PubMed Health⌕ Search

Biomedical subjects

Carol H Collins

Publications and source records attributed to Carol H Collins.

At least 19 recordsLinked to original sources

Preparation and characterization of poly(methyltetradecylsiloxane) stationary phases immobilized by gamma radiation onto zirconized silica.

The preparation of stationary phases with enhanced chemical stability in alkaline eluents has been the principal objective of many chromatographers. New and improved silica substrates and advanced chemical modification methods are among the possibilities being investigated to reach this objective. The present work has evaluated these two possibilities for new stationary phases. First, the silica surface was modified by reaction with zirconium tetrabutoxide to produce zirconized silica particles having about 21% (w/w) of zirconium. Then poly(methyltetradecylsiloxane) (PMTDS) was immobilized onto this surface using different doses (50-120 kGy) of gamma radiation. These new phases were characterized using elemental analysis and infrared and solid-state (29)Si-nuclear magnetic resonance (NMR) spectroscopies. These new stationary phases presented column efficiencies of about 68,000 plates m(-1), symmetric peaks for apolar compounds and retention factors that depend on the irradiation dose and show improved stability in high pH mobile phases. The separation of several pharmaceuticals at pH 11 is presented.

Acetaminophen↗

New stationary phases for high-performance liquid chromatography based on poly(methyltetradecylsiloxane) thermally immobilized onto zirconized silica.

The modification of silica with zirconium oxide followed by sorption and thermal immobilization of poly(methyltetradecylsiloxane) (PMTDS) is used to prepare a reversed stationary phase for high-performance liquid chromatography. The thermal immobilization of PMTDS on zirconized silica was optimized using a central composite design. The new stationary phase was characterized by spectroscopic and chromatographic methods. Stationary phases with good reproducibility and good chromatographic performance for various compounds were obtained. PMTDS thermally immobilized on zirconized silica presented quite significant chemical stability at pH 10 and 50 degrees C.

Chromatography, High Pressure Liquid↗

Poly(methyloctylsiloxane) immobilized on silica as a sorbent for solid-phase extraction of some pesticides.

A laboratory-made sorbent for solid-phase extraction (SPE) was obtained by thermal immobilization of poly(methyloctylsiloxane) (PMOS) onto silica. Cartridges packed with the new sorbent were used for the simultaneous determination of imazethapyr, nicosulfuron, diuron, linuron and chlorimuron-ethyl in water. These pesticides were separated and quantified using high-performance liquid chromatography with diode array detection (HPLC-DAD). The recoveries achieved with the laboratory-made PMOS cartridges were compared with those of some commercially available silica-based and polymer-based cartridges having C18, C8 and NH(2) pendant groups. Method validation using the laboratory-made sorbent was performed for the five pesticides at three fortifications levels (1x, 2x and 10x the limit of quantification of each pesticide). The laboratory-made PMOS cartridge has low cost preparation and showed good recoveries (72-111%) for all pesticides. Repeatability and intermediate precision were lower than 15%. Its performance was similar or even better, in some cases, than those of the commercial cartridges.

Chemical Fractionation↗

Influence of the TiO2 content on the chromatographic performance and high pH stability of C18 titanized phases.

To extend pH stability, protective metal oxide layers, such as titanium oxide, that are more stable in alkaline medium, can be chemically bonded to the chromatographic silica surface prior to reaction with silanes. In the present work, the influence of the titanium oxide content on the chromatographic performance was investigated by synthesizing a C18 phase onto a doubly-titanized silica support and comparing its chromatographic performance with a C18 phase on singly-titanized silica. The Engelhardt and Tanaka test mixtures were used for chromatographic characterizations using short HPLC columns. The column lifetimes of these titanized phases were also compared by performing accelerated aging tests at 50 degrees C using aggressive phosphate mobile phases at pH 10.

Chromatography, High Pressure Liquid↗

High-performance liquid chromatographic stationary phases based on polysiloxanes with different chain lengths thermally immobilized on silica supports.

Reversed phases for high-performance liquid chromatography (RP-HPLC) were obtained by thermal immobilization of polysiloxanes having different length chains (C1, C8 and C14) onto HPLC silica particles. The importance both of percent loading of the stationary phase promoted by each immobilization procedure and of the length of the lateral chain of the polymer on the chromatographic performances of the phases obtained is compared and discussed.

Acenaphthenes↗

Immobilized polymeric stationary phases using metalized silica supports.

Immobilized presynthesized polymers on porous metalized (zirconized or titanized) silica particles as new stationary phases with improved chemical stability for RP-HPLC are reviewed. The preparations using different polymers, such as poly(methyloctylsiloxane), poly(methyltetradecylsiloxane), and poly(butadiene), different immobilization steps (gamma radiation, thermal treatment, and microwave radiation), and the chromatographic performances of these phases for polar, apolar, acidic, and basic compounds are discussed. The stability of some of these stationary phases using alkaline mobile phases is also presented.

Journal Article↗

An overview of the chromatographic properties and stability of C18 titanized phases.

Phases based on titanized silicas are an alternative in the search for HPLC stationary phases with enhanced pH stability. This technology explores the chemical modification of the bare silica surface by grafting a titanium oxide layer with the objective of retarding the dissolution of the support in alkaline mobile phases, followed by C18 silanization. The present manuscript describes recent work on the development of chemically bonded titanized phases, including phases containing embedded urea groups, and phases prepared both in the absence and in the presence of a monolayer of water preadsorbed onto the bare silica. The advantages and disadvantages of these alternative C18 titanized phases are discussed, taking into account their chromatographic properties accessed by some common test procedures. Column lifetimes, measured by accelerated aging tests using aggressive conditions, such as high-pH phosphate mobile phases and elevated temperature, are also discussed.

Journal Article↗

Preparation and characterization of a new C18 urea phase based on titanized silica.

A new stationary phase containing embedded urea groups (-NH-C(O)-NH-) was prepared by a procedure based on the synthesis of a trifunctional C18 urea-alkoxysilane, followed by modification of titanized silica and further endcapping to evaluate if the embedded group would minimize the higher retention and tailing for basic compounds seen with C18 titanized silica phases. Infrared, 13C and 29Si spectroscopies were employed to characterize the C18-urea titanized silica phase. Chromatographic evaluations used hydrophobic, polar and basic compounds to verify the effects of the polar urea groups embedded in the C18 urea phase. The chromatographic parameters, especially for the separation of basic compounds, compare favorably with those obtained on a C18 titanized silica stationary phase, prepared by silanization of titanized silica with octadecyltrimethoxysilane.

Calorimetry, Differential Scanning↗

Physisorbed water layer formation on fully hydroxylated mesoporous silicas.

Kinetic adsorption isotherms were obtained by gravimetric determination of water adsorption into fully hydroxylated mesoporous silicas using samples exposed to controlled humidity air at 22+/-2 degrees C. Twenty kinetic isotherms at several relative humidities (11, 33, 43, 51, 75, and 85%) were obtained with 11 different batches of silica using this simple procedure to obtain quantitative information on the formation of H2O adsorbates. The H2O surface concentrations obtained from the plateau data of individual kinetic adsorption isotherms at 43 and 51% RH, typically precise to about +/-1%, show that a complete monolayer is formed with negligible second-layer adsorption at these relative humidities. This monolayer has a surface concentration of 7.68+/-0.30 micromol H2O/m2, which is lower than the quasi-equilibrium concentration at these relative humidities obtained by the conventional equilibrium-isotherm procedure. Comparison with the Kiselev-Zhuravlev concentration of silanol groups on fully hydroxylated silicas (7.6+/-0.8 micromol SiOH/m2) confirms 1:1 H2O:SiOH stoichiometry of this monolayer. The presence of partial-layer structures at 2.85+/-0.1 and 5.7+/-0.1 micromol H2O/m2 is suggested by isotherms at 11 and 33% RH, respectively, while a bilayer at approximately 14+/-1 micromol H2O/m2 is suggested by kinetic isotherms at 75 and 85% RH.

Journal Article↗

High-performance liquid chromatographic stationary phases based on poly(dimethylsiloxane) immobilized on silica.

This work describes the preparation and characterization of six stationary phases for high-performance liquid chromatography (HPLC) obtained by deposition of poly(dimethylsiloxane) (PDMS) in HPLC silica particles, followed by immobilization using different processes (thermal treatments, thermal treatment + microwave irradiation, self-immobilization + gamma irradiation and self-immobilization + microwave irradiation). The chromatographic parameters of all the phases were evaluated with a mixture of test compounds having varied natures (acid, basic and neutral). The stability of one of these phases was evaluated in both a neutral mobile phase and a higher pH mobile phase used at an elevated temperature, with promising results.

Chromatography, High Pressure Liquid↗

Titanized silicas, modified by C18, as promising stationary phases for high pH separations.

To enhance the high pH stability of silica based reversed phases, chemically bonded octadecyl phases were prepared through silanization of titanized silica particles containing approximately 14% titanium oxide on the surface. The present work describes some spectroscopic characterizations using infrared, solid-state 13C and 29Si nuclear magnetic resonance (NMR) and X-ray absorption spectroscopy (XAS). Chromatographic characterizations for the titanized phase as well as for a conventional C18 phase, based on the same silica support without titanization, are also described using three different test mixtures containing neutral, polar and basic compounds. After an artificial stability test at pH 10, the titanized phase was again characterized by elemental and X-ray fluorescence analyses to determine the remaining carbon and titanium contents. As an application to real world samples, the separation of some herbicides and highly basic drugs using buffered mobile phases are also shown.

Chromatography, Ion Exchange↗

High-performance liquid chromatographic determination of pesticides in tomatoes using laboratory-made NH2 and C18 solid-phase extraction materials.

A method for high-performance liquid chromatographic (HPLC) multiresidue determination of six pesticides in tomatoes was developed and validated. Silica-based C18 (octadecyl) and NH2 (aminopropyl) solid-phase extraction (SPE) sorbents, made in our laboratory, were used for sample preparation. The SPE materials were obtained by thermal immobilization of appropriate polysiloxanes onto 40 microm silica surfaces and were used in sample preparation for multiresidue analysis of the following pesticides: tebuthiuron and diuron (urea herbicides), simazine, atrazine and ametryn (triazines herbicides) and benomyl (benzimidazol fungicide). The results were compared with similar commercial materials. Reversed-phase high-performance liquid chromatography (RP-HPLC) using a Purospher RP-18 5 microm column and ACN: 0.01% aqueous NH4OH, pH 8.4 (35:65, v/v) as mobile phase, at 0.7 mlmin(-1), with 235 nm UV detection, was used for separation and quantification of the pesticides. Method validation was performed at three fortification levels (100, 200, 1000 microg l(-1)). Limits of detection and quantification show that the methods developed can be used to detect the pesticides in concentrations below the maximum residue levels (MRL) established by the Codex Alimentarius, USA, European Union and Brazilian legislations. The results showed that aminopropyl materials have a better performance than the octadecyl sorbents. Laboratory-made materials give results similar to commercial sorbents, with recoveries and precisions in agreement with directives for method validation in residue analysis.

Chromatography, High Pressure Liquid↗

New stationary phase for anion-exchange chromatography.

This work describes the preparation of an anion-exchange phase based on silica, using a two-step modification process. First, 10 microm Davisil silica particles were silanized with chloropropyltrimethoxysilane to yield chloropropyl silica. The modified silica was then reacted with pyridine to produce positively charged propylpyridinium groups on the surface, the anion-exchange sites. The phase was characterized by thermogravimetric analysis and infrared and solid state 13C and 29Si NMR spectroscopies. HPLC separations of common inorganic anions, including chloride, nitrite, bromide and nitrate, were performed using 150 x 3.9 HPLC columns packed with the phase, using a phthalate buffer solution as mobile phase with non-suppressed conductivity detection. Efficiency and resolution were calculated and the results show that the new phase has significant promise for the analysis of these anions in environmental samples.

Anion Exchange Resins↗

Direct determination of diclofenac in pharmaceutical formulations containing B vitamins by using UV spectrophotometry and partial least squares regression.

This work proposes a simple and rapid analytical procedure for determination of diclofenac (DCF) in the presence of B vitamins, based on UV measurements and partial least squares (PLS). The interference of thiamine (THI) and pyridoxine (PYR) were modelled using an experimental design constructed in the ranges of 10-50 micromoll(-1) for DCF and THI and 15-75 micromoll(-1) for PYR. The procedure was repeated at five different pH values (between 3 and 6) and the best results were observed at pH 5, presenting a root mean square error of prediction (RMSEP) of 0.80 micromoll(-1) for DCF. The procedure was successfully applied to simultaneous determination of DCF, THI and PYR in synthetic mixtures and in a pharmaceutical formulation that contains a simple excipient (lactose). For determination of a more complex formulation that contains 15 different substances in the excipient, including some UV absorbing ones, the procedure was only able to determine DCF, since the excipient interferences disturbed THI and PYR predictions. Figures of merit, such as selectivity, analytical sensitivity, limit of detection and precision were determined for the DCF prediction model and the determinations were verified by an independent method, HPLC.

Chemistry, Pharmaceutical↗

New materials for solid-phase extraction and multiclass high-performance liquid chromatographic analysis of pesticides in grapes.

Sample preparation procedures which included the use of new aminopropyl (NH2) and octadecyl (C18) solid-phase extraction (SPE) sorbents are proposed for the simultaneous multiclass determination of the fungicide benomyl and of the herbicides tebuthiuron, diuron, simazine, atrazine, and ametryn in grapes, using single wavelength high-performance liquid chromatography. Sorbent preparation uses a fast, easy, and effective procedure to obtain silica-based materials, made by depositing polysiloxanes on a silica support followed by thermal immobilization. Recovery results of the compounds, after elution from the SPE cartridges, indicate that the most efficient system employed silica loaded with 40% of an aminofunctional polydimethylsiloxane as sorbent, using dichloromethane:methanol (95:5, v/v) as eluent. Method validation, carried out in agreement with International Conference on Harmonization directives, was performed at three fortification levels (100, 200, and 1000 microg kg(-1)). Limits of detection and quantification show that the method developed can be used to detect the pesticides at concentrations below the maximum residue levels established by Codex Alimentarius, the US Environmental Protection Agency, the European Union, and Brazilian legislation.

Chromatography, High Pressure Liquid↗

Self-immobilization and/or thermal treatment for preparing silica-poly(methyloctylsiloxane) stationary phases.

Batches of poly(methyloctylsiloxane) (PMOS)-loaded silica were prepared by the deposition of PMOS, into the pores of HPLC silica. Portions of PMOS-loaded silica were allowed to remain at ambient temperature, without further treatment for 2, 9, 20, 31, 51, 105 and 184 days after preparation to undergo self-immobilization (irreversible adsorption of a layer of polymer on silica at ambient temperature in the absence of initiators). Other portions were subjected to a thermal treatment (100 degrees C for 4h) after 1, 2, 5, 7, 9, 15, 20, 25, 70, 111 and 184 days. Self-immobilized and thermally treated samples were characterized by % C, 29Si cross-polarization magic angle spinning (CP/MAS) NMR spectroscopy and reversed-phase column performance. The results show that thermal immobilization accelerates the distribution and rearrangement of the polymer on the silica surface. However, from the time that a monolayer has been formed by self-immobilization (approximately 100 days for PMOS on Kromasil silica), the thermal treatment does not alter this configuration and, thus, does not change the resulting chromatographic parameters.

Magnetic Resonance Spectroscopy↗

Chromatographic and column stability at pH 7 of a C18 dimethylurea polar stationary phase.

Chromatographic evaluations of a C18 dimethylurea phase in 150 mm x 3.9 mm HPLC columns were performed using the Tanaka and Engelhardt test mixtures. The applicability of the new C18 dimethylurea phase was also evaluated with a mixture of some herbicides and their metabolites. An artificial aging procedure was also performed by passing a potassium phosphate mobile phase buffered at pH 7.0 through C18 50 mm x 3.9 mm dimethylurea columns. The column stability was evaluated by means of the chromatographic parameters obtained for the separation of some compounds from the Neue test mixture, using apolar, polar and highly basic analytes.

Chromatography, High Pressure Liquid↗

Titanized silica-based stationary phases prepared with thermally and microwave-immobilized poly(methyloctylsiloxane).

Silica supports having their surface modified with titanium oxide were prepared and coated with poly(methyloctylsiloxane) (PMOS). Subsequently, immobilization of the polysiloxane was induced by thermal treatment or microwave radiation. The thermal treatment was carried out for different times (4, 8, 16 and 24 h) at temperatures ranging between 100 and 220 degrees C. For PMOS immobilization by microwave radiation, 452, 520 and 586 W power levels and exposure times of 5, 15 and 30 min were used. After extraction of non-immobilized polymer, the chromatographic properties of the phases were evaluated. The phase immobilized at 120 degrees C for 8 h presented the best chromatographic parameters, suggesting that the quantity of acidic hydroxyl groups on the support surface was reduced, resulting in fewer undesirable interactions of a basic solute with the silanols not removed or covered on the support surface.

Chromatography, Liquid↗