PubMed HealthSearch

Biomedical subjects

C W Tyler

Publications and source records attributed to C W Tyler.

At least 19 recordsLinked to original sources

Disparity tuning in mechanisms of human stereopsis.

The change in sensitivity across some stimulus dimension which follows adaptation to a particular stimulus can reveal a great deal about the tuning characteristics of underlying sensory/perceptual mechanisms. In this study, a psychophysical adaptation paradigm was employed to characterize the disparity tuning of perceptual mechanisms involved in stereopsis. The stimulus was a dynamic random-dot stereogram (DRDS) portraying a surface which varied in interocular correlation (IOC) and retinal disparity. Adaptation to a fully correlated DRDS surface produced an elevation in IOC threshold over a relatively narrow range of disparities, with maximum effect at the disparity of the adapting stimulus. The width of these disparity tuning functions varied from 5 arc min for adaptation at the horopter to 20 arc min for adaptation at 20 arc min disparity. Frequently, IOC sensitivity was enhanced for disparities on either side of the adapted disparity, suggesting that an opponent center-surround organization operates at an early level of disparity processing. A model of underlying channel structure consistent with these data is presented.

Adaptation, Ocular

Failure of rivalry at low contrast: evidence of a suprathreshold binocular summation process.

Presentation of different images to the two eyes normally results in a time-varying alternation between the two images (binocular rivalry). However, we find that when orthogonal gratings are viewed dichoptically at low contrast, a stable summation between the two images is perceived in the form of a dichoptic plaid. The range of perception of the dichoptic plaid depends on spatial frequency, contrast and luminance of the gratings. This phenomenon differs from the "false fusion", a fleeting summation of different images perceived only under very brief presentation of the stimuli. The observations suggest that there exists a neural process that performs a summation of dissimilar images, and that is distinct from the competitive process of suppression and binocular rivalry.

Contrast Sensitivity

Different spatial tunings for ON and OFF pathway stimulation.

We compared the spatial tuning of sensitivity to luminance increments and decrements in three types of localized stimulus presentation with a smooth spatiotemporal envelope. The first type consisted of spatiotemporal Gabor grating functions with either a positive or a negative bias in luminance. The spatial tuning showed a substantially narrower bandwidth and greater peak sensitivity for the positive Gabors. A similar description could be applied to the results for detection of spots with a 2-D difference-of-Gaussian profile, although the shape of the tuning function differed in several respects. We also used the biased Gabor modulation in a contrast self-masking paradigm, where the increment (or decrement) was presented against a steady background with the same spatial configuration, over a range of base contrasts. At medium spatial frequencies the biased masking functions were similar to those typically found for unbiased gratings, in showing a threshold facilitation (dipper) at low contrast, and sub-Weber masking behaviour at higher contrasts. At low spatial frequencies, however, a pronounced asymmetry appeared. Stimuli with a positive bias again showed typical masking behaviour, but a virtually flat masking function was obtained for negative bias stimuli. We conclude that stimuli without abrupt luminance transients reveal pronounced differences in the spatial tuning of responses to positive and negative stimuli, which probably reflect differences in the neural connectivity of the ON and OFF processing systems.

Contrast Sensitivity

Psychophysical derivation of the impulse response through generation of ultrabrief responses: complex inverse estimation without minimum-phase assumptions.

A new technique is presented for the psychophysical measurement of the response phase that requires no assumptions of the relation between the phase and amplitude components of the frequency response. The amplitude attenuation is measured by a standard threshold paradigm and is then compensated for by increasing harmonic strength in proportion to the visual attenuation. Then the phase of each frequency component is adjusted to maximize the internal response amplitude. The amplitude and phase values may be converted by inverse Fourier transformation into the estimated visual impulse response in any stable set of stimulus conditions and are insensitive to a wide variety of response nonlinearities. A key aspect of the phase measurement technique is the generation of a stimulus to obtain the minimum time spread of the internal response, creating a briefer response than for any other stimulus.

Computer Simulation

Analysis of visual modulation sensitivity. V. Faster visual response for G- than for R-cone pathway?

To determine the linear, unadapted responses of the cone pathways, we have measured the critical fusion frequency (CFF) for green (555-nm) and red (642-nm) flicker as a function of retinal illuminance. Both functions obeyed the Ferry-Porter law (CFF proportional to log illuminance) to high accuracy over a > or = 5-log-unit range. In both foveola and periphery the CFF/illuminance functions were significantly steeper for green light than for red light. The peripheral 555-nm function had an average slope 1.26 times the average slope of the 642-nm function. An additive model of flicker detection could not account for the observed differences in slope. A threshold independence model, in which detection is based on the most sensitive mechanism, accurately fits the data. Whichever model is assumed, the presence of different slopes for the two wavelength flicker conditions strongly implies that the R- and G-cone pathways have different temporal properties. The occurrence of steeper CFF/illuminance slopes in response to green light implies that the linear (near-CFF) response of the G-cone pathways in inherently faster than that of the R-cone pathways at both retinal loci. These differences in R- and G-cone-mediated temporal properties complicate the fundamental concept of luminance and invalidate it for precise application over the full illuminance range.

Color Perception

Local versus general anesthesia: which is safer for performing suction curettage abortions?

The relative safety of suction curettage abortions performed with either local or general anesthesia has not been clearly established. To compare the safety of these two anesthetic techniques, we studied 36,430 women who received local anesthetics and 17,725 who received general anesthetics for this operation in the United States from 1971 through 1975. The aggregated major complication rates for the two groups were similar, but there were significant differences between local and general anesthesia for specific complications and treatments. Local anesthesia was associated with higher rates of febrile and convulsive morbidity; however, general anesthesia was associated with higher rates of hemorrhage, cervical injury, and uterine perforation. Both anesthetic techniques appear to be safe, with similar degrees of overall safety, although each is associated with a different spectrum of complications.

Abdomen

Epidemiology of hepatocellular adenoma. The role of oral contraceptive use.

A case-control study of hepatocellular adenoma (HCA), a serious though nonmalignant liver tumor, was conducted by the Center for Disease Control and the Armed Forces Institute of Pathology (AFIP). Interviews with 79 women with HCA and with 220 age- and neighborhood-matched controls were completed. Limited information was obtained on nine additional patients who had died. Women with HCA and hemorrhage have a greater risk of morbidity and death than those with other symptoms. Increasing duration of OC use increases the risk of HCA. Use of OCs with high hormonal potency and age over 30 years may further increase a woman's risk of HCA. Long-term users of OCs have an estimated annual incidence of HCA of 3 to 4 per 100,000.

Adolescent

The health impact of restricting public funds for abortion. October 10, 1977--June 10, 1978.

The Center for Disease Control (CDC), Atlanta, Georgia implemented an eight-month prospective surveillance system in 24 hospitals distributed among states with and without public funding for abortion. Out of 3,157 visits for abortion-related complications, only 10 women gave a history of non-physician or self-induced abortion and none were Medicaid recipients. The small number of hospitals located in non-funded states and the smaller numbers of women served in these hospitals than in the funded states limited the power of out study. Women living along the Texas-Mexico border appeared more likely to have complications after illegal abortions than women from other areas of the country.

Abortion, Illegal

Rapid assessment of visual function: an electronic sweep technique for the pattern visual evoked potential.

We have developed an electronic spatial frequency sweep technique for electrophysiological assessment of visual acuity and pattern vision. The technique allows an accurate and reliable measurement of VEPs to a full range of spatial frequencies in just 10 sec. Because the measurements are so rapid, the technique suggests several new improvements in the assessment of visual function. Sweeping spatial frequency linearly and extrapolating the high-frequency region of the VEP spatial-tuning function to zero voltage allows an estimate of acuity which correlates highly with psychophysical estimates of acuity. Variants of the procedure are appropriate for the assessment of refracture error, determination of equality of visual function for the two eyes and of binocular interactions, and for sequential assessment of therapeutic conditions.

Amblyopia

Multiple spatial-frequency tuning of electrical responses from human visual cortex.

Human occipital potentials evoked by stimulation with a counterphase flickering grating were recorded by a digital narrowband filter technique. The data showed a surprising degree of narrow tuning to particular spatial frequencies in addition to the expected narrow temporal frequency tuning. At each temporal frequency, there could be two or more peaks of different spatial frequencies, each distinct from the whole field flicker response. Variations in this multiple spatial frequency tuning were investigated as a function of luminance, electrode location, and temporal frequency for several observers. The results are interpreted in terms of many stimulus-specific resonant neural circuits within the brain, and suggest that it is possible to make a highly detailed exploration of the responses of neural circuits to visual stimulation.

Electroencephalography

Legalized abortion: effect on national trends of maternal and abortion-related mortality (1940 through 1976).

Both non-abortion-related maternal and abortion-related mortality declined prior to the Supreme Court decisions of 1973. In order to determine the effect of legalized abortion on maternal mortality, we have analyzed the secular trends in national abortion mortality ratios for 1940 through 1976, compared the trends to those maternal mortality ratios, and hypothesized reasons for differences between these trends. Between 1940 and 1950 and after 1965, deaths from abortion declined more rapidly than deaths from other causes associated with childbirth. However, between 1951 and 1965, maternal mortality related to pregnancy of childbirth declined more rapidly than abortion-related mortality. Five possible explanations exist for the more rapid decline in abortion deaths since 1965--selected underreporting, changes in coding practices, improved safety of illegal abortion, introduction of more effective contraception, and increased availability of legal abortion. We consider the last two explanations as the most likely reasons for the accelerated decline in abortion-related deaths.

Abortion, Legal