PubMed Health⌕ Search

Biomedical subjects

Carmen Garcia-Jares

Publications and source records attributed to Carmen Garcia-Jares.

13 recordsLinked to original sources

Headspace solid-phase microextraction gas chromatography tandem mass spectrometry for the determination of brominated flame retardants in environmental solid samples.

A headspace solid-phase microextraction gas chromatography coupled with tandem mass spectrometry (HSSPME-GC-MS-MS) methodology for determination of brominated flame retardants in sediment and soil samples is presented. To the best of our knowledge, this is the first time that SPME has been applied to analyze polybrominated biphenyls (PBBs) and polybrominated diphenyl ethers (PBDEs) in environmental solid samples. Analyses were performed using 0.5-g solid samples moisturized with 2 mL water, employing a polydimethylsiloxane (PDMS) fiber coating, exposed to the headspace at 100 degrees C for 60 min. Several types of environmental solid samples were included in this study and the extraction efficiency was related to the organic matter content of the sample. Calibration was performed using real samples, and the method showed good linearity over a wide concentration range, precision, and afforded quantitative recoveries. The obtained detection limits were in the sub-ng g(-1) for all the target analytes in both samples. The proposed procedure was applied to several marine and river sediments and soils, some of which were found to contain PBDEs at concentrations in the ng g(-1) level; BDE-47, BDE-100, and BDE-99 were the major congeners detected. The proposed method constitutes a rapid and low-cost alternative for the analysis of the target brominated flame retardants in environmental solid samples, since the clean-up steps, fractionation, and preconcentration of extracts inherent to the classical multi-step solvent extraction procedures are avoided.

Journal Article↗

Development of a solid-phase microextraction method for the analysis of phenolic flame retardants in water samples.

A solid-phase microextraction (SPME) method for the ultra-trace determination of brominated phenols in aqueous samples has been developed and is reported for the first time to the best of our knowledge. 3,5,3',5'-tetrabromobisphenol A (TBBPA), the most widely used brominated flame retardant, and other phenolic flame retardants in commercial use, such as 2,4-dibromophenol (2,4-DBP), 2,4,6-tribromophenol (TBP) and pentabromophenol (PBP) have been included as target analytes. The analytical procedure involves the in situ acetylation-SPME and gas chromatography-mass spectrometry (GC-MS) determination of the target analytes. A multi-factor categorical experimental design was created to study the main parameters affecting the extraction efficiency, allowing also the evaluation of interaction effects between factors. The factors studied were type of fiber, extraction mode, exposing the fiber directly into the sample (DSPME) or into the headspace over the sample (HSSPME), and extraction temperature. Carboxen-polydimethylsiloxane (CAR-PDMS) fiber appeared to be the most suitable of the five fibers tested for the extraction of most compounds, excluding PBP and TBBPA for which polydimethylsiloxane (PDMS) was the most efficient coating. The highest response was achieved for both fibers sampling in headspace mode at 100 degrees C. In order to test the linearity of the method, calibration studies were performed with both CAR-PDMS and PDMS coatings. For both fibers, the method was linear in a range of 2 orders of magnitude, giving relative standard deviation (RSD%) below 10% for most compounds and detection limits at the low pg/mL level. In addition, the feasibility of the method for simultaneous determination of chlorinated and brominated phenols was studied. Finally, the method was applied to several real samples including tap water and effluent and influent waste water samples from an urban treatment plant, in which several phenolic compounds, such as phenol, methylphenols and chlorophenols, could be detected and quantified.

Acetylation↗

Rapid and sensitive determination of pyrethroids indoors using active sampling followed by ultrasound-assisted solvent extraction and gas chromatography.

A fast and simple method to analyze pyrethroids as well as other components of frequently used domestic insecticide preparations in indoor air is presented. The proposed method, based on sampling with an adsorbent followed by ultrasound-assisted solvent extraction, was developed with the aim to simplify the traditional extraction methodologies applied up to date to determine pesticides in air. The analytes were retained on a very small amount of adsorbent, which allowed using solely 1 mL of solvent for desorption. The quantification was performed by gas chromatography with microelectron-capture detection (GC-muECD) and gas chromatography coupled to mass spectrometry (GC-MS). The influence of main factors involved in the ultrasound-assisted solvent extraction step (type of adsorbent and type of solvent, solvent volume and extraction time) was studied using an experimental design approach to account for possible factor interactions. The sampling step was studied for two adsorbents (Tenax TA and Florisil), finding that 1 m(3) air could be sampled without losses of analytes. In this way, the analysis of pyrethroids in air by the proposed method could be carried out within a total time shorter than an hour, including sampling. Linearity was demonstrated in a wide concentration range. Efficiency of the total sampling-extraction process was studied at several concentration levels (2, 10, 100 and 1000 ng/m(3)), obtaining quantitative recoveries for all compounds, with good precision (RSD < 10%). Method detection limits were below 1 ng/m(3) in air when GC-muECD was employed, and about one order of magnitude higher for GC-MS. In addition, the proposed method was applied to real samples collected in contaminated closed rooms, in which some of the target compounds were determined.

Air Pollution, Indoor↗

Active sampling followed by solid-phase microextraction for the determination of pyrethroids in indoor air.

A method based on solid-phase enrichment followed by headspace (HS)-solid-phase microextraction (SPME) is optimized to determine pyrethroids in air. By active sampling, pyrethroids present in air are retained in 25 mg of activated florisil and then transferred from the solid sorbent to an SPME fiber in the HS mode. A small volume of solvent is added to the adsorbent to favor this process. The selection of the adsorbent, as well as the optimization of certain parameters affecting the SPME, is performed using an experimental design strategy. Linearity is studied by external calibration in a wide range of concentrations using gas chromatography coupled to three different detection systems: electron capture detection, micro-electron capture detection, and mass spectrometry. An analysis of variance with a lack-of-fit test is run to validate the calibration data. Breakthrough of the adsorbent was studied sampling from 0.5 to 10 m(3) air, demonstrating that 1 m(3) air could be sampled without losses of pyrethroids. Quantitative recoveries are obtained at three concentration levels, with adequate repeatability. Limits of detection of the method are estimated at the sub-ng/m(3) level in most cases, well below the regulatory limits. Finally, several real indoor samples are collected and analyzed by the proposed method. Identification and quantitation of all target analytes present in the room air are possible.

Air Pollutants↗

Rapid screening of selective serotonin re-uptake inhibitors in urine samples using solid-phase microextraction gas chromatography-mass spectrometry.

In this paper a solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) method is proposed for a rapid analysis of some frequently prescribed selective serotonin re-uptake inhibitors (SSRI)-venlafaxine, fluvoxamine, mirtazapine, fluoxetine, citalopram, and sertraline-in urine samples. The SPME-based method enables simultaneous determination of the target SSRI after simple in-situ derivatization of some of the target compounds. Calibration curves in water and in urine were validated and statistically compared. This revealed the absence of matrix effect and, in consequence, the possibility of quantifying SSRI in urine samples by external water calibration. Intra-day and inter-day precision was satisfactory for all the target compounds (relative standard deviation, RSD, <14%) and the detection limits achieved were <0.4 ng mL(-1) urine. The time required for the SPME step and for GC analysis (30 min each) enables high throughput. The method was applied to real urine samples from different patients being treated with some of these pharmaceuticals. Some SSRI metabolites were also detected and tentatively identified.

Antidepressive Agents, Second-Generation↗

Multivariate optimization of a solid-phase microextraction method for the analysis of phthalate esters in environmental waters.

A solid-phase microextraction method (SPME) coupled to gas chromatography-mass spectrometry (GC-MS) has been developed for the determination of the six phthalate esters included in the US Environmental Protection Agency (EPA) Priority Pollutants list in water samples. These compounds are dimethyl phthalate (DMP), diethyl phthalate (DEP), di-n-butyl phthalate (DBP), butylbenzyl phthalate (BBP), di-2-ethylhexyl phthalate (DEHP) and di-n-octyl phthalate (DOP). Detailed discussion of the different parameters, which could affect the extraction process, is presented. Main factors have been studied and optimized by means of a multifactor categorical design. Different commercial fibers, polydimethylsiloxane (PDMS), polydimethylsiloxane-divinylbenzene (PDMS-DVB), polyacrylate (PA), Carboxen-polydimethylsiloxane (CAR-PDMS) and Carbowax-divinylbenzene (CW-DVB), have been investigated, as well as the extraction mode, exposing the fiber directly into the sample (DSPME) or into the headspace over the sample (HS-SPME), and different extraction temperatures. The use of this experimental design allowed for the evaluation of interactions between factors. Extraction kinetics has also been studied. The optimized microextraction method showed linear response and good precision for all target analytes. Detection limits were estimated considering the contamination problems associated to phthalate analysis. They were in the low pg mL(-1), excluding DEHP (100 pg mL(-1)). The applicability of the developed SPME method was demonstrated for several real water samples including mineral, river, industrial port and sewage water samples. All the target analytes were found in real samples. Levels of DEP and DEHP were over 1 ng mL(-1) in some of the samples.

Chemical Fractionation↗

Sampling and analysis of polychlorinated biphenyls in indoor air by sorbent enrichment followed by headspace solid-phase microextraction and gas chromatography-tandem mass spectrometry.

In this study, a combination of solid-phase extraction (SPE) and solid-phase microextraction (SPME) techniques has been used to determine polychlorinated biphenyls (PCBs) in air. Using a vacuum pump, a known volume of air was pulled through a porous polymer (Tenax TA) where the target analytes were retained and then headspace SPME was carried out. The quantification was performed using gas chromatography coupled to tandem mass spectrometry. Certain factors, such as temperature and the addition of solvents to the adsorbent, were found to be very important for the transfer of the target PCBs from the Tenax to the SPME fiber. Some of these factors were studied using an experimental design strategy. Performance of the method was evaluated demonstrating that external calibration, which does not require performing the complete sampling process, was suitable. The coefficients of determination were calculated and a lack-of-fit test was run within the calibration data, demonstrating linearity of the method. Repeatability was found adequate (RSD < or = 12%). Limits of detection (LODs) were found below 0.100 ng/m3 when only 2.5 m3 air were sampled. These LODs were low enough to check for harmful levels of PCBs in indoor air, and are well below the most restrictive limits established by countries regulations. In addition, more sensitivity could be attained by increasing the volume of air sampled (decrease in retention efficiency was not detected for sample volumes up to 25 m3), and/or extending the extraction time in the SPME step.

Air Pollution, Indoor↗

Investigation of photodegradation products generated after UV-irradiation of five polybrominated diphenyl ethers using photo solid-phase microextraction.

In this study, the photoinduced degradation of five polybrominated diphenyl ethers (PBDEs), BDE-47, BDE-100, BDE-99, BDE-154 and BDE-153, is studied using solid-phase microextraction polydimethylsiloxane fibers as photolytic support. PBDEs are extracted from aqueous solutions using SPME fibers that are subsequently exposed to UV irradiation for different times (from 2 to 60 min). Photodegradation kinetics of the five PBDEs, tentative identification and photochemical behavior of the generated photoproducts, as well as photodegradation pathways, have been studied employing this on-fiber approach technique (photo-SPME) followed by gas chromatography-mass spectrometry analysis. Aqueous photodegradation studies have also been performed and compared with photo-SPME. All the photoproducts detected in the aqueous experiments were previously found in the photo-SPME experiments. In this study, reductive debromination by successive losses of bromine atoms is confirmed as the main photodegradation pathway of PBDEs. A large number of PBDEs were obtained as photoproducts of the five target analytes. Other mechanism of photodegradation observed was intramolecular cyclization from the homolytic dissociation of the C-Br bond; thus, polybromo-dibenzofurans were generated. This work contributes to the study of the photodegradation of PBDEs and shows the potential of photo-SPME to evaluate the photo-transformation of organic pollutants.

Ethers↗

Confirmation of the formation of dichlorodibenzo-p-dioxin in the photodegradation of triclosan by photo-SPME.

Photodegradation is a possible way to eliminate organic pollutants from the environment but, at the same time, can be a source of toxic byproducts. The photochemical conversion of triclosan, a common pollutant in continental waters, into dichlorodibenzo-p-dioxin (DCDD) has been confirmed in our preliminary experiments employing photo-SPME (photo-solid-phase microextraction) using 18-W UV irradiation at 254-nm wavelength. Under these conditions, triclosan is rapidly photodegraded (70% of triclosan was degraded in 2 min); the most important novel aspect of this work is the conversion of triclosan to DCDD directly on the polydimethylsiloxane coating of the SPME fiber. Moreover, this conversion is also confirmed in non-buffered aqueous photodegradation experiments using SPME as the extraction technique. In all the experiments of this study, analysis was carried out by gas chromatography-electronic impact mass spectrometry (GC-EI/MS).

Dioxins↗

A simple and fast micromethod for the analysis of polychlorinated biphenyls in air by sorbent enrichment and ultrasound-assisted solvent extraction.

A combination of sorbent enrichment and ultrasound-assisted solvent extraction has been used to determine polychlorinated biphenyls in air. Analytes were sampled by pumping a known volume of air through a porous polymer (Tenax TA). The enriched adsorbent was transferred into a glass vial, and ultrasound-assisted extraction of the analytes was then performed in n-hexane. Quantification was carried out by using gas chromatography coupled to tandem mass spectrometry. Breakthrough volume of the sampling step was studied, indicating that 10 m3 of air could be processed without losses of the most volatile compounds. Good recoveries (75-96%) were obtained, and limits of detection at the sub ng m(-3) were achieved for all the analytes. The proposed method is very simple and fast, avoiding the use of large solvent volumes and time-consuming preconcentration steps.

Journal Article↗

Application of solid-phase microextraction to the study of the photochemical behaviour of five priority pesticides: "on-fiber" and aqueous photodegradation.

Solid-phase microextraction (SPME) is applied to study the photochemical degradation of five priority pesticides: atrazine, alachlor, aldrin, dieldrin, endrin. Analyses were carried out by gas chromatography-mass spectrometry. The possibility of studying the photochemical degradation of the target compounds in solid-phase microextraction fibers, "photo-SPME", is evaluated employing different SPME coatings. The target analytes were extracted from aqueous solutions using different commercial coatings and then, the fibers were exposed to UV light. Results indicated that on-fiber photodegradation takes place in a considerably major extent using PDMS coating for an irradiation time of 30min. On-fiber photodegradation kinetics of each analyte were determined by UV irradiation of the PDMS for different times. A large number of photoproducts were generated and they were tentatively identified by means of their mass spectra and with the aid of literature. In this way, main photodegradation mechanisms could be postulated. Aqueous photodegradation studies followed by SPME were performed and compared with photo-SPME. All the photoproducts detected in the aqueous experiments were previously found in the photo-SPME experiments. This study shows the potential of photo-SPME to evaluate the photo-transformation of organic pollutants.

Gas Chromatography-Mass Spectrometry↗

Development of a sensitive methodology for the analysis of chlorobenzenes in air by combination of solid-phase extraction and headspace solid-phase microextraction.

In this study, a combination of solid-phase extraction (SPE) and solid-phase microextraction (SPME) has been used to determine chlorobenzenes in air. Analytes were sampled by pumping a known volume of air through a porous polymer (Tenax TA). Then, the adsorbent was transferred into a glass vial and SPME was performed. The quantification was carried out using gas chromatography (GC)-electron-capture detection or GC-MS. Several SPME coatings (100 microm poly(dimethylsiloxane) (PDMS), 75 microm Carboxen (CAR)-PDMS, 65 microm PDMS-divinylbenzene (DVB), 65 microm PDMS-DVB and 85 microm polyacrylate (PA) were evaluated, obtaining the highest responses with Carbowax (CW)- PDMS for the most volatile chlorobenzenes, and with PDMS-DVB or CW-DVB fibers for the semivolatile compounds. To optimize some other factors that could affect the SPME step, a factorial design was used. Kinetic studies of the SPME process were also performed. Concerning the SPE step, breakthrough was studied, showing that 2.5 m3 of air could be processed without losses of the most volatile compounds. The performance of the method was evaluated. External calibration, which does not require the complete sampling process, demonstrated to be suitable, obtaining good linearity (R2 > 0.99) for all chlorobenzenes. Recovery studies were performed at two concentration levels (4 and 40 ng/m3), obtaining quantitative recoveries (>80%). Limits of detection at the sub ng/m3 were achieved for all the target compounds.

Air↗

Study of the photoinduced degradation of polycyclic musk compounds by solid-phase microextraction and gas chromatography/mass spectrometry.

Polycyclic musks are widely used synthetic fragrances that have been identified during the last few years in biota samples and environmental matrices. Nevertheless, there is a lack of information concerning the photodegradation behavior of these compounds. In this work, the photoinduced degradation of six polycyclic musk compounds (Cashmeran, Celestolide, Phantolide, Galaxolide, Traseolide and Tonalide) was studied using a solid-phase microextraction (SPME) fiber as support. Musk fragrances were extracted from aqueous solutions using SPME fibers that were subsequently exposed to ultraviolet (UV) irradiation for different times. To study the degradation kinetics and to tentatively identify the photoproducts generated, gas chromatography coupled to ion trap mass spectrometry was used. Aqueous photodegradation studies were also performed. The on-fiber photodegradation approach avoids the need for further extraction processes and makes the identification of photoproducts easier, due to their higher concentration on the fibers. All musk compounds were easily photodegraded, suggesting that UV irradiation could work as a decontamination tool for these musks.

Journal Article↗