PubMed Health⌕ Search

Biomedical subjects

Carl Wittwer

Publications and source records attributed to Carl Wittwer.

6 recordsLinked to original sources

Molecular basis of clonal expansion of hematopoiesis in 2 patients with paroxysmal nocturnal hemoglobinuria (PNH).

Somatic mutation of PIGA in hematopoietic stem cells causes deficiency of glycosyl phosphatidylinositol-anchored proteins in paroxysmal nocturnal hemoglobinuria (PNH) that underlies the intravascular hemolysis but does not account for expansion of the PNH clone. Immune mechanisms may mediate clonal selection but appear insufficient to account for the clonal dominance necessary for PNH to become clinically apparent. Herein, we report 2 patients with PNH whose PIGA-mutant cells had a concurrent, acquired rearrangement of chromosome 12. In both cases, der(12) had a break within the 3' untranslated region of HMGA2, the architectural transcription factor gene deregulated in many benign mesenchymal tumors, that caused ectopic expression of HMGA2 in the bone marrow. These observations suggest that aberrant HMGA2 expression, in concert with mutant PIGA, accounts for clonal hematopoiesis in these 2 patients and suggest the concept of PNH as a benign tumor of the bone marrow.

Biomarkers, Tumor↗

Genotyping of human platelet antigens 1 to 6 and 15 by high-resolution amplicon melting and conventional hybridization probes.

High-resolution melting techniques are a simple and cost-effective alternative to other closed-tube genotyping methods. Here, we genotyped human platelet antigens (HPAs) 1 to 6 and 15 by high-resolution melting methods that did not require labeled probes. Conventional melting analysis with hybridization probes (HybProbes) was also performed at each locus. HybProbe assays were performed individually, whereas amplicon melting (HPAs 1 to 5 and 16) and unlabeled probe (HPA 6) assays were duplexed when possible. At all loci for each method, both homozygous and heterozygous genotypes were easily identified. We analyzed 100 blinded clinical samples (33 amniotic fluid, 12 cultured amniocytes, and 55 blood samples) for all 7 single-nucleotide polymorphisms (SNPs) by each method. Genotype assignments could be made in 99.0% of the SNPs by high-resolution melting and in 98.7% of the SNPs with HybProbes with an overall genotype concordance of 98.8%. Errors included two sample misidentifications and six incorrect assignments that were all resolved by repeating the analysis. Advantages of high-resolution melting include rapid assay development and execution, no need for modified oligonucleotides, and similar accuracy in genotyping compared with other closed-tube melting methods.

Antigens, Human Platelet↗

HLA-B27 typing: evaluation of an allele-specific PCR melting assay and two flow cytometric antigen assays.

BACKGROUND: Human leukocyte antigen B27 (HLA-B27) is a major histocompatibility complex class 1 molecule that is strongly associated with the disease ankylosing spondylitis. Testing for HLA-B27 is of diagnostic value because 90% of patients with ankylosing spondylitis have the B27 antigen. Two commonly used HLA-B27 flow cytometric assays are commercially available. METHODS: An allele-specific polymerase chain reaction (PCR) melting assay for HLA-B27 was compared with two available antigen assays on 371 clinical samples. The accuracy of the assays was measured by receiver operating characteristic analysis using the PCR method and sequencing as the reference standard. RESULTS: When PCR results were compared with those of the antigen assays, complete concordance was observed except for five discrepant results that were resolved by sequence analysis. Using DNA sequencing as the gold standard, the sensitivity and specificity of PCR were 99.6 and 100.0, those of the best single antigen assay were 98.2 and 97.6, and those of a reflex combination of both antigen assays were 98.8 and 97.6. CONCLUSIONS: The allele-specific PCR melting assay for HLA-B27 genotyping is easy to perform and has better sensitivity and specificity than antigen assays. The performance of the two flow cytometric antigen assays depends on the antibody used and the positive cutoff values assigned.

Alleles↗

Hepatitis C genotyping by denaturing high-performance liquid chromatography.

Determination of the hepatitis C virus (HCV) genotype for infected patients increasingly has become accepted as the standard of care. Genotype assignment helps in assessing disease prognosis and assists in establishing the appropriate duration of treatment. The great genetic diversity of HCV, with 11 major genotypes and >70 subtypes, contributes to the technical difficulty of genotype testing. While the "gold standard" for testing is nucleic acid sequencing, a variety of hybridization assays, including the line probe assay, have been developed to provide more rapid and accessible forms of testing. The aim of this study was to determine whether denaturing high-performance liquid chromatography (dHPLC) could be used as a clinical method for distinguishing HCV genotypes 1, 2, 3, and 4. A portion of the 5' untranslated region of the HCV genome was amplified by heminested multiplex reverse transcription PCR. The two amplicons then were analyzed by dHPLC analysis and compared to the genotypes determined by sequence analysis. After 115 specimens were analyzed as standards, 200 masked specimens (specimens whose identity was not known before testing) were analyzed to determine the concordance of the assay. The assay had a concordance of 96% at the genotype level and a concordance of 87% at the subtype level. However, the dHPLC method was not as accurate as other reported methods of HCV genotyping. This is the first time that HCV genotyping has been performed by dHPLC.

5' Untranslated Regions↗

Genotyping of single-nucleotide polymorphisms by high-resolution melting of small amplicons.

BACKGROUND: High-resolution melting of PCR amplicons with the DNA dye LCGreen I was recently introduced as a homogeneous, closed-tube method of genotyping that does not require probes or real-time PCR. We adapted this system to genotype single-nucleotide polymorphisms (SNPs) after rapid-cycle PCR (12 min) of small amplicons (</=50 bp). METHODS: Engineered plasmids were used to study all possible SNP base changes. In addition, clinical protocols for factor V (Leiden) 1691G>A, prothrombin 20210G>A, methylenetetrahydrofolate reductase (MTHFR) 1298A>C, hemochromatosis (HFE) 187C>G, and beta-globin (hemoglobin S) 17A>T were developed. LCGreen I was included in the reaction mixture before PCR, and high-resolution melting was obtained within 2 min after amplification. RESULTS: In all cases, heterozygotes were easily identified because heteroduplexes altered the shape of the melting curves. Approximately 84% of human SNPs involve a base exchange between A::T and G::C base pairs, and the homozygotes are easily genotyped by melting temperatures (T(m)s) that differ by 0.8-1.4 degrees C. However, in approximately 16% of SNPs, the bases only switch strands and preserve the base pair, producing very small T(m) differences between homozygotes (<0.4 degrees C). Although most of these cases can be genotyped by T(m), one-fourth (4% of total SNPs) show nearest-neighbor symmetry, and, as predicted, the homozygotes cannot be resolved from each other. In these cases, adding 15% of a known homozygous genotype to unknown samples allows melting curve separation of all three genotypes. This approach was used for the HFE 187C>G protocol, but, as predicted from the sequence changes, was not needed for the other four clinical protocols. CONCLUSIONS: SNP genotyping by high-resolution melting analysis is simple, rapid, and inexpensive, requiring only PCR, a DNA dye, and melting instrumentation. The method is closed-tube, performed without probes or real-time PCR, and can be completed in less than 2 min after completion of PCR.

Factor V↗

Evaluation of electronic microarrays for genotyping factor V, factor II, and MTHFR.

BACKGROUND: Genetic risk factors associated with venous thrombosis include mutations in the factor V (Leiden), factor II (prothrombin), and methylenetetrahydrofolate reductase (MTHFR) genes. We evaluated a method using electronically addressable microarrays for the detection of mutations in these genes that have been associated with vascular disease. METHODS: The NanoChip Molecular Biology Workstation (Nanogen) uses electronic microarrays for mutation detection. Factor V, factor II, and MTHFR genotypes identified in the NanoChip system on 225 samples were compared with genotypes from LightCycler assays (Roche). We determined within- and between-cartridge signal and ratio variation and analyzed the effect of additional mutations at or near the detection area used for the NanoChip assays. RESULTS: Genotypes determined for all three mutations on the NanoChip platform were in complete concordance with LightCycler results. Within-cartridge signal variation as measured by the CV of fluorescence signals was <10% for each allele when present. The within-cartridge CV for heterozygous mutant/wild-type ratios was <8.5%, and between-cartridge CV was <18%. A dilution study showed that results could be obtained in this assay with 6 ng of nucleic acid per PCR, the lowest input tested. The presence of additional sequence variations near the expected mutations can produce equivocal or discrepant results. CONCLUSIONS: Mutation detection using the NanoChip Molecular Biology Workstation was accurate and reproducible for the three assays evaluated.

Electronics↗