PubMed Health⌕ Search

Biomedical subjects

C Vettier

Publications and source records attributed to C Vettier.

At least 19 recordsLinked to original sources

Resonant enhancements at nonmagnetic ions: new possibilities for magnetic X-ray scattering.

Synchrotron experiments with uranium antiferromagnetic compounds have discovered large ( >1000) enhancements of the magnetic scattering intensities at the K edges of nominally nonmagnetic anions, e.g., Ga and As. The width in energy, the position with respect to the white line, and the azimuthal and polarization dependencies permit one to associate the signal with transitions of E1 dipole symmetry from 1s to 4p states. In momentum space, the signal exhibits long-range order at the antiferromagnetic wave vector. We discuss possible channels capable of generating the observed enhancements.

Journal Article↗

Mycobacterium kansasii septic arthritis: French retrospective study of 5 years and review.

Septic arthritis due to Mycobacterium kansasii is rare; only 40 cases have been published. A French national inquiry revealed the occurrence of 10 new cases between 1992 and 1997 (8 men and 2 women: mean age, 37 years; range, 25-54 years). Seven had an underlying condition: AIDS (n=4), chronic skin psoriasis and AIDS (n=2), or a renal transplant (n=1). Trauma to the joint, use of intra-articular corticosteroid(s) 1 month to 2 years after the event, and chronic skin psoriasis were risk factors. The mean interval between appearance of the first symptoms of arthritis and the diagnosis was 5 months. Monarthritis was localized to the knee (n=4), wrist (n=3), finger (n=1), elbow (n=1), or ankle (n=1). The main diagnostic procedure was culture of a synovial biopsy specimen. In all cases, debridement was associated with antimycobacterial treatment. Three patients died of AIDS during treatment, and another is still undergoing treatment; the other 6 patients were cured. M. kansasii infection should be considered in all cases of indolent arthritis with any of the following risk factors: local trauma, local or systemic corticosteroid therapy, chronic skin psoriasis, and immunodepression, especially that due to human immunodeficiency virus infection.

Adolescent↗

Polarization analysis in the 3-25 keV range at the ESRF magnetic scattering beamline.

The ESRF magnetic scattering beamline has been optimized for easy tunability of the polarization and energy in the 3-40 keV range. The linear horizontal polarization from the undulator reaches 99.9%, with a flux of approximately 10(12) photons s(-1) at the sample. The diffractometer can operate in horizontal and vertical geometries, with an energy or polarization analyser. The capabilities of this beamline in terms of flux, energy tunability and polarization, permitted polarization analysis of resonant magnetic scattering from antiferromagnetic UPd(2)Si(2) at both the L(2)- and M(4)-edges of uranium, to separate the contributions of the 5f and 6d electrons to the magnetism.

Journal Article↗

Design of an X-ray Phase-Plate Analyzer to Measure the Circular Polarization Rate of a Helical Undulator Source.

A quarter-wave plate made of a ca 16 mum-thick silicon single-crystal was used at energies as low as 2.8 keV to convert circularly polarized photons into linearly polarized photons. Coupled to a linear polarimeter, this quarter-wave plate enabled the characterization of the circular polarization rate of the radiation emitted by one of the ESRF helical undulators, Helios-I. The measured value (ca 97%) is in good agreement with theoretical predictions. Special attention was paid to the alignment procedures of all relevant optical components of the beamline.

Journal Article↗