PubMed Health⌕ Search

Biomedical subjects

Caroline Majoral

Publications and source records attributed to Caroline Majoral.

3 recordsLinked to original sources

Lung deposition of HFA beclomethasone dipropionate in an animal model of bronchopulmonary dysplasia.

The best delivery of a drug in ventilated neonates is obtained when using a small particle diameter solution administered via a spacer. Lung deposition of hydrofluoroalkane beclomethasone dipropionate (QVAR, 1.3 microm particles), delivered via an Aerochamber-MV15, was measured in piglets under conditions mimicking ventilated severely ill neonates (uncuffed 2.5 mm endotracheal tube; peak pressure 16 cm H2O; respiratory rate 40/min). After determining the mass and particle size distribution of the 99mTc-labeled and unlabeled drug, three lung deposition studies were performed: after 1 h of ventilation (controls, n = 18), after 48 h aggressive ventilation inducing an acute lung injury (nine piglets out of the controls), and after increasing the pressure to 24 cm H2O during drug delivery (five piglets out of the nine with acute lung injury). All piglets were then killed for lung histology. Results (median, range), expressed as a percentage of the delivered dose, were compared using an inferential or the Friedman test. While lung deposition was low, it was greater (p = 0.003) in controls (2.66%, 0.50-7.70) than in piglets with histologically confirmed acute lung injury (0.26%, 0.06-1.28) or under a high-pressure ventilation (1.01%, 0.30-2.15). Lung deposition of QVAR in an animal model of ventilated neonates is low, variable, and dramatically affected by lung injury.

Aerosol Propellants↗

New ipratropium formulation to decrease nebulization time.

A new anticholinergic aerosol containing 0.5mg ipratropium bromide dissolved in 1mL of solution has been produced with the purpose of decreasing nebulization time for patients compared to the traditional formulation which is twice as voluminal (0.5mg/2mL, Boehringer-Ingelheim, France). The aim of this study was to compare aerosol characteristics (inhaled mass, particle size distribution and nebulization time) of these two formulations of ipratropium bromide, nebulized alone and with terbutaline (5mg/2mL, Astra Zeneca, Sweden), to determine whether the new formulation was equivalent to the old one. Four different jet nebulizers were used: PariLC+, Atomisor NL9M, Sidestream and Mistyneb. Statistical analysis of the results showed that for all types of nebulizer, the inhaled mass of ipratropium bromide 0.5mg/1mL was significantly lower than the inhaled mass of ipratropium bromide 0.5mg/2mL, and that there was no statistical difference between the inhaled mass of ipratropium bromide 0.5mg/1mL+terbutaline 5mg/2mL and the inhaled mass of ipratropium bromide 0.5mg/2mL+terbutaline 5mg/2mL. The study also showed that the new formulation of ipratropium bromide (0.5mg/1mL) mixed with terbutaline allowed a 26% decrease in nebulization time compared to the old formulation (0.5mg/2mL) mixed with terbutaline without changing aerosol characteristics (inhaled mass and particle size distribution). This leads to the conclusion that a 2mL minimum volume is required for nebulization, and that nebulization of ipratropium bromide 0.5mg/1mL alone must be avoided.

Aerosols↗

Gemcitabine aerosol: in vitro antitumor activity and deposition imaging for preclinical safety assessment in baboons.

AIM: To characterize gemcitabine aerosol, its in vitro activity against lung cancer cells, its deposition, and tolerance in a non-human primate model. METHODS: In vitro cytotoxicity of nebulized gemcitabine against NCI-H460 and A549 lung cancer cells was tested using a growth inhibition assay and compared with non-nebulized gemcitabine. The (99m)Tc-DTPA-radiolabeled gemcitabine aerosol was characterized by cascade impaction and the gemcitabine mass/(99m)Tc activity relationship was established for further quantitative nuclear imaging. Nine weekly inhalations at a target dose of 1 mg/kg body weight of gemcitabine were performed in three baboons using dynamic scintigraphic acquisitions for continuous monitoring of gemcitabine delivery during inhalation. Gemcitabine plasma concentrations were measured during the first inhalation. RESULTS: Growth inhibition assays for both NCI-H460 and A549 cells did not differ between nebulized and non-nebulized gemcitabine. Aerosol characterization showed a particle mass median aerodynamic diameter of 3.7+/-0.8 microm and a linear relationship between gemcitabine mass (y) and (99m)Tc activity (x) (y=0.82x - 10(-5), R (2)=0.88). No toxicity was observed after nine weekly inhalations of a mean dose of gemcitabine of 11.1 mg (88% of the target dose) as assessed from scintigraphic data. A dose-dependent peak plasma concentration of gemcitabine (20-74 ng/ml) was observed by the tenth minute of inhalation. CONCLUSIONS: We have characterized a gemcitabine aerosol suitable for intrathoracic airway deposition and demonstrated that jet nebulization does not alter the cytotoxic properties of the drug. In a primate model, we have developed a scintigraphic procedure for the monitoring of aerosol deposition, and we have demonstrated the safety of nine weekly aerosol administrations of gemcitabine.

Aerosols↗