Evaluation of thermal- and photo-crosslinked biodegradable poly(propylene fumarate)-based networks.

Biodegradable networks of poly(propylene fumarate) (PPF) and the crosslinking reagent poly(propylene fumarate)-diacrylate (PPF-DA) were prepared with thermal- and photo-initiator systems. Thermal-crosslinking was performed with benzoyl peroxide (BP), which is accelerated by N,N-dimethyl-p-toluidine (DMT) and enables injection and in situ polymerization. Photo-crosslinking was accomplished with bis(2,4,6-trimethylbenzoyl) phenylphosphine oxide (BAPO), which is activated by long-wavelength UV light and facilitates material processing with rapid manufacturing techniques, such as stereolithography. Networks were evaluated to assess the effects of the initiators and the PPF/PPF-DA double bond ratio on the mechanical properties. Regardless of the initiator system, the compressive properties of the PPF/PPF-DA networks increased as the double bond ratio decreased from 2 to 0.5. BAPO/UV-initiated networks were significantly stronger than those formed with BP/DMT. The compressive modulus of the photo- and thermal-crosslinked PPF/PPF-DA networks ranged from 310 +/- 25 to 1270 +/- 286 MPa and 75 +/- 8 to 332 +/- 89 MPa, respectively. The corresponding fracture strengths varied from 58 +/- 7 to 129 +/- 17 MPa and 31 +/- 13 to 105 +/- 12 MPa. The mechanical properties were not affected by the initiator concentration. Characterization of the network structures indicated that BAPO was a more efficient initiator for the crosslinking of PPF/PPF-DA, achieving a higher double bond conversion and crosslinking density than its BP counterpart. Estimated average molecular weights between crosslinks (Mc) confirmed the effects of the initiators and PPF/PPF-DA double bond ratio on the mechanical properties. This work demonstrates the capability to control the properties of PPF/PPF-DA networks as well as their versatility to be used as an injectable material or a prefabricated implant.

Biocompatible Materials↗

In vitro degradation of polymeric networks of poly(propylene fumarate) and the crosslinking macromer poly(propylene fumarate)-diacrylate.

Polymeric networks of poly(propylene fumarate) (PPF) crosslinked with poly(propylene fumarate)-diacrylate (PPF-DA) are currently being investigated as an injectable, biodegradable bone cement. This study examined the effect of crosslinking density, medium pH, and the incorporation of a beta-tricalcium phosphate (beta-TCP) filler on the in vitro degradation of PPF/PPF-DA. Cylindrical specimens were submerged in buffered saline at 37 degrees C and the change in weight, geometry, and compressive mechanical properties were monitored over a 52-week period. All formulations showed an initial increase in modulus and yield strength over the first 12 weeks, achieving maxima of 1307+/-101 and 51+/-3MPa, respectively, for the beta-TCP composite. PPF/PPF-DA networks with the lower crosslinking density demonstrated the greatest degradation with a 17% mass loss. Samples in the lower buffer pH 5.0 compared to physiological pH 7.4 did not show any differences in mass loss, but exhibited a faster decrease in the compressive strength over time. The beta-TCP composites maintained their mechanical properties at the level following their initial increase. These results show that the degradation of PPF/PPF-DA networks can be controlled by the crosslinking density, accelerated at a lower pH, and prolonged with the incorporation of the beta-TCP filler.

Acrylates↗

Fabrication of poly(propylene fumarate)-based orthopaedic implants by photo-crosslinking through transparent silicone molds.

This work presents a new molding process for photo-crosslinked, degradable polymeric networks of poly(propylene fumarate) (PPF) and the crosslinking agent poly(propylene fumarate)-diacrylate (PPF-DA). Transparent room temperature vulcanizing silicone molds were fabricated for parts ranging from simple test coupons to orthopaedic implants. The PPF/PPF-DA resin blend was injected into the cavity and photo-crosslinked as light was transmitted through the mold wall. The volumetric shrinkage, mechanical properties, and the effects of gamma sterilization were reported for molded PPF/PPF-DA networks prepared with varying compositions of the two polymer components. The shrinkage decreased while the mechanical properties displayed a general increasing trend when more of the crosslinking agent was incorporated into the network. Gamma irradiation resulted in an improvement of the mechanical properties. In addition, PPF/PPF-DA replicates of a 70:30 poly(L/DL-lactide) biodegradable fixation plate and a bone allograft interbody fusion spacer were produced to evaluate the performance of PPF/PPF-DA as an orthopaedic implant and allow for a comparison to be made with materials that have been established for clinical use.

Absorbable Implants↗

Constrained acetabular cups: a cadaveric biomechanical evaluation.

Reports indicate that constrained acetabular cups may reduce range of motion and catastrophically fail, although the biomechanics of dislocation have not been reported. We measured the available motion in 6 constrained cups (from 2 manufacturers) when anatomically placed in cadaver pelves. We measured the torque and rotation necessary to dislocate the hip. Range of motion was measured using a custom jig and revealed a functional range of motion with all cup positions. Extension was limited to 0 degrees with anteversion of 11 degrees to 29 degrees. Thus, anteversion of <10 degrees is recommended. Torque and rotation to produce dislocation was 7 ft-pounds and 11 ft-pounds and 82 degrees and 72 degrees, for each manufacturer. Torques were reduced with subsequent dislocations. We recommend consideration of polyethylene replacement if dislocation occurs. Dislocation occurred at the ball-polyethylene interface without catastrophic failure.

Acetabulum↗

Effect of physiological temperature on the mechanical properties and network structure of biodegradable poly(propylene fumarate)-based networks.

Poly(propylene fumarate) (PPF)-based networks have exhibited increases in mechanical properties during their initial stages of degradation. This study was designed to investigate whether physiological temperatures are the source of this reinforcing behavior by influencing the formation of additional crosslinks within the network. Utilizing a model PPF network formed with the crosslinking agent poly(propylene fumarate)-diacrylate (PPF-DA), cylindrical specimens were stored in an inert environment and conditioned at -20 and 37 degrees C while their mechanical properties and network structure were monitored over a six week period. The PPF/PPF-DA specimens exposed to physiological temperatures showed an increase in compressive modulus from 1674 +/- 88 to 2059 +/- 75 MPa. The double bond conversion improved as well, from 64 +/- 1 to 70 +/- 1%, indicating that crosslinks were being formed in the network. The additional reactivity occurred exclusively with unreacted fumarate bonds. PPF/PPF-DA networks stored at -20 degrees C showed no changes in mechanical properties; however, they increased when subsequently conditioned at 37 degrees C. The results were used to explain that PPF-based networks undergo a biphasic degradation behavior due to the competing hydrolytic degradation and thermal induced crosslinking. In addition, heat treating the networks at higher temperatures can be utilized as a means to further reinforce PPF-based materials.

Biocompatible Materials↗

Tendon transfer fixation in the foot and ankle: a biomechanical study evaluating two sizes of pilot holes for bioabsorbable screws.

The purpose of this study was to compare the initial fixation strengths of bioabsorbable screws for tendon transfers in the foot and ankle when the pilot hole size varied. A 7 x 20 mm screw was used with 5.5 mm and 6.5 mm drill holes, and a 5 x 20 mm screw was used with 3.9 mm and 4.5 mm drill holes. Biomechanical testing was performed on each tendon transfer in cadaver specimens. A paired t-test showed no significant difference in pullout strength when pilot hole size varied between 79 to 93% of the screw size for the 7 mm screw and 78 to 90% of the screw size for the 5 mm screw. Previous studies have found a critical value of tendon tension equaling 50 N with passive dorsiflexion of the foot. With an average value of approximately 170 N, the 7 mm screw provided three times the requisite strength. The 5 mm screw provided 1.5 times the requisite strength, but the transfer was technically more difficult.

Absorbable Implants↗

Undertreatment of osteoporosis in men with hip fracture.

BACKGROUND: Women are not aggressively treated for osteoporosis after hip fracture; the treatment status of men with hip fracture has not been extensively studied. OBJECTIVE: To evaluate the outcome and treatment status of men with hip fracture. METHODS: Data from medical records were obtained for 363 patients (110 men and 253 women) aged 50 years and older with atraumatic (low-energy) hip fracture who were admitted to St Luke's Episcopal Hospital between January 1, 1996, and December 31, 2000. Surveys were mailed to surviving patients. Main outcome variables were osteoporosis treatments (antiresorptive or calcium and vitamin D) at hospital discharge, current osteoporosis treatments at 1- to 5-year follow-up, bone mineral density testing, mortality, current disability, and living arrangements (home or institution). RESULTS: The mean age for men was 80 years vs 81 years for women. Most fractures (89% for men and 93% for women) resulted from falls from a standing height. At hospital discharge, 4.5% of men (n = 5) had treatment of any kind for osteoporosis, compared with 27% of women (n = 69) (P<.001). The 12-month mortality was 32% in men, compared with 17% in women (P =.003). Surveys were usable from 168 (87%) of 194 survivors. At 1- to 5-year follow-up, 27% (12/44) of men were taking treatment of any kind for osteoporosis, compared with 71% (88/124) of women (P<.001). Of those treated, 67% (8/12) of men and 32% (28/88) of women were taking calcium and vitamin D only. At 1- to 5-year follow-up, 11% of men had a bone mineral density measurement, compared with 27% of women. After hospital discharge, the number of men and women who required wheelchairs, walkers, and canes and who lived in institutions increased significantly. CONCLUSIONS: The burden of hip fracture is illustrated by the high incidence of postfracture disability and the high mortality rate in both men and women. Nevertheless, few men receive antiresorptive treatment.

Aged↗

Fluid flow increases mineralized matrix deposition in 3D perfusion culture of marrow stromal osteoblasts in a dose-dependent manner.

Bone is a complex highly structured mechanically active 3D tissue composed of cellular and matrix elements. The true biological environment of a bone cell is thus derived from a dynamic interaction between responsively active cells experiencing mechanical forces and a continuously changing 3D matrix architecture. To investigate this phenomenon in vitro, marrow stromal osteoblasts were cultured on 3D scaffolds under flow perfusion with different rates of flow for an extended period to permit osteoblast differentiation and significant matrix production and mineralization. With all flow conditions, mineralized matrix production was dramatically increased over statically cultured constructs with the total calcium content of the cultured scaffolds increasing with increasing flow rate. Flow perfusion induced de novo tissue modeling with the formation of pore-like structures in the scaffolds and enhanced the distribution of cells and matrix throughout the scaffolds. These results represent reporting of the long-term effects of fluid flow on primary differentiating osteoblasts and indicate that fluid flow has far-reaching effects on osteoblast differentiation and phenotypic expression in vitro. Flow perfusion culture permits the generation and study of a 3D, actively modeled, mineralized matrix and can therefore be a valuable tool for both bone biology and tissue engineering.

Alkaline Phosphatase↗

Biomechanical testing of cadaveric specimens: importance of bone mineral density assessment.

The bone density of cadaveric specimens is highly variable and has a significant effect on the results of biomechanical testing but it is not often assessed before testing is performed in the lab. Bone mineral density (BMD) tests such as dual X-ray absorptiometry (DXA) are widely available, easy to perform and correlate highly and significantly with bone strength in many modes of failure. We present the results of two different studies performed on cadaveric foot and ankle specimens. In these studies the results vary significantly according to BMD, and this effect is not always eliminated with the use of matched pairs of cadaveric specimens.

Ankle Joint↗

In vitro cytotoxicity of injectable and biodegradable poly(propylene fumarate)-based networks: unreacted macromers, cross-linked networks, and degradation products.

This study evaluates the in vitro biocompatibility of an injectable and biodegradable polymeric network based on poly(propylene fumarate) (PPF) and the cross-linking agent PPF-diacrylate (PPF-DA). Using a methyl tetrazolium (MTT) assay, the effect of the concentrations of PPF and PPF-DA on the cytotoxicity of its unreacted macromers, cross-linked networks, and degradation products was examined. The influence of network structure properties on cell viability and attachment to the cross-linked material was also investigated. The unreacted macromers exhibited a time- and dose-dependent cytotoxic response that increased with more PPF-DA in the mixture. Conversely, the cross-linked networks formed with more PPF-DA did not demonstrate an adverse response because increases in conversion and cross-linking density prevented the extraction of toxic products. Fibroblast attachment was observed on the PPF/PPF-DA networks with the highest double bond conversions. The degradation products, obtained from the complete breakdown of the networks in basic conditions, displayed a dose-dependent cytotoxic response. These results show that there are concerns regarding the biocompatibility of injectable, biodegradable PPF/PPF-DA networks but also sheds light onto potential mechanisms to reduce the cytotoxic effects.

Absorbable Implants↗