PubMed Health⌕ Search

Biomedical subjects

Carolyn M Webb

Publications and source records attributed to Carolyn M Webb.

5 recordsLinked to original sources

Comparison of flow characteristics and vascular reactivity of radial artery and long saphenous vein grafts [NCT00139399].

BACKGROUND: The morphological and functional differences between arteries and veins may have implications on coronary artery bypass graft (CABG) survival. Although subjective differences have been observed between radial artery (RA) and long saphenous venous (LSV) grafts, these have not been quantified. This study assessed and compared the flow characteristics and in-vivo graft flow responses of RA and LSV aorto-coronary grafts. METHODS: Angiograms from 52 males taken 3.7 +/- 1.0 months after CABG surgery were analyzed using adjusted Thrombolysis in Myocardial Infarction (TIMI) frame count. Graft and target coronary artery dimensions were measured using quantitative coronary angiography. Estimated TIMI velocity (V(E)) and volume flow (F(E)) were then calculated. A further 7 patients underwent in-vivo graft flow responses assessments to adenosine, acetylcholine and isosorbide dinitrate (ISDN) using intravascular Doppler. RESULTS: The V(E) for RA grafts was significantly greater than LSV grafts (P = 0.002), however there was no difference in volume F(E) (P = 0.20). RA grafts showed positive endothelium-dependent and -independent vasodilatation, and LSV grafts showed no statistically significant response to adenosine and acetylcholine. There was no difference in flow velocity or volume responses. Seven RA grafts (11%) had compromised patency (4 (6%) > or = 50% stenosis in the proximal/distal anastomoses, and 3 (5%) diffuse narrowing). Thirty-seven (95%) LSV grafts achieved perfect patency and 2 (5%) were occluded. CONCLUSION: The flow characteristics and flow responses of the RA graft suggest that it is a more physiological conduit than the LSV graft. The clinical relevance of the balance between imperfect patency versus the more physiological vascular function in the RA graft may be revealed by the 5-year angiographic follow-up of this trial.

Acetylcholine↗

Normal coronary physiology assessed by intracoronary Doppler ultrasound.

There is a natural need to measure flow in normal as well as diseased coronary arteries since the reestablishment of normal flow is the aim of most coronary interventions. Miniaturization has enabled positioning both proximal and distal within the coronary anatomy and improved accuracy of Doppler velocity measurements. Measurement of coronary flow reserve adds functional data to coronary angiographic anatomic description, and quantitation of flow, achieved by combining Doppler velocity. Although new techniques involving transthoracic Doppler and magnetic resonance imaging are currently being developed and refined to measure coronary flow velocity and volume flow noninvasively, the role of intracoronary Doppler remains secure particularly for the coronary interventional physician.

Blood Flow Velocity↗

Long-term use of contraceptive depot medroxyprogesterone acetate in young women impairs arterial endothelial function assessed by cardiovascular magnetic resonance.

BACKGROUND: Depot medroxyprogesterone acetate (DMPA) inhibits proliferation of ovarian follicles, resulting in anovulation and a decrease in circulating estrogen; the latter action is potentially disadvantageous to cardiovascular health. We therefore investigated the vascular effects of long-term contraceptive DMPA in young women. METHODS AND RESULTS: Endothelium-dependent (hyperemia-induced flow-mediated dilatation [FMD]) and -independent (glyceryl trinitrate [GTN]) changes in brachial artery area were measured using cardiovascular magnetic resonance in 13 amenorrheic DMPA users (>1 year use; mean age 29+/-4 years) and in 10 controls (mean age 30+/-4 years, P=0.25) with regular menstrual cycles after validation of the technique. FMD and GTN responses were measured just before repeat MPA injection and 48 hours later (n=12) in DMPA users and during menstruation and midcycle (n=9) in controls. Serum-estradiol levels (S-estradiol) were measured at both visits. FMD was reduced in DMPA users compared with controls during menstruation (1.1% versus 8.0%, respectively P<0.01) without differences in GTN responses. S-estradiol levels in DMPA users were significantly lower than in controls during menstruation (58 versus 96 pmol/L, P<0.01). High levels of circulating MPA 48 hours after injection were not linked to an additional impairment in FMD (2.0% versus 3.1%, P=0.23). Estradiol levels were significantly correlated to FMD (r=0.43, P<0.01). CONCLUSIONS: Endothelium-dependent arterial function measured by cardiovascular magnetic resonance is impaired in chronic users of DMPA, and hypoestrogenism may be the mechanism of action. DMPA might adversely affect cardiovascular health, and in particular its use in women with cardiovascular disease should be additionally evaluated.

Adult↗

Assessment of endothelial function using peripheral waveform analysis: a clinical application.

OBJECTIVES: The study was done to determine whether radial artery applanation tonometry can be used as a noninvasive method of assessing global endothelial function. BACKGROUND; It is known that beta(2)-receptor stimulation results in endothelial release of nitric oxide. Furthermore, for over a century glyceryl trinitrate (GTN) has been known to markedly affect the arterial pressure waveform, even in the absence of significant blood pressure (BP) changes. Therefore, it was hypothesized that the change in the peripheral pressure waveform, as measured using tonometry and quantified using the augmentation index (AIx) and in response to Salbutamol (Salb), would allow assessment of global endothelial function. METHODS: The study contained three parts. In the first study, Salb (400 microg) was administered to 11 healthy subjects via inhalation after either intravenous N-omega-nitro-monomethyl-L-arginine (L-NMMA) (3 mg/kg over 5 min) or control solution (normal saline) in the supine, rested, fasted condition. The BP, heart rate and waveform responses were recorded each 5 min following Salb for 20 min. Next, GTN was given and responses recorded 5 min later. In the second study, both the reproducibility of Salb and the GTN responses were assessed in 9 subjects studied twice on separate days. In the third study, the Salb and GTN responses of 12 subjects with angiographic coronary artery disease (CAD) were compared with 10 age-matched control subjects with no atherosclerotic risk factors. RESULTS: After control infusion, AIx decreased following Salb, from 50.8 +/- 4.3% to 44.8 +/- 4.2%, a change of -11.8 +/- 3.7%, p < 0.01. After L-NMMA, AIx did not significantly change following Salb (54.2 +/- 5.1% vs. 52.9 +/- 5.3%, -2.0 +/- 3.1%). The GTN-induced decreases in AIx were similar after either infusion (35.1 +/- 3.3% vs. 36.5 +/- 3.3%). Reproducibility of Salb-induced changes in AIx between studies performed on separate days was good (r = 0.80, p < 0.01). Salb-induced changes in AIx in CAD patients were significantly less compared to control subjects (-2.4 +/- 1.9% vs. -13.2 +/- 2.4%, respectively, p < 0.002). The GTN-induced changes were not significantly different (-27.6 +/- 4.2 vs. -38.9 +/- 4.4%, p = 0.07). CONCLUSIONS: The peripheral arterial pressure waveform is sensitive to beta(2)-stimulation. Changes are related to nitric oxide release, are reproducible and can distinguish between clinical subject groups. Arterial waveform changes following Salb may thus provide a noninvasive method of measuring "global" arterial endothelial function.

Adrenergic beta-Agonists↗

A comparison of brachial artery reactivity measured by external and intravascular ultrasound.

External ultrasound (US), EXUS, is widely used to measure brachial artery (BA) diameter changes in the assessment of vascular function; however, it has not been compared with other imaging modalities. We simultaneously measured BA diameter responses to hyperaemic flow and nitrate using EXUS and intravascular ultrasound (US), IVUS, in 10 patients. Mean diameters measured across all time periods correlated closely (r = 0.67, p < 0.001). Percent diameter change to hyperaemia and nitrate also correlated well (r = 0.67, p < 0.01). IVUS cross-sectional area (CSA) was significantly different from that calculated from EXUS using pir(2) (23.95 +/- 4.89 vs. 20.35 +/- 4.51 mm(2), respectively, p < 0.001). Orthogonal diameters measured by IVUS were significantly different (5.45 +/- 0.85 vs. 5.17 +/- 0.79 mm, respectively, p < 0.005). In conclusion, EXUS and IVUS BA diameter measurements correlated well; however, discrepancies in absolute measurements were revealed. The cross-section of the BA is oval; therefore, deriving CSA by pir(2) is inaccurate.

Adult↗