PubMed Health⌕ Search

Biomedical subjects

Carmelo J Panetta

Publications and source records attributed to Carmelo J Panetta.

8 recordsLinked to original sources

Acute coronary syndromes in patients with renal disease: what are the issues?

Patients with chronic kidney disease and acute coronary syndromes are at high risk for both bleeding and ischemic events. This risk increases with the severity of renal insufficiency. Management for acute coronary syndromes in the setting of kidney disease is a paradox; as the benefit of current treatment is high, so is the risk for complications. Patients with chronic renal disease are frequently excluded from randomized clinical trials, and therefore, the optimal treatment strategies are often speculative in this high-risk patient population. Additional research is needed to further refine the optimal management of patients with chronic kidney disease in the setting of acute coronary syndromes.

Acute Disease↗

Iso-osmolar radio contrast iodixanol in patients with chronic kidney disease.

BACKGROUND: Although radio contrast volume has been associated with worsening post-procedural kidney function, this relationship has not been extensively studied using an iso-osmolar contrast agent in chronic kidney disease patients. METHODS: We retrospectively studied patients undergoing cardiac catheterization at the University of Minnesota from 2000 to 2004, using the iso-osmolar contrast agent, iodixanol. All patients were included who had calculated creatinine clearance (CCR) < 60 mL/min, not on dialysis, and serum creatinine measured on the same day and within 7 days after the procedure. Comparison of a subgroup with severe chronic kidney disease and diabetes mellitus was compared to a similar historical control group that used the low-osmolar contrast agent, iohexol. RESULTS: Serum creatinine and CCR were 2.9 +/- 1.5 mg/dL and 33.4 +/- 12.0 mL/min (mean +/- standard deviation), respectively, at baseline in 117 cases. Peak creatinine increased by 0.03 +/- 0.7 mg/dL after 84.3 +/- 67.3 mL of iodixanol was used. Contrast-induced nephropathy definition was fulfilled in 22 (18.8%) cases. A non-significant negative correlation was found between the volume of iodixanol and the change in creatinine (r2 = 0.0011, p = 0.7254). A subgroup with severe chronic kidney disease and diabetes mellitus with iodixanol had a significantly lower creatinine increase (n = 25, 0.09 +/- 0.5 mg/dL), compared to historical controls (n = 42, 0.7 +/- 0.8 mg/dL) with iohexol (p < 0.001). A non-significant positive correlation between volume of contrast and change in creatinine was found in this subgroup who received iodixanol (n = 25, r2 = 0.0756, p = 0.1835), but was significant in the historical controls who received iohexol (n = 42, r2 = 0.135, p = 0.017). CONCLUSIONS: The volume of iso-osmolar radio contrast does not affect the incidence of contrast-induced nephropathy in patients with chronic kidney disease. A randomized trial evaluating the incidence of contrast nephropathy would verify the safety of ad hoc versus staged angiographic procedures in this population.

Adult↗

Feasibility assessment of aortic valve area in patients with aortic stenosis using a pressure wire through a 4 French system and single femoral arterial access.

OBJECTIVE: We sought to determine the safety, success and accuracy of using a pressure wire through a 4 French catheter with single arterial access to determine the aortic valve area in patients with aortic stenosis. BACKGROUND: Conventional invasive techniques to assess aortic stenosis are associated with procedural risks secondary to bilateral femoral access or the sheath size and reduced accuracy using femoral sheath pressure to replace ascending aortic pressure. METHODS: Cardiac output was measured using a pulmonary artery catheter. With a 4 French catheter through single femoral access ascending aortic pressure and, with a pressure wire, left ventricular pressure were recorded simultaneously in four patients with aortic stenosis. Likewise, both pressures were recorded using the pullback method. Pressure gradients were determined by both methods and aortic valve area calculated with the Gorlin equation prior to correlation. Of note, patients with significant arrhythmias such as atrial fibrillation or frequent premature atrial or ventricular contractions were excluded to maintain accuracy of the pullback method. RESULTS: All hemodynamic parameters were successfully obtained in all four patients. The correlation between pressure wire and pullback method was highly significant in this case series (n = 4, r = 0.983, p = 0.017). There were no complications. CONCLUSION: The results suggest that the aortic valve area can be safely and accurately evaluated with a pressure wire using a 4 French system. This novel method could be the preferred method for patients with vascular access limitations.

Aged↗

Cutting balloon angioplasty vs. conventional balloon angioplasty in patients receiving intracoronary brachytherapy for the treatment of in-stent restenosis.

The objective of this study was to evaluate the safety and efficacy of cutting balloon angioplasty (CBA) for the treatment of in-stent restenosis prior to intracoronary brachytherapy (ICB). Cutting balloon angioplasty may reduce the incidence of uncontrolled dissection requiring adjunctive stenting and may limit "melon seeding" and geographic miss in patients with in-stent restenosis who are subsequently treated with ICB. We performed a retrospective case-control analysis of 134 consecutive patients with in-stent restenosis who were treated with ICB preceded by either CBA or conventional balloon angioplasty. We identified 44 patients who underwent CBA and ICB, and 90 control patients who underwent conventional percutaneous transluminal coronary angioplasty (PTCA) and ICB for the treatment of in-stent restenosis. Adjunctive coronary stenting was performed in 13 patients (29.5%) in the CBA/ICB group and 41 patients (45.6%; P < 0.001) in the PTCA/ICB group. There was no difference in the injury length or active treatment (ICB) length. The procedural and angiographic success rates were similar in both groups. There were no statistically significant differences in the incidence of death, myocardial infarction, recurrent angina pectoris, subsequent target lumen revascularization, or the composite endpoint of all four clinical outcomes (P > 0.05). Despite sound theoretical reasons why CBA may be better than conventional balloon angioplasty for treatment of in-stent restenosis with ICB, and despite a reduction in the need for adjunctive coronary stenting, we were unable to identify differences in clinical outcome.

Aged↗

Pseudoperforation during kissing balloon angioplasty.

We describe a case of apparent perforation during kissing balloon angioplasty of a bifurcation lesion. There was no evidence of perforation on follow-up angiography or via intravascular ultrasound. Possible etiologies include minimal perforation that immediately sealed postdeflation or forced contrast into the microvascular bed via a proximal side branch.

Aged↗

Incidence, correlates, management, and clinical outcome of coronary perforation: analysis of 16,298 procedures.

BACKGROUND: Coronary perforation is a serious but uncommon complication of percutaneous coronary intervention (PCI) and is associated with significant morbidity and mortality. METHODS: We performed an analysis of the Mayo Clinic PCI database. Clinical records, procedural reports, and angiographic studies were reviewed. Multiple logistic regression analysis was performed to identify clinical, procedural, anatomic, and angiographic correlates of coronary perforation. RESULTS: A total of 16,298 PCI procedures were performed between January 1990 and December 2001. We identified 95 coronary perforations (0.58%; 95% CI, 0.47-0.71). The incidence of coronary perforation varied with time. Correlates of coronary perforation included the use of an atheroablative device and female sex. Twelve patients (12.6%) sustained an acute myocardial infarction, and cardiac tamponade developed in 11 patients (11.6%). Management strategies included reversal of heparin, pericardiocentesis, placement of a covered stent, and surgical repair. Seven patients died (7.4%). CONCLUSIONS: Coronary perforation during PCI is rare, but is associated with significant morbidity and mortality. The variable frequency of perforation may be explained by temporal variations in the use of atheroablative devices.

Aged↗

Smooth muscle progenitor cells in human blood.

BACKGROUND: Recent animal data suggest that vascular smooth muscle cells within the neointima of the vessel wall may originate from bone marrow, providing indirect evidence for circulating smooth muscle progenitor cells (SPCs). Evidence for circulating SPCs in human subjects does not exist, and the mechanism whereby such putative SPCs may home to sites of plaque formation is presently not understood but is likely to involve expression of specific surface adhesion molecules, such as integrins. In this study, we aimed to culture smooth muscle outgrowth cells (SOCs) from SPCs in human peripheral blood and characterize surface integrin expression on these cells. METHODS AND RESULTS: Human mononuclear cells isolated from buffy coat were seeded on collagen type 1 matrix and outgrowth cells selected in endothelial growth medium (EGM-2) or EGM-2 and platelet-derived growth factor BB. Selection in platelet-derived growth factor BB-enriched medium caused rapid outgrowth and expansion of SOC to >40 population doublings in a 4-month period. These SOCs were positive for smooth muscle cell-specific alpha actin (alphaSMA), myosin heavy chain, and calponin on immunofluorescence and Western blotting and were also positive for CD34, Flt1, and Flk1 receptor but negative for Tie-2 receptor expression, suggesting a potential bone marrow angioblastic origin. In contrast, endothelial outgrowth cells (EOCs) grown in EGM-2 alone and the initial MNC population were negative for these smooth muscle-specific markers. Integrin alpha5beta1 expression by FACS and Western blotting was significantly increased in SOCs compared with EOCs, and this was confirmed by 8-fold greater adhesion of SOC to fibronectin (P<0.001), an effect that could be decreased using an alpha5beta1 antibody. Finally, SOC showed a significantly greater in vitro proliferative potential compared with EOCs of similar passage (P<0.001). CONCLUSIONS: This study demonstrates for the first time outgrowth of smooth muscle cells with a specific growth, adhesion, and integrin profile from putative SPC in human blood. These data have implications for our understanding of adult vascular smooth muscle cell differentiation, proliferation, and homing.

Adult↗

A tissue-engineered stent for cell-based vascular gene transfer.

Cell-based gene transfer using a stent platform would provide a significant advantage in terms of site-specific gene expression in the vasculature. The current study presents a novel stent design that allows stable in vivo transgene expression over a 4-week period in the vasculature. A mesh-stent coated with fibronectin provided an excellent platform for adherent porcine smooth muscle cells (SMC). Autologous porcine SMC were stably transduced with a plasmid encoding green fluorescence protein (GFP), seeded at high density in the mesh-stent, and deployed in the porcine coronary artery. Stable in vivo GFP expression within the mesh-stent (5.2 x 10(5) GFP-positive cells/cm(2) mesh) was demonstrated 1 month after implantation in the porcine coronary artery by fluorescence microscopy and flow cytometry. No significant change in GFP positive cell number within the stent occurred over a 1-month period in vivo when compared to preinsertion. Angiographic and histologic analysis revealed mild neointimal proliferation and no inflammatory infiltrate in the stented segment. This study has implications for treatment of cardiovascular and other diseases where long-term cell-based delivery of transgene is a desirable therapeutic option.

Animals↗