Effects upon the fetus of oxygen administration to the mother. A study in monkey.

Catheters were placed into assorted arteries and veins of 8 anaesthetized pregnant monkeys and their fetuses. Oxygen-sensitive electrodes were also inserted subcutaneously into 3 of the 8 fetuses. Periodic samples of maternal and fetal blood were analyzed for PO2, PCO2 and pH. Oxygen administration to the mothers reliably increased the PO2 of blood taken from the fetal carotid artery and less constantly augmented the PO2 of blood withdrawn from the femoral artery and vein. During 5-6 hours of study the oxygen tension of fetal blood samples of all animals progressively declined. However, the most marked declines in PO2 values at all fetal sites were regularly observed at those times as--or after--the mothers emerged from anaesthesia. At these times also the magnitudes of the increases in fetal blood PO2 brought about by administering oxygen to the mothers diminished markedly and in parallel at all sample sites. The closely similar magnitudes of these various reductions at all fetal sample sties indicate that the basic mechanisms leading to decreased oxygen delivery lie outside the fetuses and are most likely due to decreased maternal blood flow to the uterus because of increased maternal sympathetic stimulation. These reductions in oxygen delivery to the fetus are all regularly reversed by reanasthetizing the mothers. The studies carried out with oxygen-sensitive electrodes demonstrate that administering oxygen to the mothers regularly increases oxygen tension of fetal tissues but after a 50 sec delay.

Animals

Gas flow in relation to blood flow in oxygenators. An evaluation of the new Shiley bubble oxygenator.

A new bubble oxygenator, designed by the Shiley Laboratories, which utilizes a low gas flow for oxygenation, was first tested in dogs and then in 100 clinical cases. For perfusion in adult patients, a gas flow as low as 0.6 litre oxygen per 1 litre blood has given adequate oxygenation and removal of carbon dioxide with no untoward effect on the blood, as compared with other oxygenators, including the membrane type.

Adult

A transcutaneous PO2 electrode for continuous monitoring of fetal state during delivery.

A transcutaneous PO2 electrode has been designed and constructed for the continuous measurement of fetal oxygen tension during labor and delivery. The electrode, tested in vitro, has a low oxygen consumption, a short response time, 10 sec, and a sufficient stability, 5% over 3 hr. The in vivo performance of the electrode, tested in neonates, shows a good correlation between transcutaneous PO2 and PO2 measured in samples of arterial blood. The continous registration of fetal tcPO2 during labor and delivery is exemplified.

Delivery, Obstetric