PubMed Health⌕ Search

Biomedical subjects

Carl C Crandell

Publications and source records attributed to Carl C Crandell.

4 recordsLinked to original sources

Effects of frequency modulation (FM) transmitter microphone directivity on speech perception in noise.

Frequency modulation (FM) technology can significantly improve the speech perception ability of individuals with sensorineural hearing loss (SNHL) in background noise. Previous investigations have demonstrated that the microphone design of the FM transmitter can have a significant impact on this improved speech perception. The purpose of this investigation was to compare 3 types of FM transmitter microphone designs: (a) wide angle (omnidirectional microphone), which amplifies sounds coming from all directions around the microphone equally; (b) zoom (1 directional microphone), which provides less amplification to signals coming from the rear, and (c) superzoom (2 directional microphones), which provides less amplification to signals originating from the rear and the sides. Fifteen adults with bilateral slight to moderately severe SNHL participated. Speech perception was assessed using the Hearing in Noise Test (M. Nilsson, S. Soli, and J. Sullivan, 1994). Speech spectrum shaped noise served as the noise competition. Results revealed that the best speech perception in noise was obtained when the FM transmitter was used in the zoom setting. The poorest performance was obtained when the FM transmitter was in the wide-angle mode. The clinical implications of these results are discussed.

Adult↗

Speech perception in noise: directional microphones versus frequency modulation (FM) systems.

The major consequence of sensorineural hearing loss (SNHL) is communicative difficulty, especially with the addition of noise and/or reverberation. The purpose of this investigation was to compare two types of technologies that have been shown to improve the speech-perception performance of individuals with SNHL: directional microphones and frequency modulation (FM) systems. Forty-six adult subjects with slight to severe SNHL served as subjects. Speech perception was assessed using the Hearing in Noise Test (HINT) with correlated diffuse noise under five different listening conditions. Results revealed that speech perception was significantly better with the use of the FM system over that of any of the hearing aid conditions, even with the use of the directional microphone. Additionally, speech perception was significantly better with the use of two hearing aids used in conjunction with two FM receivers rather than with just one FM receiver. Directional microphone performance was significantly better than omnidirectional microphone performance. All aided listening conditions were significantly better than the unaided listening condition.

Adult↗

Comorbid auditory processing disorder in developmental dyslexia.

OBJECTIVE: The primary objective of this study was to investigate the extent of comorbid auditory processing disorder (APD) in a group of adults with developmental dyslexia. An additional objective was to compare performance on auditory tasks to results from standardized tests of reading in an attempt to generate a clinically useful profile of developmental dyslexics with comorbid APD. DESIGN: A group of eleven persons with developmental dyslexia and 14 age- and intelligence-matched controls participated in the study. Behavioral audiograms, 226-Hz tympanograms, and word recognition scores were obtained binaurally from all subjects. Both groups were administered the frequency-pattern test (FPT) and duration-pattern test (DPT) monaurally (30 items per ear) in both the left and right ear. Gap detection results were obtained in both groups (binaural presentation) using narrowband noise centered at 1 kHz in an adaptive two-alternative forced-choice (2-AFC) paradigm. The FPT, DPT, and gap detection results were analyzed for interaural (where applicable), intergroup, and intragroup differences. Correlations between performance on the auditory tasks and the standardized tests of reading were examined. Additive logistic regression models were fit to the data to determine which auditory tests proved to be the best predictors of group membership. RESULTS: The persons with developmental dyslexia as a group performed significantly poorer than controls on both the FPT and DPT. Furthermore, the group differences were significant in both monaural conditions. On the FPT and DPT, five of the eleven participants with dyslexia performed below the widely used clinical criterion for APD of 70% correct in either ear. All five of these participants performed below criterion on the FPT, whereas four of the five additionally performed below 70% on the DPT. The data also were analyzed by fitting a series of stepwise logistic regression models, which indicated that gap detection did not significantly predict group membership, whereas the FPT and DPT were significant predictors. The addition of the FPT score after the DPT did not result in a significant change in the residual deviance. CONCLUSIONS: Approximately half of the participants with developmental dyslexia showed clinically significant diminished performance on the FPT and DPT indicative of APD. These results indicate that the percentage of persons with developmental dyslexia and comorbid APD may be substantial enough to warrant serious clinical considerations.

Acoustic Impedance Tests↗

Hearing loss, hearing handicap, and functional health status between African American and Caucasian American seniors.

This investigation examined the relations among hearing loss, handicap perception, and functional health status of 152 African American and Caucasian American seniors ranging in age from 60 to 89 years. Subjective measures were obtained from self-report scores on the Hearing Handicap Inventory for the Elderly (HHIE), the Medical Outcomes Study 36-Item Short Form Health Survey (SF-36), and demographic profiles. Results indicated the following: (1) both subject groups exhibited nearly identical degrees of sensorineural hearing loss consistent with presbyacusis; (2) African American seniors reported significantly lower levels of completed education than did Caucasian American seniors; (3) differences between groups in self-report scores of hearing handicap (HHIE) were not statistically significant; (4) differences across groups in self-report scores of functional health status (SF-36) were not statistically significant; and (5) increasing levels of hearing loss produced significantly higher HHIE scores and significantly lower SF-36 scores in each group. These findings are discussed.

Acoustic Impedance Tests↗