Dual-source CT cardiac imaging: initial experience.

The relation of heart rate and image quality in the depiction of coronary arteries, heart valves and myocardium was assessed on a dual-source computed tomography system (DSCT). Coronary CT angiography was performed on a DSCT (Somatom Definition, Siemens) with high concentration contrast media (Iopromide, Ultravist 370, Schering) in 24 patients with heart rates between 44 and 92 beats per minute. Images were reconstructed over the whole cardiac cycle in 10% steps. Two readers independently assessed the image quality with regard to the diagnostic evaluation of right and left coronary artery, heart valves and left ventricular myocardium for the assessment of vessel wall changes, coronary stenoses, valve morphology and function and ventricular function on a three point grading scale. The image quality ratings at the optimal reconstruction interval were 1.24+/-0.42 for the right and 1.09+/-0.27 for the left coronary artery. A reconstruction of diagnostic systolic and diastolic images is possible for a wide range of heart rates, allowing also a functional evaluation of valves and myocardium. Dual-source CT offers very robust diagnostic image quality in a wide range of heart rates. The high temporal resolution now also makes a functional evaluation of the heart valves and myocardium possible.

Algorithms↗

High-resolution ex vivo imaging of coronary artery stents using 64-slice computed tomography--initial experience.

The aim of the study was to evaluate the potential of new-generation multi-slice computed tomography (CT) scanner technology for the delineation of coronary artery stents in an ex vivo setting. Nine stents of various diameters (seven stents 3 mm, two stents 2.5 mm) were implanted into the coronary arteries of ex vivo porcine hearts and filled with a mixture of an iodine-containing contrast agent. Specimens were scanned with a 16-slice CT (16SCT) machine; (Somatom Sensation 16, Siemens Medical Solutions), slice thickness 0.75 mm, and a 64-slice CT (64SCT, Somatom Sensation 64), slice-thickness 0.6 mm. Stent diameters as well as contrast densities were measured, on both the 16SCT and 64SCT images. No significant differences of CT densities were observed between the 16SCT and 64SCT images outside the stent lumen: 265+/-25HU and 254+/-16HU (P=0.33), respectively. CT densities derived from the 64SCT images and 16SCT images within the stent lumen were 367+/-36HU versus 402+/-28HU, P<0.05, respectively. Inner and outer stent diameters as measured from 16SCT and 64SCT images were 2.68+/-0.08 mm versus 2.81+/-0.07 mm and 3.29+/-0.06 mm versus 3.18+/-0.07 mm (P<0.05), respectively. The new 64SCT scanner proved to be superior in the ex vivo assessment of coronary artery stents to the conventional 16SCT machine. Increased spatial resolution allows for improved assessment of the coronary artery stent lumen.

Animals↗

Assessment of coronary artery stent patency and restenosis using 64-slice computed tomography.

RATIONALE AND OBJECTIVES: Restenosis remains a major limitation of coronary catheter-based stent placement. Therefore, a reliable noninvasive diagnostic method for the evaluation of stented coronary arteries would be highly desirable. Our aim was to evaluate the diagnostic accuracy of high-resolution 64-slice computed tomography (64SCT) in a pilot study for the assessment of the lumen of coronary artery stents. MATERIALS AND METHODS: Twenty-five patients underwent 64SCT of the coronary arteries and quantitative x-ray coronary angiography (QCA) after coronary artery stent placement. 64SCT coronary angiography was performed with the following parameters: spatial resolution = 0.4 x 0.4 x 0.4 mm; temporal resolution = 83-165 milliseconds; contrast agent = 80 mL at a flow rate of 5 mL/second; retrospective electrocardiogram gating. The 64SCT scans were evaluated for image quality and for the presence of significant in-stent and peri-stent (proximal and distal) stenoses. Determinations were made of the sensitivity, specificity, diagnostic accuracy, and positive and negative predictive values (PPV and NPV) of 64SCT for the detection or exclusion of stenoses. RESULTS: A total of 46 stents were evaluated, of which 45 (98%) were of diagnostic image quality. Significant in-stent restenosis or occlusion was detected on QCA in 8/45 cases (>/=50% stenosis = 6; occlusion = 2). The sensitivity, specificity, accuracy, PPV, and NPV of 64SCT for the detection of significant in-stent disease was 75%, 92%, 89%, 67%, and 94%, respectively. Both occluded coronary artery stents were correctly identified. The sensitivity, specificity, and accuracy values of 64SCT for the detection of significant proximal peri-stent stenoses were 75%, 95%, and 93%, respectively, whereas the values for detection of significant distal peri-stent stenoses were 67%, 85%, and 84%, respectively. CONCLUSION: The high spatial and temporal resolution of 64SCT may permit improved assessment of stent occlusion and peri-stent disease, although detection of in-stent stenosis remains difficult.

Adult↗

Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed.

OBJECTIVES: We sought to evaluate the impact of patients' heart rate (HR) on coronary CTA image quality (IQ) and motion artifacts using a 64-slice scanner with 0.33/360 degrees rotation. MATERIALS AND METHODS: Coronary CTA data sets of 32 patients (HR 65 bpm to 75 bpm, n = 7) examined on a 64-slice scanner (Sensation 64, Siemens Medical Solutions, Forchheim, Germany) with 0.33s/360 degrees gantry rotation speed were analyzed. All patients had suspicion of coronary artery disease. Data acquisition was performed using 64 x 0.6-mm collimation, and contrast enhancement was provided by injection of 80 mL of iopromide (5 mL/s + NaCl). Images were reconstructed throughout the RR interval using half-scan and dual-segment reconstruction. IQ was rated by 2 observers using a 3-point scale from excellent (1) to nondiagnostic (3) for coronary segments. Quality was correlated to the HR, time point of optimal IQ analyzed, and the benefit of dual-segment reconstruction evaluated. RESULTS: Overall mean IQ was 1.31 +/- 0.32 for all HR, with IQ being 1.08 +/- 0.12 for HR 65 bpm 75 bpm (P = 0.0003). Dual-segment reconstruction did not significantly improve IQ in any HR group (P = NS). Mean IQ was significantly better for LAD than for RCA (P < 0.0001) and LCX (P < 0.01). A total of 3.5% (11/318) of coronary artery segments were rated nondiagnostic by at least one reader based on motion artifacts. Although in HR < 65 bpm, the best IQ was predominately in diastole (93%), in HR > 75 bpm, the best IQ shifted to systole in most cases (86%). CONCLUSIONS: Temporal resolution at 0.33-second rotation allows for diagnostic IQ within a wide range of HR using half-scan reconstruction. With increasing HR the time point of best IQ shifts from mid-diastole to systole.

Adult↗

Contrast bolus optimization for cardiac 16-slice computed tomography: comparison of contrast medium formulations containing 300 and 400 milligrams of iodine per milliliter.

OBJECTIVES: The aims of our study were to compare contrast injection protocols with contrast media containing 300 and 400 mg iodine per milliliter for optimal contrast enhancement in cardiac multidector row computed tomography (CT) and to evaluate the correlation of test bolus curve parameters with the final contrast density of the main bolus. MATERIALS AND METHODS: Sixty patients with known or suspected coronary artery disease were included in a prospective double-blind study. Patients were randomized to 2 groups. Group 1 received 83 mL of a contrast medium (CM) containing 300 mg of iodine (Iomeron 300, Bracco Imaging SpA, Milan, Italy) at a flow rate of 3.3 mL/s, whereas group 2 received 63 mL of the same agent containing 400 mg of iodine (Iomeron 400) at a flow rate of 2.5 mL/s. The test bolus volumes were 20 mL and 15 mL, respectively. Imaging was performed using a 16-slice CT system (16DCT; Somatom Sensation 16, Siemens Medical Solutions, Forchheim, Germany). Contrast densities (Hounsfield Units [HU]) were determined in the cardiac chambers and in the main coronary arteries. The peak density and area under the curve of the test bolus were calculated for each patient. RESULTS: The mean contrast densities of the coronary arteries were 259.1 +/- 46.7 HU for group 1 and 251.6 +/- 51.0 HU, for group 2. No noteworthy differences between groups were noted for density measurements in the cardiac chambers or for the ratio of right-to-left ventricle density. Whereas a positive correlation was noted for both groups between the area under the curve of the test bolus and the mean density of the main bolus, a positive correlation between peak density of the test bolus and mean density of the main bolus was noted only for group 1. CONCLUSION: Equivalent homogenous enhancement of the ventricular cavities and coronary arteries to that obtained using a CM with standard iodine concentration (Iomeron 300) can be achieved with lower overall volumes of administered CM and reduced injection flow rates when a CM with high iodine concentration (Iomeron 400) is used.

Adult↗

Clinical value of MDCT in the diagnosis of coronary artery disease in patients with a low pretest likelihood of significant disease.

OBJECTIVE: The aim of this study was to evaluate the clinical value of MDCT in the diagnosis of coronary artery disease in a population having a low pretest likelihood of significant disease. SUBJECTS AND METHODS: Sixty-four patients with suspected coronary artery disease and a low pretest likelihood of significant disease according to the criteria of the American Heart Association underwent both MDCT of the heart and quantitative conventional coronary angiography (QCA). MDCT examinations were performed on a 16-MDCT scanner. CT data sets were evaluated on a per-patient basis and a per-segment basis and were classified as indicating no disease, nonsignificant disease (stenoses </= 50%), or significant disease (stenoses > 50%). Sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) of 16-MDCT in the detection or exclusion of significant and nonsignificant coronary artery disease were evaluated on both per-patient and per-segment bases. RESULTS: Regarding the success rate of 16-MDCT, 94% (60/64) of patients and 92% (388/420) of vessel segments were of sufficient quality for diagnosis. In the remaining 60 patients evaluated, QCA revealed significant coronary artery disease, nonsignificant disease, and no disease in 8.3% (5/60), 75.0% (45/60), and 16.7% (10/60) of cases, respectively, on a per-patient basis, and in 1.3% (5/388), 23.2% (90/388), and 75.5% (293/388) of cases, respectively, on a per-segment basis. The sensitivity, specificity, NPV, and PPV of 16-MDCT for the detection of significant coronary artery disease were 80.0%, 94.5%, 98.1%, and 57.1%, respectively, on a per-patient basis, and 80.0%, 99.2%, 99.7%, and 57.1% on a per-segment basis. CONCLUSION: In a population having a low pretest likelihood of significant coronary artery disease, 16-MDCT shows a moderate to high sensitivity and high NPV for the detection or exclusion of significant disease, but has a somewhat reduced PPV compared with QCA.

Adult↗

Accuracy of 64-MDCT in the diagnosis of ischemic heart disease.

OBJECTIVE: The aim of this study was to evaluate the potential clinical value of a new generation of 64-MDCT systems with that of invasive coronary angiography in the diagnosis of coronary artery disease (CAD). SUBJECTS AND METHODS: Seventy-two consecutive patients with known or suspected CAD underwent both 64-MDCT and quantitative coronary angiography (QCA). A CT system with acquisition of 64 slices per gantry rotation was used with a spatial resolution of 0.4 x 0.4 x 0.4 mm and a gantry rotation time of 330 milliseconds. Sensitivity, specificity, and diagnostic accuracy of 64-MDCT in the detection or exclusion of CAD were evaluated on both a per patient and a per segment basis. RESULTS: Sixty-eight of 72 coronary CT angiograms (CTAs) (94%) were of diagnostic image quality. QCA showed significant CAD (i.e., one or more stenoses in > 50%) in 57% (39/68) and nonsignificant disease or healthy CTAs in 43% (29/68) of the patients. Sensitivity, specificity, and the negative predictive value (NPV) of 64-MDCT per patient were 97%, 79%, and 96%, respectively. Per segment, 923 of 1,020 coronary artery segments were assessable (90%). For the detection of stenoses of more than 50% and more than 75% per segment, 64-MDCT showed a sensitivity of 82% and 86%, respectively. Per segment, specificity and NPV were as high as 95% and 97%, respectively. CONCLUSION: In clinical routine, coronary CTA will primarily be used for risk stratification on a per patient basis. In the present study, coronary 64-MDCT showed a high diagnostic accuracy on both per patient and per segment analyses.

Adult↗

Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound.

OBJECTIVES: We evaluated the accuracy of contrast-enhanced multidetector spiral computed tomography (MDCT) for the noninvasive detection and classification of coronary plaques and compared it with intracoronary ultrasound (ICUS). BACKGROUND: Noninvasive determination of plaque composition and plaque burden may be important to improve risk stratification and to monitor progression of coronary atherosclerosis. METHODS: We included 46 consecutive patients with a distinctive risk profile, who were investigated by ICUS (Goldvision, 20 MHz, Jomed Inc., Rancho Cordova, California). Due to the inability to slow the heart rate below 65 beats/min (n = 7) and due to renal insufficiency (n = 2), nine of 46 consecutive patients could not be studied by MDCT (Sensation 16, Siemens, Forchheim, Germany). RESULTS: In the remaining 37 patients, 68 vessels were investigated by ICUS, and 58 of these vessels were visualized by MDCT with image quality sufficient for analysis. In these vessels that were divided in 3-mm sections, MDCT correctly classified 62 of 80 (78%) sections containing hypoechoic plaque areas, 87 of 112 (78%) sections containing hyperechoic plaque areas, and 150 of 158 (95%) sections containing calcified plaque tissue. In 484 of 525 (92%) sections, atherosclerotic lesions were correctly excluded. The MDCT-derived density measurements within coronary lesions revealed significantly different values for hypoechoic (49 HU [Hounsfield Units] +/- 22), hyperechoic (91 HU +/- 22), and calcified plaques (391 HU +/- 156, p < 0.02). CONCLUSIONS: This study demonstrates that, in the case of diagnostic image quality, contrast-enhanced MDCT permits an accurate identification of coronary plaques and that computed tomography density values measured within plaques reflect echogenity and plaque composition.

Aged↗

Advances in cardiac CT imaging: 64-slice scanner.

BACKGROUND: Clinical progress by the development of multi-slice CT (MSCT) technology beyond 16 slices can more likely be expected from further improved spatial and temporal resolution rather than from a mere increase in the volume coverage speed. We present an evaluation of a recently introduced 64-slice CT (64SCT) system, which makes use of a periodic motion of the focal spot in the longitudinal direction (z-flying focal spot) to double the number of simultaneously acquired slices. MATERIALS AND METHODS: A recently introduced 64SCT system (SOMATOM Sensation 64, Siemens Medical Solutions, Forchheim, Germany) is being described and tested in first clinical practice, applying the following parameters: z-flying focal spot technology, 64 x 0.6 mm slices; spatial resolution, 0.4 x 0.4 x 0.4 mm; gantry rotation time, 330 ms; temporal resolution, 83-165 ms. Various phantom studies and first clinically implemented protocols are being described, to evaluate the full spectrum of possible applications for this scanner type, with a focus on cardiac imaging. RESULTS: ECG-gated cardiac scanning with this 64-slice CT system benefits clearly from both the improved temporal resolution and improved spatial resolution. These benefits enable a more reliable assessment of mixed plaques, due to reduced partial-voluming and beam-hardening artefacts caused by calcifications, and holds great promise for the reliable assessment of in-stent stenoses, as stent lumen visibility is clearly improved as compared to earlier MSCT systems. With the increased volume coverage and acquisition speed of the 64SCT system, a comprehensive emergency protocol of the thorax becomes feasible within an acceptable breath-hold time, performing an ECG-gated CT angiography of the complete thoracic vasculature. This protocol enables a detailed assessment of the thoracic aorta, the pulmonary arteries and the coronary arteries in one single examination. CONCLUSIONS: 64SCT Cardiac imaging provides an increased spatial resolution with an isotropic voxel size of 0.4 mm and an improved temporal resolution of 83-165 ms. These benefits hold great promise especially for fast-moving organs requiring detailed imaging, such as the heart and coronary arteries.

Calcinosis↗