PubMed Health⌕ Search

Biomedical subjects

Carlo Prati

Publications and source records attributed to Carlo Prati.

At least 19 recordsLinked to original sources

Polymerization kinetics of dental adhesives cured with LED: correlation between extent of conversion and permeability.

OBJECTIVES: The aim of this study was to analyze the polymerization kinetics of different adhesive films in relation to their permeability after exposure to different LED curing units. METHODS: One adhesive from each class was analyzed: a three-step etch-and-rinse (OptiBond FL; Sybron-Kerr), a two-step etch-and-rinse (One-Step, Bisco), a two-step self-etch (Clearfil Protect Bond, Kuraray) and a one-step self-etch adhesive (Xeno III; Dentsply DeTrey). Adhesive films were prepared and cured with SmartLite IQ (Dentsply) or L.E. Demetron I (Demetron Kerr) up to complete curing. Polymerization kinetic curves of the tested adhesives were obtained with differential scanning calorimetry (DSC). In particular, total reaction time and extent of polymerization (Ep) at 20, 40 or 60s were compared. Permeability of the adhesive films was evaluated on flat dentin surfaces of human extracted teeth connected to a permeability device and statistically analyzed. RESULTS: Total reaction time differed among the adhesives tested: OptiBond FL<Clearfil Protect Bond<One-Step<Xeno III with both curing units (p<0.05). At 20s OptiBond FL showed the highest Ep, while the lowest values were obtained with One-Step and Xeno III (p<0.05). E(p) increased when curing time was prolonged (40 and 60s) for all adhesives tested (p<0.05), however, on simplified adhesives, incomplete polymerization took place even after prolonged exposure intervals. An inverse correlation was found between Ep of the adhesives and their permeability using LED curing units. SIGNIFICANCE: This study supports the hypothesis that, longer curing times than those recommended by the respective manufacturer decrease permeability of the bonded interfaces.

Adhesives↗

Effects of citric acid and EDTA conditioning on exposed root dentin: An immunohistochemical analysis of collagen and proteoglycans.

OBJECTIVE: Preservation of structural and biochemical properties of the root dentin matrix is crucial to favor healing and regenerative periodontal processes. Aim of this study was to evaluate the biochemical characteristics of collagen and chondroitin sulphate of root dentin surfaces exposed by periodontal disease after acid conditioning by means of an immunohistochemical technique. DESIGN: Human teeth scheduled for extraction due to periodontal reason were submitted to: (A) scaling and root planning; (B) ultrasonic instrumentation; (C) no instrumentation. Teeth were then exposed to: (1) 10% citric acid; (2) 17% EDTA; (3) no etching. A double immunolabeling technique was performed to identify type-I collagen and proteoglycans and analyzed under FEI-SEM. RESULTS: Use of 10% citric acid revealed intense labeling for collagen fibrils and proteoglycans; lower labeling was found after EDTA conditioning. Unetched specimens showed residual smear layer on the dentin surface resulting in no evident surface labeling. CONCLUSIONS: This study supports the hypothesis that manual or ultrasonic instrumentation alone is not able to expose the sound dentin matrix, whereas a subsequent acidic conditioning exposes collagen fibrils and associated proteoglycans. The immunohistochemical technique revealed that despite their acidity, both citric acid and EDTA were able to preserve the structural and biochemical properties of the exposed dentin matrix.

Acid Etching, Dental↗

Effect of simulated pulpal pressure on dentin permeability and adhesion of self-etch adhesives.

OBJECTIVES: Dentin bonds made with one-bottle etch-and-rinse and self-etch adhesives are affected by the formation of interfacial blisters, porosities and deterioration. The first objective of this study was to evaluate the fluid flow through resin-dentin interfaces created by self-etching adhesives applied to deep dentin using a replica technique and by directly measuring dentin permeability (P). The second objective was to examine the effect of intrapulpal pressure on the microtensile bond strength of these adhesives. METHODS: A fluid-transport model was used to measure the fluid permeability (%P) through different adhesives. Impressions of bonded dentin were taken with a polyvinylsiloxane impression material to monitor fluid transudation from the surface of the adhesive. Positive replicas were fabricated for SEM examination. Two groups of resin-bonded specimens (pulpal pressure versus no pulpal pressure) were created for microtensile bond strength evaluation. Adhesive application was performed under 0 cm H(2)O. Pulpal pressure group was submitted to 20 cm H(2)O of pulpal pressure during build-up procedures. RESULTS: Clearfil Protect Bond exhibited the lowest permeability and fewest numbers of fluid droplets over the surface of the bonded dentin. G-Bond and Clearfil-S3 Bond were more permeable than Clearfil Protect Bond. One Up Bond F was the most permeable adhesive. A highly significant correlation was observed between the relative permeability of these adhesives (%P) and the number of fluid droplets on the adhesive surfaces. The application of pulpal pressure significantly reduced bond strength. SIGNIFICANCE: Resin-dentin bonds created by contemporary self-etch adhesives are susceptible to fluid permeation induced by pulpal pressure. HEMA-based adhesives showed the largest reductions in bond strengths after pulpal pressure application.

Acid Etching, Dental↗

Oxalate-containing phytocomplexes as dentine desensitisers: an in vitro study.

It is known that pulpal fluid movement through dentinal tubules causes dentinal hypersensitivity and that pain can be reduced by decreasing the fluid flow. The aim of this study was to evaluate dentinal permeability and morphology after a single exposure to experimental phytocomplex substances containing oxalates. The treatments tested were experimental pastes, gels and solutions of phytocomplexes (extracted from rhubarb, spinach and mint), an experimental paste containing 5% potassium oxalate, and two commercial toothpastes recommended for dentinal hypersensitivity (Elmex and Sensodyne). Dentine discs from human third molars were used in this study. Each sample was brushed for 3 min with each treatment in order to test reductions in dentinal permeability. Each treated sample was challenged with orthophosphoric acid for 90 s to determine changes in dentinal permeability and the sensitivity of treatments to acid challenge. Scanning electron microscopy was used to analyse the samples. This study found that spinach and rhubarb phytocomplex treatments reduced dentinal permeability by occluding dentinal tubules through formation of calcium oxalate crystals. These results indicate that phytocomplexes extracted from rhubarb and spinach, used in different formulations, should be effective for topical treatment of dentinal hypersensitivity.

Amines↗

Merkel cells in the oral mucosa.

Ninety-eight consecutive surgical biopsies of oral mucosa from 96 patients were evaluated immunohistochemically with an anti-cytokeratin 20 (CK 20) anti-body to evidence Merkel cells (MC). Fifteen cases, showing the highest number of MC, were additionally studied with chromogranin A, S-100 protein, neuro filaments, epithelial membrane antigen, and double immunostaining for CK 20 and Ki67 antibodies to evaluate MC proliferation. Electron microscopy was performed in 2 cases. MC were observed in 58 cases. The highest number of MC was found in the gingival, buccal, and palate mucosa, especially in chronically damaged oral mucosa (lichen and chronic aspecific inflammation) as well as in the mucosa overlying tumors rather than in normal or acute inflammation. MC were not observed in dysplastic or neoplastic epithelium. MC showed evidence of proliferation, as demonstrated by Ki67 positivity, in 3 cases. In conclusion, MC appear to play a role in the reparative processes of oral mucosa.

Adolescent↗

Water uptake of bonding systems applied on root dentin surfaces: a SEM and confocal microscopic study.

OBJECTIVES: Dentin adhesives have been proposed as desensitizing agents to seal exposed root dentin surfaces. Simplified 'one-step' dentin adhesives are highly permeable to water. The authors hypothesized that a lactic acid challenge may increase permeability of simplified adhesives and may induce fast degradation of bonding. This phenomenon adversely affects their durability as long term desensitizing agents. The aim of this in vitro study was to evaluate the ability of four dentin adhesives to seal root dentin surfaces that were exposed to water and lactic acid challenges. METHODS: Four commercially-available dentin adhesives were applied with a small sponge to the root dentin of extracted human molars as de-sensitizing agents. Impression replicas of the adhesive-covered root dentin were fabricated after water immersion, as a control, and after lactic acid challenge. The replicas were examined with SEM for quantitative comparison of fluid droplet formation on the surfaces. The bonded specimens were also examined using reflected light confocal microscopy. RESULTS: Replicas of water droplets were observed on the adhesive surfaces, by SEM which corresponded with direct confocal observation of blisters and voids from the surface of the bonded specimens. There were significantly more water droplets from samples that were subjected to lactic acid challenge than water only immersion. SIGNIFICANCE: Although the dentin adhesives examined were able to cover exposed root dentin, they all exhibited fluid transudation through the polymerized adhesives. Dentin adhesives were also susceptible to surface degradation after lactic acid challenge. As simplified self-etch adhesives were highly water permeable and exhibited the most extensive surface damage, they may not be the best adhesives to be used for long-term dentin desensitization. These preliminary in vitro findings warrant validation in vivo.

Dentin Permeability↗

Effect of resin hydrophilicity and temperature on water sorption of dental adhesive resins.

This study examined the effects of copolymer hydrophilicity and temperature on water sorption and solubility characteristics of five copolymer blends of increasing degree of hydrophilicity using gravimetric measurements. Six resin disks (15 mm in diameter x 1 mm in thickness) were prepared from each copolymer blend and were stored in deionised water at 23, 37 and 55 degrees C. Water sorption and solubility of the resin disks were measured before and after water immersion and desiccation. Multiple regression analysis of water sorption was performed on two independent variables, copolymer hydrophilicity and temperature. Maximum water sorption increased significantly with Hoy's total cohesive energy density (delta(t)), Hoy's solubility parameter for polar forces (delta(p)) and hydrogen bonding (delta(h)), but was not influenced by temperature. However, a significant positive relationship was observed between diffusion coefficients (obtained using Fick's law of diffusion) and temperature. The water absorption activation energy was 10 kJ/mol for the most hydrophilic copolymer blend R5 and 35-51 kJ/mol for copolymer blends R1-R4. The positive relationship between maximum water uptake and copolymer hydrophilicity suggests that water molecules diffuse through the polymer matrices by binding successively to the polar sites via hydrogen bonding. Such water sorption may determine the durability of resin-dentine bonds.

Adhesives↗

Single-bottle adhesives behave as permeable membranes after polymerisation. II. Differential permeability reduction with an oxalate desensitiser.

OBJECTIVES: This study examined the changes in hydraulic conductance and ultrastructure of dentine bonded with simplified etch-and-rinse adhesives to oxalate desensitiser pre-treated acid-etched dentine. METHODS: Human dentine disks were acid-etched, treated with an oxalate desensitiser (BisBlock, Bisco), and bonded with One-Step (OS), Single Bond (SB), OptiBond Solo Plus (OB) or Prime and Bond NT (PB). Similar disks from each group were acid-etched, and bonded without oxalate pre-treatment. Hydraulic conductance of the specimens was measured at 20 cm of water pressure and analysed with nonparametric statistical methods. Epoxy resin replicas of the smear layer-covered dentine and bonded dentine were examined with SEM for the extent of fluid transudation. Specimens bonded under perfusion were examined with TEM after tracer immersion. RESULTS: OB and PB exhibited a highly significant reversal of the reduced hydraulic conductance obtained with BisBlock on unbonded acid-etched dentine. Profuse water transudation across the bonded dentine was observed from the replicas. Adhesive interfaces were covered with spherical globules that interfered with dentine hybridization. Conversely, no significant difference in hydraulic conductance was observed in SB, between Bisblock pre-treated, unbonded and bonded acid-etched dentine. Significantly lower hydraulic conductance was shown on application of OS to Bisblock-treated acid-etched dentine. Water transudation was sparse, interfering surface globular structures were absent, and only angular subsurface crystals were seen in the dentinal tubules. CONCLUSIONS: Convective water fluxes through dentine may be reduced by applying Bisblock to acid-etched dentine before bonding with One-Step or Single Bond. However, reducing adhesive permeability with the use of oxalate desensitiser is not applicable to low acidity adhesives such as OptiBond Solo Plus and Prime and Bond NT.

Adhesives↗

Permeability of marginal hybrid layers in composite restorations.

The goal of adhesive dentistry is to restore the peripheral seal of dentin lost from removal of enamel. Unfortunately, the hybrid layer (HL) that is used to create that seal is permeable to small ions or molecules, even in the absence of detectable, interfacial gap formation via nanoleakage. This nanoleakage results from several mechanisms including incomplete infiltration of adhesive monomers into demineralized collagen matrix, presence of hydrophilic monomers, and insufficient removal of solvent or water that remains trapped inside the HL. These mechanisms lead to a porous interface with nanometer-sized channels that increase the permeability of the HL. The null hypothesis tested in this study was that water and acidic solution storage are able to alter in vitro the resin-dentin interface, further increasing the marginal hybrid layer (MHL) permeability. Class II cavities were made in vitro. The specimens were stored in water for 1 week and in lactic acid solution for 3 days. Polyvinyl siloxane impressions of restoration margins were taken before and after storage in water and lactic acid solution. Polyether replicas were obtained using the silicon impressions as molds. Replicas and original samples were observed under scanning electron microscopy. Lines of water droplets were detected on MHLs and overlying adhesive only after storage. Replicas obtained after acidic solution storage showed great numbers of irregularities such as gaps, voids, and degradation of the dentin-restoration surface margin, but also a great number of droplets. Dentin-restoration resin interfaces absorb water and are damaged by storage in dilute lactic acid. The presence of water droplets probably indicates water that flows out of the interface during the setting time of the impression and thus represents an index of marginal HL water permeability.

Acrylic Resins↗

Nanoleakage within the hybrid layer: a correlative FEISEM/TEM investigation.

The aim of this study was to compare the nanoleakage patterns of the resin-dentin interfaces of three dentin bonding systems at both TEM and field emission in lens SEM (FEI-SEM) levels. A standardized smear layer was created with 180-grit silicon carbide paper (SiC) on dentin disks obtained from 18 noncarious human third molars. Specimens were randomly divided into three groups and bonded with a two-step total etching adhesive (Single Bond, SB), a two-step, self-etching adhesive (Clearfil SE BOND, SEB), and a one-step, self-etching adhesive (XENO III, XEIII). Nanoleakage was evaluated by using an ammoniacal silver-nitrate solution. Specimens were processed for TEM and FEI-SEM observation. The TEM of SB revealed silver deposits in adhesive and hybrid layers (HL). High-magnification FEI-SEM micrographs clearly identified these deposits as spherical clusters mainly associated with nonembedded collagen fibrils. TEM and FEI-SEM examination of SEB revealed some clusters of silver deposits within porosities and small channels of the HL. Additional silver deposits were observed between the peritubular dentin walls and the resin tags. XEIII revealed very fine and diffuse silver grains throughout the entire HL. SEM visualization of nanoleakage at a high level of resolution has not been previously described. FEI-SEM technology supported the TEM visualization with three-dimensional morphological data of the relations between the HL constituents and nanoleakage. The results of the present study confirm the hypothesis that both total- and self-etch adhesives are not able to fully infiltrate the dentin substrate.

Acid Etching, Dental↗

A challenge to the conventional wisdom that simultaneous etching and resin infiltration always occurs in self-etch adhesives.

This study provided morphological evidence that discrepancies between the depth of demineralisation and the depth of resin infiltration can occur in some mild self-etch adhesives. Sound dentine specimens derived from extracted human third molars were bonded with 5 one-step and 5 two-step self-etch adhesives. One millimeter thick slabs containing the resin-dentine interfaces were immersed in 50 wt% aqueous ammoniacal silver nitrate and processed for TEM examination. A zone of partially etched but uninfiltrated dentine was identified beneath the hybrid layers in the milder versions of both one-step and two-step self-etch adhesives. This zone was characterised by the occurrence of silver deposits along the interfibrillar spaces of mineralised collagen fibrils. The silver infiltrated interfibrillar spaces were clearly identified from the one-step self-etch adhesives Xeno III, iBond, Brush&Bond and the experimental adhesive, and were thinner and only occasionally observed in the two-step self-etch adhesives Clearfil SE Bond and Clearfil Protect Bond. The more aggressive one-step and two-step adhesives that exhibit more abrupt transitions from completely demineralised to mineralised dentin were devoid of these silver-infiltrated interfibrillar spaces beneath the hybrid layers. Incomplete resin infiltration observed in some self-etch adhesives may be caused by the reduced etching potential of the acidic monomers toward the base of hybrid layers, or the presence of acidic but non-polymerisable hydrolytic adhesive components, creating potential sites for the degradation of the bonded created by these self-etch adhesives.

Acid Etching, Dental↗

An in vitro model to investigate filling of lateral canals.

Aims of this work were to examine lateral canals in extracted teeth, to propose a new technique to produce artificial lateral canals, and to compare two obturation techniques. Cleared roots were examined to record measure and shape of lateral canals. Artificial lateral canals were prepared on human demineralized teeth before final clearing. Specimens were divided in two groups: canals of group 1 were filled with Schilder's technique, canals of group 2 were filled with vertical compaction with apical backfilling. Stereomicroscopic analysis of lateral canal filling revealed lower filling rates in apical canals compared to coronal ones and higher filling rates with "vertical compaction with apical backfilling" compared to Schilder's group. The tested procedure appears to be a reliable technique to obtain standardized lateral canals and to compare filling procedures.

Decalcification Technique↗

Does hybridization of intraradicular dentin really improve fiber post retention in endodontically treated teeth?

This study tested the hypothesis that hybridization of intraradicular dentin eliminates interfacial gaps, thereby improving the coronal seal and retention of teeth restored with fiber posts. Post spaces were bonded with two types of fiber posts, using the corresponding etch-and-rinse adhesives and dual-cured resin cements. Longitudinal sections of the interfaces were examined for dentin hybridization in the coronal- and middle-thirds of the root canals. Resin replicas of these sections were evaluated for interfacial gap formation. Although intraradicular dentin hybridization was not compromised irrespective of whether the adhesives were light-cured before cementation, the universal occurrence of interfacial gaps along the hybrid layer surface or the post-cement interface reflects the challenge in bonding to post spaces with low compliance and high C-factors. The clinical success associated with bonded fiber posts is probably due predominantly to frictional retention.

Acid Etching, Dental↗

Molecular detection of Treponema denticola and Porphyromonas gingivalis in carotid and aortic atheromatous plaques by FISH: report of two cases.

Treponema denticola and Porphyromonas gingivalis have been identified in atheromatous plaques of two patients suffering from atherosclerosis by PCR and fluorescence in situ hybridization (FISH). The use of the FISH technique suggested that these periodontopathic micro-organisms might be metabolically active within the wall of arteries, under the atherosclerotic lesion.

Aged↗

Degree of conversion and permeability of dental adhesives.

The aim of this study was to analyse the extent of polymerization of different adhesive films in relation to their permeability. One adhesive of each class was investigated: OptiBond FL; One-Step; Clearfil Protect Bond; and Xeno III. Adhesive films were prepared and cured with XL-2500 (3M ESPE) for 20, 40 or 60 s. Polymerization kinetic curves of the adhesives tested were obtained with differential scanning calorimetry (DSC) and data were correlated with microhardness. The permeability of the adhesives under the same experimental conditions was evaluated on human extracted teeth connected to a permeability device and analysed statistically. The results showed that the extent of polymerization obtained from DSC exotherms was directly correlated with microhardness. An increased level of polymerization after prolonged light-curing was confirmed for all adhesives. Simplified adhesives exhibited a lower extent of polymerization and showed incomplete polymerization, even after 60 s. An inverse correlation was found between the degree of cure and the permeability. This study supports the hypothesis that the permeability of simplified adhesives is correlated with incomplete polymerization of resin monomers and the extent of light exposure. These adhesives may be rendered less permeable by using longer curing times than those recommended by the respective manufacturer.

Adhesives↗

Treponema denticola infection is not a cause of false positive Treponema pallidum serology.

It has long been assumed that parodontal disease can be a cause of false positive results in syphilis serology, but so far there are no definitive data supporting this hypothesis. In this study we tested 250 serum samples obtained from blood donors. All of them were negative when routinely screened for antibodies against Treponema pallidum. Then, all these samples were tested by immunoenzymatic (ELISA) and Western Blot (WB) assays to investigate reactivities against T. denticola. Thirteen samples showed a strong positivity when tested by both methods. When tested by WB against T. pallidum no sample met the positivity criteria. Nevertheless, bands with molecolar weights of about 30-35 KDa (endoflagellar core antigens) were recognized. All the 13 subjects serologically T. denticola positive underwent oral clinical and radiological observation: all showed a very poor parodontal status (CPSS > 103). Eleven crevicular fluid samples out of the total of 13 patients were T. denticola positive by Real Time PCR carried out using a LightCycler system. In this study we demonstrated that the presence of T. denticola in the crevicular fluid samples obtained from patients with a severe periodontal status and/or a positive serology against T. denticola is not a cause of false positive results in syphilis serology.

Antibodies, Bacterial↗

Microhardness of acid-treated and resin infiltrated human dentine.

OBJECTIVE: The aim is to determine if superficial or deep dentine microhardness (MH) is affected by different chemical dentine pre-treatments performed for resin bonding. METHODS: Dentine discs of superficial (SD) and deep dentine (DD) were obtained by transversally sectioning the crowns of human third molars. Knoop MH was measured after different treatments: (1) polished up to 4000 grit, (2) polished and etched (37% ortophosphoric acid for 15 s), (3) resin (Single Bond -SB-) infiltrated dentine after acid etching, (4) polished, etched and treated with 5% NaOCl for 2 min, (5) resin infiltrated (SB) after etching and NaOCl treatment. For resin infiltrated surfaces care was taken in order to remove the excess adhesive layer, and obtain infiltrated dentine, by measuring thickness of the sample before resin infiltration and polishing after resin infiltration until obtaining the initial thickness of the sample. Indentations (n=20) were performed on moist surfaces with a standard Knoop MH tester (20 g, 5 s). Data were expressed in Knoop Hardness Numbers (KHN) and analysed by ANOVA and multiple comparisons (P<0.05). RESULTS: Dentine KHN decreased on both SD and DD after acid etching. NaOCl treatment after acid etching did not affect MH on SD, but KHN of DD was lowered. Resin infiltration increased KHN but did not recover the initial MH values in both SD and DD. CONCLUSIONS: Treating dentine with either H3PO4 or NaOCl caused marked reduction of its surface hardness and subsequent resin infiltration was not capable to restore it.

Acid Etching, Dental↗

Appearance of the root canal walls after preparation with NiTi rotary instruments: a comparative SEM investigation.

The aim of this study was to evaluate, in vitro, with scanning electron microscope (SEM), the appearance of root canal walls shaped by three different rotary NiTi techniques and one conventional manual technique in human extracted teeth. Four different instruments were used: K3, Hero 642, RaCe and K-file. Each sample was irrigated with 5 ml of 5% NaOCl and 5 ml of 3% H2O2 and EDTA, Rc-Prep (1 ml). Each sample was prepared for SEM observation and analyzed in the coronal, middle and apical third, comparing its aspect with a predefined scale of four different parameters: presence of smear layer, pulpal debris, inorganic debris and surface profile. The apical third showed significantly more pulpal and inorganic debris, smear layer and a high number of surface profile irregularities. No significant difference was found at the coronal, middle and apical thirds between manual and rotary techniques for inorganic debris, smear layer and surface profile. Much pulpal debris were found in the apical third for K3 and RaCe compared with Hero 642 and K-file. In conclusion, mechanical rotary techniques with NiTi instruments produced quite similar results compared with a conventional manual technique using K-files. The present study demonstrated that dentin and pulpal debris, the morphology of smear layer and surface profile were only partially influenced by the type of endodontic instruments. The apical third was the anatomical area with greater amount of debris and smear layer.

Analysis of Variance↗