PubMed Health⌕ Search

Biomedical subjects

Carl T Wittwer

Publications and source records attributed to Carl T Wittwer.

At least 19 recordsLinked to original sources

Solution-phase DNA mutation scanning and SNP genotyping by nanoliter melting analysis.

Solution-phase, DNA melting analysis for heterozygote scanning and single nucleotide polymorphism (SNP) genotyping was performed in 10 nl volumes on a custom microchip. Human genomic DNA was PCR amplified in the presence of the saturating fluorescent dye, LCGreen Plus, and placed within microfluidic channels that were created between two glass slides. The microchip was heated at 0.1 degrees C/s with a Peltier device and viewed with an inverted fluorescence microscope modified for photomulitiplier tube detection. The melting data was normalized and the negative first derivative plotted against temperature. Mutation scanning for heterozygotes was easily performed by comparing the shape of the melting curve to homozygous standards. Genotyping of homozygotes by melting temperature (T(m)) required absolute temperature comparisons. Mutation scanning of ATM exon 17 and CFTR exon 10 identified single base change heterozygotes in 84 and 201 base-pair (bp) products, respectively. All genotypes at HFE C282Y were distinguished by simple melting analysis of a 40-bp fragment. Sequential analysis of the same sample on the gold-standard, commercial high-resolution melting instrument HR-1, followed by melting in a 10 nl reaction chamber, produced similar results. DNA melting analysis requires only minutes after PCR and is a simple method for genotyping and scanning that can be reduced to nanoliter volumes. Microscale systems for performing DNA melting reduce the reagents/DNA template required with a promise for high throughput analysis in a closed chamber without risk of contamination.

DNA↗

Amplicon DNA melting analysis for mutation scanning and genotyping: cross-platform comparison of instruments and dyes.

BACKGROUND: DNA melting analysis for genotyping and mutation scanning of PCR products by use of high-resolution instruments with special "saturation" dyes has recently been reported. The comparative performance of other instruments and dyes has not been evaluated. METHODS: A 110-bp fragment of the beta-globin gene including the sickle cell anemia locus (A17T) was amplified by PCR in the presence of either the saturating DNA dye, LCGreen Plus, or SYBR Green I. Amplicons of 3 different genotypes (wild-type, heterozygous, and homozygous mutants) were melted on 9 different instruments (ABI 7000 and 7900HT, Bio-Rad iCycler, Cepheid SmartCycler, Corbett Rotor-Gene 3000, Idaho Technology HR-1 and LightScanner, and the Roche LightCycler 1.2 and LightCycler 2.0) at a rate of 0.1 degrees C/s or as recommended by the manufacturer. The ability of each instrument/dye combination to genotype by melting temperature (Tm) and to scan for heterozygotes by curve shape was evaluated. RESULTS: Resolution varied greatly among instruments with a 15-fold difference in Tm SD (0.018 to 0.274 degrees C) and a 19-fold (LCGreen Plus) or 33-fold (SYBR Green I) difference in the signal-to-noise ratio. These factors limit the ability of most instruments to accurately genotype single-nucleotide polymorphisms by amplicon melting. Plate instruments (96-well) showed the greatest variance with spatial differences across the plates. Either SYBR Green I or LCGreen Plus could be used for genotyping by T(m), but only LCGreen Plus was useful for heterozygote scanning. However, LCGreen Plus could not be used on instruments with an argon laser because of spectral mismatch. All instruments compatible with LCGreen Plus were able to detect heterozygotes by altered melting curve shape. However, instruments specifically designed for high-resolution melting displayed the least variation, suggesting better scanning sensitivity and specificity. CONCLUSION: Different instruments and dyes vary widely in their ability to genotype homozygous variants and scan for heterozygotes by whole-amplicon melting analysis.

Benzothiazoles↗

Masking selected sequence variation by incorporating mismatches into melting analysis probes.

Hybridization probe melting analysis can be complicated by the presence of sequence variation (benign polymorphisms or other mutations) near the targeted mutation. We investigated the use of "masking" probes to differentiate alleles with similar probe melting temperatures. Selected sequence variation was masked by incorporating mismatches (deletion, unmatched nucleotide, or universal base) into hybridization probes at the polymorphic location. Such masking probes create a probe/target mismatch with all possible alleles at the selected polymorphic location. Any allele with additional variation at another site is identified by a lower probe melting temperature than alleles that vary only at the masked position. This "masking technique" was applied to RET protooncogene and HPA6 mutation detection using unlabeled hybridization probes, a saturating dsDNA dye, and high-resolution melting analysis. Masking probes clearly distinguished all targeted mutations from polymorphisms when at least 1 base pair (bp) separated the mutation from the masked variation. We were able to mask polymorphisms immediately adjacent to mutations, except in certain cases, such as those involving single-base deletion probes when both adjacent positions had the same polymorphic nucleotides. The masking probes can also localize mutations to specific codons or nucleotide positions. Masking probes can simplify melting analysis of complex regions and eliminate the need for sequencing.

Alleles↗

Mutation scanning of the RET protooncogene using high-resolution melting analysis.

BACKGROUND: Single-base pair missense mutations in exons 10, 11, 13, 14, 15, and 16 of the RET protooncogene are associated with the autosomal dominant multiple endocrine neoplasia type 2 (MEN2) syndromes: MEN2A, MEN2B, and familial medullary thyroid carcinoma. The current widely used approach for RET mutation detection is sequencing of the exons. METHODS: Because RET mutations are rare and the majority are heterozygous mutations, we investigated RET mutation detection by high-resolution amplicon melting analysis. This mutation scanning technique uses a saturating double-stranded nucleic acid binding dye, LCGreen, and the high-resolution melter, HR-1, to detect heterozygous and homozygous sequence variations. Mutant genotypes are distinguished from the wild-type genotype by an altered amplicon melting curve shape or position. RESULTS: Samples of 26 unique RET mutations, 4 nonpathogenic polymorphisms, or the wild-type genotype were available for this study. The developed RET mutation-scanning assay differentiated RET sequence variations from the wild-type genotype by altered derivative melting curve shape or position. A blinded study of 80 samples (derived from the 35 mutant, polymorphism, or wild-type samples) demonstrated that 100% of RET sequence variations were differentiated from wild-type samples. For exons 11 and 13, the nonpathogenic polymorphisms could be distinguished from the pathogenic RET mutations. Some RET mutations could be directly genotyped by the mutation scanning assay because of unique derivative melting curve shapes. CONCLUSION: RET high-resolution amplicon melting analysis is a sensitive, closed-tube assay that can detect RET protooncogene sequence variations.

Genotype↗

Real-time polymerase chain reaction and melting curve analysis.

Monitoring polymerase chain reaction (PCR) once each cycle is a powerful method to detect and quantify the presence of nucleic acid sequences and has become known as "real-time" PCR. Absolute quantification of initial template copy number can be obtained, although quantification relative to a control sample or second sequence is often adequate. Melting analysis following PCR monitors duplex hybridization as the temperature is changed and is a simple method for sequence verification and genotyping. Melting analysis is often conveniently performed immediately after PCR in the same reaction tube. The fluorescence of either DNA dyes that are specific to double-strands or fluorescently labeled oligonucleotide probes can be monitored for both real-time quantification and melting analysis. When used together with rapid temperature control, these methods allow amplification and genotyping in less than a half hour.

DNA↗

Evaluation of Her-2/neu gene status in osteosarcoma by fluorescence in situ hybridization and multiplex and monoplex polymerase chain reactions.

CONTEXT: Previous reports suggest that the human epidermal growth factor 2 (HER-2/neu) receptor may be overexpressed in osteosarcoma. OBJECTIVE: To determine whether osteosarcomas have amplifications of the HER-2/neu gene. DESIGN: We studied a series of osteosarcomas by fluorescence in situ hybridization (FISH) and by 2 real-time polymerase chain reaction assays that measure the amount of HER-2/neu DNA relative to a control gene. The HER-2/ neu monoplex and multiplex assays were capable of identifying those cases of breast cancer that were known to overexpress HER-2/neu as assessed by FISH. We initially studied 21 cases of osteosarcoma by FISH analysis (using a technique that included a probe for chromosome 17), 11 of which had their HER-2/neu gene amplification status previously reported. RESULTS: None of these osteosarcoma cases showed HER-2/neu amplification by our FISH analysis and subsequent quantitative (multiplex) polymerase chain reaction. Apparent expression of HER-2/neu protein was observed in several of the cases but the immunoreactivity was localized to the cytoplasm and was not membranous in character. An additional 35 osteosarcoma specimens were subjected to monoplex polymerase chain reaction analysis, and amplifiable DNA was recovered from 19 specimens (54%). None of these samples had HER-2/neu amplification by monoplex PCR analysis and only one case had membranous immunoreactivity graded as 1+. CONCLUSION: Although a small subset of osteosarcomas had weak noncircumferential membranous immunoreactivity for HER-2/neu protein, no osteosarcomas demonstrated positive (2+ or 3+) immunoreactivity for HER-2/ neu protein and none showed HER-2/neu gene amplification by either FISH or polymerase chain reaction.

Bone Neoplasms↗

Molecular classification of melanoma using real-time quantitative reverse transcriptase-polymerase chain reaction.

BACKGROUND: The early detection and characterization of metastatic melanoma are important for prognosis and management of the disease. Molecular methods are more sensitive in detecting occult lymph node metastases compared with standard histopathology and are reported to have utility in clinical diagnostics. METHODS: Using real-time quantitative reverse transcriptase-polymerase chain reaction ([q]RT-PCR), the authors examined 36 samples (30 melanomas, 4 benign nevi, and 2 reactive lymph nodes) for the expression of 20 melanoma-related genes that function in cell growth and differentiation (epidermal growth factor receptor [EGFR], WNT5A, BRAF, FOS, JUN, MATP, and TMP1), cell proliferation (KI-67, TOP2A, BUB1, BIRC5, and STK6), melanoma progression (CD63, MAGEA3, and GALGT), and melanin synthesis (TYR, MLANA, SILV, PAX3, and MITF). In addition, samples were tested for mutations in BRAF (exons 11 and 15) and NRAS (exons 2 and 3). RESULTS: Hierarchical clustering analysis of the expression data was able to distinguish between the melanoma and nonmelanoma samples and further stratified the melanoma samples into two groups differentiated by high expression of the genes involved in beta-catenin activation (EGFR and WNT5A) and the MAPK/ERK pathway (BRAF, FOS, and JUN). Eighteen of the 28 patients (64%) were found to have mutations in either exon 15 of BRAF (V599 substitution) or codon 61 of NRAS. The mutations were mutually exclusive and did not appear to be associated with the different expression subtypes. CONCLUSIONS: The results of the current study demonstrate that real-time qRT-PCR can be analyzed using hierarchical clustering to identify expression patterns that differentiate between melanomas and other tissue types. Using a supervised analysis of the data, the authors found that the best discriminators for molecularly distinguishing between melanoma, benign nevi, and lymph nodes were MLANA, CD63, and BUB1. These markers could have diagnostic utility for the detection of melanoma micrometastasis in sentinel lymph nodes.

Biomarkers, Tumor↗

Quantitative heteroduplex analysis for single nucleotide polymorphism genotyping.

High-resolution melting of polymerase chain reaction (PCR) products can detect heterozygous mutations and most homozygous mutations without electrophoretic or chromatographic separations. However, some homozygous single nucleotide polymorphism (SNPs) have melting curves identical to that of the wild-type, as predicted by nearest neighbor thermodynamic models. In these cases, if DNA of a known reference genotype is added to each unknown before PCR, quantitative heteroduplex analysis can differentiate heterozygous, homozygous, and wild-type genotypes if the fraction of reference DNA is chosen carefully. Theoretical calculations suggest that melting curve separation is proportional to heteroduplex content difference and that the addition of reference homozygous DNA at one seventh of total DNA results in the best discrimination between the three genotypes of biallelic SNPs. This theory was verified experimentally by quantitative analysis of both high-resolution melting and temperature-gradient capillary electrophoresis data. Reference genotype proportions other than one seventh of total DNA were suboptimal and failed to distinguish some genotypes. Optimal mixing before PCR followed by high-resolution melting analysis permits genotyping of all SNPs with a single closed-tube analysis.

Electrophoresis, Capillary↗

A comparison of high-resolution melting analysis with denaturing high-performance liquid chromatography for mutation scanning: cystic fibrosis transmembrane conductance regulator gene as a model.

High-resolution melting analysis (HRMA) was compared with denaturing high-performance liquid chromatography (dHPLC) for mutation scanning of common mutations in the cystic fibrosis transmembrane conductance regulator gene. We amplified (polymerase chain reaction under conditions optimized for melting analysis or dHPLC) 26 previously genotyped samples with mutations in exons 3, 4, 7, 9, 10, 11, 13, 17b, and 21, including 20 different genotypes. Heterozygous mutations were detected by a change in shape of the melting curve or dHPLC tracing. All 20 samples with heterozygous mutations studied by both techniques were identified correctly by melting (100% sensitivity), and 19 were identified by dHPLC (95% sensitivity). The specificity of both methods also was good, although the dHPLC traces of exon 7 consistently revealed 2 peaks for wild-type samples, risking false-positive interpretation. Homozygous mutations could not be detected using curve shape by either method. However, when the absolute temperatures of HRMA were considered, G542X but not F508del homozygotes could be distinguished from wild type. HRMA easily detected heterozygotes in all single nucleotide polymorphism (SNP) classes (including A/T SNPs) and 1- or 2-base-pair deletions. HRMA had better sensitivity and specificity than dHPLC with the added advantage that some homozygous sequence alterations could be identified. HRMA has great potential for rapid, closed-tube mutation scanning.

Chromatography, High Pressure Liquid↗

Rapid species identification within the Mycobacterium chelonae-abscessus group by high-resolution melting analysis of hsp65 PCR products.

Polymerase chain reaction (PCR) amplification of the heat shock protein 65 (hsp65) gene followed by high-resolution melting analysis with LCGreen I (Idaho Technology, Salt Lake City, UT) was used to differentiate the mycobacteria species Mycobacterium chelonae, Mycobacterium abscessus, and Mycobacterium immunogenum in less than 20 minutes. A 105-base-pair amplicon that clustered the different species by predicted melting temperature was found from available GenBank hsp65 sequences. We identified 24 clinical isolates within the M chelonae-abscessus group by proximal 16S ribosomal RNA and hsp65 gene sequencing. Rapid-cycle PCR followed by high-resolution melting analysis clustered these samples into the following groups: M abscessus, 12; M abscessus sequence variant, 2; M chelonae, 7; unexpected M chelonae sequence variant, 1; and M immunogenum, 2. The M chelonae variant had a single base change not found in reported GenBank sequences. Advantages of the method include speed, low risk of amplicon contamination (closed-tube), and no need for separation steps (sequencing, electrophoresis, high-performance liquid chromatography) or real-time monitoring.

Bacterial Proteins↗

High-resolution DNA melting analysis for simultaneous mutation scanning and genotyping in solution.

BACKGROUND: High-resolution DNA melting analysis with saturation dyes for either mutation scanning of PCR products or genotyping with unlabeled probes has been reported. However, simultaneous PCR product scanning and probe genotyping in the same reaction has not been described. METHODS: Asymmetric PCR was performed in the presence of unlabeled oligonucleotide probes and a saturating fluorescent DNA dye. High-resolution melting curves for samples in either capillaries (0.3 degrees C/s) or microtiter format (0.1 degrees C/s) were generated in the same containers used for amplification. Melting curves of the factor V Leiden single-nucleotide polymorphism (SNP) and several mutations in exons 10 and 11 of the cystic fibrosis transconductance regulator gene were analyzed for both PCR product and probe melting transitions. RESULTS: Independent verification of genotype for simple SNPs was achieved by either PCR product or probe melting transitions. Two unlabeled probes in one reaction could genotype many sequence variants with simultaneous scanning of the entire PCR product. For example, analysis of both product and probe melting transitions genotyped DeltaF508, DeltaI507, Q493X, I506V, and F508C variants in exon 10 and G551D, G542X, and R553X variants in exon 11. Unbiased hierarchal clustering of the melting transitions identified the specific sequence variants. CONCLUSIONS: When DNA melting is performed rapidly and observed at high resolution with saturating DNA dyes, it is possible to scan for mutations and genotype at the same time within a few minutes after amplification. The method is no more complex than PCR and may reduce the need for resequencing.

DNA↗

Sensitivity and specificity of single-nucleotide polymorphism scanning by high-resolution melting analysis.

BACKGROUND: Screening for heterozygous sequence changes in PCR products, also known as "mutation scanning", is an important tool for genetic research and clinical applications. Conventional methods require a separation step. METHODS: We evaluated the sensitivity and specificity of homogeneous scanning, using a saturating DNA dye and high-resolution melting. Heterozygous single-nucleotide polymorphism (SNP) detection was studied in three different sequence backgrounds of 40%, 50%, and 60% GC content. PCR products of 50-1000 bp were generated in the presence of LCGreen I. After fluorescence normalization and temperature overlay, melting curve shape was used to judge the presence or absence of heterozygotes among 1632 cases. RESULTS: For PCR products of 300 bp or less, all 280 heterozygous and 296 wild-type cases were correctly called without error. In 672 cases between 400 and 1000 bp with the mutation centered, the sensitivity and specificity were 96.1% and 99.4%, respectively. When the sequence background and product size with the greatest error rate were used, the sensitivity of off-center SNPs (384 cases) was 95.6% with a specificity of 99.4%. Most false negatives occurred with SNPs that were compared with an A or T wild type sequence. CONCLUSIONS: High-resolution melting analysis with the dye LCGreen I identifies heterozygous single-base changes in PCR products with a sensitivity and specificity comparable or superior to nonhomogeneous techniques. The error rate of scanning depends on the PCR product size and the type of base change, but not on the position of the SNP. The technique requires only PCR reagents, the dye LCGreen I, and 1-2 min of closed-tube, post-PCR analysis.

DNA↗

Single-tube method for nucleic acid extraction, amplification, purification, and sequencing.

BACKGROUND: The hepatitis C virus (HCV) genotype determines patient prognosis and duration of treatment, but sequencing of the gene is lengthy and labor-intensive. We used a commercially available nucleic acid extraction system to develop a single-tube extraction-to-sequencing (STETS) method for HCV genotyping. METHODS: HCV RNA was purified and amplified in tubes coated with a solid-phase matrix that irreversibly bound nucleic acid during the extraction step. After reverse transcription-PCR, the amplicon was adsorbed to the original extraction matrix for purification and use in the subsequent sequencing reactions. RESULTS: The STETS method generated genotyping-quality sequence for a range of HCV titers from 500 to 6,000,000 IU/mL. If a viral sample was detected during real-time reverse transcription-PCR, it could be sequenced and genotyped. Read lengths >600 bases were observed with the STETS method. Mixed infections were detected and genotyped if at least 15% of the minor species was present. Combining the STETS method with consecutive sequencing provided a means of performing both forward and reverse sequencing in a single tube. CONCLUSIONS: A single-tube nucleic acid extraction-to-sequencing method, which requires less time and labor than conventional methods, generates HCV sequence data that are equivalent to conventional methods and can be used to genotype HCV.

Genotype↗