PubMed Health⌕ Search

Biomedical subjects

C Vittori

Publications and source records attributed to C Vittori.

15 recordsLinked to original sources

A multisite physician's office laboratory evaluation of an immunological method for the measurement of HbA1c.

OBJECTIVE: To evaluate the clinical performance of a new immunological HbA1c method in physicians' office laboratories. RESEARCH DESIGN AND METHODS: Three physicians' offices participated in the evaluations. The clinicians routinely use HbA1c test results to monitor their patients' long-term blood glucose control. Precision and interlaboratory variability were assessed using three levels of lyophilized controls. Correlation of the method's results to currently available laboratory methods was made. Comparison of finger-stick (capillary) results to venous EDTA whole blood results was made on 134 patients. Physician and laboratory personnel input was evaluated with regard to the clinical utility of the system. RESULTS: The CVW and CVB were a maximum of 4.5 and 4.4% for the immunoassay system on three levels of control materials at the three sites. Interlaboratory variability among the control means was found to be 4.9-5.4, 8.0-8.3, and 11.7-12.0% HbA1c. Correlation coefficients (r) ranged from 0.95 to 0.99. There was a positive bias by the DCA 2000 compared with the in-house method at site 1. Minimal negative biases were seen by the DCA 2000 with comparative methods used at sites 2 and 3. Median percentage differences with the comparative methods were 12, -1.4, and -5.6%. Comparison of capillary to venous sample results, from the DCA 2000, showed no clinically significant differences. Operator and physician feedback were positive with respect to technical ease in performance of the test and accuracy of results. CONCLUSIONS: Precision was acceptable and interlaboratory variability was low. The immunological method correlated well with manual ion-exchange and automated HPLC methods. The small sample size and good comparison between capillary and venous sample results make fingerstick sampling acceptable. The method provided immediate test results (within 9 min) to the clinicians.

Blood Specimen Collection↗

Immunological recognition of sodium/D-glucose cotransporter from renal brush border membranes by polyclonal antibodies.

Antisera prepared in rabbit to a D-glucose-inhibitable phlorizin binding component of the pig kidney brush border membrane precipitated more than 90 percent of the D-glucose-inhibitable phlorizin binding activity from a Triton extract. These antibodies also stimulated D-glucose uptake by native brush border membranes at low D-glucose concentrations (1 mM) and inhibited it at higher D-glucose concentrations. Immunoblotting was used to locate polypeptide subunits of the glucose transporter in polyacrylamide gels of proteins extracted from the brush border membranes. The antibodies labelled the Mr 70,000 phlorizin-binding component in both reducing and non reducing conditions. Two additional polypeptides with relative molecular mass of 120,000 and 45,000 were also recognized under the same conditions; they might correspond, respectively, to another Na+/D-glucose cotransport unit and to a post mortem degradation product.

Animals↗

Purification and properties of neutral maltase from human granulocytes.

A procedure for the purification of neutral maltase from human polymorphonuclear leukocytes is described, involving solubilization with Triton X-100, proteolytic attack and three chromatographic steps: DEAE ion exchange, AcA 22 gel filtration and a second DEAE chromatography. The enzyme was obtained with a final specific activity of 30 units/mg of protein, comparable with that of other neutral maltases previously purified. The Mr of the enzyme was 550,000 as determined by gel filtration. SDS/polyacrylamide-gel electrophoresis, under non-denaturing conditions, led to a major band of 500,000 and a minor one of 260,000, both active, suggesting a polymeric or aggregated form of the protein. The catalytic properties of the human granulocytic neutral maltase were investigated. The pH optimum was around 6. The enzyme exhibited a broad range of substrate specificity, hydrolysing di- and oligosaccharides with alpha (1----2), alpha (1----3) and alpha (1----4) glucosidic linkages. The highest activities were observed for alpha (1----4) glucose oligomers of three to five residues. It was also found to hydrolyse polysaccharides such as starch and glycogen. The results of the inhibition studies are interpreted in terms of the existence of a large site including several subsites. The enzyme properties are broadly similar to those observed for other purified neutral alpha-glucosidases, in particular that of human kidney origin.

Glycoside Hydrolase Inhibitors↗