PubMed Health⌕ Search

Biomedical subjects

C W Kong

Publications and source records attributed to C W Kong.

At least 19 recordsLinked to original sources

The prevalence of microalbuminuria among patients with type II diabetes mellitus in a primary care setting: cross-sectional study.

OBJECTIVES: To determine the prevalence of microalbuminuria among patients with type II diabetes mellitus in a primary care setting, and to study the association between various risk factors and the presence of microalbuminuria. DESIGN: Cross-sectional community-based study. SETTING: Four primary care clinics, Hong Kong. PATIENTS: All patients with type II diabetes mellitus who regularly attended the clinics between May 2002 and March 2003. MAIN OUTCOME MEASURES: Patients' demographic data, the proportion with microalbuminuria (measured using a spot urine test), and the association between this condition and risk factors for diabetic nephropathy (via correlation and multivariable logistic regression analysis). RESULTS: The mean age of the 1161 patients in the sample population was 58.0 years. The mean duration of diabetes mellitus was 5.7 years, and the mean level of glycated haemoglobin was 7.4%. A total of 13.4% of the patients had microalbuminuria. Having the condition was significantly associated with advanced age, female sex, poor glycaemic control, and coexisting hypertension in both correlation and regression analyses. No significant association with ever smoking was found. CONCLUSION: Early screening for incipient diabetic nephropathy and aggressive management of modifiable risk factors in a primary care setting may be important in optimising the renal outcome of patients with type II diabetes mellitus.

Adolescent↗

Oxidative DNA damage in human peripheral leukocytes induced by massive aerobic exercise.

Reactive oxygen species produced during vigorous exercise may permeate into cell nuclei and induce oxidative DNA damage, but the supporting evidence is still lacking. By using a 42 km marathon race as a model of massive aerobic exercise, we demonstrated a significant degree of unrepaired DNA base oxidation in peripheral immunocompetent cells, despite a concurrent increase in the urinary excretion of 8-hydroxy-2'-deoxyguanosine. Single cell gel electrophoresis with the incorporation of lesion-specific endonucleases further revealed that oxidized pyrimidines (endonuclease III-sensitive sites) contributed to most of the postexercise nucleotide oxidation. The oxidative DNA damage correlated significantly with plasma levels of creatinine kinase and lipid peroxidation metabolites, and lasted for more than 1 week following the race. This phenomenon may be one of the mechanisms behind the immune dysfunctions after exhaustive exercise.

8-Hydroxy-2'-Deoxyguanosine↗

Leukocyte mitochondria depolarization and apoptosis in advanced heart failure: clinical correlations and effect of therapy.

OBJECTIVES: The purpose of this study was to examine the changes in leukocyte mitochondrial transmembrane potential (MTP) and its association with apoptosis in congestive heart failure (CHF). BACKGROUND: Congestive heart failure is a heterogeneous syndrome with multiple hemodynamic, neuroendocrine and immune abnormalities. Although edematous CHF may be associated with endotoxemia and increased cytokine production, peripheral blood leukocyte functions in advanced CHF remain unclear. METHODS: Thirty patients with acute decompensated CHF (mean age [+/- SEM] 74.9 +/- 3.1 years) and 20 healthy controls underwent determination of MTP, intracellular oxidants and apoptosis in three subsets of peripheral blood leukocytes. The measurements were repeated after the time of recompensation. RESULTS: Patients with acute CHF showed marked MTP reduction and increased intracellular oxidant formation in three subsets of leukocytes upon entry into the study. These changes were more prominent in patients with peripheral edema. The decline in MTP was correlated with the severity of the peripheral edema and plasma concentration of cortisol, nitrogen metabolites and tumor necrosis factor-alpha (p < 0.01). After clinical stabilization, MTP gradually recovered. Leukocytes underwent increased propensity of apoptosis one week after the time of recompensation. CONCLUSIONS: The mitochondrial depolarization and apoptosis of leukocytes in decompensated heart failure suggest that CHF is associated with severity-dependent impairments in leukocyte function. Accentuated hormonal and cytokine abnormalities and increased circulating oxidants may contribute to these changes. Early and aggressive management of advanced heart failure is helpful in the recovery of these immune abnormalities.

Aged↗

Age-related changes in the mitochondrial depolarization induced by oxidative injury in human peripheral blood leukocytes.

Aging is associated with impaired immunity and reduced host defenses. Mitochondrial bioenergetic dysfunctions and reduced antioxidative ability of immunocompetent cells may contribute to this phenomenon. In this study, 60 healthy volunteers of different age groups donated their blood after overnight fasting. Leukocytes were subjected to oxidative injuries by exposure to t-butylhydroperoxide, and were labeled with fluorochromes for measuring mitochondria transmembrane potential (delta psi m), membrane peroxidation and mitochondrial oxidant formation. delta psi m declined after t-butylhydroperoxide exposure, and the change was more prominent in leukocytes from older individuals. Cyclosporin A partly restored delta psi m, implying the contributing role of mitochondrial permeability transition pores. The mitochondrial depolarization was accompanied by increased oxidant formation and oxidation of pyridine nucleotides, which were more prominent in older subjects. The results support the view that the bioenergetic functions of mitochondria are more susceptible to oxidative injury in aged individuals. The decreased ability of leukocytes to resist oxidative stress may contribute to immunosenescence in humans.

Adult↗

The relationship of late potentials to assessment of heart rate variability in post-infarction patients.

In order to investigate the relationship of late potential (LP) to assessment of heart rate variability (HRV) after acute myocardial infarction (AMI), we studied 101 Chinese patients with AMI (10+/-2.4 days) in Taiwan by collecting 24-h ECG from a Holter tape recorder and signal-averaged ECG from a high-resolution ECG cart. Of the 101 patients, 36 patients had LP (LP group) and 65 patients did not (NLP group). The mean heart rate was significantly lower in the LP group than in the NLP group (P<0.05). The LP group had a significantly increased high-frequency (HF) spectral component of HRV compared with the NLP group (P<0.005), but their low-frequency (LF) to HF ratio (LF/HF) was lower (P<0.05). Analysis of the circadian variation of HRV revealed significant difference of morning SDRR (standard deviation of normal RR intervals) compared with noon SDRR (P<0.05 in the LP group, P<0.005 in the NLP group) and evening SDRR (P<0.05 in the LP group, P<0.005 in the NLP group). In the NLP group, morning HF (normalized unit, nu) was 0.258+/-0.098 compared with noon HF (nu) of 0.219+/-0.83 (P<0.05) and evening HF (nu) of 0. 225+/-0.085 (P<0.05). Nine patients died during follow-up from cardiac causes, three (8.3%) in the LP group and six (9.2%) in the NLP group. In post-MI patients, there was higher vagal tone in patients with late potentials compared to those without late potentials. NLP patients had more circadian change in vagal tone compared with LP patients.

Adult↗

Magnolol attenuates peroxidative damage and improves survival of rats with sepsis.

Reactive oxygen species and peroxidative damage are implicated in the pathophysiology of sepsis. Magnolol is a compound extracted from the Chinese medicinal herb Magnolia officinalis and has multiple pharmacological effects, notably antioxidant functions. To determine whether magnolol can modulate the course of sepsis, survival rate and biochemical parameters were analyzed in rats with sepsis with various treatment protocols. Magnolol at doses ranging from 10(-9) g/kg to 10(-5) g/kg was administered either before or after induction of sepsis by cecal ligation and puncture. Magnolol did not modulate the course of sepsis induced by two cecal punctures. When one cecal puncture was performed, a moderately evolving type of sepsis was induced, and the survival rate of affected rats was significantly improved by pretreatment with 10(-7) g/kg magnolol. The beneficial effect was partially retained if magnolol was administered 6 hours after onset of sepsis when a higher dose (10(-5) g/kg) was used. The intensity of lipid peroxidation in plasma, liver, and lung of septic rats was also attenuated in a treatment-dependent manner. Magnolol at this dose range exerted these beneficial effects probably through its antioxidant efficacy. These significant results may suggest magnolol as a candidate agent for the treatment of sepsis.

Animals↗

Acute and chronic phase platelet aggregability studies in Chinese patients after implantation of a permanent transvenous pacemaker.

It has been suggested that the incidence of thromboembolic events always increases in patients after insertion of a transvenous pacemaker. Blood samples from twenty consecutive patients (fifteen males and five females) before and after pacemaker implantation was retained for platelet aggregability studies which were analyzed separately with ADP, collagen, epinephrine and arachidonic acid. The maximal amplitude of platelet aggregatory curve was detected by an aggregometer. The samples collected the day before pacemaker implantation (day 0) were used as self-control. Day 1 and day 3 after pacemaker implantation were defined as the acute phase, while day 30 was defined as the chronic phase. The maximal amplitude of platelet aggregatory curve was observed to be lowest on day 1 and then return to normal on day 3 and day 30. The results of platelet aggregability, however, showed no significant difference (P>0.05) between self-control and post-implantation samples. In conclusion, there was no significant change in platelet aggregability for either acute or chronic phases after pacemaker implantation. Antiplatelet medications may not be necessary for the prevention of thromboembolic events after the implantation of a pacemaker.

Aged↗

Factors affecting gentamicin pharmacokinetics in septic patients.

BACKGROUND: This prospective, comparative study was designed to estimate the volume of distribution (Vd) and elimination rate constant (K(e)) of gentamicin and to determine the clinical factors affecting the pharmacokinetics of gentamicin in different stages of sepsis. METHOD: Seventy-seven critically ill patients treated with gentamicin for gram-negative sepsis were included. These septic patients were divided into hyperdynamic septic and hypodynamic septic groups according to cardiac index. Twenty-seven patients who received postoperative prophylactic gentamicin were recruited as controls. RESULTS: Fifty-two patients in the hyperdynamic septic group had a significantly larger Vd than those in the hypodynamic septic and control groups. The Vd was correlated significantly with both Acute Physiological Score (APS) (r=0.340, P<0.01) and cardiac index (r=0.394, P<0.01). The K(e) of gentamicin correlated significantly with both blood urea nitrogen (BUN) (r= 0.565, P<0.01) and serum creatinine level (r=0.563, P<0.01). CONCLUSION: The increased Vd in the septic patients was related to the severity of illness and magnitude of cardiac output. The K(e) of gentamicin was correlated with the serum creatinine level.

APACHE↗

Esophageal PP intervals for analysis of short-term heart rate variability in patients with atrioventricular block before and after insertion of a temporary ventricular inhibited pacemaker.

Heart rate variability (HRV) analysis is a useful method for assessment of the activities of autonomic nervous system. The RR intervals in ECG is measured for this purpose. However, RR intervals are not suitable for HRV analysis in atrioventricular block (AV) block patients with ventricular inhibited (VVI) pacemaker, as the intervals will be fixed by the ventricular pacemaker. Thus we used an esophageal lead to detect PP intervals for analysis of HRV. The aim of this study was to evaluate the short-term HRV by using an esophageal electrode to detect the atrial signal and PP intervals in AV block patients. Fifteen AV block patients before and after temporary VVI pacemaker and 15 subjects with normal AV conduction (control group) were enrolled in this study. The atrial signals from esophageal lead, ECG and intraatrial lead were recorded. The duration was 10 min. We compared correlation coefficient of PP intervals from different leads in AV block patients and the control group. We also compared the PP interval's variability parameters between the control group and AV block patients, before and after insertion of a temporary ventricular inhibited pacemaker. The esophageal PP intervals were excellently correlated with intraatrial AA intervals (r=0.98+/-0.01). The HRV using esophageal PP intervals with time domain demonstrated a significant decrease in patients with AV block (standard deviation of all PP intervals (SDNN) (s)=0.022+/-0.014; percentage difference between adjacent PP intervals that are greater than 50 ms (pNN-50) (%)=0.052+/-0.038; square root of the mean of squares of differences between duration of neighboring PP intervals (r-MSDD) (s)=0.322+/-0.082) but this returned to normal after insertion of a temporary ventricular inhibited pacemaker (SDNN (s)=0.035+/-0.009; pNN-50 (%)=2.540+/-1.682; r-MSDD (s)=0.542+/-0.190). However, the ratio of low frequency/high frequency (LF/HF) still increased (LF/HF=4.120+/-1.802). The result of this short-term HRV analysis suggested that withdrawal of vagal tone or increased sympathetic activity in AV block patients compared with the control group. This appearance was normalized after insertion of a temporary VVI pacemaker. however, abnormal sympathovagal balance still remained.

Aged↗

Anatomical variation of the internal jugular vein and its impact on temporary haemodialysis vascular access: an ultrasonographic survey in uraemic patients.

BACKGROUND: Creation of a reliable haemoaccess is a critical problem for practicing nephrologists once haemodialysis has been considered. A double-lumen internal jugular-vein catheter is favoured in most cases requiring temporary haemoaccess. However, numerous complications, even lethal ones, may occur with the cannulating procedure. Using ultrasound, we attempted to describe the occult anatomical variations of vessels which may be responsible for complications. METHODS: A 'SiteRite' ultrasonographic device was used to inspect the anatomical structure of the internal jugular veins (IJV) in 104 consecutive uraemic patients undergoing creation of internal jugular vein temporary angioaccess. Images of the vessels and demographic data of patients were recorded and analysed. RESULTS: Anatomical variations of the right and left IJVs were found in 19 (18.3%) and 17 (16.4%) uraemic patients respectively. Unilateral IJV variations were found in 18 patients (17.3%) and bilateral variations were discovered in nine patients (8.7%). A total of 27 patients (26.0%) had IJV anatomical variations that might contribute to difficulty in external landmark-guided IJV cannulation. CONCLUSIONS: The external anatomical landmarks for cannulating the IJV are not reliable in about one-quarter of uraemic patients. An ultrasound survey on the IJV anatomy is recommended for selecting proper puncture site and reducing risks of insertion complications for IJV dialysis catheters.

Adult↗

Oxidative stress: an important phenomenon with pathogenetic significance in the progression of acute pancreatitis.

BACKGROUND: Reactive oxygen species and related oxidative damage have been implicated in the initiation of acute pancreatitis. Changes in these parameters during disease progression merit further investigation. AIMS: To evaluate changes and the clinical relevance of superoxide radicals, endogenous antioxidants, and lipid peroxidation during the course of acute pancreatitis. PATIENTS AND METHODS: Superoxide radicals (measured as lucigenin amplified chemiluminescence), ascorbic acid, dehydroascorbic acid, alpha tocopherol, and lipid peroxidation (measured as thiobarbiturate reactive substances) were analysed in blood samples from 56 healthy subjects, 30 patients with mild acute pancreatitis, and 23 patients with severe acute pancreatitis. The association with grades of disease severity was analysed. Measurements were repeated one and two weeks after onset of pancreatitis. RESULTS: In the blood from patients with acute pancreatitis, there were increased levels of the superoxide radical as well as lipid peroxides. There was notable depletion of ascorbic acid and an increased fraction of dehydroascorbic acid. Changes in alpha tocopherol were not great except in one case with poor prognosis. Differences between severe and mild acute pancreatitis were significant (p < 0.01). Variable but significant correlations with disease severity scores were found for most of these markers. The normalisation of these indexes postdated clinical recovery one or two weeks after onset of disease. CONCLUSIONS: Heightened oxidative stress appears early in the course of acute pancreatitis and lasts longer than the clinical manifestations. The dependence of disease severity on the imbalance between oxidants and natural defences suggests that oxidative stress may have a pivotal role in the progression of pancreatitis and may provide a target for treatment.

Acute Disease↗

Ultrasound-guided cannulation of the internal jugular vein for dialysis vascular access in uremic patients.

BACKGROUND: A reliable temporary vascular access is always required for hemodialysis when a permanent vascular access is not available. However, techniques for creating temporary vascular accesses remain imperfect. This study utilized the 'SiteRite' ultrasound device to improve both success and complication rates of jugular venous cannulation for temporary access. METHODS: This prospective, comparative study recruited 104 uremic patients receiving ultrasound-guided and 86 patients undergoing landmark-guided percutaneous internal jugular venous cannulation of dual-lumen dialysis catheters. Success rate, number of puncture attempts, access time, and the complication rate of the ultrasound technique, in comparison with the landmark-guided technique, were studied. RESULTS: The ultrasound-guided cannulation was superior to the external landmark-guided cannulation in overall success rate (99.0 vs. 86.0%, p < 0.01), success rate of the first puncture attempt (80.8 vs. 34.9%, p < 0.01), average puncture (access) times (15.8 vs. 43.7 s, p < 0.01), puncture trials (1.39 vs. 2.58, p < 0.01), and traumatic complication rate (1.9 vs. 1 1.6%, p = 0.015). The incidence of infective complications for the ultrasound group was not different from that of the landmark-guided groups (2.9 vs. 2.3%, p = 0.589). CONCLUSION: The ultrasound-guided technique offers both safety and convenience in inserting jugular venous dialysis catheters. It represents a valuable technique in creating temporary dialysis hemoaccesses.

Adult↗

Malfunction of an active fixation J-shaped screw-in atrial electrode lead: a case report.

Active fixation leads, using active grasping devices, ensure good postoperative lead fixation, long-term performance, and make possible later lead removal on demand. However, these delicate designs have not been without practical difficulties. We present two cases of fixation stylet fracture during helix extension and retraction maneuver respectively with resultant lead inoperability and abandonment. The fixed leads could be removed by torquing the entire lead counterclockwise.

Adult↗

New stenosis on proximal coronary segment after directional atherectomy. Two case reports.

Two patients with new coronary stenotic lesions subsequently developed proximal to the sites accepting directional coronary atherectomy (DCA) are reported. One lesion developed at the left main coronary artery and the other at the proximal segment of the left anterior descending artery. The mechanisms of the development of such new stenotic lesions after DCA were studied and procedure-related mechanical trauma over the proximal segment of the primary lesion may be the possible mechanism for such complication.

Aged↗

Right ventricular electrode lead implantation via a persistent left superior vena cava. An improved technique.

Persistent left superior vena cava occurs in approximately 0.5% of the population. This may complicate pacemaker implantation by making lead insertion difficult and causing lead instability through the left cephalic vein and the subclavian vein approach. We used a wide loop technique in the right atrium and successfully advanced the lead in the right ventricle apex. A persistent left superior vena cava does not preclude successful lead placement.

Aged↗

Heart rate variability in patients with atrioventricular block.

BACKGROUND: Heart rate variability (HRV) analysis has been an established method for assessment of the activities of autonomic nervous system. Conventionally, the RR intervals from the surface electrocardiogram (ECG) are used for HRV analysis, however, analysis of the RR intervals may not be suitable in patients with atrioventricular (AV) node dysfunction, particularly in patients with certain degree of AV block. We used an esophageal electrode to detect PP intervals for HRV analysis in these patients. METHODS: Seven AV block patients and 13 subjects with normal AV conduction (control group) were enrolled in this study. The signals from esophageal lead, surface lead and intraatrial lead were recorded. Correlation coefficient of heart beat intervals from different leads was analyzed. Then we compared the HRV parameter recorded by esophageal lead between AV block patients and the control group. RESULTS: The AA intervals in intraatrial ECG and the PP intervals in surface ECG were poorly correlated (r = 0.489) in the AV block patients. However, intraatrial ECG was correlated well with esophageal ECG (r = 0.968). HRV with time domain decreased significantly in patients with AV block. The standard deviation of NN intervals (SDNN), pNN-50 and r-MSSD in the control group and the AV block patients were 0.035 +/- 0.006 vs. 0.021 +/- 0.016 seconds (p = 0.002), 3.210 +/- 3.120 vs. 0.050 +/- 0.040% (p = 0.027) and 0.577 +/- 0.181 vs. 0.318 +/- 0.084 seconds (p = 0.009), respectively. CONCLUSIONS: The esophageal lead recording is a non-invasive, easy and safe method to detect HRV of AV block patients whose vagal activity is abnormal.

Electrocardiography↗

Changes in cardiac autonomic activities in patients with syndrome X. A study of spectral analysis of heart rate variability.

The present study was designed to assess cardiac autonomic activities, coronary microvascular function, and their relationship in patients with syndrome X. Control of coronary blood flow is complex, and impaired coronary flow reserve has been attributed as the cause of myocardial ischemia in patients with syndrome X. It is unknown whether cardiac autonomic activities are altered in the presence of coronary microvascular dysfunction in patients with syndrome X. Eighteen patients with syndrome X were studied. Great cardiac vein flow was measured by the thermodilution method and the coronary flow reserve was determined by intravenous dipyridamole (0.56 mg/kg) infusion. Twenty-four-hour ambulatory electrocardiograms were obtained in a drug-free state. Another 14 age- and sex-matched normal subjects served as a control group. The amplitude (in ms) of ultralow (ULF), very-low (VLF), low (LF), and high (HF) frequency bands and total spectra of heart rate variability were measured for twenty-four-hour and every four-hour interval of the day.

Adult↗

Effects of right ventricular pacing on ventriculoatrial conduction and systemic venous responses in sick sinus patients.

This study was designed to assess the ventriculoatrial (VA) conduction and systemic venous responses to right ventricular pacing at different pacing rates and the feasibility of identifying patients prone to pacemaker syndrome by means of a Doppler and two-dimensional echocardiographic technique. Twenty-two sick sinus patients who received ventricular-demand permanent pacemakers constituted the study group. The proximal inferior vena cava (IVC) diameters were measured by two-dimensional echocardiography. Fourteen patients had VA conduction by preimplant electrophysiologic study or paced electrocardiogram (Group II), while the other 8 patients presented no VA conduction (Group I). Abnormal systolic retrograde flow in the hepatic vein following each paced beat could be demonstrated in those patients with VA conduction in the basal state. In the 8 patients without VA conduction, the IVC diameters were significantly increased during rapid right ventricular pacing in those with left ventricular dysfunction (n = 4) as compared with those with normal left ventricular function (n = 4) (% increment at 120 beats per minute.

Blood Flow Velocity↗