PubMed Health⌕ Search

Biomedical subjects

Carmel Hayes

Publications and source records attributed to Carmel Hayes.

8 recordsLinked to original sources

A test of performance of breast MRI interpretation in a multicentre screening study.

OBJECTIVES: The aim of this study was to assess the consistency and performance of radiologists interpreting breast magnetic resonance imaging (MRI) examinations. MATERIALS AND METHODS: Two test sets of eight cases comprising cancers, benign disease, technical problems and parenchymal enhancement were prepared from two manufacturers' equipment (X and Y) and reported by 15 radiologists using the recording form and scoring system of the UK MRI breast screening study [(MAgnetic Resonance Imaging in Breast Screening (MARIBS)]. Variations in assessments of morphology, kinetic scores and diagnosis were measured by assessing intraobserver and interobserver variability and agreement. The sensitivity and specificity of reporting performances was determined using receiver operating characteristic (ROC) curve analysis. RESULTS: Intraobserver variation was seen in 13 (27.7%) of 47 of the radiologists' conclusions (four technical and seven pathological differences). Substantial interobserver variation was observed in the scores recorded for morphology, pattern of enhancement, quantification of enhancement and washout pattern. The overall sensitivity of breast MRI was high [88.6%, 95% confidence interval (CI) 77.4-94.7%], combined with a specificity of 69.2% (95% CI 60.5-76.7%). The sensitivities were similar for the two test sets (P=.3), but the specificity was significantly higher for the Manufacturer X dataset (P<.001). ROC curve analysis gave an area under the curve of 0.85 (95% CI 0.79-0.92) CONCLUSIONS: Substantial variation in all elements of the scoring system and in the overall diagnostic conclusions was observed between radiologists participating in MARIBS. High overall sensitivity was achieved with moderate specificity. Manufacturer-related differences in specificities possibly occurred because the numerical thresholds set for the scoring system were not optimised for both equipment manufacturers. Scoring systems developed on one equipment software may not be transferable to other manufacturers.

Breast Neoplasms↗

Prediction of clinicopathologic response of breast cancer to primary chemotherapy at contrast-enhanced MR imaging: initial clinical results.

PURPOSE: To prospectively document changes in contrast agent kinetics in patients with primary breast cancer treated with systemic chemotherapy after one or two cycles and to determine whether kinetic measures can be used to predict final clinicopathologic response. MATERIALS AND METHODS: Institutional committees on clinical research and ethics approval and patient consent were obtained. Dynamic magnetic resonance (MR) examinations were performed in 25 women with primary breast cancer before treatment and after the first (n = 21) and second (n = 15) cycle of neoadjuvant chemotherapy. Kinetic parameters (transfer constant, leakage space, and rate constant) were derived for whole tumor regions of interest. Changes in histogram distributions of pixel data (median value and range) and MR imaging-derived size were correlated with final clinical and histologic response by using nonparametric methods. Receiver operating characteristic (ROC) analysis of tumor size and transfer constant changes were used to identify patients in whom no benefit was gained from chemotherapy. RESULTS: After the first cycle of treatment, 12 of 14 clinical responders showed decreases in tumor size, and six of seven nonresponders showed increases or no change in tumor size (P < .001). Transfer constant changes did not differ between responders and nonresponders for either clinical or pathologic assessments. After two cycles of treatment, there were tumor size increases in five of six nonresponders compared with decreases in eight of nine responders (P < .001). Reductions in transfer constant range were also observed in responders for both clinical and pathologic assessments (P = .008 and .02, respectively). No other kinetic parameter change predicted response. Size and transfer constant range were equally accurate for predicting the absence of pathologic response after two cycles of treatment (sensitivity, specificity, and area under ROC curve were 100%, 90%, and 0.93, respectively, for size and 100%, 75%, and 0.94, respectively, for transfer constant range). CONCLUSION: Reductions in MR imaging-determined size of the primary tumor best predict clinicopathologic response of breast cancer after one cycle of neoadjuvant chemotherapy. Transfer constant and size changes are equally sensitive in the identification of patients who would gain no clinical or pathologic benefit after two cycles of treatment.

Adult↗

Assessment of left ventricular function by breath-hold cine MR imaging: Comparison of different steady-state free precession sequences.

PURPOSE: To compare steady-state free precession (SSFP) sequence protocols with different acquisition times (TA) and temporal resolutions (tRes) due to the implementation of a view sharing technique called shared phases for the assessment of left ventricular (LV) function by breath-hold cine magnetic resonance (MR) imaging. MATERIALS AND METHODS: End-diastolic and end-systolic volumes (EDV, ESV) were measured in contiguous short-axis slices with a thickness of 8 mm acquired in 10 healthy male volunteers. The following true fast imaging with steady-state precession (TrueFISP) sequence protocols were compared: protocol A) internal standard of reference, segmented: tRes 34.5 msec, TA 18 beats per slice; protocol B) segmented, shared phases: tRes 34.1 msec, TA 10 beats per slice; and protocol C) real-time, shared phases, parallel acquisition technique: tRes 47.3 msec, TA 24 beats for 12 slices covering the entire left ventricle. RESULTS: Phase sharing leads to a significant decrease in EDV, stroke volume (SV), and ejection fraction (EF) (median difference -7.0 mL [*], -9.6 mL, and -3.4%, respectively, for protocol B; -15.3 mL, -13.3 mL, and -2.4% for protocol C; P = 0.002, *P = 0.021). The observed median difference of real-time EDV and SV estimates is of clinical relevance. Real-time cine MR imaging shows a greater variability of EDV and SV. No relevant differences in ESV were observed. CONCLUSION: The true cine frame duration of both shared phases sequence protocols exceeds the period of isovolumetric contraction (IVCT) of the left ventricle resulting in a systematic and significant underestimation of EDV and consequently SV and EF. SSFP sequence protocol parameters, particularly tRes and use of view sharing techniques, should therefore be known at follow-up examinations in order to be able to assess LV remodeling in patients with heart failure.

Adult↗

Phase-sensitive inversion-recovery MR imaging in the detection of myocardial infarction.

PURPOSE: To prospectively determine if phase-sensitive inversion-recovery (IR) magnetic resonance (MR) imaging eliminates the need to find the precise inversion time (TI) to null the signal of normal myocardium to achieve high contrast between infarcted and normal myocardium. MATERIALS AND METHODS: Informed consent was obtained from each patient for this prospective MR imaging research study, which was approved by the institutional review board. Twenty patients (16 men; four women; mean age, 56 years +/- 12.3) who experienced Q-wave myocardial infarction 2 weeks earlier were examined with a 1.5-T MR system 10 minutes after administration of 0.1 mmol per kilogram of body weight gadobenate dimeglumine. To determine the optimal TI, a TI scout sequence was used. A segmented two-dimensional IR turbo fast low-angle shot (FLASH) sequence and a segmented two-dimensional IR true fast imaging with steady-state precession (FISP) sequence that produces both phase-sensitive and magnitude-reconstructed images were used at TI values of 200-600 msec (TI values were varied in 100-msec steps) and at optimal TI (mean value, 330 msec). Contrast-to-noise ratios (CNRs) of normal and infarcted myocardium and the area of infarcted myocardium were determined. Magnitude-reconstructed IR turbo FLASH images were compared with magnitude-reconstructed and phase-sensitive IR true FISP images. Two-tailed unpaired sample Student t test was used to compare CNRs, and two-tailed paired-sample Student t test was used to compare area of infarction. RESULTS: Mean CNR of images acquired with IR turbo FLASH and IR true FISP (phase-sensitive and magnitude-reconstructed images) at optimal TI (mean value, 330 msec) were 6.6, 6.2, and 6.1, respectively. For a TI of 200 msec, CNR values were -4.3, -4.0, and 7.2, respectively; for TI of 600 msec, CNR values were 3.1, 3.3, and 4.3, respectively. Area of infarcted myocardium was underestimated on magnitude-reconstruction images (P = .002-.03) for short TI values (ie, 200 msec) for both sequences and for a TI of 300 msec for IR true FISP but not on phase-sensitive reconstructed IR true FISP images when compared with IR turbo FLASH images obtained at optimal TI. CONCLUSION: Phase-sensitive image reconstruction results in reduced need for precise choice of TI and more consistent image quality.

Adult↗

Evaluation of radiological features for breast tumour classification in clinical screening with machine learning methods.

OBJECTIVE: In this work, methods utilizing supervised and unsupervised machine learning are applied to analyze radiologically derived morphological and calculated kinetic tumour features. The features are extracted from dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) time-course data. MATERIAL: The DCE-MRI data of the female breast are obtained within the UK Multicenter Breast Screening Study. The group of patients imaged in this study is selected on the basis of an increased genetic risk for developing breast cancer. METHODS: The k-means clustering and self-organizing maps (SOM) are applied to analyze the signal structure in terms of visualization. We employ k-nearest neighbor classifiers (k-nn), support vector machines (SVM) and decision trees (DT) to classify features using a computer aided diagnosis (CAD) approach. RESULTS: Regarding the unsupervised techniques, clustering according to features indicating benign and malignant characteristics is observed to a limited extend. The supervised approaches classified the data with 74% accuracy (DT) and providing an area under the receiver-operator-characteristics (ROC) curve (AUC) of 0.88 (SVM). CONCLUSION: It was found that contour and wash-out type (WOT) features determined by the radiologists lead to the best SVM classification results. Although a fast signal uptake in early time-point measurements is an important feature for malignant/benign classification of tumours, our results indicate that the wash-out characteristics might be considered as important.

Artificial Intelligence↗

Reproducibility of quantitative dynamic MRI of normal human tissues.

The aim of the study was to establish the normal range and to evaluate the reproducibility of dynamic contrast enhanced MRI (DCE-MRI) parameter estimates in normal human pelvic tissues. Nineteen patients with prostate cancer, undergoing androgen deprivation treatment, had paired DCE-MRI examinations of the pelvis using spoiled gradient-echo sequences. Quantitative enhancement parameters were calculated for each examination: transfer constant (K(trans)), leakage space (v(e)) and maximum contrast medium accumulation (MCMA) of pelvic muscles, bone marrow and fat. Descriptive and reproducibility statistics were calculated: within-patient standard deviation (wSD), repeatability and within-patient coefficient of variation (wCV). The femoral head and ischiorectal fat showed large numbers of non-enhancing pixels (81 and 88%, respectively). The ischial bone marrow had the highest values of kinetic parameter estimates (K(trans) 0.554 min(-1), v(e) 18.5% and MCMA 0.164 mmol/kg). Muscle parameters values were lower (K(trans) 0.126-0.137 min(-1), v(e) 10.6-11.5% and MCMA 0.077-0.086 mmol/kg). The mean difference between paired examinations was not significantly different from zero for any parameter. v(e) and MCMA had the lowest wCV (between 19 and 29%). For individuals, a log(10) K(trans) change of approximately 0.90 in muscles and 0.52 in the ischium would be statistically significant. The corresponding absolute changes for v(e) are 6.7% in muscle and 13.6% in the ischium. For a group of 19 patients, small changes are statistically significant (muscle log(10) K(trans) 0.208 and v(e) 1.5% and ischium log(10) K(trans) 0.123 and v(e) 3.1%). Fat and the femoral head are unreliable tissues from which to obtain kinetic parameter estimates due to poor enhancement. v(e) and MCMA have smaller coefficient of variation than K(trans) in muscles and ischium. Reproducibility studies of normal and pathological tissues should be incorporated into clinical research protocols that measure treatment effects by DCE-MRI techniques.

Adipose Tissue↗

Assessing changes in tumour vascular function using dynamic contrast-enhanced magnetic resonance imaging.

Dynamic contrast-enhanced MRI (DCE-MRI) is widely used in the diagnosis and staging of cancer and is emerging as a promising method for monitoring tumour response to treatment. However, DCE-MR imaging techniques are still evolving and methods of image analysis remain variable and non-standard, and range from relative changes in the pattern of enhancement to pharmacokinetic modelling of contrast agent uptake. The combination of results from different institutions is therefore difficult and the sensitivities of different methods have not been compared. The purpose of this study is to investigate correlations between qualitative and quantitative methods of analysis for DCE-MR images from breast cancer patients undergoing neo-adjuvant chemotherapy. Fifteen patients underwent DCE-MRI examinations before and after one course of chemotherapy. Changes in the temporal pattern of signal enhancement, the rate and amplitude of enhancement and the volume transfer constant of contrast agent between the blood plasma and the extravascular extracellular space (EES), K(trans), and the EES fractional volume, nu(e), were determined. In addition, whole tumour region-of-interest analysis was compared with histogram analysis to investigate the extent of tumour heterogeneity. It was found that changes in the rate of enhancement correlated strongly with changes in K(trans) values (Kendall's tau = 0.68, P < 0.001). Furthermore, it was found that the shape of the signal enhancement curve only changed when the K(trans) values changed by 50% or more. Median K(trans) values determined following histogram analysis of pixel maps of K(trans) were approximately equal to those determined by whole tumour region-of-interest analysis. The absolute change in the K(trans) values correlated negatively with the pre-treatment values, particularly for responding patients. Thus, for higher pre-treatment K(trans) values, a greater decrease was observed. Greater changes were observed in the upper extremes of the K(trans) histogram than in the median values after one course of treatment.

Adult↗

What is the recall rate of breast MRI when used for screening asymptomatic women at high risk?

Breast screening acceptability is dependent on sensitivity and recall rate. We aimed to establish the recall rate for MRI and mammography, separately and together, when screening a cohort of women at high genetic risk. Women aged 35-49 years in the MARIBS study form the cohort. We analysed the recall rate, the number of extra tests and their effectiveness. Wilcoxon Rank test was used to estimate the effect of age and logistic regression with robust variance the effect of mammographic density on recall rates. The first 726 screening studies took place in 415 women. Following 86 of these recall occurred, comprising 140 additional investigations. 28 of the cases were resolved without further MRI, and 18 women had more than 2 additional tests. Neither age nor mammographic density was associated with recall. MRI had a recall of rate of 10.19%, and mammography 4.00%. The two techniques largely recalled different cases and 10 cases only (11.62% of those recalled) were abnormal by both tests. The two together had a recall rate of 11.85%. Recall rates varied widely between centres of the study. Breast MRI in asymptomatic high-risk women age 35-49 years largely recalls different women from mammography. The combined figure of approximately 12% may be acceptable for screening and will be useful for planning similar studies.

Adult↗