PubMed Health⌕ Search

Biomedical subjects

Carmen García-Jares

Publications and source records attributed to Carmen García-Jares.

13 recordsLinked to original sources

Determination of polybrominated diphenyl ethers in domestic dust by microwave-assisted solvent extraction and gas chromatography-tandem mass spectrometry.

In this paper, a rapid and simple method for the analysis of polybrominated diphenyl ethers (PBDEs) in house dust samples based on microwave-assisted solvent extraction (MASE) and gas chromatography-tandem mass spectrometry (GC-MS/MS) is presented. Extraction conditions were optimized using a multifactorial experimental design approach. The use of an aqueous NaOH phase in combination with a non-polar organic phase (hexane) to extract the target analytes from dust allowed an efficient extraction and reduced chromatographic background. The final hexane extracts could be analyzed after a simple one-step cleanup procedure using Florisil. The validation of the method was performed in terms of accuracy, linearity, and repeatability. The limits of detection (LODs) ranged from 0.29 to 0.55 ng/g for all compounds. The target PBDEs were found in several real dust samples collected in urban and rural houses of Northwestern Spain.

Analytic Sample Preparation Methods↗

Natural sunlight and sun simulator photolysis studies of tetra- to hexa-brominated diphenyl ethers in water using solid-phase microextraction.

Photo-solid-phase microextraction (photo-SPME) is combined for the first time with natural and simulated sunlight to study the photochemical behaviour of environmental concerning tetra- to hexa-brominated diphenyl ethers. The sunlight photodegradation kinetics of five brominated diphenyl ethers (BDE 47, BDE 100, BDE 99, BDE 154 and BDE 153) has been studied. These BDEs are the most abundant congeners in penta-BDE commercial formulations used as flame-retardants and are considered among the most toxic ones. The five studied BDEs were photolytically labile. The detected photodegradation products include more stable lower brominated diphenyl ethers and polybrominated dibenzofurans (PBDFs). The photoformation and decay kinetics of these photoproducts were also monitorized by photo-SPME. Aqueous photodegradation studies have also been carried out. In this case, SPME is only used as the extraction technique. Obtained results in the aqueous photodegradation experiments were compared with those obtained in photo-SPME experiments.

Ethers↗

Multivariate optimization of the factors influencing the solid-phase microextraction of pyrethroid pesticides in water.

A method based on solid-phase microextraction (SPME) and gas chromatography with micro-electron capture detection (GC-microECD) has been optimized for the analysis of pyrethroids in water samples. The influence of parameters such as temperature, fibre coating, salting-out effect and sampling mode on the extraction efficiency has been studied by means of a mix-level factorial design, which allowed the study of main effects as well as two factor interactions. Finally, a method based on direct SPME at 50 degrees C, using polydimethylsiloxane fibre is proposed. The method showed good linearity (R2>0.995) and repeatability (RSD<or=16%) for all compounds, with detection limits ranging from 0.05 pg/mL for transfluthrin to 2.18 pg/mL for permethrin, and in general <or=1 pg/mL for most pyrethroids. Reliability was demonstrated through the evaluation of the recoveries in different water samples, such as tap water, groundwater, river water, runoff water, and wastewater. These studies demonstrated the validity of external standard calibration to quantify the target compounds in real samples, including a simple dilution step for the most complex matrices, which notoriously simplifies quantification by SPME.

Chromatography, Gas↗

New approach based on solid-phase microextraction to estimate polydimethylsiloxane fibre coating-water distribution coefficients for brominated flame retardants.

A depletion solid-phase microextraction (SPME) method based on multiple SPME extraction was applied to estimate fibre coating-water distribution constants (Kfs) of brominated flame retardants. Several polybrominated diphenyl ethers (PBDEs) including compounds present in the commercial mixture "Pentamix", and two polybrominated biphenyls (PBBs) were considered as target analytes. One hundred-micrometer poly(dimethylsiloxane) (PDMS) coating fibre was selected to estimate partition coefficients. SPME kinetics studies at 25 and 100 degrees C were performed. Kfs values obtained at both temperatures for brominated flame retardants were compared with the corresponding octanol-water partition coefficients (Kow) values found in literature. A linear log-log relationship between Kow with Kfs was found. To the best of our knowledge, this is the first study where brominated flame retardants Kfs values are estimated.

Bromine↗

Simple approach for the determination of brominated flame retardants in environmental solid samples based on solvent extraction and solid-phase microextraction followed by gas chromatography-tandem mass spectrometry.

A viable approach for the analysis of polybrominated biphenyls (PBBs) and polybrominated diphenyl ethers (PBDEs) in sewage sludge samples is presented in this paper. The proposed method combines ultrasound-assisted extraction (UAE) of the solid sample and headspace solid-phase microextraction (HS-SPME) of the obtained extract, followed by gas chromatography coupled to tandem mass spectrometry (GC-MS-MS) analysis. Different parameters affecting the extraction process are evaluated and optimized. The addition of a small amount of Florisil to the sample during UAE provides a significant improvement of the chromatographic background and, at the same time, a much more efficient HS-SPME. Extensive method validation is performed using real sewage sludge samples. The proposed method exhibits good performance in terms of linearity and precision, with recoveries exceeding 92% and limits of detection in the sub ng g(-1) level. Practical applicability is demonstrated through the analysis of real contaminated sewage sludge and sediment samples in which some of the target PBDEs are detected and quantified. This proposed combined methodology represents a large time-saving when compared to other classic multi-step solvent extraction methods and it constitutes a suitable approach for the analysis of the target compounds in environmental complex solid samples.

Bromine↗

Monitoring the photochemical degradation of triclosan in wastewater by UV light and sunlight using solid-phase microextraction.

Photo solid-phase microextraction (photo-SPME) is applied for the first time to study the photochemical behavior of an emerging pollutant, triclosan, in real contaminated wastewater samples using a solar simulator. In this study, water samples are extracted by SPME and then, the fiber coating is irradiated for a selected time. This on-fiber procedure, so-called photo-SPME, followed by gas chromatography-mass spectrometry makes it possible to study photodegradation kinetics and the generation of byproducts. Several photoproducts were identified in the real samples including the 2,8-dichlorodibenzo-p-dioxin, dichlorophenols and a compound tentatively identified as other DCDD congener or a dichlorohydroxydibenzofuran. Accordingly, it was possible to postulate main photodegradation mechanisms. Photo-SPME demonstrated slower kinetics in wastewater than in spiked ultrapure water probably due to the presence of dissolved organic matter. This technique was extensively compared with conventional aqueous photodegradation showing high similarity. The influence of pH on the triclosan photolysis and on the triclosan-dioxin conversion was also investigated in wastewater. Photodegradation of triclosan and formation of 2,8-DCDD occurred independently of sample pH. This study represents an advance in the use of photo-SPME to understand the photochemical fate of environmental organic pollutants and demonstrates its clear advantages with real samples.

Chromatography, Ion Exchange↗

Further research on the photo-SPME of triclosan.

In this study the photoinduced degradation of triclosan has been investigated by photo-solid-phase microextraction (photo-SPME). In photo-SPME, photodegradation is carried out on the SPME fibre containing the target compound. Triclosan was extracted from aqueous solutions by use of polydimethylsiloxane SPME fibres and these were subsequently exposed to UV irradiation (power 8 W, wavelength 254 nm) for different times (from 2 to 60 min). The photodegradation kinetics of triclosan were investigated, the photoproducts generated were tentatively identified, and the photochemical behaviour of these products was studied by use of this on-fibre approach followed by gas chromatographic-mass spectrometric analysis. Eight photoproducts were tentatively identified, including chlorinated phenols, chlorohydroxydiphenyl ethers, 2,8-dichlorodibenzo-p-dioxin, and a possible dichlorodibenzodioxin isomer or dichlorohydroxydibenzofuran. The main photodegradation mechanisms were postulated and photodegradation pathways proposed. The effect of pH on triclosan degradation and on triclosan-to-dioxin conversion was also investigated. Triclosan degradation occurred, and generation of 2,8-dichlorodibenzo-p-dioxin was confirmed, throughout the pH range studied (from 3 to 9).

Anti-Infective Agents, Local↗

Solid-phase microextraction-gas chromatography-mass spectrometry for the analysis of selective serotonin reuptake inhibitors in environmental water.

The continuous contamination of surface waters by pharmaceuticals is of most environmental concern. Selective serotonin reuptake inhibitors (SSRIs) are drugs currently prescribed for the treatment of depressions and other psychiatric disorders and then, they are among the pharmaceuticals that can occur in environmental waters. Solid-phase microextraction (SPME) coupled to gas chromatography-mass spectrometry has been applied to the extraction of five SSRIs--venlafaxine, fluvoxamine, fluoxetine, citalopram and sertraline--from water samples. Some of the analytes were not efficiently extracted as underivatized compounds and so, an in situ acetylation step was introduced in the sample preparation procedure. Different parameters affecting extraction efficiency such as extraction mode, fiber coating and temperature were studied. A mixed-level fractional factorial design was also performed to simultaneously study the influence of other five experimental factors. Finally, a method based on direct SPME at 100 degrees C using polydimethylsiloxane-divinylbenzene fibers is proposed. The performance of the method was evaluated, showing good linearity and precision. The detection limits were in the sub-ng/mL level. Practical applicability was demonstrated through the analysis of real samples. Recoveries obtained for river water and wastewater samples were satisfactory in all cases. An important aspect of the proposed method is that no matrix effects were observed. Two of the target compounds, venlafaxine and citalopram, were detected and quantified in a sewage water sample.

Gas Chromatography-Mass Spectrometry↗

Behavior of pharmaceuticals, cosmetics and hormones in a sewage treatment plant.

Two cosmetic ingredients (galaxolide, tonalide), eight pharmaceuticals (carbamazepine, diazepam, diclofenac, ibuprofen, naproxen, roxithromycin, sulfamethoxazole and iopromide) and three hormones (estrone, 17beta-estradiol and 17alpha-ethinylestradiol) have been surveyed along the different units of a municipal Sewage Treatment Plant (STP) in Galicia, NW Spain. Among all the substances considered, significant concentrations in the influent were only found for the two musks (galaxolide and tonalide), two anti-inflammatories (ibuprofen and naproxen), two natural estrogens (estrone, 17beta-estradiol), one antibiotic (sulfamethoxazole) and the X-ray contrast medium (iopromide), where the other compounds studied were below the limit of quantification. In the primary treatment, only the fragrances (30-50%) and 17beta-estradiol (20%) were partially removed. On the other hand, the aerobic treatment (activated sludges) caused an important reduction in all compounds detected, between 35% and 75%, with the exception of iopromide, which remained in the aqueous phase. The overall removal efficiencies within the STP ranged between 70-90% for the fragrances, 40-65% for the anti-inflammatories, around 65% for 17beta-estradiol and 60% for sulfamethoxazole. However, the concentration of estrone increased along the treatment due to the partial oxidation of 17beta-estradiol in the aeration tank.

Adsorption↗

Determination of musk compounds in sewage treatment plant sludge samples by solid-phase microextraction.

Headspace solid-phase microextraction, followed by GC-MS analysis is presented as a suitable technique for the determination of musk compounds in sewage treatment plant sludge. Five polycyclic musks (celestolide, phantolide, traseolide, galaxolide and tonalide) and four nitro musks (musk xylene, musk moskene, musk tibetene and musk ketone) were considered in the optimisation of the analytical method. The influence of extraction temperature, fibre coating, agitation, pH and salting out on the efficiency of the extraction along with the extraction kinetics were studied. An extraction temperature of 100 degrees C and sampling the headspace over the stirred sludge sample using polydimethylsiloxane -divinylbenzene as fibre coating lead to effective extraction. The method proposed is very simple and yields high sensitivity, good linearity and repeatability for all the analytes with limits of detection at the sub-ng/g level. The total analysis time, including extraction and GC analysis, was only 40 min, and no manipulation of the sample was required.

Fatty Acids, Monounsaturated↗

Optimization of a derivatization-solid-phase microextraction method for the analysis of thirty phenolic pollutants in water samples.

Solid-phase microextraction (SPME) coupled to gas chromatography-mass spectrometry has been applied to the extraction of 30 phenol derivatives from water samples. Analytes were in situ acetylated and headspace solid-phase microextraction was performed. Different parameters affecting extraction efficiency were studied. Optimization of temperature, type of microextraction fiber and volume of sample has been done by means of a mixed-level categorical experimental design, which allows to study main effects and second order interactions. Five different fiber coatings were employed in this study; also, extraction temperature was studied at three levels. Both factors, fiber coating and extraction temperature, were important to achieve high sensitivity. Moreover, these parameters showed a significant interaction, which indicates the different kinetic behavior of the SPME process when different coatings are used. It was found that 75 microm carboxen-polydimethylsiloxane and 100 microm polydimethylsiloxane, yield the highest responses. The first one is specially appropriated for phenol, methylphenols and low chlorinated chlorophenols and the second one for highly chlorinated phenols. The two methods proposed in this study shown good linearity and precision. Practical applicability was demonstrated through the analysis of a real sewage water sample, contaminated with phenols.

Gas Chromatography-Mass Spectrometry↗

Optimisation of a solid-phase microextraction method for synthetic musk compounds in water.

A solid-phase microextraction method (SPME) for determining trace levels of synthetic musk fragrances in residual waters has been developed. Six polycyclic musks (cashmeran, phantolide, celestolide, traseolide, galaxolide and tonalide), and a macrocyclic musk (ambrettolide) have been analysed. A detailed study of the different parameters affecting the extraction process is presented. The main important factors affecting the microextraction process have been studied and optimised by means of a categorical factorial design. Two extraction modes (direct SPME and headspace SPME) were tried at different extraction temperatures using four different fiber coatings [polydimethylsiloxane (PDMS), Carboxen (CAR)-PDMS, PDMS-divinylbenzene (DVB) and Carbowax (CW)-DVB]. An extraction temperature of 100 degrees C sampling the headspace over the sample using CAR-PDMS or PDMS-DVB as fiber coatings were found to be the experimental conditions that lead to a more effective extraction. The method proposed is very simple and yields high sensitivity, with detection limits in the low pg/ml, good linearity and repeatability for all the target compounds. The total analysis time, including extraction and GC analysis, was only 45 min. The optimised method performed well when it was applied to waste water from an urban treatment plant.

Fatty Acids, Monounsaturated↗

Rapid determination of 2,3,7,8-tetrachlorodibenzo-p-dioxin in water samples by using solid-phase microextraction followed by gas chromatography with tandem mass spectrometry.

A rapid and simple method of using solid-phase microextraction was developed for determination of 2,3,7,8-tetrachlorodibenzo-p-dioxin (2,3,7,8-TCDD) in water samples. In this method, the target analyte is extracted from the sample into the polymeric coating of the fused-silica fiber. After exposure, the fiber is thermally desorbed in the heated injection port of the gas chromatograph, and a chromatographic analysis is performed by using low-resolution tandem mass spectrometry. Parameters that may affect the extension of the microextraction process, such as sampling mode, sample volume, temperature, agitation, and sampling time, were studied. Extraction efficiencies for 3 coating fibers were investigated: 100 microm poly(dimethylsiloxane) (PDMS), 65 microm PDMS-divinylbenzene, and 75 microm carboxen-PDMS. Linearity was evaluated (R = 0.999) for a 250-fold concentration range from the fg/mL to the pg/mL level. The 2,3,7,8-TCDD was detected at the fg/mL level when the headspace over the water sample was sampled for 60 min; the limit of detection obtained was better than that of Method 8280B of the U.S. Environmental Protection Agency. The proposed method performed well when applied to the analysis of tap water, lake water, and seawater samples.

Adsorption↗