20 to 6557 bases. For high continuous electric fields (5000 V/55 cm) band inversion is observed in which fragments larger than 4000 bases migrate faster than those of 800-1000 bases. The use of one-dimensional pulsed field gel electrophoresis (ODPFGE) eliminates band inversion and extends the monotonic size-mobility relationship of the DNA markers up to about 4000 bases. The relevance of these results, obtained using a manual sequencing process with autoradiographic detection, to automated sequences is discussed.

Autoanalysis

Observation of orientation and relaxation of protein-sodium dodecyl sulfate complexes during pulsed intermittent field polyacrylamide gel electrophoresis.

Polyacrylamide gel electrophoresis (PAGE) of proteins denatured with SDS (sodium dodecyl sulfate) has been used successfully to separate proteins according to their molecular mass. In spite of the extensive use of this technique, the motion of the protein-SDS complex in a polyacrylamide gel is still not understood. Here we report on the observation of the orientation (in the field direction) and relaxation of protein-SDS complexes during pulsed intermittent field PAGE experiments. The results give an indication of the stiffness of the molecules and may be useful for the development of a technique to improve the separation of large proteins using pulsed electric fields.

Chemical Phenomena

Molecular detrapping and band narrowing with high frequency modulation of pulsed field electrophoresis.

In high electric fields, megabase DNA fragments are found to be trapped, i.e. to enter or migrate in the gel only very slowly, if at all, leading to very broad electrophoretic bands and loss of separation. As a consequence, low electric fields are usually used to separate these molecules by pulsed field electrophoretic methods. We report here that high-frequency pulses eliminate the molecular trapping found in continuous fields. When high frequency pulses are used to modulate the longer pulses used in pulsed field electrophoresis, narrower bands result, and higher fields can be used. We suggest that this is due to effects that occur on the length scale of a single pore.

Candida

Construction of the physical map for three loci in chromosome band 13q14: comparison to the genetic map.

Pulsed-field gel electrophoresis (PFGE) and deletion mapping are being used to construct a physical map of the long arm of human chromosome 13. The present study reports a 2700-kilobase (kb) Not I long-range restriction map encompassing the 13q14-specific loci D13S10, D13S21, and D13S22, which are detected by the cloned DNA markers p7D2, pG24E2.4, and pG14E1.9, respectively. Analysis of a panel of seven cell lines that showed differential methylation at a Not I site between D13S10 and D13S21 proved physical linkage of the two loci to the same 875-kb Not I fragment. D13S22 mapped to a different Not I fragment, precluding the possibility that D13S22 is located between D13S10 and D13S21. PFGE analysis of Not I partial digests placed the 1850-kb Not I fragment containing D13S22 immediately adjacent to the 875-kb fragment containing the other two loci. The proximal rearrangement breakpoint in a cell line carrying a del13(q14.1q21.2) was detected by D13S21 but not by D13S10, demonstrating that D13S21 lies proximal to D13S10. Quantitative analysis of hybridization signals of the three DNA probes to DNA from the same cell line indicated that only D13S10 was deleted, establishing the order of these loci to be cen-D13S22-D13S21-D13S10-tel. Surprisingly, this order was estimated to be 35,000 times less likely than that favored by genetic linkage analysis.

Blotting, Southern

Manual sequencing using pulsed field.

The use of pulsed fields in manual sequencing opens up the compression zone found with a DC field and extends the range of resolution from a few hundred bases to several thousand bases. The band inversion problem is overcome with the proper pulsing conditions, and the bands are sharper than for the DC field case. Accurate visual reading is possible up to about 800-900 bases. The method is compatible with automation techniques, since the band spectrum is stretched continuously during migration, and the smaller fragments are run off the gel.

Base Sequence