PubMed Health⌕ Search

Biomedical subjects

Carl R Fuhrman

Publications and source records attributed to Carl R Fuhrman.

15 recordsLinked to original sources

The prevalence effect in a laboratory environment: Changing the confidence ratings.

RATIONALE AND OBJECTIVES: We sought to assess whether or not prevalence levels affected the confidence ratings of readers during the interpretation of cases in a laboratory receiver operating characteristic-type observer performance study. MATERIALS AND METHODS: We reanalyzed a previously conducted observer performance study that included 14 readers and 5 different levels of prevalence. The previous study yielded the observation that in the laboratory we could not detect a "prevalence effect" in terms of differences in areas under the receiver operating characteristic curves. The detection ratings (for presence or absence) of lung nodules, interstitial disease, and pneumothorax for the five prevalence levels were compared, and a test for trend in averaged ratings as a function of abnormality prevalence was performed within a mixed-model setting that accounts for different sources of variability and correlations induced by the study design. RESULTS: The ratings of the cases in terms of confidence that the specific abnormality in question is present tend, on average, to be larger when actual disease prevalence is lower. The rate of the increase of the average confidence ratings with the decreasing prevalence of a specific abnormality is very similar for actually positive and actually negative cases for every considered abnormality. The observed trend in the changes of the average confidence ratings as a function of prevalence levels was statistically significant (p < 0.01). CONCLUSION: Expectations of disease prevalence in the case mix during a laboratory observer performance study may systematically affect the behavior of observers in terms of their actual confidence ratings.

Humans↗

Direct comparison of computed tomography and magnetic resonance imaging for characterization of posterior left atrial morphology.

OBJECTIVE: Accumulating evidence points to the central importance of the posterior left atrium (PLA) for atrial fibrillation (AF). Catheter ablation intended to cure AF is increasingly practiced; performance and assessment of this procedure is enhanced by accurate imaging of PLA anatomy. Prior reports have suggested that both computed tomographic (CT) and magnetic resonance (MR) imaging techniques provide accurate PLA images. These techniques have never been compared directly. MATERIALS AND METHODS: Twenty patients referred for catheter ablation underwent preoperative imaging using both CT and MR. Each technique was used to create a multidimensional image of the PLA. RESULTS: Within patients, morphologic and dimensional PLA indices, including number of individual pulmonary venoatrial junctions, presence of ostial branches, circumference of each venoatrial junction, venoatrial junction "non-circularity", and distance between ipsilateral superior and inferior venoatrial junctions, were well correlated. CONCLUSIONS: CT and MR-based images of the PLA appear comparable. Technique selection should involve considerations of toxicity, tolerance, and local resources.

Adult↗

Computerized estimation of the lung volume removed during lung volume reduction surgery.

RATIONALE AND OBJECTIVES: This study was designed to develop an automated method for estimating lung volume removed during lung volume reduction surgery (LVRS) using computed tomography (CT). MATERIALS AND METHODS: The CT examinations of six patients who underwent bilateral LVRS were analyzed in this study. The resected lung tissue (right and left) was weighed during pathologic examination. An automated computer scheme was developed to estimate the lung volume removed using the CT voxel values and lung specimen weight. The computed fraction of lung volume removed was evaluated across a range of simulated surgical planes (ie, other than parallel to the CT image plane) and CT reconstruction kernels, and it was compared with the surgeons' postsurgical estimates. RESULTS: The computed fraction of the lung volume removed during LVRS was linearly correlated with the resected lung tissue weight (Pearson correlation = 0.697, P = .012). The computed fraction of lung volume removed ranged from 12.9% to 51.7% of the total lung volume. The surgeons' postsurgical estimates of lung volume removed ranged from 30% to 33%. The percent difference between the surgeons' estimates and the computed lung volume removed as a percentage of the surgeons' estimates ranged from -72.3% to 57.0% with mean absolute difference of 29.7% (+/-20.7). CONCLUSION: The preliminary findings of this study suggest that the proposed quantitative model should provide an objective measure of lung volume removed during LVRS that may be used to investigate the relationship between lung volume removed and outcome.

Absorptiometry, Photon↗

Stereo CT image compositing methods for lung nodule detection and characterization.

RATIONALE AND OBJECTIVES: Stereographic display has been proposed as a possible method of improving performance in reading computed tomographic (CT) examinations acquired for lung cancer screening. Optimizing such displays is important given the large volume of image data that must be evaluated for each of these examinations. This study is designed to explore certain tradeoffs between rendering methods designed for the stereo display of CT images. MATERIALS AND METHODS: Stereo CT image compositing methods, including distance-weighted averaging, distance-weighted maximum intensity projection (MIP), and conventional MIP, were applied to lung CT images and compared for lung nodule detection and characterization. RESULTS: Using the Jonckheere test indicated a statistically significant (P < .01) increase in contrast among the three compositing methods. Wilcoxon-Mann-Whitney test showed significant differences in contrast between distance-weighted averaging and conventional MIP (P < .01) and between averaging and distance-weighted MIP (P < .05), but not between distance-weighted MIP and conventional MIP (P > .05). Conventional MIP compositing provided the highest image contrast, but produced ambiguities in local geometric detail and texture, whereas averaging resulted in the lowest contrast, but preserved geometric detail. Distance-weighted MIP partially recovered geometric information, which was lost in images composited by means of conventional MIP. CONCLUSION: Our results indicate that distance-weighted MIP may be a better choice for nodule detection in stereo lung CT images for its high local contrast and partial preservation of geometric information, whereas compositing by means of distance-weighted averaging is preferable for nodule characterization. The relative clinical value of these compositing methods needs to be evaluated further.

Algorithms↗

3D-multidetector CT angiography in the evaluation of potential donors for living donor lung transplantation.

INTRODUCTION: In living donor lung transplant, donor lobectomies from 2 donors provide right and left lower lobes for transplantation. In the past, routine evaluation of pulmonary anatomy was not performed preoperatively. Intraoperatively, surgeons were often forced to sacrifice the lingular artery or right middle lobe segmental artery to obtain an adequate arterial cuff for safe reimplantation. This study was performed to evaluate the utility of preoperative 3D-multidetector CT angiography (3D-MDCTA) as a noninvasive method of assessing pulmonary arteries to improve donor selection and surgical planning for living lung donors. SUBJECTS AND METHODS: Five potential lung donors for 2 recipients were included in the study. CT scanning with 4 channel multidetector-row CT was performed, using a modified pulmonary embolism protocol. Post-processing was performed using volume rendering techniques on a commercially available workstation. RESULTS: 3D-MDCT demonstrated that there are a number of variations in pulmonary arterial anatomy and that ideal anatomy was seldom encountered. Comparison of different donors determined which lower lobes were most favorable for transplantation. Surgery confirmed the accuracy of 3D-MDCTA. There were no pulmonary arterial complications, and no vessels were sacrificed. CONCLUSION: Safely explanting lower lobes from living donors for lung transplantation poses challenges not encountered in harvesting cadaveric donors or performing lobectomies for malignancy. 3D-MDCTA of pulmonary arteries can noninvasively delineate the often-complex pulmonary anatomy, which may assist in donor selection as well as reduce donor intraoperative and postoperative vascular complications.

Adult↗

Pulmonary nodule detection with low-dose CT of the lung: agreement among radiologists.

OBJECTIVE: The purpose of our study was to assess relative intra- and interobserver agreement in detecting pulmonary nodules when interpreting low-dose chest CT screening examinations. MATERIALS AND METHODS: Two hundred ninety-three selected low-dose CT examinations of the lung were independently interpreted by three radiologists to detect and classify pulmonary nodules. The data set selected was enriched with examinations depicting pulmonary nodules. A subset of 30 examinations was interpreted twice. All pulmonary nodules greater than 1.0 mm were marked. All nodules greater than 3.0 mm were marked, measured, and scored as to their probability of being benign or malignant. Nodule-based and examination-based relative reviewer agreements were evaluated using percentage of agreement and kappa statistics. Similar assessments were performed on the subset of examinations interpreted twice. RESULTS: The three radiologists identified a total of 470, 729, and 876 pulmonary nodules of which 395, 641, and 778 were rated as noncalcified with some level of suspicion for being malignant. Nodule-based interobserver agreement among the radiologists was poor (highest kappa value in a paired comparison, 0.120). Examination-based agreement was higher (highest kappa value in a paired comparison, 0.458). Intraobserver agreement was higher than interobserver agreement for examination-based agreement (highest kappa = 0.889) but lower for nodule-based agreement (highest kappa = -0.035). Agreement improved as the suspicion of malignancy increased. CONCLUSION: Unaided intra- and interobserver agreement in detecting pulmonary nodules in low-dose CT of the lung is relatively low. Computer-assisted detection may provide the consistency that is needed for this purpose.

Female↗

Incidental finding on MDCT of patent ductus arteriosus: use of CT and MRI to assess clinical importance.

OBJECTIVE: The purpose of this article is to describe the imaging features of patent ductus arteriosus (PDA) identified on chest MDCT performed for other indications and to describe the additional functional information that cardiac MRI can provide about these lesions. CONCLUSION: The daily use of MDCT studies for the evaluation of pulmonary embolic disease or aortic abnormalities can reveal incidental PDAs. Small incidental PDAs can be identified on chest MDCT angiography timed for either the pulmonary arteries or the aorta. Using multiplanar reformations, one can assess PDA location, caliber, length, and presence of calcifications. The presence of a "positive" or a "negative contrast jet" verifies a patent shunt. Cardiac MRI shows the detailed anatomic and morphologic features of a PDA. Hemodynamic information revealing the presence and severity of a significant shunt is obtainable using velocity-encoded MRI, allowing accurate shunt calculation. Using MDCT and MRI, information regarding the clinical significance of an incidental PDA can influence management decisions. The imaging information was used to determine that one PDA required intervention.

Aged↗

Non-cardiac findings on coronary electron beam computed tomography scanning.

The objective of this study was to estimate the prevalence and significance of non-cardiac findings on Electron Beam Computed Tomography (EBT) scanning when used in population screening for the quantitative measurement of coronary artery calcium and estimate of coronary risk. Clinic files of 1366 subjects who underwent EBT scanning between September 1996 and December 1998 at the University of Pittsburgh affiliated Comprehensive Heart Care Center were abstracted. The files of 1356 subjects contained the calcium score and non-cardiac findings as reported by board-certified radiologists, who interpreted the scans during the period 1996-1998. A National Death Index (NDI) Plus match was performed to ascertain cause of death. Two hundred seventy-eight of 1356 (20.5%) subjects had 1 or more non-cardiac findings on EBT scanning. Fifty-seven of 1356 (4.2%) received a recommendation for diagnostic CT follow-up. Forty-six of the 57 recommendations were for pulmonary nodules and 11 were for non-nodule, non-cardiac findings. Seven members of the cohort died during a short follow-up period. In 1 case, the non-cardiac finding was the cause of death. Non-cardiac findings in a healthy cohort referred for EBT coronary screening are relatively common. Findings range from clinically insignificant to the cause of death during a short follow-up period. EBT scanning is a frequently used coronary screening procedure. With the relatively high detection of significant, non-cardiac pathology in this increasingly common screening procedure, consideration should be given for radiologists to interpret the scans.

Adult↗

Intimomedial rupture: a new CT finding to distinguish true from false lumen in aortic dissection.

OBJECTIVE: The purpose of our study is to describe a new imaging finding observed on contrast-enhanced MDCT of discontinuity in the intimomedial flap seen with aortic dissection that may identify the level of intimomedial entrance tear and distinguish true from false lumen. CONCLUSION: Direct visualization of an intimomedial rupture on MDCT is a valuable cross-sectional imaging sign indicating direction of the intimomedial entrance tear from true to false lumen in cases of aortic dissection. The presence of this finding enables reliable distinction of the true lumen, where the tear is broad-based and erupts into the false lumen, which receives the evaginating tear. Improved scanning techniques through MDCT may have enabled recognition of this relatively infrequent, yet highly specific, finding.

Aged↗

Size and morphology of the trachea before and after lung volume reduction surgery.

OBJECTIVE: The purpose of this investigation was to determine the effect of lung volume reduction surgery on measured tracheal features. MATERIALS AND METHODS: Twenty-four male and 19 female patients with emphysema underwent lung volume reduction surgery, pulmonary function testing, and repeated CT. The tracheal air column was segmented from axial images. The sagittal and coronal dimensions of the intrathoracic trachea were determined. Tracheal morphology was quantified using the tracheal (coronal and sagittal dimensions) and circularity indexes. The results were compared with pulmonary function test results. RESULTS: Morphologic appearance of the intrathoracic trachea was consistent before and 3 months after surgery. The group means of the tracheal length, mean area, and volume were 78.60 mm (+/- 16.88 mm), 283.84 mm(2) (+/- 61.47 mm(2)), and 22.59 cm(3) (+/- 7.69 cm(3)), respectively, before surgery and 67.53 mm (+/- 15.78 mm), 309.12 mm(2) (+/- 79.83 mm(2)), and 20.99 cm(3) (+/- 7.27 cm(3)), respectively, after surgery (p < 0.05). Mean tracheal indexes were 0.85 (+/- 0.11) before surgery and 0.82 (+/- 0.04) after surgery (p < 0.01). Mean circularity indexes were 0.91 (+/- 0.03) before surgery and 0.90 (+/- 0.04) after surgery (p < 0.05). The size of the trachea was significantly correlated with lung volume before and after surgery (p < 0.05). The changes in tracheal features and changes in pulmonary function were not correlated (p > 0.05), except for tracheal area (p < 0.05). CONCLUSION: Our data suggest that tracheal dimensions reflect the severity of emphysema as reflected by increased lung volumes. Tracheal features were poor predictors of changes in postsurgical pulmonary function parameters evaluated in this preliminary study.

Female↗

Automated lung segmentation in X-ray computed tomography: development and evaluation of a heuristic threshold-based scheme.

RATIONALE AND OBJECTIVES: To develop and evaluate a reliable, fully-automated lung segmentation scheme for application in X-ray computed tomography. MATERIALS AND METHODS: The automated scheme was heuristically developed using a slice-based, pixel-value threshold and two sets of classification rules. Features used in the rules include size, circularity, and location. The segmentation scheme operates slice-by-slice and performs three key operations: (1) image preprocessing to remove background pixels, (2) computation and application of a pixel-value threshold to identify lung tissue, and (3) refinement of the initial segmented regions to prune incorrectly detected airways and separate fused right and left lungs. RESULTS: The performance of the automated segmentation scheme was evaluated using 101 computed tomography cases (91 thick slice, 10 thin slice scans). The 91 thick cases were pre- and post-surgery from 50 patients and were not independent. The automated scheme successfully segmented 94.0% of the 2,969 thick slice images and 97.6% of the 1,161 thin slice images. The mean difference of the total lung volumes calculated by the automated scheme and functional residual capacity plus 60% inspiratory capacity was -24.7 +/- 508.1 mL. The mean differences of the total lung volumes calculated by the automated scheme and an established, commonly used semi-automated scheme were 95.2 +/- 52.5 mL and -27.7 +/- 66.9 mL for the thick and thin slice cases, respectively. CONCLUSION: This simple, fully-automated lung segmentation scheme provides an objective tool to facilitate lung segmentation from computed tomography scans.

Image Processing, Computer-Assisted↗

Prevalence effect in a laboratory environment.

PURPOSE: To measure observer performance at various levels of prevalence. MATERIALS AND METHODS: A multiobserver multiabnormality receiver operating characteristic (ROC) study to assess the effect of prevalence on observer performance was conducted. Fourteen observers, including eight faculty members, two fellows, and four residents, interpreted 1,632 posteroanterior chest images with five prevalence levels by using a nested study design. Performance comparisons were accomplished by using a multireader multicase approach to assess the effect of prevalence from 28% (69 of 249) to 2% (31 of 1,577) on diagnostic accuracy. The mean times required to review and report a case were analyzed and compared for different levels of prevalence and readers' experience. RESULTS: Area under the ROC curve demonstrated that, with the study experimental conditions, no significant effect could be measured as a function of prevalence (P >.05) for any abnormality, group of cases, or readers. There were no significant differences (P >.05) in the mean times required to review and report cases at different prevalence levels and with different groups of readers. CONCLUSION: The consistency in the results and the size of this study suggest that with laboratory conditions, if a prevalence effect exists, it is quite small in magnitude; hence, it will not likely alter conclusions derived from such studies.

Laboratories↗

Observer performance studies: detection of single versus multiple abnormalities of the chest.

OBJECTIVE: We used receiver operating characteristic (ROC) analysis to compare two methods of evaluating observer performance in detecting an abnormality on chest radiographs. In the first method, the abnormality in question, rib fracture, was one of five investigated, and it was the only one of interest in the second. MATERIALS AND METHODS: Eight experienced observers viewed 117 posteroanterior chest radiographs in two interpretation modes. Fifty-four of these images depicted rib fractures that had been rated as subtle for detection. The likelihood of the presence of a rib fracture was rated as one of five abnormalities in question in one mode and the sole abnormality of interest in the other mode. RESULTS: Six of the observers performed better during the single-abnormality mode, one performed equally well in both modes, and one performed better during the multiple-abnormality mode. The average area under the ROC curves (A(z)) was 0.73 +/- 0.07 for the multiple-abnormality mode and 0.80 +/- 0.04 for the single-abnormality mode. The results were significantly different (p < 0.05). CONCLUSION: Study methodology can significantly affect the results in ROC studies, particularly for abnormalities that may not be perceived as primary or important. The order in which abnormalities appear on a checklist report form may be important.

Area Under Curve↗