PubMed Health⌕ Search

Biomedical subjects

Carlos Henrique de Marchi

Publications and source records attributed to Carlos Henrique de Marchi.

5 recordsLinked to original sources

Sinus node dysfunction in a patient with left atrial isomerism.

We report the case of an asymptomatic six-year-old child with left atrial isomerism and sinus venosus atrial septal defect. The physical examination revealed several periods of bradycardia. During a 24-hour electrocardiographic monitoring the patient presented a significant sinus node dysfunction with sinus pauses of up to 2.4 seconds. A permanent pacemaker was implanted, with a satisfactory outcome.

Cardiac Pacing, Artificial↗

[Echocardiographic monitoring of balloon atrial septostomy].

OBJECTIVE: To assess balloon atrial septostomy monitored with echocardiography. METHODS: From August 1997 to January 2004, 31 infants with congenital heart diseases indicated for balloon atrial septostomy underwent the procedure with exclusive echocardiographic monitoring. Success was defined as the obtainment of an atrial septal defect diameter > 4 mm and ample mobility of its margins. RESULTS: The male sex predominated (83.9%). The median age was 5 days (1-150), and the median weight was 3,300 g (1,800-7,500). Transposition of the great arteries occurred in 80.6% of the patients, tricuspid valve atresia in 12.9%, total anomalous pulmonary venous drainage in 3.2%, and pulmonary atresia with intact septum in 3.2%. The procedure was successful in all patients. The size of the atrial septal defect increased from 1.8 +/- 0.8 mm to 5.8 +/- 1.3 mm (P < 0.0001) and oxygen arterial saturation from 64.5 +/- 18.9% to 85.1 +/- 9.2% (P < 0.0001). The following complications occurred: 3 balloon ruptures, one lesion of the right femoral vein, one supraventricular tachycardia, and one atrial flutter. CONCLUSION: Balloon atrial septostomy monitored with echocardiography is a safe and effective procedure. It may be performed at bedside, avoiding transporting of the patient, identifies the catheter location, reduces the occurrence of severe complications, and assesses the immediate result of the procedure.

Catheterization↗

Contrast echocardiography in the diagnosis of intrapulmonary vascular dilations in candidates for liver transplantation.

OBJECTIVE: To determine the importance of contrast echocardiography in the diagnosis of intrapulmonary vascular dilations in patients with severe liver disease, who are candidates for liver transplantation. METHODS: The study comprised 76 patients with chronic liver disease and no evidence of intrinsic pulmonary disease, heart failure, or congenital heart disease with intracardiac communications, who underwent transthoracic echocardiography with second harmonic imaging. Thirty-two of them underwent consecutive transesophageal study. The result of contrast echocardiography was considered positive when the presence of contrast was detected in the left cardiac chambers with a delay of 4 to 6 cardiac cycles after initial opacification of the right cardiac chambers. RESULTS: The prevalence of intrapulmonary vascular dilations was 53.9% (41/76 patients). The sensitivity, specificity, positive and negative predictive values, and accuracy of transthoracic echocardiography as compared with those of transesophageal echocardiography for confirming pulmonary vascular abnormalities in patients with liver disease were, respectively, 75%, 100%, 100%, 80%, and 87.5%. The degree of arterial oxygenation showed no correlation with the occurrence of a positive echocardiographic study. Arterial hypoxemia (PaO2 < 70 mm Hg) was observed in 9 (15.9%) of the 76 patients. The echocardiographic study was positive in 37 (55.2%) of the 67 nonhypoxemic patients and in 4 (44.4%) of the 9 hypoxemic ones. CONCLUSION: Contrast echocardiography proved to be effective, easy, and safe to use in candidates for liver transplantation. Transthoracic echocardiography may be used in the diagnostic routine of intrapulmonary vascular dilations, the transesophageal study being reserved for inconclusive cases with clinical suspicion.

Adult↗

Contrast echocardiography in the diagnosis of intrapulmonary vascular dilations in patients eligible for liver transplantation.

OBJECTIVE: To determine the importance of contrast echocardiography in the diagnosis of intrapulmonary vascular dilations (PVD) in patients with severe hepatic diseases, eligible for transplantation. METHODS: Transthoracic echocardiography (TTE) with second harmonic imaging was performed in 76 patients, among them 32 patients were consecutively undergone to a transesophageal study (ETE). Echocardiographic contrast was obtained from microbubbles derived from the injection of agitated saline solution, in venous peripheral access. Abnormal presence of contrast in the left cardiac chambers was considered positive, with a delay of 4 to 6 cardiac cycles, after initial opacification of the right cardiac chambers. RESULTS: PVD diagnosis was performed in 53.9% of the patients (41/76). Sensibility, specificity, positive predictive value, negative predictive value, and accuracy of the TTE in relation to the ETE was 75%, 100%, 100%, 80% and 87.5%, respectively. Echocardiography was positive in 37 (55.2%) of 67 nonhypoxemic patients, and in 4 (44.4%) hypoxemic ones. No cardiologic hemodynamic repercussions from intrapulmonary shunt were observed. CONCLUSION: The contrast echocardiography is efficient, easy to be used, and safe in the search for and identification of intrapulmonary vascular alterations in patients eligible for hepatic transplantation.

Adult↗