PubMed Health⌕ Search

Biomedical subjects

Cai Qi

Publications and source records attributed to Cai Qi.

7 recordsLinked to original sources

A label-free protein microfluidic array for parallel immunoassays.

A label-free protein microfluidic array for immunoassays based on the combination of imaging ellipsometry and an integrated microfluidic system is presented. Proteins can be patterned homogeneously on substrate in array format by the microfluidic system simultaneously. After preparation, the protein array can be packed in the microfluidic system which is full of buffer so that proteins are not exposed to denaturing conditions. With simple microfluidic channel junction, the protein microfluidic array can be used in serial or parallel format to analyze single or multiple samples simultaneously. Imaging ellipsometry is used for the protein array reading with a label-free format. The biological and medical applications of the label-free protein microfluidic array are demonstrated by screening for antibody-antigen interactions, measuring the concentration of the protein solution and detecting five markers of hepatitis B.

Animals↗

Investigation of interaction between two neutralizing monoclonal antibodies and SARS virus using biosensor based on imaging ellipsometry.

Two neutralizing human scFv, b1 and h12 were identified initially using ELISA,employing highly purified virus as the coating antigen. The biosensor technique based on imaging ellipsometry was employed directly to detect two neutralizing monoclonal antibodies and serial serum samples from 10 SARS patients and 12 volunteers who had not SARS. Further, the kinetic process of interaction between the antibodies and SARS-CoV was studied using the real-time function of the biosensor. The biosensor is consistent with ELISA that the antibody h12 showed a higher affinity in encountering the virus than antibody b1. The affinity of antibody b1 and antibody h12 was 9.5 x 10(6) M(-1) and 1.36 x 10(7) M(- 1), respectively. As a label free method, the biosensor based on imaging ellipsometry proved to be a more competent mechanism for measuring serum samples from SARS patients and the affinity between these antibodies and the SARS coronavirus.

Antibodies, Monoclonal↗

[Application of optical proteinchip in detecting phage M13KO7].

Avidin layer was bound on the substrate surface of Silicon wafer modified with aldehyde. The interaction between avidin and biotin was adopted for the immobilization of mouse monoclonal biotin-anti-M13 (antibody GP3)-labeled biotin. The surface was incubated in a solution containing phage M13KO7, which was trapped by the antibody GP3 with the interaction between phage M13KO7 and antibody GP3, resulting in a variation of layer thickness that was detected by imaging ellipsometry. The results showed a saturated layer of antibody GP3 with a thickness about 6.9 nm on the surface of the silicon wafer. The specific interaction between phage M13KO7 and antibody GP3 resulted in a variation of the layer thickness. The layer of phage M13KO7 bound with antibody GP3 was 17.5 nm in the concentration of 1.1 x 10(10) pfu/mL. Each variation of layer thickness corresponded to a concentration of phage M13KO7 in the range of 0.1 x 10(10) approximately 2.5 x 10(10) pfu/mL, with the sensitivity of 10(9) pfu/mL. Compared with other methods, the optical protein-chip requires only short measurement time, is label free, is a quantitative test, and can be visualized. This study could be significant on the investigation of interactions between the antibody and virus, and shows potential in the early diagnosis of virosis.

Animals↗

A human neutralizing antibody against a conformational epitope shared by oligomeric SARS S1 protein.

An antibody phage-display library was constructed from the B cells of convalescent severe acute respiratory syndrome (SARS) patients and screened using inactivated SARS coronavirus (CoV) virions as antigens. More than 80 positive clones were isolated from the library and one of them, scFv H12, was extensively characterized. scFv H12 bound to SARS-CoV with high affinity (equilibrium dissociation constant, Kd=73.5 nM), and neutralized SARS virions in vitro. The facts that scFv H12 bound to the SARS-S1 protein under non-reducing conditions and that it did not bind to monomeric S1 protein under reducing conditions strongly suggest that scFv H12 recognizes a conformational epitope shared by oligomeric S1 proteins. This study should aid in the manufacture of neutralizing antibody, provide a better understanding the immunological characteristics of SARS protein and facilitate the design of a SARS vaccine.

Amino Acid Sequence↗

A human SARS-CoV neutralizing antibody against epitope on S2 protein.

An immune antibody phage-display library was constructed from B cells of SARS convalescent patients. More than 80 clones were selected from the library by using the whole inactivated SARS-CoV virions as target. One human scFv, B1, was characterized extensively. The B1 recognized SARS pseudovirus in vivo and competed with SARS sera for binding to SARS-CoV with high affinity (equilibrium dissociation constant, K(d) = 105 nM). The B1 also has potent neutralizing activities against infection by pseudovirus expressing SARS-CoV S protein in vitro. Finally, we found that the B1 recognized an epitope on S2 protein, especially within amino acids 1023-1189 of S2 protein. This study not only first made a human neutralizing antibody, which recognized an epitope on S2 protein like natural antibody in sera, but also may help us to better understand the immunological characteristics of SARS protein and SARS vaccine design.

Antibodies↗

[Expression and renaturation of a novel human single-chain Fv antibody against SARS-CoV].

A novel human ScFv H12 against SARS-CoV has been selected from a SARS immune library. In order to produce a large amount of ScFv H12, pET28a-H12 expression vector was constructed and ScFv H12 was expressed at yield about 30% of total proteins in E. coli . Here two different refolding procedures were used to refold ScFv H12 from inclusion body: gel filtration chromatography and dilution. The results showed that ScFv H12 could be efficiently refolded by both procedures. However, the refolding via gel filtration was 1.5 time more effective than that of dilution. The affinity of ScFv H12 to SARS-CoV virion was detected as Kd = 73.5 nmol/mL.

Antibodies, Monoclonal↗