PubMed Health⌕ Search

Biomedical subjects

Carolyn F Small

Publications and source records attributed to Carolyn F Small.

4 recordsLinked to original sources

Mechanical properties of the scapholunate ligament correlate with bone mineral density measurements of the hand.

The mechanical properties of the scapholunate ligament have been previously examined in small sample sizes, with ultimate load and occasionally stiffness reported. The present study examined 16 scapholunate ligaments in uniaxial extension at two rates and determined stiffness, ultimate load, and stress relaxation properties. Mean stiffness values of 66.4+/-28.6 N/mm at an elongation rate of 50 mm/min and 94.5+/-44.4 N/mm at an elongation rate of 100 mm/min were found. Relaxation behavior, determined by the percent load remaining after 100 s, was found to be 68.1+/-12%. Mean ligament ultimate loads were 357+/-110 N (n = 8). In eight specimens, failure occurred in bone. Positive correlations were observed between bone mineral density of the hand and ligament stiffness, ligament ultimate load, and bone ultimate load. No correlation was observed between bone mineral density and ligament load relaxation behavior. The results provide a comprehensive understanding of scapholunate ligament biomechanics and demonstrate a relationship between bone and ligament properties.

Absorptiometry, Photon↗

Computer-assisted distal radius osteotomy.

PURPOSE: To establish the accuracy, precision, and clinical feasibility of a novel technique of computer-assisted distal radius osteotomy for the correction of symptomatic distal radius malunion. METHODS: Six patients underwent a computer-assisted distal radius osteotomy and were followed-up for an average of 25 months. Objective radiographic measurements and functional outcomes, as measured by clinical examination including grip strength and range of motion, and Disability of the Arm, Shoulder and Hand (DASH) questionnaires, were used. RESULTS: The mean radiographic parameters included an increase of radial inclination to 21 degrees from 12 degrees (normal, 23 degrees ). Dorsal and volar tilt (malunion) were corrected to 9 degrees from -30 degrees and 21 degrees, respectively (normal, 10 degrees ). Ulnar variance was corrected to 1.9 mm from 7.5 mm (normal, +1.5 mm). Normal is defined as the average of the contralateral limb radiographs. The mean clinical outcome measures at an average of 25 months included a DASH global score of 14, a DASH individual item average score of 1.6, and an average affected side grip strength of 79% when compared with the unaffected side. CONCLUSIONS: The results of the computer-assisted technique were comparable with published results of traditional non-computer-assisted opening wedge osteotomy techniques. This technique allows a surgeon to accurately and precisely recognize and correct 3-dimensional deformities of the distal radius including axial malalignment (supination). The technique has the added benefit of reducing radiation exposure to the patient and surgical team because fluoroscopy is not used during the procedure. Additional benefits of the computer-assisted technique include the ability to perform multiple surgical simulations to optimize the alignment plan, and it serves as an excellent teaching tool for less-experienced surgeons.

Adult↗

Development of a three-dimensional finite element model for carpal load transmission in a static neutral posture.

A three-dimensional developmental finite element model has been created to analyze load transmission pathways in the constrained carpus during static compressive loading. The bone geometry was extracted from an in vivo computed tomography scan using a combination of commercial and proprietary software. The complete geometry, including bone, cartilage, and ligament tissues, was compiled using a commercial finite element program. This model extends the state of biomechanical modeling by being the first to incorporate all eight carpal bones of the wrist and the related soft tissues in three dimensions. The model results indicate that cartilage material modulus and unconstrained carpal rotation have substantial impacts on the articular contact patterns and pressures.

Algorithms↗

The sensitivity of carpal bone indices to rotational malpositioning.

We investigated the dependence of 20 radiographic carpal measurements (carpal indices) on rotational positioning errors in posteroanterior and lateral radiographs. The measurements were made from "true perspective" digitally reconstructed radiographs created from computed tomography data. Most posteroanterior indices were not affected by rotation. Carpal height, carpal height ratio, revised carpal height ratio, capitate-radius distance, and carpal ulnar translocation were particularly robust. Lateral-view indices involving the scaphoid were the most sensitive to simulated malpositioning: radioscaphoid, scapholunate, and scaphocapitate angles were reduced from 58 degrees, 48 degrees, and 56 degrees at true lateral to 30 degrees, 24 degrees, and 34 degrees, respectively, at 20 degrees external rotation. Observers were unable to estimate the degree of malpositioning accurately in either view. Our results support use of the "scaphopisocapitate" criterion for assessing correct positioning in lateral plain radiographs.

Adult↗