PubMed Health⌕ Search

Biomedical subjects

C V Hanson

Publications and source records attributed to C V Hanson.

At least 19 recordsLinked to original sources

Characterization of the HIV-1 specific humoral immune response during highly active antiretroviral therapy (HAART).

Plasma samples from 19 patients were analyzed for HIV-1 directed humoral immune responses prior to and 1 year after initiation of HAART. Eight of the subjects were classified as virologic successes, defined by a >100-fold decrease in viral load (VL) over the 1-year study period and a final VL <500 copies/ml. The eleven HAART failures were defined as subjects with <10-fold decrease in VL. At study entry (before HAART), VL and CD4 counts were similar between the two groups. Humoral immune responses before therapy and after 1 year of therapy were measured by V3 peptide antibody binding titers and neutralization of HIV-1 MN and four subtype B clinical isolates. Before HAART, neutralizing antibody titers to the clinical isolates and HIV(MN), as well as HIV V3 envelope binding titers to several V3 peptides, were significantly higher among treatment successes compared with treatment failures. After 1 year on HAART, neutralization declined in titer and narrowed in specificity among the HAART successes. In contrast, a significant increase in both neutralizing titer and breadth was seen among HAART failures.

Adult↗

Psoralen photochemical inactivation of Orientia tsutsugamushi in platelet concentrates.

BACKGROUND: The risk of transfusion transmission of disease has been reduced by the combination of predonation questions and improved transfusion-transmitted disease assays, but the risk is still present. This study was conducted to determine if psoralen photochemistry could inactivate an obligate intracellular bacterium, with documented potential for transfusion, in PCs to further improve safety. STUDY DESIGN AND METHODS: PCs were inoculated with MNCs infected with Orientia tsutsugamushi. The concentrates were treated with amounts ranging from 0.86 to 138 micromol per L of 4'-(aminomethyl)-4,5',8-trimethylpsoralen hydrochloride (AMT) combined with a constant long-wave UVA light (320-400 nm) exposure of 5 J per cm(2). The effects of photochemical treatment were analyzed by using a mouse infectivity assay along with in vitro testing by PCR, indirect fluorescence antibody, direct fluorescence antibody, and Giemsa staining. RESULTS: AMT, at 0.86 micromol per L or more, combined with UVA light of 5 J per cm(2), inactivated O. tsutsugamushi that contaminated PCs. The PCs that did not receive the combined treatment caused infection. CONCLUSIONS: The psoralen AMT, in conjunction with UVA light exposure, effectively abolished the infectivity of PCs deliberately contaminated with the scrub typhus organism O. tsutsugamushi, as tested in a mouse infectivity assay.

Animals↗

Postexposure immunoprophylaxis of primary isolates by an antibody to HIV receptor complex.

mAb B4 is a monoclonal antibody directed against HIV receptor complex. The antibody had broad neutralizing activity against HIV and provided postexposure prophylaxis to hu-peripheral blood leukocyte (PBL)-severe combined immunodeficient mice and chimpanzees. B4 recognized a complex receptor site for HIV on the T cell surface that includes CD4 and also may be influenced by interaction with HIV coreceptors. mAb B4 preferentially neutralized primary HIV-1 isolates compared with T cell line-adapted strains, including syncytium-inducing and non-syncytium-inducing phenotypes, representatives from HIV-1 subtypes A-G, as well as HIV-2, simian immunodeficiency virus, and chimeric simian/human immunodeficiency virus (SHIV). Neutralization was demonstrated in both pre- and postinfection models. The administration of mAb B4 after infectious challenge totally interrupted the infection of hu-PBL-severe combined immunodeficient mice by PBL-grown HIV-1 and the infection of chimpanzees by chimp-adapted HIV-1. This mode of protection suggested that the anti-HIV receptor antibody is efficacious for prophylaxis after exposure to HIV and for prevention of maternal transmission and may be an effective antiretroviral agent for treatment.

Animals↗

Distribution of HIV type 1 (HIV-1) in blood components: detection and significance of high levels of HIV-1 associated with platelets.

BACKGROUND: Although inactivation of enveloped viruses transmitted by plasma derivatives has been successful, no methods for virus inactivation or removal have been established for platelet concentrates or red cell (RBC) components. Relatively little is known regarding the extent or significance of virus interactions with the cellular constituents in these components. STUDY DESIGN AND METHODS: Units of whole blood were collected from six HIV type 1 (HIV-1)-positive, asymptomatic individuals and separated into peripheral blood mononuclear cells (PBMNCs), cell-free plasma, white cell-reduced platelet concentrate, and white cell-reduced RBCs. DNA and RNA polymerase chain reaction and virus culture methods were used to study the compartmentalization of HIV-1 immediately after component preparation and after storage. RESULTS: As expected, HIV DNA and infectious virus were detected in fresh blood and in PBMNCs, and virion-associated RNA was detected in fresh plasma from all six donors. The levels of viral nucleic acids in these preparations remained relatively stable with 4 degrees C storage, whereas infectivity of PBMNCs was rapidly lost. Washed RBCs tested negative for HIV in all assays at all time points. Platelets retained high levels of HIV RNA (but not infectivity) after extensive washing, as well as after storage at 4 and 22 degrees C. High-level platelet-associated HIV-1 was also demonstrated in samples collected during early seroconversion. Periseroconversion and postseroconversion levels of platelet-associated HIV-1 correlated with the level of plasma viremia and with the rate of progression to AIDS. Cell-free virus from donor plasma and tissue culture fluid rapidly and firmly attached to platelets from noninfected donors. Infectivity of tissue culture virus bound to platelets was demonstrated in vitro. CONCLUSION: Significant levels of HIV-1 are associated with platelets during all stages of infection. Platelet-associated HIV could either mediate virus clearance or facilitate virus dissemination and expanded tropism. Finally, virus inactivation research must address virus associations with platelets.

Blood Platelets↗

Photochemical inactivation of viruses and bacteria in platelet concentrates by use of a novel psoralen and long-wavelength ultraviolet light.

BACKGROUND: A photochemical treatment process has been developed for the inactivation of viruses and bacteria in platelet concentrates. This process is based on the photochemical reaction of a novel psoralen, S-59, with nucleic acids upon illumination with long-wavelength ultraviolet light (UVA, 320-400 nm). STUDY DESIGN AND METHODS: High levels of pathogens were added to single-donor platelet concentrates containing 3 to 5 x 10(11) platelets in 300 mL of 35-percent autologous plasma and 65-percent platelet additive solution. After treatment with S-59 (150 microM) and UVA (0-3 J/cm2), the infectivity of each pathogen was measured with established biologic assays. In vitro platelet function after photochemical treatment was evaluated during 7 days of storage by using a panel of 14 assays. The in vivo recovery and life span of photochemically treated platelets were evaluated after 24 hours of storage in a primate transfusion model. RESULTS: The following levels of pathogen inactivation were achieved: >10(6.7) plaque-forming units (PFU) per mL of cell-free human immunodeficiency virus (HIV), >10(6.6) PFU per mL of cell-associated HIV, >10(6.8) infectious dose (ID50) per mL of duck hepatitis B virus (a model for hepatitis B virus), >10(6.5) PFU per mL of bovine viral diarrhea virus (a model for hepatitis C virus), >10(6.6) colony-forming units of Staphylococcus epidermidis, and >10(5.6) colony-forming units of Klebsiella pneumoniae. Expression of integrated HIV was inhibited by 0.1 microM S-59 and 1 J per cm2 of UVA. In vitro and in vivo platelet function were adequately maintained after antiviral and antibacterial treatment. CONCLUSION: Photochemical treatment of platelet concentrates offers the potential for reducing transfusion-related viral and bacterial diseases.

Animals↗

International clinical trials of HIV vaccines: I. Phase I trial of an HIV-1 synthetic peptide vaccine in Bangkok, Thailand.

A randomized, double blind, placebo controlled Phase I trial of a prototype human immunodeficiency virus type 1 (HIV-1) synthetic peptide vaccine was conducted in Bangkok, Thailand, to evaluate the safety and immunogenicity of the vaccine in a population of healthy adults at low risk for HIV infection, and to establish essential infrastructure for future HIV vaccine trials in Thailand. Thirty volunteers (25 males; 5 females) were recruited and randomized into 3 groups, receiving 3 intramuscular injections of either 100 micrograms vaccine (N = 12) or 500 micrograms vaccine (N = 12) or alum placebo (N = 6) on weeks 0, 4 and 25. The vaccine was well tolerated without any serious adverse effects. HIV-1 specific ELISA responses were detected in 20/24 subjects who received the vaccine, with V3 binding antibody titers ranging from 1:69 to 1:5,041. HIV-1 (MN) specific neutralizing antibody was detected in 19/20 of subjects with detectable HIV-1 specific binding antibody. Neutralization titers ranged from 1:14 to 1:1,294, which were less than titers observed in HIV-infected subjects. The results of this study indicate that the vaccine was well tolerated, and that the vaccine stimulated anti-HIV humoral immune responses in Thai subjects. The successful undertaking of this first HIV vaccine trial conducted in Thailand provided important preparatory information surrounding volunteer recruitment and motivations, and paves the way for future trials of HIV vaccines in Thailand.

AIDS Vaccines↗

International clinical trials of HIV vaccines: II. phase I trial of an HIV-1 synthetic peptide vaccine evaluating an accelerated immunization schedule in Yunnan, China.

A Phase 1, double-blind, placebo controlled trial was conducted in Longchuan County, China, to evaluate the safety and immunogenicity of a prototype HIV-1 synthetic peptide vaccine in a target population at risk for HIV infection, and to establish the infrastructure for future large-scale HIV vaccine efficacy trials. Subjects were randomly assigned to receive 100 microg or 500 microg of vaccine or alum placebo, and were given three injections at an accelerated 0, 1, and 2 month schedule. The vaccine was well tolerated with no significant local or systemic reactions observed in any subjects. Fifty-five percent (100 microg dose) and 64% (500 microg dose) of subjects who received the vaccine produced binding antibody to the immunogen as determined by ELISA. However, HIV-1 (MN) neutralizing antibody was detected in only 23% (3/13) of subjects with detectable HIV-1 specific binding antibody. It was concluded that this prototype HIV-1 synthetic peptide vaccine was well tolerated, safe and immunogenic, and that a 0, 1, 2 month schedule was not as effective in stimulating HIV-1 specific neutralizing antibodies compared with previous trials utilizing a 0, 1, 6 month schedule. Finally, this trial demonstrated that well-designed HIV vaccine trials can be performed at this clinical trials site in Yunnan, China, and that this site should be considered for conducting larger safety, immunogenicity and efficacy trials of candidate HIV vaccines.

AIDS Vaccines↗

A dose-ranging study of a prototype synthetic HIV-1MN V3 branched peptide vaccine. The National Institute of Allergy and Infectious Diseases AIDS Vaccine Evaluation Group.

A phase I double-blind trial was done to examine the safety and immunogenicity of a prototype synthetic human immunodeficiency virus type 1 MN strain (HIV-1MN) third variable region domain (V3) branched peptide vaccine in HIV-1-uninfected healthy adult volunteers. Subjects were randomly assigned to receive 20, 100, or 500 micrograms of vaccine or alum adjuvant control on days 0, 28, and 168. The vaccine was well-tolerated and appeared safe. Induction of binding antibody to V3 MN branched peptide was vaccine dose-related and was detectable in 9 of 10 subjects in the highest-vaccine-dose group. HIV-1MN-neutralizing antibody was detected after the third 500-micrograms dose in 8 of 10 subjects at the 90% neutralization end point. V3 MN peptide stimulated lymphocyte proliferation in 15 (75%) of 20 subjects after vaccination. In conclusion, this prototype vaccine was safe and it induced humoral and cell-mediated immune responses.

AIDS Vaccines↗

Human immunodeficiency virus in plasma and genital secretions during the menstrual cycle.

Six human immunodeficiency virus (HIV)-positive women were studied weekly over 8 weeks to detect HIV RNA in plasma and cervical secretions and proviral DNA in cervical, vaginal, and cervicovaginal lavage samples by polymerase chain reaction (PCR) amplification techniques. In cervical swab samples, cell-free HIV RNA was detected more frequently than cell-associated HIV proviral DNA (22/48 vs. 7/48, respectively). Cervical HIV RNA was consistently detected in 2 women with plasma HIV RNA > 100,000 copies/mL but was not detected in 2 women with plasma HIV RNA < 10,000 copies/mL, regardless of menstruation status. HIV-specific IgA was detected in the plasma of 2 women and in at least 1 cervicovaginal lavage sample from all 6 women. Thus, quantitation of cervical HIV RNA can be accomplished by PCR techniques and may be useful in evaluation genital viral shedding.

Adult↗

Comparison of four enzyme immunoassays for detection of human T-cell lymphotropic virus type 2 antibodies.

Four licensed enzyme immunoassay (EIA) kits for the measurement of antibody to human T-cell lymphotropic virus (HTLV) type 1, one from Organon Teknika Corp. (OTC), one from Cambridge Biotech Corp. (CBC), and two from Abbott Laboratories (the 1993 modification [Abb 93] and the 2.0 version licensed in 1995 [Abb 95]), were evaluated for sensitivity and specificity in the detection of HTLV type 2 antibody, and the results were compared with those previously obtained with earlier kit versions. The CBC, Abb 95, Abb 93, and OTC kits had sensitivities of 99.7, 97.6, 96.8, and 96.2%, respectively, compared with sensitivities of 89.1 and 60% for the Abbott and CBC (previously DuPont) kits, respectively, licensed in 1988. Thus, the abilities of commercial kits to detect HTLV antibody have improved. The relative specificities of the CBC, Abb 95, Abb 93, and OTC kits with negative blood donor specimens that had been reactive with the 1988 CBC EIA kit were 92.9, 64.5, 78.8, and 62.6%, respectively. Compared with those of the 1988 versions, the specificity of the Abbott EIA has decreased and the specificity of the CBC kit has been significantly improved.

Blood Donors↗

Neutralization of primary HIV-1 isolates by anti-envelope monoclonal antibodies.

OBJECTIVE: To evaluate human monoclonal antibodies (MAb) for neutralizing activity against primary HIV-1 isolates in peripheral blood mononuclear cells. DESIGN: Neutralization activity data were obtained from 11 laboratories on a coded panel consisting of six human MAb to HIV envelope V3, CD4-binding region or gp41. Hyperimmune globulin against HIV-1 and normal human immunoglobulin G were supplied as controls. Each laboratory received pre-titered virus for use in the studies. METHODS: Each laboratory measured neutralization of the MAb against laboratory strain HIVMN, genomic clone HIVJR-CSF, two subtype B and one subtype D primary isolates. RESULTS: The titers of the centrally supplied virus stocks as determined by re-titration or back-titration varied among laboratories and were generally 10-100-fold less than provided. The neutralizing activity of each MAb varied by as much as a 1000-fold among laboratories. These differences may result from varying sensitivity in neutralization assay protocols and the differing susceptibility of primary cells to infection with HIV-1. CONCLUSIONS: To consolidate the data from multiple laboratories, the neutralization titers were compared by classifying antibodies as neutralizing if the antibody concentration for 50% virus inhibition was < or = 10 micrograms/ml. By this criterion, the CD4-binding region and gp41 MAb neutralized all four subtype B viruses and the subtype D isolate in a few of the laboratories. The V3 MAb neutralized only HIVMN and the closely related HIVJR-CSF viruses.

Antibodies, Monoclonal↗

Photochemical inactivation of pathogenic bacteria in human platelet concentrates.

Platelet concentrates (PC) may be infrequently contaminated with low levels of bacteria that can cause septicemia and death in patients receiving transfusion therapy. We evaluated the efficacy of a photochemical decontamination (PCD) technique using 8-methoxypsoralen (8-MOP) and long wavelength UV light (UVA) to inactivate bacteria in standard therapeutic PC. Twelve phylogenetically distinct pathogenic bacteria, 5 gram-positive and 7 gram-negative organisms, were seeded into PC to a final challenge dose ranging from 10(5) to 10(7) colony-forming units (CFU)/mL. Contaminated PC were treated with 8-MOP (5 micrograms/mL) and 5 J/cm2 of UVA, a PCD treatment regimen found to adequately preserve in vitro platelet function. Greater than 10(5) CFU/mL of all 5 gram-positive (Staphylococcus aureus, Streptococcus epidermidis, Streptococcus pyogenes, Listeria monocytogenes, and Corynebacterium minutissimum) and 2 of the gram-negative (Escherichia coli and Yersinia enterocolitica) organisms were inactivated. The remaining 5 gram-negative organisms were more resistant, with less than 10(1) to 10(3.7) CFU/mL inactivated under these conditions. The inactivation efficiency for this resistant group of gram-negative organisms was improved when PC were resuspended in a synthetic storage medium with reduced plasma protein concentration (15%) and an increased 8-MOP concentration (23.4 micrograms/mL). Illumination with 3 J/cm2 of UVA in this system inactivated greater than 10(5) CFU/mL of 4 resistant gram-negative organisms (Salmonella choleraesuis, Enterobacter cloacae, Serratia marcescens, and Klebsiella pneumoniae) and 10(4.1) CFU/mL of the most resistant gram-negative organism (Pseudomonas aeruginosa). This level of PCD treatment did not adversely affect in vitro platelet function. These results demonstrate that PCD using 8-MOP (5 to 23.4 micrograms/mL) effectively inactivated high levels of pathogenic bacteria in PC with adequate preservation of in vitro platelet properties.

Adult↗

Loss of red blood cell viability associated with limited thermal inactivation of extracellular HIV-1.

The effects of incubation at mildly elevated temperatures on HIV-1 inactivation and in vitro red blood cell properties were investigated. Red cells (55% Hct) were leukodepleted (3 log10) by filtration, maintained at 45 or 47 degrees C for 4 or 8 h, and then stored at 4 degrees C. Hemolysis was twice that of controls after 42-day storage for samples treated for 4 h at 45 degrees C, and five times larger for samples heated at 47 degrees C. There was also a significant increase in the rate of potassium loss, an early decrease in ATP levels, and an initial drop in pH for samples treated at either temperature. Larger differences were observed for samples exposed to these elevated temperatures for 8 h. Osmotic deformability curves obtained by ektacytometry showed dramatic decreases in red cell deformability at both temperatures and for both time periods. HIV-1 inactivation in red cells treated at 45 degrees C (approximately 0.25 log10/h) was considerably less than that obtained in tissue culture medium (1-2 log10/h). Since the decrease in red cell deformability is likely to indicate reduced red cell function and survival, and the rate of HIV-1 inactivation is low, mild heat treatment is not an adequate process for viral inactivation of red cell products.

Blood↗

Sensitivities of radioimmunoprecipitation assay and PCR for detection of human T-lymphotropic type II infection.

Five hundred forty-eight uncoagulated blood specimens from intravenous drug users infected with human T-lymphotropic virus type II (HTLV-II) were used to evaluate the sensitivities of the radioimmunoprecipitation assay (RIPA) and PCR for detecting HTLV-II-infected people. The sensitivities of both RIPA and PCR were found to be dependent on the HTLV-II antibody titer, as determined by the immunofluorescence assay. Neither of these recommended confirmatory methods was as sensitive for detecting weakly reactive HTLV-II specimens as the immunofluorescence assay, Western blotting (immunoblotting), or a modified licensed enzyme immunoassay. Use of RIPA and PCR to determine the reliabilities of other tests may sometimes give erroneous results.

DNA, Viral↗

Evaluation of two commercial human T-cell lymphotropic virus western blot (immunoblot) kits with problem specimens.

We evaluated two commercial human T-cell lymphotropic virus (HTLV) Western blot (WB; immunoblot) kits, Cambridge Biotech Corp. (CBC) and Diagnostic Biotechnology Ltd. (DBL). Both methods employ HTLV type I (HTLV-I) viral lysate and rgp21. The DBL WB kit also distinguishes between HTLV-I and HTLV-II antibodies, using an HTLV-I-specific and an HTLV-II-specific recombinant. Fifty weakly reactive HTLV-II-positive plasma specimens which were falsely negative with the Abbott enzyme immunoassay (EIA) and 50 Ortho EIA false-positive samples were selected to determine sensitivity and specificity. The sensitivities of the CBC and the DBL WB kits were 90 and 68%, respectively. All positive samples reacted with rgp21 in both kits, but some did not display core bands. Five samples were typed as HTLV-I and four were typed as dual infection by the DBL WB kit. The specificities of the CBC and DBL kits were 48 and 70%, respectively. The most prevalent WB reaction with the negative samples was with the core protein, p19, followed by p24 and p28 for CBC and rgp21 and p28 for DBL. DBL had two false-positive interpretations, and CBC had none, rgp21 was the most sensitive antigen in both kits for the weakly reactive HTLV-II samples. If all samples not reacting with this protein were interpreted as WB negative, regardless of other bands, the specificity would improve to 90% for CBC and 86% for DBL.

Blotting, Western↗