Images in cardiovascular medicine. Bilateral carotid body tumor evaluated by three-dimensional multislice computed tomography angiography.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Carlo Catalano.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
BACKGROUND AND AIMS: We prospectively compared the performance of low-dose multidetector computed tomographic colonography (CTC) without cathartic preparation with that of colonoscopy for the detection of colorectal polyps. METHODS: A total of 203 patients underwent low-dose CTC without cathartic preparation followed by colonoscopy. Before CTC, fecal tagging was achieved by adding diatrizoate meglumine and diatrizoate sodium to regular meals. No subtraction of tagged feces was performed. Colonoscopy was performed 3-7 days after CTC. Three readers interpreted the CTC examinations separately and independently using a primary 2-dimensional approach using multiplanar reconstructions and 3-dimensional images for further characterization. Colonoscopy with segmental unblinding was used as reference standard. The sensitivity of CTC was calculated both on a per-polyp and a per-patient basis. For the latter, specificity, positive predictive values, and negative predictive values were also calculated. RESULTS: CTC had an average sensitivity of 95.5% (95% confidence interval [CI], 92.1%-99%) for the identification of colorectal polyps > or =8 mm. With regard to per-patient analysis, CTC yielded an average sensitivity of 89.9% (95% CI, 86%-93.7%), an average specificity of 92.2% (95% CI, 89.5%-94.9%), an average positive predictive value of 88% (95% CI, 83.3%-91.5%), and an average negative predictive value of 93.5% (95% CI, 90.9%-96%). Interobserver agreement was high on a per-polyp basis (kappa statistic range, .61-.74) and high to excellent on a per-patient basis (kappa statistic range, .79-.91). CONCLUSIONS: Low-dose multidetector CTC without cathartic preparation compares favorably with colonoscopy for the detection of colorectal polyps.
PURPOSE: To compare multi-detector row spiral computed tomographic (CT) angiography with digital subtraction angiography (DSA) in evaluation of the infrarenal aorta and lower-extremity arterial system. MATERIALS AND METHODS: Fifty patients with peripheral arterial occlusive disease were evaluated with multi-detector row CT angiography and DSA. Arteries depicted at CT angiography and DSA were graded separately for degree of stenosis as 23 anatomic segments (infrarenal aorta, right and left common iliac artery, internal iliac artery, external iliac artery, common femoral artery, superficial femoral artery, deep femoral artery, popliteal artery, anterior tibial artery, tibioperoneal trunk, posterior tibial artery, and peroneal artery). Grades included the following: 1, normal patency; 2, moderate (< or =50%) stenosis; 3, focal severe (>50%) stenosis; 4, multiple severe stenoses; and 5, occlusion. Three readers independently interpreted the images, and statistical analysis was performed. The results of image interpretation were evaluated for strength of agreement by using Cohen kappa statistics. On the basis of consensus readings, sensitivity, specificity, and accuracy for detection of stenotic lesions were calculated, with findings at DSA used as the reference standard. RESULTS: Substantial to almost perfect interobserver agreement was achieved in all cases. At DSA, 349 diseased segments were found among the 1,137 segments evaluated. Sensitivity, specificity, and accuracy, based on a consensus reading of multi-detector row CT angiograms, were 96%, 93%, and 94%, respectively. A statistically significant difference (P <.05) between DSA and multi-detector row CT angiography was present only in arteries graded 1 or 2. Interobserver agreement was almost perfect among the three readers for treatment recommendations based on findings at CT angiography and DSA. CONCLUSION: Multi-detector row CT angiography appears consistent and accurate in the assessment of patients with peripheral arterial occlusive disease.
PURPOSE: To prospectively evaluate multi-detector row spiral computed tomography (CT) for determination of splenic volume, splenic vascular anatomy, and presence of accessory spleens and parenchymal lesions in patients who were undergoing laparoscopic splenectomy. MATERIALS AND METHODS: Twenty-two patients who were candidates for laparoscopic splenectomy underwent multiphasic multi-detector row CT. Two observers evaluated splenic volume with two hand-tracing editing modalities. Variability between the two observers was calculated with a reliability coefficient (Cronbach alpha). A linear regression equation for each modality was generated to identify the correlation between the two observers. Multi-detector row CT angiography was evaluated for assessment of splenic vascular anatomy. Presence and number of both accessory spleens and parenchymal lesions were recorded. RESULTS: Mean splenic volume was 1,050 and 1,046 mL, respectively, for observers A and B by using each-section editing (technique 1) and 1,067 and 1,068 mL for observers A and B by using distanced editing (technique 2). For each editing modality, alpha reliability coefficient was higher than 0.99. Both techniques 1 and 2 were very highly predictive of specimen weight and had R2 values of greater than 0.99 (P <.001). CT angiograms correctly showed polar arteries in all cases and the presence of the arteria pancreatica magna in one case. Multi-detector row CT demonstrated the presence, number, and size of all accessory spleens and of focal parenchymal lesions. CONCLUSION: Multi-detector row CT volumetric and anatomic evaluation provided accurate and reproducible information.
Imaging of the cirrhotic patient is a very difficult task due to the several morphologic and structural alterations that occur in the hepatic parenchyma. The presence of areas of fibrosis and regenerative nodules, often associated with haemodynamic alterations due to the portal hypertension, can make the identification of hepatocellular carcinoma very difficult or, in many cases, simulate the presence of tumour. Despite the use of state-of-the-art equipment and optimised study protocols, computed tomography (CT) has poor sensitivity for the detection of hepatocellular carcinoma. The present article illustrates the spiral CT findings that most often can be found in the evaluation of cirrhotic patients. In particular, the authors illustrate the CT patterns of regenerative nodules, dysplastic nodules, hepatocellular carcinomas and of all lesions that may mimic hepatocellular carcinoma.
Over the past decades, the feasibility of non-invasive coronary imaging has been explored using different modalities, such as magnetic resonance and electron beam computed tomography. Despite encouraging initial results, neither technique is yet considered suitable for routine clinical use. Recent developments in multidetector computed tomography have expanded the potential of contrast-enhanced spiral computed tomography coronary angiography. Promising results have been published with the use of 4-slice spiral computed tomography; however, cardiac motion and calcium deposits in the artery wall rendered a substantial number of scans inadequate for interpretation. Recently, a new generation of scanners, equipped with more and thinner detector rows (8 and 16 detectors) and an increased rotation speed, have been introduced. These technical advances will have a significant impact on cardiac imaging: at an increased gantry rotation rate, up to 32 slices can be acquired in 1 s. The improved spatial and temporal resolutions have led to the opportunity of acquiring high-quality images of the entire heart within a single breath-hold.
Explore the source record for details and available documents.
BACKGROUND: A reduction in salivary and lacrimal secretion has been described in several diseases. However, such alterations have not been investigated fully in patients with chronic renal failure. The aim of the present study is to estimate the frequency of alterations in salivary and lacrimal secretion in long-term hemodialysis patients. METHODS: Sixty-three hemodialysis patients and 23 healthy control subjects were studied. In all of them, we tested salivary secretion (Saxon's test), lacrimal secretion (Shirmer's test), and the presence of xerostomia and xerophthalmia symptoms. In a subgroup of patients, we performed other tests to evaluate evidence of ocular lesions and tissue damage to salivary glands. We also tested the relationship between salivary and lacrimal secretion and autonomic nervous system function. RESULTS: On average, salivary and lacrimal secretion were markedly reduced in uremic patients compared with healthy controls, and alterations in salivary gland function were related strongly to salivary gland fibrosis and atrophy. Xerophthalmia often was asymptomatic, but frequently was associated with corneal lesions. Xerostomia and xerophthalmia were unrelated to autonomic dysfunction and hepatitis C virus infection. CONCLUSION: A reduction in lacrimal and salivary secretion is frequent in long-term dialysis patients. Such alterations often are asymptomatic and could be the expression of acceleration of an age-dependent decline in glandular function and attendant fibrosis and atrophy.
Explore the source record for details and available documents.
PURPOSE: To compare the performance of lower-dose multi-detector row helical computed tomographic (CT) colonography with that of conventional colonoscopy in the detection of colorectal lesions. MATERIALS AND METHODS: One hundred fifty-eight patients underwent multi-detector row helical CT colonography (beam collimation, 4 x 2.5 mm; table feed, 17.5 mm/sec; voltage, 140 kV; and effective dose, 10 mAs) followed by conventional colonoscopy. Conventional colonoscopy served as the reference standard. Two radiologists interpreted CT colonographic images to assess the presence of polyps or carcinomas. Sensitivity was calculated on both a per-polyp and a per-patient basis. In the latter, specificity and positive and negative predictive values were also calculated. Weighted CT dose index was calculated on the basis of measurements obtained in a standard body phantom. Effective dose was estimated by using commercially available software. RESULTS: CT colonography correctly depicted all 22 carcinomas (sensitivity, 100%) and 52 of 74 polyps (sensitivity, 70.3%). Sensitivity for detection was 100% in all 13 polyps 10 mm or larger in diameter, 83.3% in 20 of 24 polyps 6-9 mm, and 51.3% in 19 of 37 lesions 5 mm or smaller. With regard to the per-patient analysis, CT colonography had a sensitivity of 96.0%, a specificity of 96.6%, a positive predictive value of 94.1%, and a negative predictive value of 97.7%. The total weighted CT dose index for combined prone and supine acquisitions was 2.74 mGy. The simulated effective doses for complete CT colonography were 1.8 mSv in men and 2.4 mSv in women. CONCLUSION: Lower-dose multi-detector row helical CT colonography ensures substantial dose reduction while maintaining excellent sensitivity for detection of colorectal carcinomas and polyps larger than 6 mm in diameter.
OBJECTIVE: The purpose of our report is to describe morphologic abnormalities of the small bowel in a population of patients with known celiac disease using MR imaging with polyethylene glycol solution as an oral contrast agent. CONCLUSION: Polyethylene glycol-enhanced MR imaging is a noninvasive (no ionizing radiation is used), feasible, and reproducible imaging technique in both adult and pediatric populations. Findings on polyethylene glycol-enhanced MR imaging, similar to those of conventional barium studies, may suggest a diagnosis of celiac disease because the technique can not only reveal intestinal involvement but also show extraintestinal findings.
Explore the source record for details and available documents.
Our objective was to evaluate the feasibility of ultra-low-dose scanning for multislice CT colonography in the detection of colorectal lesions. Twenty-seven patients (14 men, 13 women) with clinical indication for conventional colonoscopy were recruited. Multislice spiral CT (Somatom Plus 4 Volume Zoom, Siemens, Germany) examinations were performed after standard oral colonoscopic preparation and colonic distension with room air. Images were acquired using 2.5-mm collimation, 3.0-mm slice thickness, standard reconstruction kernel, 140 kVp, and 10 mAs. Supine and prone acquisitions were obtained in all patients. Images were analyzed on a workstation by two gastrointestinal radiologists. Conventional colonoscopy was performed on the same day in all patients and represented the standard of reference. Total radiation exposure was also calculated. All colorectal cancers were correctly identified at CT colonography (9 of 9, sensitivity 100%). The CT colonography also detected 10 of 12 polyps (overall sensitivity 83.3%). Based on polyp diameter, the sensitivity for the detection of polyps 10 mm or larger was 100% (3 of 3); between 6 and 9 mm, 100% (3 of 3); and 5 mm or smaller, 66.6% (4 of 6). Total radiation exposure for prone and supine acquisitions combined was 1.7 mSv (for men) and 2.3 mSv (for women). Although preliminary, our experience suggests that ultra-low-dose scanning for multislice CT colonography is feasible. This technique provides a sensitivity comparable to that of previous experiences with CT colonography but with a 40-70% reduction of the radiation dose delivered to patients.
The purpose of our study was to evaluate multislice computed tomography (MSCT) in the assessment of patients with clinical, laboratory, and US suspicion of pancreatic neoplasm, and to evaluate resectability status. Forty-six patients with a suspected pancreatic tumor underwent MSCT. After a preliminary precontrast survey, a postcontrast scan was performed in the arterial and portal venous phase with the following protocol: 4 x 1-mm collimation; 1.25- and 5-mm slice thickness width, respectively, and 1- and 5-mm reconstruction interval. In all patients pathological correlation was obtained. The evaluation of all images provided a diagnosis in 44 patients, with a sensitivity, specificity, and accuracy of 97, 80, and 96%, respectively. The MSCT correctly provided a diagnosis of unresectability with sensitivity of 96%, specificity of 86%, and accuracy of 93%. Evaluation of 1-mm slices demonstrated 83 of the 91 liver metastases found at surgery; conversely, the 5-mm slices detected only 76 of these lesions. Infiltration of peripancreatic major vessels was demonstrated, and was confirmed at surgery in 18 patients. High-resolution MSCT improves prediction of resectability in patients with suspected pancreatic carcinoma. Parenchymal and vascular information can be achieved with a single MSCT examination.
BACKGROUND: The aim of our study was to compare the performance of virtual computed tomographic colonography with that of conventional colonoscopy in a blinded, prospective study in 165 patients with suspected colorectal lesions. METHODS: There were 165 patients, all referred for conventional colonoscopy, who underwent preliminary virtual computed tomographic colonography. Computed tomograhic images of all suspected lesions were analyzed and subsequently compared with conventional colonoscopy findings. RESULTS: There were 30 colorectal cancers and 37 polyps identified at conventional colonoscopy. Virtual computed tomographic colonography correctly detected all cancers, as well as 11 of 12 polyps of 10 mm in diameter or larger (sensitivity, 92%); 14 of 17 polyps between 6 and 9 mm (sensitivity, 82%); and 4 of 8 polyps of 5 mm or smaller (sensitivity, 50%). The per-patient sensitivity and specificity were 92% and 97%, respectively. CONCLUSIONS: Virtual computed tomographic colonography has a diagnostic sensitivity similar to that of conventional colonoscopy for the detection of colorectal lesions larger than 6 mm in diameter.
Explore the source record for details and available documents.
Nephrolithiasis is a rare finding in kidney transplantation and anuria could be the only clinical sign. We report the case of a 52-year-old Caucasian male renal transplant recipient admitted due to acute renal failure (ARF) and anuria. He reported no symptoms and a palpable bulge in the right iliac fossa corresponding to the graft was present. Ultrasonography showed hydronephrosis of the graft. A double-J ureteral stent was inserted with resolution of ARF. ARF with anuria and the presence of a palpable non-tender, elastic mass over the graft could be the clinical picture of obstructive ARF in a transplanted kidney.