PubMed Health⌕ Search

Biomedical subjects

Carlos-A Mestres

Publications and source records attributed to Carlos-A Mestres.

8 recordsLinked to original sources

Cryopreserved mitral homograft in the tricuspid position for infective endocarditis: a valve that can be repaired in the long-term (13 years).

Herein is reported the long-term repair of a cryopreserved mitral homograft in the tricuspid position. A 34-year-old HIV-infected patient underwent tricuspid valve replacement in 1991 with a cryopreserved mitral homograft because of infective endocarditis. Chronic tricuspid regurgitation secondary to repeated endocarditis led to reoperation 13 years later. Mitral valve repair was performed with a rigid ring as there was annular dilatation; the valve tissue was intact. One year later, transthoracic echocardiography showed no tricuspid regurgitation. The cryopreserved mitral homograft is a potentially repairable valve in the long-term.

Adult↗

Partial clamping of the brachiocephalic trunk for total ascending aorta replacement without circulatory arrest: early and midterm results.

BACKGROUND: The aim of this study was to evaluate in elective patients the early and midterm results of partial clamping of the brachiocephalic trunk (BCT) for total ascending aorta replacement (TAAR) without circulatory arrest. Contraindications to the procedure were BCT/aortic arch calcifications and chronic aortic dissection. METHODS: The right radial artery was cannulated to monitor the systemic pressure after the BCT was partially clamped. A specially designed clamp was applied obliquely to occlude approximately 50% of the BCT and part of the aortic arch. The distal tip of the clamp was positioned in front of the left subclavian artery. From January 2002 to October 2003, 92 patients underwent TAAR. In 62 patients (67.4%), partial clamping of the BCT was used. Twenty of these patients underwent isolated TAAR, 27 underwent aortic valve replacement and TAAR, 11 had a Bentall operation, and 2 had a Cabrol operation. The aortic valve was spared in the remaining 2 patients. The mean (+/- SD) aortic cross-clamping and cardiopulmonary bypass times were 96 +/- 31 minutes and 116 +/- 43 minutes, respectively. RESULTS: Early mortality was 1.6% (1 patient). No cerebrovascular accidents occurred, demonstrating the safety of the technique. The major complications were acute respiratory insufficiency in 2 cases and acute renal failure in 5. The mean follow-up time was 9.0 +/- 6.5 months. The mean 18- month and event-free survival rate was 96.6% +/- 0.9%. CONCLUSION: Partial clamping of the BCT for TAAR without circulatory arrest provides good early and midterm clinical results. Aortic arch clamping is not associated with cerebrovascular accidents.

Aorta↗

Isolated bicuspid pulmonary valve: an unusual finding.

Whilst the pulmonary valve is a tricuspid valve, very few reports exist of bicuspid pulmonary valves, the majority of which are associated with congenital heart disease. Isolated bicuspid valves not associated with congenital abnormalities are even more rare. Herein, the case is described of a 65-year-old man who died from a stroke, and in whom a bicuspid pulmonary valve was found during post-mortem dissection for tissue donation.

Autopsy↗

Posttraumatic intrapancreatic aortosplenic fistula causing portal hypertension.

Arterioportal fistulas are uncommon. The case of a patient with massive uncontrollable esophageal variceal bleeding is presented. Reversible portal hypertension was caused by a posttraumatic giant intrapancreatic aortosplenic fistula. Percutaneous closure was unsuccessful, and pancreatectomy was performed to control the bleeding. The case is discussed and the literature on this exceptional cause of portal hypertension is reviewed.

Abdominal Injuries↗