Surface optimization technique for MammoSite breast brachytherapy applicator.

PURPOSE: We present a technique to optimize the dwell times and positions of a high-dose-rate (192)Ir source using the MammoSite breast brachytherapy applicator. The surface optimization method used multiple dwell positions and optimization points to conform the 100% isodose line to the surface of the planning target volume (PTV). METHODS AND MATERIALS: The study population consisted of 20 patients treated using the MammoSite device between October 2002 and February 2004. Treatment was delivered in 10 fractions of 3.4 Gy/fraction, twice daily, with a minimum of 6 h between fractions. The treatment of each patient was planned using three optimization techniques. The dosimetric characteristics of the single-point, six-point, and surface optimization techniques were compared. RESULTS: The surface optimization technique increased the PTV coverage compared with the single- and six-point methods (mean percentage of PTV receiving 100% of the prescription dose was 94%, 85%, and 91%, respectively). The surface method, single-point, and six-point method had a mean dose homogeneity index of 0.62, 0.68, and 0.63 and a mean full width at half maximum value of 189, 190, and 192 cGy/fraction, respectively. CONCLUSION: The surface technique provided greater coverage of the PTV than did the single- and six-point methods. Using the FWHM method, the surface, single-, and six-point techniques resulted in equivalent dose homogeneity.

Brachytherapy↗

The MammoSite breast brachytherapy applicator: a review of technique and outcomes.

The MammoSite breast brachytherapy device was designed to overcome the potential scheduling problems associated with external beam radiotherapy (EBRT) and the technical difficulties of multi-catheter-based interstitial brachytherapy. The device consists of a silicone balloon connected to a catheter which contains an inflation channel and a port for passage of a high-dose-rate brachytherapy source. The American Brachytherapy Society and American Society of Breast Surgeons have published partial breast irradiation (PBI) patient selection guidelines. The MammoSite applicator has been shown in two dosimetric studies to treat a comparable volume to multicatheter-based interstitial implants. The MammoSite catheter can be placed at the time of lumpectomy or in a separate procedure using ultrasound guidance. Four optimization methods have been described: the single point method, the six prescription point method (RUSH Technique), the University of Southern California Norris Cancer Center Method, and the Surface Optimization Technique. An excellent or good cosmetic outcome has been reported in 80% to 93% of patients at 1 year in most studies. Cosmetic results appear highly related to skin spacing. The MammoSite applicator has been associated with early side effects comparable with traditional breast conserving therapy. A NSABP trial will randomize patients to either whole breast irradiation or PBI consisting of interstitial brachytherapy, MammoSite brachytherapy, or 3D conformal radiation.

Brachytherapy↗

Treatment volume and dose optimization of MammoSite breast brachytherapy applicator.

PURPOSE: Limited information has been reported on the dosimetry achieved with the MammoSite breast brachytherapy applicator. We present our results regarding the volume of treatment and a comparison of a single prescription point, single dwell position optimization technique with a six prescription point, multiple dwell position method. METHODS AND MATERIALS: Between October 14, 2002 and February 28, 2003, 21 patients with early-stage breast cancer were treated using the MammoSite device. The treatment was delivered in 10 fractions of 3.4 Gy/fraction, b.i.d., with a minimum of 6 hours between the daily fractions. CT of the lumpectomy cavity was obtained both with and without the inflated balloon. A planning target volume was constructed using a three-dimensional planning system. A three-dimensional expansion of the balloon surface was performed using the chest wall and skin as limiting structures. The volume of the inflated balloon was removed from this volume, and the volume of tissue treated in each patient was determined. A sequential expansion in 1-mm increments around the empty lumpectomy cavity was performed until the closest equivalent volume to the planning target volume was obtained. The treatment for the patients in this study was planned using both a single prescription point, single dwell position optimization technique and a six-prescription point, multiple dwell position technique. The single prescription point method has been described in a previous publication. The six-prescription point method used six points placed 1 cm from the balloon surface. Four points are in a plane transverse to the balloon axis perpendicular to the axis of the catheter, and two points are placed along the axis of the catheter. The prescription points along the catheter axis are used to compensate for the decreased dose coverage owing to anisotropy dose distribution of the source. The Nucletron HDR Plato Brachytherapy planning system was used to optimize the source positions and dwell times. RESULTS: The volume of breast tissue treated by the MammoSite device was equal to the volume encompassed by a mean 1.6-cm (SD, 0.1) margin around the empty lumpectomy cavity. Compared with the single prescription point optimization method, the six prescription point method provided better dose coverage, with a mean percentage of volume receiving 90% of the prescription dose of 97.2% (SD = 2.1) vs. 89.5% (SD = 4.6) for the single-point method. The mean percentage of volume receiving 100% of the prescription dose was 88.9% (SD = 3.3) for the six-point method vs. 77.6% (SD = 6.1) for the single-point method. However, compared with the single-point method, the six-point optimization method resulted in treatment that was less uniform, with a mean dose homogeneity index of 0.62 (SD =.07) vs. 0.66 (SD =.08) for the single-point method. CONCLUSION: The volume of normal breast tissue treated by the MammoSite device is comparable to other methods of interstitial brachytherapy that treat a 1-2-cm margin of tissue around the excision cavity. The six-prescription point, multiple dwell position method improved dose coverage with a slight decrease in dose homogeneity. The six-point method offers greater reliability of dose coverage compared with the single-point method by providing an increased number of reference points.

Adult↗

Early experience with balloon brachytherapy for breast cancer.

HYPOTHESIS: Partial-breast irradiation for carcinoma by a single source of radiation placed in the center of a balloon inserted in the lumpectomy cavity is an effective method of treating breast cancer. Previous interstitial radiation therapy using iridium seeds placed within multiple catheters has been shown to be effective but impractical and cosmetically unacceptable to women. DESIGN: Prospective registry study. SETTING: Three university and community hospitals. PATIENTS: Women 40 years and older with histologically diagnosed in situ and invasive T1 through T2 and N0 or N1 breast cancer treated with lumpectomy and axillary node sampling were invited to enter this institutional review board-approved study. MAIN OUTCOME MEASURES: Evaluation of immediate and short-term complications, patients' acceptance of the treatment, and cosmesis are reported. RESULTS: Of the 129 eligible patients enrolled, 112 completed the treatment. Of these, transient skin erythema was noted in 28, localized edema in 3, and skin blisters adjacent to the balloon in 9. Infection developed in 7, necessitating drainage and antibiotic administration. In 10 patients, sonographically demonstrated seromas that developed after removal of the device were aspirated percutaneously. In 4 patients, punctured or ruptured balloons had to be replaced before the treatment could be completed. Patients quickly adjusted to the breast distension caused by the balloon, and their acceptance of the procedure was good. The cosmetic outcome was rated high. There were no recurrences during this very short follow-up. CONCLUSIONS: Our early short-term experience indicates balloon brachytherapy to be an acceptable alternative to external beam radiation for selected operable breast cancers. The 1-week treatment time allows working women and those who live at a distance from radiation centers to choose breast conservation rather than mastectomy.

Adult↗

Dose perturbation induced by radiographic contrast inside brachytherapy balloon applicators.

Phantom measurements and Monte Carlo calculations have been performed for the purpose of characterizing the dose perturbation caused by radiographic contrast inside the MammoSite breast brachytherapy applicator. Specifically, the dose perturbation is quantified as a heterogeneity correction factor (HCF) for various balloon radii and contrast concentration levels. The dose perturbation is larger for larger balloon radii and higher contrast concentrations. Based on a validated Monte Carlo simulation, the calculated HCF values are 0.99 for a 2 cm radius balloon and 0.98 for a 3 cm radius balloon at 6% contrast concentration levels, and 0.89 and 0.87 for 2 and 3 cm radius balloons, respectively, at 100% contrast concentrations. For a typical implanted balloon radius of 2.4 cm, the HCF values decrease from 0.99 at 6% contrast concentration to 0.90 at 100% contrast concentration. For balloons implanted in patients at our institution, the mean HCF is 0.99, corresponding to a dose reduction of approximately 1%. The contrast effect results in a systematic reduction in the delivered dose, therefore the minimal amount of radiographic contrast necessary should be used.

Angiography↗

Correlates of failure following treatment with Sr-90 beta irradiation for in-stent restenosis.

We sought to determine the correlates of failure following intracoronary radiation therapy (IRT) with Sr-90 using the Novoste Beta-Cath system for the treatment of in-stent restenosis (ISR) in a broad range of patients. IRT has been shown to be more efficacious compared to placebo for the treatment of ISR in large randomized trials. However, even in patients treated with IRT, major adverse cardiac events occur in approximately 20% of cases on follow-up. This trial sought to elucidate the correlates of failure following successful IRT for ISR. To determine the correlates of IRT failure, we retrospectively compared the demographics, lesion characteristics, and clinical outcomes of 102 consecutive patients with ISR treated with Sr-90 from September 1998 to July 2001. IRT failure was defined as death, myocardial infarction (MI), or target vessel revascularization (TVR) due to repeat ISR on follow-up. A comparison of the clinical and angiographic profile of IRT failures (n = 16) vs. IRT successes (n = 86) revealed that a history of smoking (75% vs. 40%; P = 0.012), current use of calcium channel blockers (84% vs. 45%; P = 0.013), ostial location of target lesion (44% vs. 16%; P = 0.020), and mean posttreatment minimal luminal diameter (MLD; 1.64 +/- 0.19 vs. 2.21 +/- 0.29 mm; P < 0.001), respectively, were correlated with failure using univariate analysis. After multivariate regression analysis, the correlates of failure that remained significant were treatment of an ostial lesion (OR = 31.2; 95% CI = 2.6-382.7; P = 0.007) and final posttreatment MLD (P < 0.001). Ostial location of target lesion and smaller posttreatment MLD are correlated with subsequent death, MI, and TVR following therapy with Sr-90 for ISR.

Aged↗

Intracoronary beta brachytherapy as a treatment option for high-risk refractory in-stent restenosis; Compassionate use.

BACKGROUND: Vascular (VBT) has clearly been shown in multiple clinical trials to decrease restenosis rates for in-stent restenosis (ISR). However, patients enrolled in these randomized clinical trials represent a select group, and the efficacy of VBT in patients with ISR who were excluded from these controlled trials due to more complex coronary anatomy requires further investigation. This study sought to define the angiographic and clinical profile and outcomes of these high-risk patients with ISR who were excluded from the randomized clinical trials and who received VBTusing Strontium-90 (Sr-90) using the Novoste Beta-Cath System through a Compassionate Use Protocol (CUP). METHODS: The study was designed as a single center, prospective, open label registry trial evaluating the use of VBT on complex instent restenotic lesions in patients who were excluded from the START and START 40 trials. In general, these patients included those with saphenous vein graft (SVG) lesions, long lesions (>35 mm), and patients with a history of more than three prior interventions. VBT using Sr-90 was delivered using the Novoste Beta-Cath System after successful angioplasty. The predetermined primary endpoint was freedom from target vessel revascularization (TVR) at 8 months, one and two years. The secondary endpoint was a composite of death, myocardial infarction (MI) and TVR at 8 months, one year, and two years. RESULTS: Between September 4, 1998 and December 6, 2000, 32 patients were treated with VBT under the UCP protocol. The mean duration of follow up was 15.3 +/- 8.3 months. There were 9 major cardiac events at eight months including one death, one acute myocardial infarction and 7 TVR. Excluding the one patient who died, 33 lesions were available for follow-up. The rate of TVR in this high-risk patient population was 21.1% (n = 7/33 lesions). The method of revascularization included one bypass surgery and 6 repeat percutaneous coronary interventions. CONCLUSIONS: This trial demonstrates that utilization of the Beta-Cath System using Sr-90 for the treatment of ISR in a patient population excluded from the randomized clinical trials due to unfavorable lesions characteristics is feasible appears to be associated TVR rates that compare favorably with the event rates of patients enrolled in other trials enrolling lower-risk groups.

Aged↗

Clinical and angiographic outcomes of cardiac transplant patients treated with intracoronary beta-radiation for in-stent restenosis: a case series.

BACKGROUND: Vascular brachytherapy (VBT) is effective for the treatment of in-stent restenosis (ISR), however, the effect of VBT clinical and angiographic outcomes of patients with ISR who have undergone orthotopic heart transplantation (OHT) requires further study. METHODS: All OHT patients with ISR treated with VBT using the Novoste Beta-Cath System at Rush University Medical Center were identified, and the clinical and angiographic outcomes were evaluated. RESULTS: Four OHT patients with ISR who underwent VBT were identified. The mean age was 48.5 years, and the mean duration posttransplantation was 7.5 years. The mean reference coronary vessel diameter was 3.06 mm. The primary interventional device utilized prior to VBT was cutting balloon angioplasty (CBA) in 75% and percutaneous balloon angioplasty in 25%. The mean duration of follow-up after VBT was 11 months. There were no deaths attributable due to cardiac disease, no myocardial infarction, and no target vessel revascularization on follow-up. Overall survival during this period was 75%, with one mortality due to stroke 8 months after VBT. CONCLUSIONS: VBT for the treatment of ISR in patients who have undergone OHT appears safe and feasible and is associated with acceptable clinical and angiographic outcomes.

Angioplasty, Balloon, Coronary↗

Clinical outcomes of patients treated with the cutting balloon and Sr-90 beta-irradiation for instent restenosis.

BACKGROUND: The cutting balloon (CB) is an emerging therapy for the treatment of instent restenosis (ISR), but its impact on the clinical outcomes of patients treated with intracoronary radiation therapy (IRT) with Sr-90 compared with conventional PTCA and IRT is not clearly defined. METHODS: We compared the baseline demographics, angiographic characteristics and clinical outcomes of 102 consecutive patients with ISR treated either with CB+IRT (n=45) or with conventional PTCA+IRT (n=57). The combined endpoint was the occurrence of major adverse cardiac events (MACE), which was defined as a composite of death, myocardial infarction (MI) or target vessel revascularization (TVR) at 6 months. RESULTS: The CB+IRT group had a shorter mean lesion length (14.3+/-6.5 vs. 21.1+/-15.7, P=.009), and greater utilization of glycoprotein IIb/IIIa inhibitors during the procedure (48.9% vs. 26.3%, P=.02) compared to the PTCA+IRT group. There were no significant differences in the baseline demographics, angiographic and procedural results, or subsequent MACE at 6 months between the two groups. CONCLUSION: The strategy of CB+IRT using Sr-90 for ISR is associated with similar procedural and clinical outcomes compared to conventional PTCA+IRT. Further study is warranted to determine which patient subgroups would derive the most benefit from this approach.

Aged↗

Visual assessment of procedural results following treatment with Sr-90 beta-radiation for instent restenosis.

BACKGROUND: Visual assessment (VA) of postprocedural % diameter stenosis (DS) is used routinely in clinical practice to determine the adequacy of coronary intervention. Although VA has been shown to underestimate final %DS after balloon angioplasty compared to quantitative coronary angiography (QCA), the impact of this effect on clinical outcomes following treatment with intracoronary radiation therapy (IRT) with Sr-90 for instent restenosis (ISR) is unknown. METHODS: To determine the effect of VA on the rate of major adverse cardiac events (MACEs) after IRT for ISR, we compared the clinical outcomes of 102 consecutive patients based on postprocedural %DS by QCA vs. %DS by VA. MACE was defined as death, M1 or need for target vessel revascularization (TVR). RESULTS: MACE rates for the 102 consecutive patients grouped according to postprocedural %DS by QCA and VA were compared. The mean %DS by QCA was 30.7%, while the mean %DS by VA was 12.5%. The mean %DS by VA across the QCA subgroups were 13.67%, 10.71% and 13.37%, respectively (P = .244). Fifty-two patients (51.0%) had %DS > 30% by QCA with the highest MACE percentage occurring in this subgroup. CONCLUSION: VA underestimated the %DS compared to QCA, and it was associated with worse MACE following treatment with Sr-90 for ISR.

Beta Particles↗

Predictors of late cardiac events following treatment with Sr-90 beta-irradiation for instent restenosis.

BACKGROUND: Intracoronary radiation therapy (IRT) with Sr-90 using the Novoste Beta-Cath system has been shown to be an effective therapy for instent restenosis (ISR), but the temporal occurrence of cardiac events and the predictors of late complications require further investigation. METHODS: We analyzed the demographics, lesion characteristics and clinical outcomes of 138 consecutive patients with ISR treated with IRT from September 1998 to March 2002. Major adverse cardiac events (MACE) were defined as death, myocardial infarction (MI) or target vessel revascularization (TVR). Characteristics of early (< or =8 months) and late (>8 months) failures were analyzed. RESULTS: Thirty-two (23.1%) of 138 patients had MACE on follow-up; 25% (8/32) of failures occurred late after treatment with IRT. A comparison of the clinical and angiographic profile of early and late failures using univariate analysis indicates no correlations to late failure following IRT. Duration to failure after IRT was 14.25+/-3.69 months in the late group compared to 4.63+/-2.86 months in the early group (P<.001). CONCLUSIONS: Late MACE after IRT with Sr-90 for ISR occur beyond the traditional period for clinical restenosis in 25% of cases and are difficult to predict. Further study is warranted to identify patients at risk for the development of late complications after IRT.

Aged↗

Cosmetic outcome and incidence of infection with the MammoSite breast brachytherapy applicator.

We present our results regarding the cosmetic outcome achieved and the rate of infection using the MammoSite breast brachytherapy applicator to treat patients with partial breast irradiation. In addition, factors associated with cosmetic outcome and infection are analyzed. The study population consisted of 30 patients with early stage breast cancer treated using the MammoSite device from October 28, 2002, to February 13, 2004. Cosmetic outcome was analyzed for its association with the following parameters: volume of the balloon, balloon-to-skin distance, maximal skin point dose per fraction, V100 (percent of volume that received 100% of the prescription dose), V150 (percent of volume that received 150% of the prescription dose), and V200 (percent of volume that received 200% of the prescription dose). The occurrence of infection at the time of treatment and during follow-up was also recorded. At a median follow-up of 13 months (range 1-16 months), 53.3% of the patients (16/30) were reported to have an excellent cosmetic outcome and 40.0% (12/30) had a good cosmetic outcome. Excellent cosmetic outcome was associated with a greater mean balloon-to-skin distance compared to those who achieved a good cosmetic outcome (1.5 cm versus 1.2 cm) (p = 0.164). The mean V100, V150, and V200 of those in the excellent cosmetic outcome group were 92.1%, 34.5%, and 7.6% versus 93.0%, 34.7%, and 7.6% in the good cosmetic outcome group (p = 0.642, 0.926, and 0.853), The mean balloon volumes were 47.7 cm3 and 56.9 cm3, respectively (p = 0.063) in the excellent and good outcome groups. The mean maximal skin doses per fraction in the excellent and good outcome groups were 354.8 cGy and 422.3 cGy (p = 0.286), respectively. Infection occurred in 13.3% of the patients (4/30). An excellent or good cosmetic outcome was achieved in 93.3% of patients and infection occurred in 13.3% of patients treated with the MammoSite breast brachytherapy applicator. Excellent cosmetic outcome was associated with a greater balloon-to-skin distance, lower maximal skin dose per fraction, and smaller mean balloon volume; however, the results did not reach statistical significance.

Adult↗