Aseptic loosening, not only a question of wear: a review of different theories.

Today, aseptic loosening is the most common cause of revision of major arthroplasties. Aseptic loosening accounts for more than two-thirds of hip revisions and almost one-half of knee revisions in Sweden. Several theories on the cause of aseptic loosening have been proposed. Most of these theories, however, are based on empiric observations, experimental animal models or anecdotal cases. In this review, we discuss the most common theories concerning aseptic loosening. It emerges from this review that aseptic loosening has a multifactorial etiology and cannot be explained by a single theory.

Animals↗

Retrieved implants from irradiated sites in humans: a histologic/histomorphometric investigation of oral and craniofacial implants.

PURPOSE: The aim of this report was to quantitatively and qualitatively evaluate the tissue response to bone-anchored implants retrieved from irradiated sites in patients. MATERIALS AND METHODS: The material consists of 23 consecutively received Brånemark implants (Nobel Biocare AB, Göteborg, Sweden) placed in pre- or postoperatively irradiated sites. Twenty-two of the 23 implants were suitable for histologic evaluation of undecalcified sections in the light microscope. RESULTS: The oral implants with shorter time in situ demonstrated sparse bone to implant contact with mainly dense connective tissue in the interface. However, for implants with longer time in situ, high amounts of bone-implant contact and bone fill of threads were noted. The mean values of bone-implant contact and bone area within the thread were calculated to 40% (16-94) and 70% (13-96), respectively. The craniofacial implants, with the exception of two implants lined with a capsular formation, demonstrated mature and newly formed bone at the bone-implant interface. The mean value for bone-metal contact was calculated to 45 and 53% for two specimens. The mean value for bone area within the thread ranged from 65 to 88% for three specimens. CONCLUSION; The possibility to achieve bone anchorage of implants in irradiated tissue was supported by the findings in this study. However, due to limited material, conclusions with regard to radiation dose and bone tissue response to implants cannot be stated.

Aged↗

Bone ingrowths to press-fit and loose-fit implants: comparisons between titanium and hydroxyapatite.

The aim of this study was to investigate whether the coating of titanium (Ti) implants with hydroxyapatite (HA) might create a better fixation when titanium implants are implanted into a gap. In each of 16 rats, the medullary cavity of both femurs was entered by an awl from the trochanteric area. With steel burrs it was successively reamed to a diameter of 1.5 mm. In a random manner the proximal part of the cavity in half of the bones was reamed once again to a diameter of 2.0 mm. Nails with a diameter of 1.5 mm and a length of 34 mm were then inserted into the medullary cavity of these bones with press fit at the distal half and a gap to the bone in the proximal half. In the remaining bones the whole medullary canal was reamed to a diameter of 2.0 mm, and nails with a diameter of 2.0 mm and a length of 34 mm were introduced. In all cases, either a pure Ti nail or a Ti nail entirely plasma sprayed with HA was used in a random manner. The surface roughness of the pure Ti was characterized by Ra 2.6 microm and Rt 22 microm. Ra of HA was 7.5 microm and Rt 52 microm. At sacrifice after 16 weeks, both femurs were dissected free from soft tissues and then immersed in fixative. A specimen slice of about 5 mm in thickness was prepared from the subtrochanteric region with a water-cooled band saw. Sample preparation for undecalcified tissue followed the internal guidelines at the laboratories of the Department of Biomaterials/Handicap Research. Generally, bone contact to the nails with HA coating was more predictable than was bone contact to the Ti nails. But due to rather large variations in bone contact between the samples, statistical analyses revealed non-significant differences between the 4 groups (p = 0.083). There were no significant differences between Ti and HA coated nails of 2.0 mm (p = 0.633), nor between Ti and HA coated nails of 1.5 mm (p = 0.924). The pooled values for the 2.0 mm nails showed significantly higher bone bonding contact than the pooled values of the 1.5 mm nails (p = 0.011). Our results, then, indicate that bone bonding contact to implants with a loose fit insertion is less predictable than in press fit insertion, and HA coating seemed to be more predictable than pure Ti. However, due to large variations between the samples, the differences did not reach significant levels.

Animals↗

Hydroxyapatite enhances long-term fixation of titanium implants.

The aim of this study was to evaluate osseous integration of hydroxyapatite coated titanium implants over time as compared to pure titanium. In 20 rats the medullary cavity of both femoral bones was entered by an awl from the trochanteric area. With steel burrs it was successively reamed to a diameter of 2.0 mm. Nails with a diameter of 2.0 mm and with a length of 34 mm were inserted into the medullary cavity; a pure titanium nail on the left side and a titanium nail entirely plasma-sprayed with hydroxyapatite (HA) on the right side. The surface roughness of the pure titanium was characterized by Ra 2.6 microm and Rt 22 microm, and HA had a roughness of Ra 7.5 (arithmetical mean roughness) microm and Rt (maximum profile height) 52 microm. The rats were randomized to a follow-up of 6 and 12 months, respectively. At sacrifice the femoral bones were dissected free from soft tissues. The bones were radiographed and then immersed in fixative. A specimen-slice of about 5 mm thickness was prepared from the region under the trochanter minor with a water cooled band-saw. Sample preparation for undecalcified tissue followed the internal guidelines at the laboratories of Biomaterials/Handicap Research. At 6 months the median bone bonding contact of the implants was 40% (range 0-92) in the titanium group and 34% (0-86) in the HA group. At 12 months the median bone bonding contact was 51% (0-97) in the titanium group and 86% (72-98) in the HA group. In conclusion, we found a significant (p = 0.001) increase in bone bonding contact from 6 to 12 months of the HA coated nails and significantly (p = 0.043) enhanced bone bonding contact in HA coated nails at 12 months as compared to pure titanium nails.

Animals↗

Histologic evaluation of Brånemark clinic oral implants retrieved from grafted sites.

PURPOSE: The aim of this report is to quantitatively and qualitatively describe the bone tissue response to Brånemark implants retrieved from grafted sites in patients. MATERIALS AND METHOD: The material consists of consecutively received Brånemark implants retrieved from grafted sites. Thirty-five of these implants, retrieved from 16 patients, were suitable for the histologic evaluation of undecalcified sections in the light microscope. RESULTS: The unloaded implants were mainly lined with soft tissue, and sparse bone-implant contact was observed only in some sections. The loaded implants, with the exception of one implant removed due to mobility, had mature and new bone-implant contact. Resorption of graft through cutting cone structures was detected. Cement lines were found separating bone-like tissue albeit no cellular content and bone tissue with detectable osteocytes. CONCLUSION: In this heterogeneous group of implants from grafted sites, the unloaded implants showed limited bone-implant contact. The autografts showed seemingly mixed viability as judged by the cell content in the osteocyte lacunae and cement lines separating areas with filled and empty lacunae.

Bone Transplantation↗

A descriptive study on retrieved non-threaded and threaded implant designs.

OBJECTIVES: In the light microscope compare the amount of bone saucerization for non-threaded cylindrical and threaded implant designs in retrieved samples from patients. MATERIAL AND METHOD: Consecutively received retrieved oral implants from 117 patients, whereof 85 non-threaded cylindrical and 85 Brånemark implants, have been included in the study. For 75 non-threaded cylindrical and 46 Brånemark implants was the entire implant length available for calculation. Undecalcified ground sections were investigated in the light microscope with calculation of percentage of implant length coronal to the first bone-implant contact and percentage of bone to implant contact. RESULTS: Mean value for implant length coronal to first bone-implant contact was 65%, standard error of the mean (SEM) 3 (range 0-100%), for non-threaded cylindrical implants and 43%, SEM 6 (range 0-100%) for Brånemark implants. Mean values of bone contact along the entire implant length was 23%, SEM 2 (range 0-65%), for the non-threaded cylindrical implants and 33%, SEM 5 (range 0-93%) for the Brånemark implants. CONCLUSION: Within the limitations of this retrospective, retrieval study non-threaded cylindrical implants demonstrated a greater bone saucerization when evaluated in the light microscope.

Adult↗

A study of 275 retrieved Brånemark oral implants.

The aim of this report was to describe the bone tissue response to Brånemark oral implants retrieved from patients. The material consisted of consecutively received Brånemark threaded oral implants and related patient data provided by clinicians. The implant samples were processed into undecalcified sections for evaluation under the light microscope. The analysis demonstrated a lower percentage of bone-to-implant contact for the unloaded implants as compared to the loaded implants. When the threads were divided into four different regions, the loaded implants had a lower percentage of bone-contacting length at the thread top as compared to the other three regions.

Adaptation, Psychological↗

Hydroxyapatite and carbon coatings for fixation of unloaded titanium implants.

The aim of this study was to investigate the interaction between bone and pure titanium, titanium coated with hydroxyapatite (HA), and titanium coated with carbon in a rat femur model. In 25 rats, the medullary cavity of both femurs was entered by an awl from the trochanteric area. With steel burrs it was successively reamed to a diameter of 2.0 mm. Nails with a diameter of 2.0 mm and with a length of 34 mm were inserted in a random manner; either a pure titanium nail, a titanium nail entirely plasma-sprayed with a 75-100-microm layer of HA or a titanium nail coated with 2-10-microm carbon. The surface roughness of the pure titanium was characterized by Ra 2.6 microm and Rt 22 microm. Ra of HA was 7.5 microm and Rt 52 microm, and of carbon Ra was 0.4 microm and Rt 4.0 microm. Twelve rats were randomized to a follow up of 8 weeks, and the remaining 13 rats were followed for 16 weeks. At sacrifice both femora were dissected free from soft tissues and then immersed in fixative. A specimen slice of about 5 mm thickness was prepared from the subtrochanteric region with a water-cooled band-saw. Sample preparation for un-decalcified tissue followed the internal guidelines at the laboratories of Biomaterials/Handicap Research. At 8 weeks the median bone bonding contact of the implants was 43% (range 0-74) in the titanium group, 39% (0-75) in the HA group, and 3% (0-59) in the carbon group. At 16 weeks the corresponding figures were 58% (0-78) in the titanium group, 51% (15-75) in the HA group, and 8% (0-79) in the carbon group. In conclusion, we found great variability in bone bonding contact. In general, carbon-coated nails had reduced bone bonding contact both at 8 and at 16 weeks as compared to pure titanium or titanium coated with hydroxyapatite.

Analysis of Variance↗

FGF-4 and titanium implants: a pilot study in rabbit bone.

AIM: To evaluate the effect of a local single injection of amino-terminally truncated recombinant human fibroblast growth factor-4 (rhFGF-4s) on titanium implant incorporation in a rabbit bone. MATERIAL AND METHODS: Thirty-six threaded titanium implants were inserted into the femur and tibia of six rabbits. Three weeks prior to implant insertion 10 microg of FGF-4 in an altelocollagen carrier or the carrier alone was injected into the intended implant sites. Biomechanical evaluation by (i) resonance frequency analysis and (ii) peak removal torque measurements was performed after 6 weeks. The implants with surrounding tissue were processed to undecalcified ground sections followed by light-microscopic quantifications of the bone in threaded area and the apical parts of the implants. RESULTS: A general trend, however not statistically significant, with higher mean values obtained in the above-mentioned tests was found. The FGF-4-treated implants revealed a significantly increased bone area in the apical part of the implants compared to the corresponding control implants. CONCLUSION: A local single injection of rhFGF-4 may stimulate bone formation around titanium implants in bone. However, further research is required to confirm these results, understand the mechanisms of FGF, and establish optimal dose and delivery methods.

Animals↗

Long-term results of a cementless knee prosthesis with a metal-backed patellar component: clinical and radiological follow-up with histology from retrieved components.

Aseptic loosening of cemented knee arthroplasties has encouraged development of uncemented fixation. The Miller-Galante I (MG I) prosthesis was designed to achieve permanent stability through ingrowth into a titanium fiber mesh. Thirty-five knees in 30 patients with MG I knee replacements have been followed clinically and radiologically with a mean follow-up of 12 years. Twenty knees were revised with a mean follow-up of 5 years. Patellofemoral problems, especially avulsion of the polyethylene from the metal-backed patella and in some cases severe metallosis, have been the main reason for revision. Metal-backed patellar component should be avoided. In addition, instability has been a problem. However, the fixation of the components has been excellent, with a high degree of osseous ingrowth displayed at histological analysis of retrieved components. The clinical and radiological results after revision are in most cases good, despite the femoral component having been left in situ.

Arthroplasty, Replacement, Knee↗

Characteristics of the surface oxides on turned and electrochemically oxidized pure titanium implants up to dielectric breakdown: the oxide thickness, micropore configurations, surface roughness, crystal structure and chemical composition.

Titanium implants have been used widely and successfully for various types of bone-anchored reconstructions. It is believed that properties of oxide films covering titanium implant surfaces are of crucial importance for a successful osseointegration, in particular at compromized bone sites. The aim of the present study is to investigate the surface properties of anodic oxides formed on commercially pure (c.p.) titanium screw implants as well as to study 'native' oxides on turned c.p. titanium implants. Anodic oxides were prepared by galvanostatic mode in CH3COOH up to the high forming voltage of dielectric breakdown and spark formation. The oxide thicknesses, measured with Auger electron spectroscopy (AES), were in the range of about 200-1000 nm. Barrier and porous structures dominated the surface morphology of the anodic film. Quantitative morphometric analyses of the micropore structures were performed using an image analysis system on scanning electron microscopy (SEM) negatives. The pore sizes were < or = 8 microm in diameter and had 1.27-2.1 microm2 opening area. The porosity was in the range of 12.7-24.4%. The surface roughness was in the range of 0.96-1.03 microm (Sa), measured with TopScan 3D. The crystal structures of the titanium oxide were amorphous, anatase, and a mixtures of anatase and rutile type, as analyzed with thin-film X-ray diffractometry (TF-XRD) and Raman spectroscopy. The chemical compositions consisted mainly of TiO2, characterized with X-ray photoelectron spectroscopy (XPS). The native (thermal) oxide on turned implants was 17.4 nm (+/- 6.2) thick and amorphous. Its chemical composition was TiO2. The surface roughness had an average height deviation of 0.83 microm (Sa). The present results are needed to elucidate the influence of the oxide properties on the biological reaction. The results of animal studies using the presently characterized surface oxides on titanium implants will be published separately.

Crystallography, X-Ray↗

Qualitative and quantitative observations of bone tissue reactions to anodised implants.

Research projects focusing on biomaterials related factors; the bulk implant material, the macro-design of the implant and the microsurface roughness are routinely being conducted at our laboratories. In this study, we have investigated the bone tissue reactions to turned commercially pure (c.p.) titanium implants with various thicknesses of the oxide films after 6 weeks of insertion in rabbit bone. The control c.p. titanium implants had an oxide thickness of 17-200 nm while the test implants revealed an oxide thickness between 600 and 1000 nm. Routine histological investigations of the tissue reactions around the implants and enzyme histochemical detections of alkaline and acid phosphatase activities demonstrated similar findings around both the control and test implants. In general, the histomorphometrical parameters (bone to implant contact and newly formed bone) revealed significant quantitative differences between the control and test implants. The test implants demonstrated a greater bone response histomorphometrically than control implants and the osteoconductivity was more pronounced around the test implant surfaces. The parameters that differed between the implant surfaces, i.e. the oxide thickness, the pore size distribution, the porosity and the crystallinity of the surface oxides may represent factors that have an influence on the histomorphometrical results indicated by a stronger bone tissue response to the test implant surfaces, with an oxide thickness of more than 600 nm.

Acid Phosphatase↗

Does sodium fluoride in bone cement affect implant fixation? Part I: bone tissue response, implant fixation and histology in nine rabbits.

The addition of sodium fluoride to poly (methyl-methacrylate) (PMMA) bone cement may theoretically improve the fixation of joint replacement. This hypothesis was tested in an animal model using nine mature healthy lop-eared rabbits. A femoral prosthesis was inserted in both knees to resurface the patellofemoral articulation. The same acrylic cement, with and without sodium fluoride, was randomised between the two sides for prosthetic fixation. Two screw shaped implants machined from cured rods of either cement were also inserted bilaterally into the proximal tibia. Qualitative and quantitative histomorphometry of the bone tissue response surrounding the cement in the femur and the intact tibial implants revealed similar results regardless of sodium fluoride addition. Six weeks after surgery removal, torque did not significantly differ between the two sides. Our findings indicate that addition of sodium fluoride to PMMA has little effect on implant stability and bone remodeling in rabbits in the short-term.

Journal Article↗

Does sodium fluoride in bone cement affect implant fixation. Part II: evaluation of the effect of sodium fluoride additions to acrylic bone cement and the fixation of titanium implants in ovariectomized rabbits.

Bone integration of threaded implants made of cured polymethylmethacrylate containing sodium fluoride or commercially pure (c.p.) titanium were studied in normal and estrogen deficient New Zealand white rabbits. Nine had been ovariectomized through laparoscopy and nine served as controls. Four weeks after the ovariectomy two threaded implants made of cured bone cement with or without sodium fluoride addition were inserted in each tibia. One threaded commercially pure titanium implant was inserted in each patello-femoral joint flush to the cartilage. Six weeks after implant insertion measurement of the peak removal torque necessary to loosen the implants and light microscopical histomorphometrical investigations of tissue integration were performed. In the ovariectomized rabbits addition of sodium fluoride to the cement resulted in increased area of bone in the threads (p=0.04), but no corresponding effect could be noted in the controls. The removal torque was lower in the ovariectomized rabbits compared to the non-ovariectomized when comparing implant with sodium fluoride addition (p=0.02). The bone tissue response and the removal torque of the titanium implants were not influenced by ovariectomy in these rabbits.

Journal Article↗

Resonance frequency and removal torque analysis of implants with turned and anodized surface oxides.

The present experimental study was designed to address two issues. The first was to investigate whether oxide properties of titanium implants influenced bone tissue responses after an in vivo implantation time of six weeks. If such a result was found, the second aim was to investigate which oxide properties are involved in such bone tissue responses. Screw-shaped implants with a wide range of oxide properties were prepared by electrochemical oxidation methods, where the oxide thickness varied in the range of 200 nm to 1000 nm. The surface morphology was prepared in two substantially different ways, i.e. barrier and porous oxide film structures. The micropore structure revealed pore sizes of 8 microm in diameter, with a range in opening area from 1.27 microm 2 to 2.1 microm 2. Porosity ranged from 12.7% to 24.4%. The crystal structures of the titanium oxide were amorphous, anatase and a mixture of anatase and rutile type. The chemical compositions consisted mainly of TiO2. Surface roughness ranged from 0.96 microm to 1.03 microm (Sa). Each group of test samples showed its own, defined status with respect to these various parameters. The oxide properties of turned commercially pure titanium implants were used in the control group, which was characterized by an oxide thickness of 17.4 +/- 6.2 nm, amorphous type in crystallinity, TiO2 in chemical composition, and a surface roughness of 0.83 microm (Sa). Bone tissue responses were evaluated by resonance frequency measurements and removal torque tests that were undertaken six weeks after implant insertion in rabbit tibia. Implants that had an oxide thickness of approximately 600, 800 and 1000 nm demonstrated significantly stronger bone responses in the evaluation of removal torque values than did implants that had an oxide thickness of approximately 17 and 200 nm (P < 0.05). However, there were no difference between implants with oxide thicknesses of 17 and 200 nm (P = 0.99). It was concluded that oxide properties of titanium implants, which include oxide thickness, micropore configurations and crystal structures, greatly influence the bone tissue response in the evaluation of removal torque values. However, it is not fully understood whether these oxide properties influence the bone tissue response separately or synergistically.

Animals↗

Effect of submicron polyethylene particles on an osseointegrated implant: an experimental study with a rabbit patello-femoral prosthesis.

In a rabbit model of a weight bearing, articulating prosthetic joint we repeatedly injected submicron particles of Ultra-High-Molecular-Weight-Polyethylene (UHMWPE) produced in a hip simulator. The contralateral knee with the same prosthesis was injected with carrier (NaCl) without UHMWPE. Histomorphometrical studies on undecalcified cut and ground sections at 26 and 42 weeks involved quantifications of the entire bone to metal contact and the bone area around each implant. We found no statistically significant differences between test and control groups, and the UHMWPE debris did not induce any significant osteolysis, indicating that an osseointegrated implant with a sealed interface may not be affected by UHMWPE debris or progress to aseptic loosening.

Humans↗

HA particles can be released from well-fixed HA-coated stems: histopathology of biopsies from 20 hips 2-8 years after implantation.

20 hip arthroplasties with a Landos Corail Ti6Al4V stem entirely plasma-sprayed with a 155+/-35 microm thick HA coating were reoperated on after median 6 (2-8) years because of polyethylene wear (10), acetabular loosening (7), instability (2), or infection (1). We took biopsies from the proximal femurs adjacent to the well-fixed stems. Undecalcifled sections were prepared and examined with a light microscope. The biopsies contained median 5 (1.3-16 ) mm metal interface with 54% HA, 32% bone, and 14% soft tissue. The median thickness of the remaining HA coating was 137 (6-380) microm, and the HA-tissue interface included 89% bone and 11% soft tissue. All HA coatings showed partial degradation and replacement by soft tissue, osteoid-like tissue, or bone. 6 hips had tissue ingrowth between HA and metal consistent with delamination. 14 hips showed bone resorptive areas containing some HA particles and large amounts of polyethylene and metal particles, partly internalized in multinucleated giant cells and macrophages. Bone resorption was associated with metal and polyethylene particles, but not with HA particles. The HA coatings were undermined, resulting in release of large flakes of HA with free access to the articulation. We believe this mechanism may be responsible for third-body wear.

Adult↗

Craniofacial titanium implants and chronic pain: histologic findings.

OBJECTIVE: To determine whether histologic features or histomorphometric outcomes of retrieved craniofacial percutaneous titanium implants could be found that could be related to chronic pain at the implant site in the temporal bone. STUDY DESIGN: Histologic investigation and histomorphometric measurements of seven retrieved titanium implants with surrounding bone tissue. SETTING: Tertiairy referral center. PATIENTS AND METHODS: Four patients who had previously received percutaneous titanium implants for auricular prostheses (1 patient) and a bone anchored hearing aid (three patients) had chronic pain at the implant site despite conservative treatment. The implants were retrieved, sectioned, and ground for qualitative light microscopic inspection and quantitative measurement of the bone-to-metal contact and bone area. RESULTS: Qualitative inspection of the sections of the implants demonstrated soft tissue zones at the interface, especially under the flange. Inflammatory cells were seen in the interface in all seven implants. In the implants with good bone-to-metal contact, the percentage of bone-to-metal contact rose with time. In the two implants with poor bone-to-metal contact, the soft tissue zones were more extensive, and slightly more skin reactions were observed than in the other implants while still in situ. CONCLUSION: A clear explanation for the chronic pain is not at hand. The only common histologic findings were the inflammatory cells present in the interface, but with varying density, and the presence of soft tissue zones. A variety of bone-to-metal was found among the retrieved implants.