Supraventricular arrhythmia before and after surgical closure of atrial septal defects: spectrum, prognosis and management.

UNLABELLED: Supraventricular arrhythmias are often observed in patients before and after atrial septal defect repair. Although several papers report different incidences of sustained supraventricular arrhythmias, postoperative 'incisional' macroreentrant tachycardias have not been systematically investigated. METHODS: We reviewed 136 consecutive patients (79 female, 57 male, mean age 36.8+/-17.8 years) who underwent atrial septal defect repair at our institutions between January 1990 and January 1999. Coexisting valve disease requiring surgical intervention was noted in 13 patients (9.5%). The mean follow-up period was 78.8+/-30.1 months. RESULTS: Sustained supraventricular arrhythmias occurred in 12 patients (8.8%) before surgery (atrial fibrillation in 11 patients). Using multivariate analysis the occurrence of arrhythmia significantly correlated with the presence of coexisting heart disease (P< 0.001) and age at surgery (P=0.011) After surgery sustained supraventricular arrhythmias were recorded in 16 patients (11.7%). Eleven of them had atrial fibrillation, permanent in 8 cases, 4 'incisional' macroreentrant atrial tachycardia and 1 atrioventricular re-entry tachycardia. There was a significant correlation between pre and postoperative arrhythmia (P< 0.001). Two of the 4 patients with macroreentrant atrial tachycardia underwent successful radiofrequency catheter ablation, whereas the arrhythmia was controlled medically in the remaining 2 patients. CONCLUSIONS: Atrial fibrillation remains the most frequent form of arrhythmia before and after surgical closure of atrial septal defects in adulthood, and relates to age at the time of repair and coexisting heart disease. Incisional macroreentrant atrial tachycardia is an identifiable, albeit less common, form of tachycardia, which can be treated by transcatheter ablation.

Adolescent↗

Modified button-Bentall operation for aortic root replacement: the miniskirt technique.

BACKGROUND: The aim of this study was to evaluate the midterm results of a modified button-Bentall operation (modified-bB) specifically designed to incorporate any type of prosthetic valve in composite conduit aortic root replacement. METHODS: Between 1991 and 2000, a total of 135 patients underwent modified-bB for annuloaortic ectasia (74 patients), type A dissection (31), or aortic aneurysm without dissection (30). Of these, 34 were emergencies (25.2%). A total of 50 bioprostheses (study group 1) and 85 bileaflet mechanical prostheses (study group 2) were implanted. Group 1 mean age was 66.9 +/- 7.4 years versus 51.5 +/- 12.1 years in group 2 (p < 0.001). Composite-conduit creation occurred during proximal suture line construction as a single-step maneuver. Interrupted extracardiac polyester mattress sutures sequentially entered the aortic annulus, the prosthetic valve ring, and the vascular graft 7 mm from its free edge (miniskirt). Running monofilament suture line secured proximal hemostasis, buttressing aortic remnants and graft edge. Coronary reimplantation was accomplished in all cases by the button technique. Concomitant procedures were performed in 51 patients (37.8%). RESULTS: The 30-day mortality was 5.18% (7/135 patients). Eight patients (5.9%) required revision for proximal (1 patient), coronary button (3), or distal (4) anastomosis leakage. Three patients (2.2%) perioperatively developed nonfatal inferior myocardial infarction. Kaplan-Meier 9-year survival is 91.8% +/- 0.026 SE with 88.1% (95% confidence limits 71.7% to 95.5%) reoperation freedom. According to the Cox proportional hazard method, stratification of the risk for death according to prosthesis type indicates previous operation (p = 0.001) and emergency (p = 0.0465) as independent predictors of hospital mortality. Associated procedures to modified-bB increased risk of reoperation (p = 0.031). CONCLUSIONS: Modified-bB was associated with low mortality, excellent midterm survival, and freedom from reoperation. Absence of valve-to-graft tapering, reduced coronary button anastomosis tension, and prosthesis selection according to patient profile, are apparent advantages of modified-bB.

Actuarial Analysis↗

Artificial chordae in the treatment of anterior mitral leaflet pathology.

This report describes the authors' clinical experience with expanded polytetrafluorethylene (e-PTFE) sutures to replace the anterior mitral leaflet chordae for valve repair. Between November 1986 and July 1995, 203 patients underwent operations with e-PTFE chordae insertion. Among these, 122 had artificial chordae utilized for anterior mitral leaflet repair. Four patients had the valve replaced during the same operation because of an unsatisfactory result. One patient died from respiratory insufficiency 16 days after operation. Transoesophageal echocardiography at discharge from hospital showed no evidence of regurgitation in 81 cases, and trivial regurgitation in 36. During a mean follow-up of 36.6 (range 1-106) months two other patients died from causes unrelated to the valve repair, while one patient had a transient ischaemic attack returning to sinus rhythm. Two patients were reoperated on 12 and 18 months respectively after their initial operation for progression of valvular degeneration causing natural chordae rupture. Among the remaining 113 patients, 111 are in New York Heart Association functional class I and yearly transoesophageal echocardiography has shown absent or trivial regurgitation. The utilization of e-PTFE as artificial chordae for anterior mitral leaflet pathology is a safe and reliable procedure, yielding excellent results and increasing the number of candidates for valve repair.

Adolescent↗

Usefulness of transthoracic and transoesophageal echocardiography in recognition and management of cardiovascular injuries after blunt chest trauma.

OBJECTIVE: To assess the diagnostic potential of transthoracic and transoesophageal echocardiography for the detection of traumatic cardiovascular injuries in patients suffering from severe blunt chest trauma. DESIGN: Prospective study over a three year period. SETTING: A regional cardiothoracic centre. PATIENTS: 134 consecutive patients (94 M/40 F; mean age 38 (SD 14) years) suffering from severe blunt chest trauma (injury severity score 33.5 (18.2)). Most patients (89%) were victims of motor vehicle accidents. EVALUATION: All patients underwent transthoracic and transoesophageal echocardiography within 8 h of admission. Aortography was performed in the first 20 patients and in a further five equivocal cases. RESULTS: Transthoracic echocardiography provided suboptimal images in 83 patients, detecting three aortic ruptures, 28 pericardial effusions (one cardiac tamponade), 35 left pleural effusions, and 15 myocardial contusions. Transoesophageal echocardiography was feasible in 131 patients and detected 14 aortic ruptures (13 at the isthmus), 40 pericardial effusions, 51 left pleural effusions, 34 periaortic haematomas, 45 myocardial contusions, right atrial laceration in one patient with cardiac tamponade, one tricuspid valve rupture, and one severe mitral regurgitation caused by annular disruption. For the detection of aortic rupture transoesophageal echocardiography showed 93% sensitivity, 98% specificity, and 98% accuracy. Time to surgery was significantly shorter (30 (12) v 71 (21) min; P < 0.05) for patients operated on only on the basis of transoesophageal echocardiographic findings. CONCLUSIONS: Transthoracic echocardiography has low diagnostic yield in severe blunt chest trauma, while transoesophageal echocardiography provides accurate diagnosis in a short time at the bedside, is inexpensive, minimally invasive, and does not interfere with other diagnostic or therapeutic procedures.

Accidents, Traffic↗

Hemodynamic evaluation of 23 mm Pericarbon and 23 mm Hancock II bioprostheses in the aortic position at mid-term follow up.

BACKGROUND AND AIMS OF THE STUDY: Pericardial xenografts were introduced for clinical use following evidence of their good hemodynamic characteristics in laboratory tests; however, their efficiency in comparison with porcine valves has not been fully assessed. Pericarbon, a new type of pericardial bioprosthesis, has been recently developed in order to provide better hemodynamic performances and longer durability than such bioprostheses currently in use. METHODS: Fifteen patients operated on for aortic valve replacement with a 23 mm Pericarbon and a sex- and age-matched group operated on with a 23 mm Hancock II bioprosthesis were submitted to echocardiographic and Doppler examinations in order to compare the hemodynamic performance of the two devices. RESULTS: Peak transvalvular gradients for Pericarbon and Hancock II bioprostheses (38.9 +/- 13.0 vs. 33.9 +/- 13.0 mmHg; p = 0.294) and mean transvalvular gradients (24.7 +/- 7.6 vs. 20.8 +/- 9.9 mmHg, p = 0.24) showed no significant difference. However, the indexed effective prosthetic dynamic area was significantly larger for the Hancock II device (0.73 +/- 0.14 vs. 0.62 +/- 0.13 cm2; p < 0.05). CONCLUSIONS: When installed as 23 mm pericardial bioprostheses, the Pericarbon device appears not to demonstrate superior hemodynamic performance to that of the Hancock II; however, additional studies are needed to provide a definitive conclusion.

Aged↗

The pericardium reinforced suture annuloplasty: another tool available for mitral annulus repair?

From May 1985 to May 1992, 169 patients underwent surgery for mitral valve repair. In 87% of these patients, the valve reconstruction involved the mitral annulus. At the beginning, in an effort to preserve systolic movement of the annulus and avoid the implant of prosthetic materials inside the heart, we mainly used simple suture annuloplasty in 66 patients. When we reoperated upon three patients only a few months after reconstruction of the mitral valve for a dehiscence of the suture annuloplasty, we decided to perform ring annuloplasty with the Carpentier ring in 23 patients. Though we have not seen any problems with the Carpentier ring in our series, we performed a suture annuloplasty reinforced with a strip of autologous pericardium to eliminate all prosthetic material. Since introducing this technique in 1989, we have used this annuloplasty in 58 patients. We have not observed any dehiscence of the suture or other complications related to this procedure. Three patients with a pericardial annuloplasty underwent reoperation for other reasons; the autologous pericardium was perfectly attached to the annulus, covered by a smooth layer of fibrous tissue without calcification. After this encouraging initial experience, we believe that long-term follow-up is necessary to confirm that autologous pericardium is an effective method of mitral annulus repair.

Heart Valve Diseases↗

The Meadox-Gabbay pericardial xenograft: failure of the unicusp principle.

Durability of a new bioprosthesis, the Meadox-Gabbay unileaflet pericardial xenograft, was evaluated by reviewing a series of 12 patients who received this device in the mitral position from 1983 to 1985. Bioprosthetic failure necessitated reoperation in 5 patients 21, 22, 53, 66, and 81 months after placement. Three patients died of cardiac failure after 31, 52, and 70 months; no postmortem examinations were done. In 2 of the 3 patients, an echocardiographic study had shown signs of valvular dysfunction. Pathological examination of five available explants revealed the presence of redundancy and stretching of the single pericardial leaflet in all of them; in one, this lesion alone caused severe prosthetic incompetence. Other pathological findings included cusp and commissural calcification and commissural tears with or without calcification. Histologic examination and electron microscopy showed intrinsic calcification involving both collagen bundles and cellular debris and various degrees of collagen disruption. In this limited series of patients, the Meadox-Gabbay pericardial xenograft demonstrated various modes of failure that markedly impair its durability and render it unsuitable as a cardiac valve substitute.

Adult↗

Surgical technique for artificial mitral chordae implantation.

Failure of reconstructive procedures of the mitral valve is often ascribed to diffuse alteration of the subvalvular apparatus, which prevents the utilization of well-established techniques such as chordal transposition or shortening. For this reason, in 1986 after 2 years of animal experiments, we started the clinical use of expanded-polytetrafluoroethylene mitral chordae. Details of the surgical procedure are presented. Our experience is based on 51 patients with a mean follow-up of about 20 months (range 3-57). Four patients had the valve replaced during the same operation: one patient died later of cardiac failure and two underwent reoperation, 8 and 18 months after operation. Forty-one patients are in New York Heart Association Functional Class I and three in Class II. We suggest this technique in association with other traditional procedures to increase the number of mitral valves repaired, mostly because of degenerative etiology.

Adult↗

Psychosocial outcome one year after heart surgery. A prospective study.

Ninety-nine of 118 patients receiving cardiac valve replacements (n = 55) or coronary artery bypass grafts (n = 44) were studied before surgery and again one year after surgery. Psychological, social, and physical variables were assessed. For the 19 subjects not returning for follow-up, medical data collected by their general practitioner were available. The physical results of surgery were good, with over 90% of the patients showing improvement. Mean scores for psychological distress and quality of life improved; however, a bad psychosocial adjustment was present in about 25% of patients at follow-up. Bad psychosocial adjustment was not correlated with surgical results. The preoperative variables most predictive of poor psychosocial outcome were high scores in the general hypochondriasis and irritability subscales of the illness Behaviour Questionnaire, bad psychological adjustment characterized by high anxiety, depression, and global scores on the Symptom Distress Checklist, and ischemic rather than valvular heart disease.

Adult↗

[Prevalence of atherosclerotic lesions of the carotid bifurcation found with echo-doppler (duplex) technic in patient candidates for aortocoronary bypass].

The association of an overt coronary artery disease with a cerebrovascular disease is frequently reported. However the real prevalence of atherosclerotic lesions at the carotid bifurcation in coronary patients is not well established. The aim of our study was to evaluate the prevalence of atherosclerotic involvement of the extracranial carotid arteries in a group of 141 patients undergoing coronary artery by-pass graft (CABG) and to verify whether any correlations between coronary and carotid artery disease exist. The extracranial carotid arteries have been studied by means of an echo-doppler (duplex) system, which combines a B-mode images with a pulsed doppler. A high prevalence (17.02%) of patients with a severe (greater than 50% diameter reduction) carotid involvement was detected (Tab. II). However, no correlations between the coronary and the carotid disease were found in terms of extension and severity (Tab. V). In conclusion, a systematic evaluation of the carotid arteries is recommendable in the coronary patients, candidates to CABG, even in the absence of cerebrovascular symptoms.

Adult↗

Calcific degeneration as the main cause of porcine bioprosthetic valve failure.

Sixty-seven glutaraldehyde-processed porcine bioprostheses (PBs), recovered at autopsy or reoperation from 65 patients, were evaluated by roentgenologic and pathologic examination. Seven patients with 8 PBs were younger than 20 years of age. The time interval of function was 2 to 138 months (average 62). Pathologically, 53 explants had signs of intrinsic dysfunction, which was ascribed to calcification in 36 (68%). By x-ray examination, calcific deposits were found in 55 of 67 PBs (82%). The mean duration of function was 70 +/- 32 months in calcified PBs vs 27 +/- 18 months in noncalcified PBs (p less than 0.001). All 26 PBs that had been in place for longer than 6 years were calcified. In 45 PBs the Ca++ deposits were considered severe (mean time of function 76 +/- 32 months) and mild in 10 (mean time of function 44 +/- 22 months) (p less than 0.005). The Ca++ deposits were located at the commissures in 54 PBs (98%), at the body of cusps in 41 (75%), at the free margin in 37 (67%) and at the aortic wall in 37 (67%). When mild, Ca++ deposits involved the commissures in 90% of cases, the body of cusps in 30% and the free margin only in 10%. Forty-seven calcified PBs were mounted on a flexible stent, and 8 had a rigid stent, with an average time of function of 63 +/- 28 and 113 +/- 18 months, respectively (p less than 0.00001). Ca++ dysfunction occurred earlier in the aortic than in the mitral position (59 +/- 19 vs 86 +/- 35 months, p less than 0.05). All the PBs explanted from young patients and 47 of 59 PBs removed from adult patients were calcified, with an average time of function of 50 +/- 21 vs 73 +/- 33 months, respectively (p less than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

The use of an autogenous vaccine in the treatment of sternal wound infections following open heart procedures: a preliminary report.

Five patients, who developed sternal wound infection following open heart surgery and in whom the standard methods of management of this complication had been unsuccessful, were treated with an autogenous vaccine. Complete healing of the sternal wound was obtained in 4 of them, while in one, who had an associated mediastinitis, a slow recovery with persistence of a sternal fistula occurred. The results of this preliminary experience indicate that the use of an autogenous vaccine might be regarded as an alternative method of treatment of sternal infections in selected patients.

Adult↗