The chemometric resolution and quantification of overlapped peaks form comprehensive two-dimensional liquid chromatography.

The chemometric resolution and quantification of overlapped peaks from comprehensive two-dimensional (2D) liquid chromatography (LCxLC) data are demonstrated. The LCxLC data is produced from an in-house LCxLC analyzer that couples an anion-exchange column via a multi-port valve with a reversed-phase column connected to a UV absorbance detector. Three test mixtures, each containing a target analyte, are subjected to partial LCxLC separations to simulate likely cases of signal overlap. The resulting unresolved target-analyte signals are then analyzed by the standard-addition method and two chemometric methods. The LCxLC analyses of a test mixture and its corresponding standard-addition mixture results in two data matrices, one for each mixture. The stacking of these two data matrices produces a data structure that can then be analyzed by trilinear chemometric methods. One method, the generalized rank annihilation method (GRAM), uses a non-iterative eigenvalue-based approach to mathematically resolve overlapped trilinear signals. The other method, parallel factor analysis (PARAFAC), uses an iterative approach to resolve trilinear signals by the optimization of initial estimates using alternating least squares and signal constraints. In this paper, GRAM followed by PARAFAC analysis is shown to produce better qualitative and quantitative results than using each method separately. For instance, for all three test mixtures, the GRAM-PARAFAC approach improved quantitative accuracy by at least a factor of 4 and quantitative precision by more than 2 when compared to GRAM alone. This paper also introduces a new means of correcting run-to-run retention time shifts in comprehensive 2D chromatographic data.

Benzoic Acid↗

Multivariate selectivity as a metric for evaluating comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry subjected to chemometric peak deconvolution.

Two-dimensional gas chromatography (GC x GC) coupled to time-of-flight mass spectrometry (TOFMS) [GC x GC-TOFMS)] is a highly selective technique well suited to analyzing complex mixtures. The data generated is information-rich, making it applicable to multivariate quantitative analysis and pattern recognition. One separation on a GC x GC-TOFMS provides retention times on two chromatographic columns and a complete mass spectrum for each component within the mixture. In this report, we demonstrate how GC x GC-TOFMS combined with trilinear chemometric techniques, specifically parallel factor analysis (PARAFAC) initiated by trilinear decomposition (TLD), results in a powerful analytical methodology for multivariate deconvolution. Using PARAFAC, partially resolved components in complex mixtures can be deconvoluted and identified without requiring a standard data set, signal shape assumptions or any fully selective mass signals. A set of four isomers (iso-butyl, sec-butyl, tert-butyl, and n-butyl benzenes) is used to investigate the practical limitations of PARAFAC for the deconvolution of isomers at varying degrees of chromatographic resolution and mass spectral selectivity. In this report, multivariate selectivity was tested as a metric for evaluating GC x GC-TOFMS data that is subjected to PARAFAC peak deconvolution. It was found that deconvolution results were best with multivariate selectivities over 0.18. Furthermore, the application of GC x GC-TOFMS followed by TLD/PARAFAC is demonstrated for a plant metabolite sample. A region of GC x GC-TOFMS data from a complex natural sample of a derivatized metabolic plant extract from Huilmo (Sisyrinchium striatum) was analyzed using TLD/PARAFAC, demonstrating the utility of this analytical technique on a natural sample containing overlapped analytes without selective ions or peak shape assumptions.

Evaluation Studies as Topic↗

Trilinear chemometric analysis of two-dimensional comprehensive gas chromatography-time-of-flight mass spectrometry data.

Two-dimensional comprehensive gas chromatography (GC x GC) is a powerful instrumental tool in its own right that can be used to analyze complex mixtures, generating selective data that is applicable to multivariate quantitative analysis and pattern recognition. It has been recently demonstrated that by coupling GC x GC to time-of-flight mass spectrometry (TOFMS), a highly selective technique is produced. One separation on a GC x GC/TOFMS provides retention times on two chromatographic columns and a complete mass spectrum for each component within the mixture. In this manuscript, we demonstrate how the selectivity of GC x GC/TOFMS combined with trilinear chemometric techniques such as trilinear decomposition (TLD) and parallel factor analysis (PARAFAC) results in a powerful analytical methodology. Using TLD and PARAFAC, partially resolved components in complex mixtures can be deconvoluted and identified using only one data set without requiring either signal shape assumptions or fully selective mass signals. Specifically, a region of overlapped peaks in a complex environmental sample was mathematically resolved with TLD and PARAFAC to demonstrate the utility of these techniques as applied to GC x GC/TOFMS data of a complex mixture. For this data, it was determined that PARAFAC initiated by TLD performed a better deconvolution than TLD alone. After deconvolution, mass spectral profiles were then matched to library spectra for identification. A standard addition analysis was performed on one of the deconvoluted analytes to demonstrate the utility of TLD-initiated PARAFAC for quantification without the need for accurate retention time alignment between sample and standard data sets.

Gas Chromatography-Mass Spectrometry↗

Valve-based comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometric detection: instrumentation and figures-of-merit.

A valve-based comprehensive two-dimensional gas chromatograph coupled to a time-of-flight mass spectrometer (GC x GC/TOFMS) is demonstrated. The performance characteristics of the instrument were evaluated using a complex sample containing a mixture of fuel components, natural products, and organo-phosphorous compounds. The valve-based GC x GC, designed to function with an extended temperature of operation range, is shown to have high chromatographic resolution, high separation efficiency and low detection limits. Typical peak widths at base are nominally from 100 to 300 ms on column 2 and nominally 10 s on column 1. The injected mass and injected concentration limit of detection (LOD), defined as 3 standard deviations above the mean baseline noise, for three organo-phosphorous compounds (triethylphosphorothioate (TEPT), dimethyl methyl phosphonate (DMMP) and dimethyl phosphite (DMP)) in a complex environmental sample were from 6 to 38 pg, and 3 to 17 ng/ml, respectively. The temperature program for the environmental sample ranged from 40 to 230 degrees C, a temperature range capable of analyzing semi-volatile compounds. A new compact, stand-alone, valve-pulse generator device has been implemented and is also reported. The valve-based GC x GC instrument, therefore, offers a simple, rugged and less expensive alternative to thermally modulated instruments.

Gas Chromatography-Mass Spectrometry↗

Chemometric approach for the resolution and quantification of unresolved peaks in gas chromatography--selected-ion mass spectrometry data.

A semiautomated and integrated chemometric approach is presented for the resolution and quantification of unresolved target-analyte signals in gas chromatography-selected-ion monitoring (GC-SIM) data collected using scanning mass spectrometers. The chemometric approach utilizes an unskewing algorithm and two multivariate chemometric methods known as rank alignment and the generalized rank annihilation method (GRAM). The unskewing algorithm corrects the retention-time differences within a single GC-SIM data matrix caused by using a scanning mass spectrometer. Rank alignment objectively corrects the run-to-run retention-time difference between a sample GC-SIM data matrix and a standard addition GC-SIM data matrix. GRAM analysis uses the sample and standard addition data matrices to mathematically resolve and quantify the target-analyte signal(s). The resolution and quantification of severely unresolved target-analyte signals are demonstrated using GC-SIM data obtained from conventional heart-cut two-dimensional gas chromatography with mass spectrometric detection. In addition, the GC-SIM data is used to demonstrate the result of chemometric analysis when the absence of a target-analyte signal is obscured by interference. Chemometric analysis is shown to unambiguously detect an analyte based on its resolved mass chromatograms in situations where the traditional approach of measuring peak height fails to positively detect it. The predicted analyte concentrations are within 8% of the reference concentrations.

Gas Chromatography-Mass Spectrometry↗

Comprehensive two-dimensional gas chromatography of volatile and semi-volatile components using a diaphragm valve-based instrument.

A high-temperature configuration for a diaphragm valve-based gas chromatography (GCXGC) instrument is demonstrated. GCxGC is a powerful instrumental tool often used to analyze complex mixtures. Previously, the temperature limitations of valve-based GCxGC instruments were set by the maximum operating temperature of the valve, typically 175 degrees C. Thus, valve-based GCxGC was constrained to the analysis of mainly volatile components; however, many complex mixtures contain semi-volatile components as well. A new configuration is described that extends the working temperature range of diaphragm valve-based GCxGC instruments to significantly higher temperatures, so both volatile and semi-volatile compounds can be readily separated. In the current investigation, separations at temperatures up to 250 degrees C are demonstrated. This new design features both chromatographic columns in the same oven with the valve interfacing the two columns mounted in the side of the oven wall so the valve is both partially inside as well as outside the oven. The diaphragm and the sample ports in the valve are located inside the oven while the temperature-restrictive portion of the valve (containing the O-rings) is outside the oven. Temperature measurements on the surface of the valve indicate that even after a sustained oven temperature of 240 degrees C, the portions of the valve directly involved with the sampling from the first column to the second column track the oven temperature to within 1.2% while the portions of the valve that are temperature-restrictive remain well below the maximum temperature of 175 degrees C. A 26-component mixture of alkanes, ketones, and alcohols whose boiling points range from 65 degrees C (n-hexane) to 270 degrees C (n-pentadecane) is used to test the new design. Peak shapes along the first column axis suggest that sample condensation or carry-over in the valve is not a problem. Chemometric data analysis is performed to demonstrate that the resulting data have a bilinear structure. After over 6 months of use and temperature conditions up to 265 degrees C, no deterioration of the valve or its performance has been observed.

Chromatography, Gas↗