Carlijn V C Bouten

Publications and source records attributed to Carlijn V C Bouten.

At least 19 recordsLinked to original sources

The relative contributions of compression and hypoxia to development of muscle tissue damage: an in vitro study.

Deep pressure ulcers develop in tissues subjected to sustained mechanical loading. Though it has been hypothesized that this damage mechanism results from local tissue ischemia, it has recently been shown with a cell model that sustained compression can cause cell deformation, leading to tissue breakdown. The present study focuses on the assessment of cell viability during compression and ischemia in an in vitro muscle model to determine their relative contributions to damage development. A model system was developed consisting of engineered skeletal muscle produced from the culture of murine muscle cells in a collagen gel. The tissue was subjected to 0, 20, or 40% compression under hypoxic or normoxic conditions. Experiments were performed on the stage of a microscope and cell viability was monitored using fluorescent markers for apoptotic and necrotic cell death. Hypoxia did not lead to significant cell death over a 22 h period. By contrast, compression led to immediate cell death that increased with time. No additional effect of hypoxia on cell death was observed. These data show that contrary to existing theories, compression can cause development of muscle damage and that hypoxia does not contribute to cell death development within 22 h in engineered muscle.

Animals↗

Autologous human tissue-engineered heart valves: prospects for systemic application.

BACKGROUND: Tissue engineering represents a promising approach for the development of living heart valve replacements. In vivo animal studies of tissue-engineered autologous heart valves have focused on pulmonary valve replacements, leaving the challenge to tissue engineer heart valves suitable for systemic application using human cells. METHODS AND RESULTS: Tissue-engineered human heart valves were analyzed up to 4 weeks and conditioning using bioreactors was compared with static culturing. Tissue formation and mechanical properties increased with time and when using conditioning. Organization of the tissue, in terms of anisotropic properties, increased when conditioning was dynamic in nature. Exposure of the valves to physiological aortic valve flow demonstrated proper opening motion. Closure dynamics were suboptimal, most likely caused by the lower degree of anisotropy when compared with native aortic valve leaflets. CONCLUSIONS: This study presents autologous tissue-engineered heart valves based on human saphenous vein cells and a rapid degrading synthetic scaffold. Tissue properties and mechanical behavior might allow for use as living aortic valve replacements.

Absorbable Implants↗

Modeling the mechanics of tissue-engineered human heart valve leaflets.

Mathematical models can provide valuable information to assess and evaluate the mechanical behavior of tissue-engineered constructs. In this study, a structurally based model is applied to describe and analyze the mechanics of tissue-engineered human heart valve leaflets. The results from two orthogonal uniaxial tensile tests are used to determine the model parameters of the constructs after two, three and four weeks of culturing. Subsequently, finite element analyses are performed to simulate the mechanical response of the engineered leaflets to a pressure load. The stresses in the leaflets induced by the pressure load increase monotonically with culture time due to a decrease in the construct's thickness. The strains, on the other hand, eventually decrease as a result of an increase in the elastic modulus. Compared to native porcine leaflets, the mechanical response of the engineered tissues after four weeks of culturing is more linear, stiffer and less anisotropic.

Biomechanical Phenomena↗

An in vitro model system to study the damaging effects of prolonged mechanical loading of the epidermis.

Pressure ulcers are areas of soft tissue breakdown that result from sustained mechanical loading of the skin and underlying tissues. Today, little is known with respect to the aetiology of these ulcers. This study introduces an in vitro model system to study the effects of clinically relevant loading regimes on damage progression in the epidermis, the uppermost skin layer. Engineered epidermal equivalents (EpiDerm) were subjected to 6.7 and 13.3 kPa for either 2 or 20 h using a custom-built loading device. Tissue damage was assessed by (1) histological examination, (2) tissue viability evaluation, and (3) by the release of a pro-inflammatory mediator, interleukin-1alpha (IL-1alpha). Loading the EpiDerm samples for 2 h increased the IL-1alpha release, although no visible tissue damage was observed. However, in the 20 h loading experiments visible tissue damage and a small decrease in tissue viability were observed. Furthermore, in these experiments the IL-1alpha release increased with magnitude of loading. It is concluded that this in vitro model system can be applied to improve insight in the epidermal damage process due to prolonged mechanical loading and can serve as a sound basis for effective clinical identification and prevention of pressure ulcers.

Epidermis↗

Fluorescently labeled collagen binding proteins allow specific visualization of collagen in tissues and live cell culture.

Visualization of the formation and orientation of collagen fibers in tissue engineering experiments is crucial for understanding the factors that determine the mechanical properties of tissues. In this study, collagen-specific fluorescent probes were developed using a new approach that takes advantage of the inherent specificity of collagen binding protein domains present in bacterial adhesion proteins (CNA35) and integrins (GST-alpha1I). Both collagen binding domains were obtained as fusion proteins from an Escherichia coli expression system and fluorescently labeled using either amine-reactive succinimide (CNA35) or cysteine-reactive maleimide (GST-alpha1I) dyes. Solid-phase binding assays showed that both protein-based probes are much more specific than dichlorotriazinyl aminofluorescein (DTAF), a fluorescent dye that is currently used to track collagen formation in tissue engineering experiments. The CNA35 probe showed a higher affinity for human collagen type I than did the GST-alpha1I probe (apparent K(d) values of 0.5 and 50 microM, respectively) and showed very little cross-reactivity with noncollagenous extracellular matrix proteins. The CNA35 probe was also superior to both GST-alpha1I and DTAF in visualizing the formation of collagen fibers around live human venous saphena cells. Immunohistological experiments on rat tissue showed colocalization of the CNA35 probe with collagen type I and type III antibodies. The fluorescent probes described here have important advantages over existing methods for visualization of collagen, in particular for monitoring the formation of collagen in live tissue cultures over prolonged time periods.

Adhesins, Bacterial↗

Mechanical characterization of anisotropic planar biological soft tissues using large indentation: a computational feasibility study.

Traditionally, the complex mechanical behavior of planar soft biological tissues is characterized by (multi)axial tensile testing. While uniaxial tests do not provide sufficient information for a full characterization of the material anisotropy, biaxial tensile tests are difficult to perform and tethering effects limit the analyses to a small central portion of the test sample. In both cases, determination of local mechanical properties is not trivial. Local mechanical characterization may be performed by indentation testing. Conventional indentation tests, however, often assume linear elastic and isotropic material properties, and therefore these tests are of limited use in characterizing the nonlinear, anisotropic material behavior typical for planar soft biological tissues. In this study, a spherical indentation experiment assuming large deformations is proposed. A finite element model of the aortic valve leaflet demonstrates that combining force and deformation gradient data, one single indentation test provides sufficient information to characterize the local material behavior. Parameter estimation is used to fit the computational model to simulated experimental data. The aortic valve leaflet is chosen as a typical example. However, the proposed method is expected to apply for the mechanical characterization of planar soft biological materials in general.

Animals↗

Tissue engineering of human heart valve leaflets: a novel bioreactor for a strain-based conditioning approach.

Current mechanical conditioning approaches for heart valve tissue engineering concentrate on mimicking the opening and closing behavior of the leaflets, either or not in combination with tissue straining. This study describes a novel approach by mimicking only the diastolic phase of the cardiac cycle, resulting in tissue straining. A novel, yet simplified, bioreactor system was developed for this purpose by applying a dynamic pressure difference over a closed tissue engineered valve, thereby inducing dynamic strains within the leaflets. Besides the use of dynamic strains, the developing leaflet tissues were exposed to pre-strain induced by the use of a stented geometry. To demonstrate the feasibility of this strain-based conditioning approach, human heart valve leaflets were engineered and their mechanical behavior evaluated. The actual dynamic strain magnitude in the leaflets over time was estimated using numerical analyses. Preliminary results showed superior tissue formation and non-linear tissue-like mechanical properties in the strained valves when compared to non-loaded tissue strips. In conclusion, the strain-based conditioning approach, using both pre-strain and dynamic strains, offers new possibilities for bioreactor design and optimization of tissue properties towards a tissue-engineered aortic human heart valve replacement.

Aortic Valve↗

Fibrin as a cell carrier in cardiovascular tissue engineering applications.

In cardiovascular tissue engineering approaches, efficient seeding methods are essential. To achieve this and to save time, cells can be encapsulated in gels. Combining the advantages of a gel as a cell carrier with the advantages of a fiber-based scaffold, providing structural integrity to the developing tissue, might offer several advantages. In this study, seeding by using fibrin as a cell carrier is compared to the conventional static seeding method with regard to tissue development. Seeding with fibrin resulted in less loss of soluble collagen into the medium and a more mature extracellular matrix in a shorter period of time. The use of fibrin degradation inhibitors was shown to inhibit extracellular matrix formation, although it did not hamper cell proliferation. The use of fibrin as a cell carrier to seed cells into a fiber-based scaffold may represent a promising, timesaving approach in cardiovascular tissue engineering applications.

Biocompatible Materials↗

Improved prediction of the collagen fiber architecture in the aortic heart valve.

Living tissues show an adaptive response to mechanical loading by changing their internal structure and morphology. Understanding this response is essential for successful tissue engineering of load-bearing structures, such as the aortic valve. In this study, mechanically induced remodeling of the collagen architecture in the aortic valve was investigated. It was hypothesized that, in uniaxially loaded regions, the fibers aligned with the tensile principal stretch direction. For biaxial loading conditions, on the other hand, it was assumed that the collagen fibers aligned with directions situated between the principal stretch directions. This hypothesis has already been applied successfully to study collagen remodeling in arteries. The predicted fiber architecture represented a branching network and resembled the macroscopically visible collagen bundles in the native leaflet. In addition, the complex biaxial mechanical behavior of the native valve could be simulated qualitatively with the predicted fiber directions. The results of the present model might be used to gain further insight into the response of tissue engineered constructs during mechanical conditioning.

Animals↗

Viscoelastic properties of single attached cells under compression.

The viscoelastic properties of single, attached C2C12 myoblasts were measured using a recently developed cell loading device. The device allows global compression of an attached cell, while simultaneously measuring the associated forces. The viscoelastic properties were examined by performing a series of dynamic experiments over two frequency decades (0.1-10 Hz) and at a range of axial strains (approximately 10-40%). Confocal laser scanning microscopy was used to visualize the cell during these experiments. To analyze the experimentally obtained force-deformation curves, a nonlinear viscoelastic model was developed. The nonlinear viscoelastic model was able to describe the complete series of dynamic experiments using only a single set of parameters, yielding an elastic modulus of 2120 +/- 900 Pa for the elastic spring, an elastic modulus of 1960 +/- 1350 for the nonlinear spring, and a relaxation time constant of 0.3 +/- 0.12 s. To our knowledge, it is the first time that the global viscoelastic properties of attached cells have been quantified over such a wide range of strains. Furthermore, the experiments were performed under optimal environmental conditions and the results are, therefore, believed to reflect the viscoelastic mechanical behavior of cells, such as would be present in vivo.

Animals↗

A structural constitutive model for collagenous cardiovascular tissues incorporating the angular fiber distribution.

Accurate constitutive models are required to gain further insight into the mechanical behavior of cardiovascular tissues. In this study, a structural constitutive framework for cardiovascular tissues is introduced that accounts for the angular distribution of collagen fibers. To demonstrate its capabilities, the model is applied to study the biaxial behavior of the arterial wall and the aortic valve. The pressure-radius relationships of the arterial wall accurately describe experimentally observed sigma-shaped curves. In addition, the nonlinear and anisotropic mechanical properties of the aortic valve can be analyzed with the proposed model. We expect that the current model offers strong possibilities to further investigate the complex mechanical behavior of cardiovascular tissues, including their response to mechanical stimuli.

Algorithms↗

Decreased mechanical stiffness in LMNA-/- cells is caused by defective nucleo-cytoskeletal integrity: implications for the development of laminopathies.

Laminopathies comprise a group of inherited diseases with variable clinical phenotypes, caused by mutations in the lamin A/C gene (LMNA). A prominent feature in several of these diseases is muscle wasting, as seen in Emery-Dreifuss muscle dystrophy, dilated cardiomyopathy and limb-girdle muscular dystrophy. Although the mechanisms underlying this phenotype remain largely obscure, two major working hypotheses are currently being investigated, namely, defects in gene regulation and/or abnormalities in nuclear architecture causing cellular fragility. In this study, using a newly developed cell compression device we have tested the latter hypothesis. The device allows controlled application of mechanical load onto single living cells, with simultaneous visualization of cellular deformation and quantitation of resistance. With the device, we have compared wild-type (MEF+/+) and LMNA knockout (MEF-/-) mouse embryonic fibroblasts (MEFs), and found that MEF-/- cells show a significantly decreased mechanical stiffness and a significantly lower bursting force. Partial rescue of the phenotype by transfection with either lamin A or lamin C prevented gross nuclear disruption, as seen in MEF-/- cells, but was unable to fully restore mechanical stiffness in these cells. Our studies show a direct correlation between absence of LMNA proteins and nuclear fragility in living cells. Simultaneous recordings by confocal microscopy revealed that the nuclei in MEF-/- cells, in contrast to MEF+/+ cells, exhibited an isotropic deformation upon indentation, despite an anisotropic deformation of the cell as a whole. This nuclear behaviour is indicative for a loss of interaction of the disturbed nucleus with the surrounding cytoskeleton. In addition, careful investigation of the three-dimensional organization of actin-, vimentin- and tubulin-based filaments showed a disturbed interaction of these structures in MEF-/- cells. Therefore, we suggest that in addition to the loss of nuclear stiffness, the loss of a physical interaction between nuclear structures (i.e. lamins) and the cytoskeleton is causing more general cellular weakness and emphasizes a potential key function for lamins in maintaining cellular tensegrity.

Actins↗

Anisotropic, three-dimensional deformation of single attached cells under compression.

Quantifying three-dimensional deformation of cells under mechanical load is relevant when studying cell deformation in relation to cellular functioning. Because most cells are anchorage dependent for normal functioning, it is desired to study cells in their attached configuration. This study reports new three-dimensional morphometric measurements of cell deformation during stepwise compression experiments with a recently developed cell loading device. The device allows global, unconfined compression of individual, attached cells under optimal environmental conditions. Three-dimensional images of fluorescently stained myoblasts were recorded with confocal microscopy and analyzed with image restoration and three-dimensional image reconstruction software to quantify cell deformation. In response to compression, cell width, cross-sectional area, and surface area increased significantly with applied strain, whereas cell volume remained constant. Interestingly, the cell and the nucleus deformed perpendicular to the direction of actin filaments present along the long axis of the cell. This strongly suggests that this anisotropic deformation can be attributed to the preferred orientation of actin filaments. A shape factor was introduced to quantify the global shape of attached cells. The increase of this factor during compression reflected the anisotropic deformation of the cell.

Animals↗

Review article: Tissue engineering of semilunar heart valves: current status and future developments.

Heart valve replacement represents the most common surgical therapy for end-stage valvular heart diseases. One major drawback that all heart valve replacements have in common is the lack of growth, repair, and remodeling capability once implanted into the body. The emerging field of tissue engineering is focusing on the in-vitro generation of functional, living semilunar heart valve replacements. This review presents a state-of-the-art overview of the physiological and biomechanical requirements of semilunar heart valves, focusing on the aortic valve. Moreover, recent heart valve tissue engineering is summarized and future options and improvements on the way towards clinical applications are discussed.

Animals↗

Centrifuges and inertial shear forces.

Centrifuges are often used in biological studies for 1 x g control samples in space flight microgravity experiments as well as in ground based research. Using centrifugation as a tool to generate an Earth like acceleration introduces unwanted inertial shear forces to the sample. Depending on the centrifuge and the geometry of the experiment hardware used these shear forces may contribute as much as 99% to the total force acting on the cells or tissues. The inertial shear force artifact should be dealt with for future experiment hardware development for Shuttle and the International Space Station (ISS) as well as for the interpretation of previous spaceflight and on-ground research data.

Cell Adhesion↗

Monitoring local cell viability in engineered tissues: a fast, quantitative, and nondestructive approach.

Assessment of cell viability is a key issue in monitoring in vitro engineered tissue constructs. In this study we describe a fully automated, quantitative, and nondestructive approach, which is particularly suitable for tissue engineering. The approach offers several advantages above existing methods. Living and dead cell numbers can be separately determined for both isolated cells and cells that form networks during tissue formation. Moreover, viability can be locally monitored in time throughout the three-dimensional tissue. The viability assay is based on a dual fluorescent staining technique using CellTracker Green (CTG) for detection of living cells and propidium iodide (PI) for dead cells. CTG and PI images are created with a confocal laser scanning microscope. To determine the number of living cells, CTG fluorescence intensity is determined from the CTG image. Thereby, novel image-processing techniques have been developed, normalizing for various undesired influences that alter measurements of absolute CTG fluorescence intensities. Dead cell numbers are determined from the PI image, using an improved computerized counting method. The approach was first evaluated on C2C12 monolayers, of which images were taken directly after probe addition and 24 h later. Results show that at both times, computed living and dead cell numbers highly correlate with manually counted cell numbers (r > 0.996). Next, the approach was applied for monitoring viability in three-dimensional engineered skeletal muscle tissue constructs, which were subjected to unfavorable environmental conditions. This example illustrated that local viability can be quantitatively, nondestructively, and locally monitored in three-dimensional tissue constructs, making it a promising tool in the field of tissue engineering.

Animals↗

Finite element model of mechanically induced collagen fiber synthesis and degradation in the aortic valve.

Tissue-engineered trileaflet aortic valves are a promising alternative to current valve replacements. However, the mechanical properties of these valves are insufficient for implantation at the aortic position. To simulate the effect of collagen remodeling on the mechanical properties of the aortic valve, a finite element model is presented. In this study collagen remodeling is assumed to be the net result of collagen synthesis and degradation. A limited number of fibers with low initial fiber volume fraction is defined, and depending on the loading condition, the fibers are either synthesized or degraded. The synthesis and degradation of collagen fibers are both assumed to be functions of individual fiber stretch and fiber volume fraction. Simulations are performed for closed aortic valve configurations and the open aortic valve configuration. The predicted fiber directions for the closed configurations are close to the fiber directions as measured in the native aortic valve. The model predicts the evolution in collagen fiber content and the effect of remodeling on the mechanical properties.

Anisotropy↗

In vitro models to study compressive strain-induced muscle cell damage.

Skeletal muscle tissue is highly susceptible to sustained compressive straining, eventually leading to tissue breakdown in the form of pressure sores. This breakdown begins at the cellular level and is believed to be triggered by sustained cell deformation. To study the relationship between compressive strain-induced muscle cell deformation and damage, and to investigate the role of cell-cell interactions, cell-matrix interactions and tissue geometry in this process, in vitro models of single cells, monolayers and 3D tissue analogs under compression are being developed. Compression is induced using specially designed loading devices, while cell deformation is visualised with confocal microscopy. Cell damage is assessed from viability tests, vital microscopy and histological or biochemical analyses. Preliminary results from a 3D cell seeded agarose model indicate that cell deformation is indeed an important trigger for cell damage; sustained compression of the model at 20% strain results in a significant increase in cell damage with time of compression, whereas damage in unstrained controls remains constant over time.